| 1 | Demolition of reinforced cement concreteof any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed. |
| 2 | M&L RCC, Cement concrete type B0 1:2:4 (12.5mm graded stone aggregate) as in floor/roofSlab and roof projectionSlabs supported on walls, beams and columns in floors, roofs, landings,balconies, canopies, deck slabs and in shelves and the like similar work complete all as specified and directed. |
| 3 | M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, column, beam landings and similar work n exc 200mm thick complete all as specified and directed. |
| 4 | M&L MS TMT bars 10 mm dia and above , cut to length ,bent to shape required , including cranking , bending , spirally for hooping forcolumns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in reinforcement complete all as specified and directed. |
| 5 | M&L for Dismantling/ taking down old existing unserviceable cement plaster, loose/ unsound weaken cement concrete of any description and in any position from existing external / internal surface of RCC roof/ slab/ beams/ columns/ RCC facias for an average depth of 25mm (Approx height 7.5m from natural ground level) with power driven pneumatic flat/pointed chisel and removing the honeycombed area including all the corners and making a neat profile of the cavities, roughen the smooth surface , scrapping out/removing corrosion all loose/scale/rust etc form the visible reinforcement by applying rust remover such as Rust Off 100 of make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s BOSTIk India pvt limited, M/s STP Limited, M/s ThermaxLimited( as approved by GE) and cleaning the steel reinforcement properly all as per manufacturer instructions and all as specified and directed and comprising of below mentioned process :- |
| 6 | (a) Providing cement based admixed with Sikacim, integralwaterproofing liquid M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, , M/s BOSTIk India pvt limited, M/s STP Limited, M/s Thermex Ltd (as approved by GE) @ 0.2% by weight of cement or as per manufacturer’sinstructions over a coat of acrylic emulsion bonding agent such as per as Sika Latex in 1:1:3 ratio of Make M/s Sika India Pvt Ltd, or equivalent in M/S Fosroc chemicals, M/s BOSTIkIndia pvt limited, M/s STP Limited, M/s Thermex Ltd (as approved by GE) having specific gravity of 1.02 or as per manufacturer’s instructions with necessary surface preparation such as creating mechanical key like roughening the surface by scrabbing, grit blasting and cleaning the existing surface using high pressure water jet machine having pressure upto 500 barpressure to remove the dirt, dust, loose particles , wax, efforencene and other contaminations from the surface of RCC columns/ beams/ slabs/ facia/ any brick/ stone surfaces etc all as per manufacturer instructions and all as specified and directed by Engineer-in-Charge. |
| 7 | (b) Providing and applying FRIAZINC R, corrosion inhabiliting Active Zinc rich primer of make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, , M/s BOSTIk India pvt limited, M/s STP Limited, M/s Thermex Ltd (as approved by GE) along the exposed reinforcement surface property and allowed to dry. |
| 8 | (c) Providing and applying Hibond, Epoxy based Thixotropic bonding adhesive of Make of M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s BOSTIk India pvt limited, M/s STP Limited, M/s Thermex Ltd ( as approved by GE) over the prepared concrete surface to get a good bonding between existing concrete surface and providing Sika Rep Microcrete 4 Fiber reinforced cementitious repair micro concrete of make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s BOSTIk India pvt limited, M/s STP Limited, M/s Thermex Ltd ( as approved by GE) over Epoxy based bonding agent applied area before 6 Hrs etc including providing necessary proportions , bracing and runners to relieve the member from the load coming on it including scaffolding leak proof shuttering with working platform as required and as per design and pattern complete including preparing the surface to match with the existing surface all as specified and directed. |
| 9 | (d) Note : The work under (Item No. 5 to 8 of BOQ) shall be carried out through authorized and qualified applicators of the any following manufacturer only. M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s STP Limited,M/s BOSTIk India pvt limited,M/s ThermaxLimited |
| 10 | (i)A performance guarantee certificate for two years shall be submitted by the contractor to the GE on completion of work as specified. |
