| 1 | Demolition of cement concrete (un reinforced) in ground floors and pavings n. exc 15 cm thickness (below or above ground level)complete all as specifeid and directed. |
| 2 | M & L hard core of for broken stone boulder of gage n.exc 63mm deposited, spread and levelled in layers n.exc 15 cm thick watered and rammed to a true surfaces complete all as specifeid and directed. |
| 3 | M&L Cement concrete 1:4:8 type D- 2,(using 40mm graded stone aggregate) for mass concrete complete all as specified and as directed. |
| 4 | M & L for100mm Cement concrete 1:4:8 type D- 2,(using 40mm graded stone aggregate) complete all as specified and as directed. |
| 5 | Providing and laying 60mm thick laquer finish (ISI Marked) factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed. |
| 6 | Providing and laying 80mm thick laquer finish (ISI Marked) factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed. |
| 7 | M&L Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed. |
| 8 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 9 | M&L for screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:4 for laying floor finishescomplete all as specified and directed |
| 10 | M&L for chequered cement concrete tiles 250mm x 250mmx 20 to 22mm thick (ISI marked) of approved colour, set jointed and pointed in cement slurry in floors with grey cement and pigments complete all as specified and as directed. |
| 11 | M&L for screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 for laying floor finishescomplete all as specified and directed |
| 12 | M&L for heavy duty pavementceramic tile size nexc 0.36 sqm and 10 mm thick set and jointed in neat cement slurry and pointed in coloured cement to match laid over complete all as specified and directed. |
| 13 | M&L 75 mm thick PCC 1:3:6 Type C2 (using 40 mm graded stone aggregate)as in plinth protection , PCC will be laid with 12 mm gap & the gap will be filled up with bituminous joint filler type A complete all as specified and as directed. |
| 14 | M&L 100 mm thick PCC 1:2:4 Type B2 (using 40 mm graded stone aggregate)as in Floor , PCC will be laid with 12 mm gap & the gap will be filled up with bituminous joint filler type A complete all as specified and as directed. |
| 15 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 16 | M&L Roof trusses (framed), trussed, purlins, crane gantries, rails,column for trusses, rafter and fastenings and heavy bracket framing (Beam, tee, angle, tubular, channel or flat sections) including distance pieces, cleats etc complete all as specified and as directed. |
| 17 | Dismantling of Asbestos cement (corrugated, semi corrugated etc)/CGI sheets in roof covering complete all as specified and as directed. |
| 18 | Material and Labour for pre-painted, galvalume aluminium zinc coating GI based profiled steel sheet, 0.50 mm thick of any colour, having tensile strength of 550 Mpa AZ-150, as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 19 | S&F 0.50mm thick pre-painted galvalume zinc coated GI based plain sheet of any colour having tensile strength of 550 Mpa, AZ-150 fixed as in roof covering/ cladding to wall, ridges, valley gutteretc with self tapping screws complete all as specified and directed. |
| 20 | M&L preparation or new steel and iron surfaces of any description and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 21 | M&L preparation or new concrete surfaces of any description and applying two coats of plastic emulsion paint over a coat of primer complete all as specified and directed. |
| 22 | M&L preparation of old concrete surfaces of any description and applying one coats of plastic emulsion paint complete all as specified and directed. |
| 23 | Demolition of reinforced concrete of any description and in anypositionnot otherwise specifically provided for etc complete all as specified anddirected. |
| 24 | M&L precast cement concrete 1:2:4 type B1 (using 20mm graded stone agregate) including necessary form work as in manholes cover slab etc, set in cement mortar 1:4 complete all as specified and as directed. (Note :- Re-inforcement shall be measured and paid for separately under respective items of Sch \"A\" here in after) |
| 25 | M&L for Mild TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping forcolumns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clipscomplete all as specified anddirected. |
| 26 | M&L PCC 1:2:4 type B-2 (using 40mm graded stone aggregate) as in coping, mass concrete etc complete all as specified and as directed. |
| 27 | M & L for preparing bituminous surfaces of road and marking 1.25 mm thick centre lines, stop lines, dashes, arrows etc. and the like n. exc 10cm wide on roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufacturers instruction complete all as specified and directed. |