| 11 | (ii) The unit rate quoted for item No. 5 to 8 of BOQ is deemed to be included for Removing of accumulated earth of any width and depth upto 15 cm cleaning/cutting the grass with hand operated petrol/kerosene driven grass cutting machine and removing the grass waste around 3 m from plinth protectionto outside MD land Note: Periodicityof cutting of grass shall be before commencement of work and after completion of repairs. |
| 12 | M & L preparation of old surfaces by complete removal of existing treatmentof wall by using pressure washer, ofexterior wall decorating and water proofing treatment to wall surface by wire brushing in order to remove dust, dirt, loose particles, laitance. Thereafter wash the surface with clean water & allow to dry.Making groove as requirment according to crack, clean with water, Fill visible cracks/ joints by smart care crack sealer caulking compound & allow to dry for 24 hours. Apply a primer coat of (apex ultima protek base coat or equivalent) and allow to dry for 6 hours. Thereafter apply 02 coats of Weather coat (apex ultima protek top coat or equivalent) & shade by brush at the interval of 08 hours between the coat and allow to dry to match the existing shade including necessary scaffolding for any height, covering etc ( as approved by GE) and all as per manufacturer instructions and all as specified and directed.Note: (i)The unit quoted rate shall be inclusive of material,any height of bldg of any size and all labours, tools and plants including scaffolding required for working upto approx 25 mtr height from natural ground level and nothing extra shall be admissible on this account. (ii) Adoption of necessary safety arrangement like safety belts, ropes, helmets, netting etc. which are required for safety of working labour at height exceeding 3 to 35 mtr height shall be mandatary and deemed to be included in the unit rate quoted. |
| 13 | M&L Repair of leakage/seepage from the wall/ door bend /door tee/\"Y\" junction/ \"T\" Junction of soil pipe / waste pipe/ vent pipe of kitchen/ bathroom/WC upto G+3 ht or at the ground floor Qtr including change of any damage soil waste pipes or fittings of any shape, specification and size, making good to the damaged portion of wall with brick work in cement mortar 1:6 or cement concrete 1:2:4 and plastering to wall in CM 1:4 and finished the surfaces matching to existing wall complete to avoid the leakage/ seepage at the site of work as directed and as specified. |
| 14 | Supply and fixing 25 mm bore galvanized steel water tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down old steel tubing complete all as specified and directed. |
| 15 | Supply and fixing 40 mm bore galvanized steel water tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down old steel tubing complete all as specified and directed. |
| 16 | Cutting chases pinning in making good to facing where required for concealed water tubing any size and making good with CM 1:3 cutting not exc 10cm girth in brick/stonewalls complete all as specified and directed. |
| 17 | S & F Bib taps cast copper alloy chromium plated fancy type screwed down screwed foriron pipe or for brass ferrule and fixed for 15 mm bore complete all as specified and as directed. |
| 18 | S & F 15 mm dia stop/angle valves of cast copper alloy fancy type chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and as directed. |
| 19 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 meter long flexible tube and ABS wall hook including taking down existing one complete all as specified and as directed. |
| 20 | S&F in repais Toilet paper holder of stainless steel fixed to walls with CP screws Complete all as specified and as directed. |
| 21 | S&F in repairs, 10 litre capacity PVC flushing cistern, syphonic action type, low level, white, with inlet, ball valve,pvc flush pipe, float and handle incl brackets and waste pipe complete., making proper fixing and hanging arrangements all as specified and as directed. |
| 22 | S & F in repairs vitreous china wash down water closet (Pedestral pattern) EWC white incl plastic water closet seat cover and mild steel chromium plated or aluminium hinging device and connecting to \"P\" or \"S\" trap incl connecting flush pipe with flushing rim complete all as specified and as directed. |
| 23 | Supply and fixing in repairs plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device all as specified and directed. |
| 24 | S&F Wash hand basin table counter type 560x400x200mm vitreous china (white) oval shape with cantilever CI/Angle iron bracketsembedded in concrete block, including long shank pillar tap, brass chromium plated waste coupling 32mm bore, waste pipe bottle trap, complete all as specified and as directed. |
| 25 | S&F in repairs 40mm bore unplasticised PVC pipe of pressure rating 10 kg/Sqcm fixed complete to walls, ceiling or laid in floors complete all as specified and directed. |
| 26 | S&F Brass chromium platedtowel ringfixed with CP screws complete all as specified and directed. |
| 27 | S&F Tubular Towel Rail 20mm dia, Brass Chromium Plated, D-type, 60 Cm long between Flanges with Bracket (one Pair) , complete all as specified and as directed. |
| 28 | S&F in repairs PVC connections 15mm size with PTMT nuts of length 600 mm all as specified and as directed |
| 29 | S&F in repairs Overhead Shower rose 125mm size (Brass Chrome Plated)complete all as specified and as directed. |
| 30 | S&F CP concealed stop cock, Regular body with adjustable wall flange screwed down screwedfor iron pipe15mm bore.including taking down existing one complete all as specified and as directed. |
| 31 | S&F Gun-metal Globe or gate valves 20 mm nominal bore dia with iron wheel head screwed both ends for iron pipes and fixed complete as specified and as directed. |
| 32 | S&F in repair PVC gully/floor trap 125/110 mm dia, with stainlesss steel grating including jointing to waste pipe fixed in solvent cementall asspecified and directed. |
| 33 | Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including taking up or down oldtubing complete all as specified and directed. |
| 34 | Supplying and fixing of 20mm outer dia Female Brass Threaded Adaptor (FTA/ FBTA CPVC complete all as specified. |
| 35 | Supplying and fixing of 20mm outer dia CPVC brass elbow and all as specified. |
| 36 | Supplying and laying of 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including taking up or down old tubing complete all as specified and directed. |
| 37 | Supplying and fixing of 25mm outer dia Female Brass Threaded Adaptor (FTA/ FBTA CPVC complete all as specified. |
| 38 | Supplying and fixing of 25mm outer dia CPVC brass elbow and all as specified. |
| 39 | S&F in repairs CP 2 way bib cock with wall flange fancy type screwed down screwedfor iron pipe in repairs 15mm bore complete all as specified and as directed. |
| 40 | S & F in repair PVC waste pipe 32 to40mm for WHB/Sink up to floor trap and fixed complete all as specified and directed. |
| 41 | M&L forceramic coloured tiles of size 350mmx250mm/ 300mm X 450mmx7 to 8 mm thick, on vertical surfaces, set and jointed in neat cement slurry and pointed in coloured / white cement to match the tiles inc rendering 10mm thick in CM 1:4 on fair faces of brick work or concrete surfaces as in backing coat to receive wall tiles etc and dismantling of floor, hearth or wall tiling incl cement mortar bedding and removing debris and depositing where directed complete all as specified and as directed. |
| 42 | M&L for joint free non skid coloured ceramic tiles 7 to 8 mm thick area of each tile not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointedin white or coloured cement to match incl 15 mm thick screed bed in cement mortar 1:4 for layingfloor finishesanddismantling of floor, hearth or wall tiling incl cement mortar bedding and removing debris and depositing where directed complete all as specified and as directed. |
| 43 | Removing plant/Uprooting of vegetation growth including roots on wall/roof/parapet near pipes etc and applying acid treatment afterremoving roots for preventing regrowth and making good disturbed surfaces/area in superficial area exc 150sq.cm but n.exc 400 sq.cm and averaging depth not exceeding 10 cm by using PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) or 10mm thick plastering in cement mortar 1:3 as required and finishing the surfaces to match with the existing surface complete all as specified and directed. |
| 44 | Taking downcementplaster on stone wall / brick wall or ceiling etcincluding racking out of joints hacking for keys scrubbing down with water complete all as specified and directed. |
| 45 | M&L for cement plaster rendering 15mm thick on fair faces of brick/concrete surfaces with two coats i.e. (10mm thick backing coat in CM 1:6 and 5mm thick finishing coat in CM 1:4) and mixed with WPC as per manufacturer instructions, surface finished even and smooth without using extra cement (WPC to be measured and paid separately) complete all as specified and directed. |
| 46 | Supply only Integral liquid waterproofing compound of approved make (ISI marked) all as specified and directed. |
| 47 | Material & Labour for applying two or more coats of exterior emulsion weather proof paintincluding priming coat of exterior primer applied over new surfaces complete all as specified and as directed. |
| 48 | M&L 10 mm thick cement plaster in CM 1:4 on fair faces of brick/ concrete block stone/ concrete including WPC as per manufacturer instructions surfacefinished even and smooth without using extra cement complete all as specified and directed. |
| 49 | M & L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed. |
| 50 | M&L for cement plaster rendering 5mm thick in CM 1:3 on fair faces of brickwork or concrete surface as on ceilling finished even and smooth with thin layer of sagol complete all as specified and directed. |
| 51 | M & L for preparation of new plastered orunplastered surfaces of ceilingsincludingcornices, etcand applying two coatof oil bound distemper over a coat of primer complete allas specified and directed. |
| 52 | Taking down chowkhat or frame (wooden/steel) not exceeding1.5 Sqm each with shutter (with out taking off shutters from the frame) complete all as specified and as directed. |
| 53 | Supply & Fixing solid PVC door frame of size50 mm x 47 mm made out of 5 mm plain colourPVC sheetreinforced with MS square tube and edges will be painted to match with printed sheet fixed in opening as per specification & drawings complete all as specified and as directed. |
| 54 | M&L Factory Made Solid PVC Moulded Door Shutter, with particle board core 28 to 30 mm thick (stiles),with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm Plain colour PVC Sheet on back face including necessary fittings etc complete as specified and directed. |
| 55 | S&F MS butt hinges medium weight cold rolled 75mm complete all as specified and directed. |
| 56 | S& F Aluminium anoldised handle150 mm long complete all as specified and directed. |
| 57 | S&F Aluminium anoldised barrel tower bolt 125 mm long complete all as specified and directed. |
| 58 | S&F in repair looking mirror of size 600mm x 450mm on commerical ply wood 6mm thick with PVC/ wooden moulding beading fixed to wooden plugs with chromium plated brass, screws and cup, washers, aluminium frame and fixed complete all as specified and directed. |
| 59 | M&L Granite 18 to 20mm thick (table rubbed and polished) in steps,Jambs, Pillars, Windows, cills, platforms and like in CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigments to match with marble shade of Granite over screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:4) all as specified and as directed. Note :(i)The Unit rate quoted is included for demolition of old Stone Slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar.(ii)Cost of rounding of stone deem to be included in unit quoted rate. |
| 60 | Treatment of the sunken floor slab comprises of the following specification and all as specified and directed.Make :-Dr Fixit/ M/s Sika india Pvt Ltd/ STP Ltd/ M/s Fosroc Chemicals |
| 61 | (a) Demolition of cement concrete filling of any description in sunken portion in toilet and removing debris outside MD land. |
| 62 | (b) Cleaning the sunken/ lowered portion of RCC slab surfaces (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding conc to achieve proper slope including cutting holes in bricks or RCC wall for spout (WPC shall be measured and paid separately) |
| 63 | (c) Rendering of uneven surfaces with 10mm thick CM 1:4 mixed with integral water proofing compound as per manufacturer instructions. Fill it with water and check dampness and seepage. Where dampness/ seepage is noticed, nozzles shall be fixed and grouting carried out. (WPC shall be measured and paid separately). |
| 64 | (d)All junctions points of side wall spout where CI/ GI pipes are passing through shall be sealed with epoxy putty. |
| 65 | (e)After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. |
| 66 | (f) Material and labourfor applying two coats of polymer modified cementious water proof coating as per manufactures instruction to bottom and vertical sides up to finished floor level+300mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed (This item shall be measured and paid separately) |
| 67 | (g)Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound as per manufacturers specification including rounding of corners and junctions sloping towards spout. (WPC shall be measured & paid separately). |
| 68 | (h)Material and labourfor PCC 1:5:10 type E2, n exc 150mm thick complete all as specified |
| 69 | (j) Material and labourfor PCC 1:2:4 type B0 using 12.5mm graded stone aggregate, 50mm tnick complete all as specified and directed. |
| 70 | Note for item No 60 to 69 :- Test the water proof area (ponding test) by filling water for at least 72 hours and tested for leakage, seepage to the entire satisfaction of GE. Test shall be done in presence of reps of Engineer-in-Charge. The treatment shall be carried out by authorised applicator of chemicals. Cost of testing is included in the unit quoted rate above and nothing extra shall be admissible on this account. |
| 71 | Material and labourfor Water proofing treatment to the sunken portion applying two coat of two component (1 part Polymer and second part cementations powder) cementations, polymer modified elastomeric, water proofing coating composed of cement, properly selected and graded aggregates, additive and acrylic emulsion polymer as a binder apply first coat of (mix and application as per manufacturer’s instructions) all over floor surface. Prepared surface and apply to vertical surface up to 15cm from tiling level, allow to dry 4 to 6 hours. Prepare for apply 2nd coat perpendicular to first coat and allow to dry 4 to 6 hours. All joints to Trap/WC/Soil pipe shall be properly sealed with sealing compound/polymer modified mortar using Dr Fixit Pidicrete UBP or equivalent in M/s Pidilite orM/s Sika Chemical, Slope of slab shall be towards and including GI pipe 50mm dia of suitable length Spout pipe. Providing 15mm protective screed with cement mortar in 1.3 with WPC (Make : Dr Fixit LW + or equivalent in M/s Pidilite orM/s Sika Chemical) within 2 to 3 days of second coat complete all as specified as per manufacturer instructions. Make : Dr Fixit Pidfin 2K or equivalent in M/s Pidilite orM/s Sika Chemical complete all specified and directed by Engineer-in-Charge. |
| 72 | Note : The treatment shall be carried out by authorised applicator of chemicals. Cost of testing is included in the unit quoted rate above and nothing extra shall be admissible on this account. |
| 73 | Supply and fix 110mm dia PVC (SWR) pipe single socket in any length with rubber ring joint fixed to wall or laid in trenches including taking down old u/s drain pipe complete all as specified and as directed. |
| 74 | S&F PVC bends 110mm borecomplete all as specified and as directed |
| 75 | Supply and fix 75mm dia PVC (SWR) pipe single socket in any length with rubber ring joint fixed to wall or laid in trenches including taking down old u/s drain pipe complete all as specified and as directed. |
| 76 | S&F PVC bends 75mm borecomplete all as specified and as directed |
| 77 | M&L for preparation of old plastered surfaces, by complete removal of existing treatmentof wall using pressure washer, removal all dirt and dust, applying water proofing putty and applying two coat of exterior emulsion weather proof paintover a coat of primer complete all as specified and as directed. |
| 78 | Material and labourfor Preparation of old decoratedplastered or unplastered surfaceof wall, brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , trading, oil, greasy spots and applying one coat of cement based paint complete all as specified and as directed. |
| 79 | Material and labourfor Preparation of old plastered or unplastered surface, Complete removal of existing treatment of wall brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , trading, oil, greasy spots and applyingone coat of oil bound distemper complete all as specified and directed. |
| 80 | Complete removal of existing treatment ofold walls and washing, rubbing down, applying two coat smartcare damp block 2K or equivalent @ 15sqft/kg to arrest the dampness of wall/ceiling and finish the surface with water proofing putty of 1mm thick even smooth and two coats of oil bond distemper over a coat of primer complete all as specified and directed.Note: (i)The unit quoted rate shall be inclusive of material,any helght of bldg of any size and all labours, tools and plants including scaffolding required for working upto approx 25 mtr height from natural ground level and nothing extra shall be admissible on this account. (ii) Adoption of necessary safety arrangement like safety belts, ropes, helmets, netting etc. which are required for safety of working labour at height exceeding 3 to 25 mtr height shall be mandatary and deemed to be included in the unit rate quoted. |
| 81 | Note :- An amount of Rs 12,750.00 on account of credit schedule for schedule \"A\" part II shall be deducted from the total amount of BOQ to arrive at the contract sum. |