|
| 1 | M&L in repair for starter panel suitable for AHU 28000 CFM complete all as spcieied and as directed by Engr-in-charge. Note : Cost of required nos of contactors, MCB, connectors , relays and any other minor parts are deemed to be included in the quoted rate. |
| 2 | M&L in repair for starter panel suitable for AHU 14500 CFM complete all as spcieied and as directed by Engr-in-charge. Note : Cost of required nos of contactors, MCB, connectors , relays and any other minor parts are deemed to be included in the quoted rate. |
| 3 | M&L in repair PFC board suitable for 10 KVA DX RT UPS complete all as specified and as directed by Engr-in-charge . Make - ETAON or as approved by GE. |
| 4 | M&L in repair Invertorboard suitable for 10 KVA DX RT UPS complete all as specified and as directed by Engr-in-charge . Make - ETAON or as approved by GE. |
| 5 | M&L in repair Control board suitable for 10 KVA DX RT UPS complete all as specified and as directed by Engr-in-charge . Make - ETAON or as approved by GE. |
| 6 | M&L in repair communication board suitable for 10 KVA DX RT UPS complete all as specified and as directed by Engr-in-charge . Make - ETAON or as approved by GE. |
| 7 | M&L in repair LCD board suitable for 10 KVA DX RT UPS complete all as specified and as directed by Engr-in-charge . Make - ETAON or as approved by GE. |
| 8 | M&L in repair ETO PCB suitable for 10 KVA DX RT UPS complete all as specified and as directed by Engr-in- charge. Make - ETAON or as approved by GE. |
| 9 | Supply and fixing in replacement of UPS battery of capacity 12 V 42 Ah complete all as specified and as directed by Engr-in- charge. Make Exide/ Amaron or as approved by GE. Note: Necessary connection for battery with copper wire, lugs are deemed to be included in quoted rates. |
| 10 | Supply and fixing of condenser coil suitable for Precision AC (Model No LS 40 or equivalent as approvedby GE)complete all as specified and as directed by Engr-in- charge. Note: Cost of refrigerant gas are deemed to be included in quoted rates. |
| 11 | Supplyand erection Acousitic insulation with using 50mm UP TWIGA Glass wool sheet covered with RP Tissue paper and alumium perforated sheet of 28 Guagewith GI Channel complete including necessary fixing arrangement complete all as specified and as directed by Engr-in- charge |
| 12 | Supply and laying XLPE Cable of capacity 185 Sqmmx 3.5 Corecomplete all as specified and as directed by Engr-in- charge |
| 13 | Excavation in trenches not exc 1.5m wide and n.exc 1.5m in depthfor foundation / fixing pole / laying cable and pipe line etc or for man hole etc not exc 10 sqm on plan and getting out in soft / loose soilcomplete all as specified and as directed by Engr-in- charge |
| 14 | Returning filling in including spreading levelling, watering and well ramming in layers not exc 25 cm thick using suitable excavated soilcomplete all as specified and as directed by Engr-in- charge |
| 15 | Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting pointcomplete all as specified and as directed by Engr-in- charge |
| 16 | Supply and laying double wall corrugated (DWC) pipe suitable for cable protection of size 80mm dia complete all as specified and as directed by Engr-in- charge |
| 17 | Supply , installation, testing and commissioning in replacement of PN 16 Butterfly valves of 150mm dia (MS Pipe) duly insulated with companion flanges, nuts, bolts, gaskets etc as specified , Butterfly valves with cast iron body, seat of black nitrite rubber, nylon coated SG iron disc PTFE coated SS (AISI 410) shaft etc as required . These valve shall conforming to BS 5155, MSS SP 67 & API 609 and shall be desiged to fit without gasket between mating flanges including taking down old u/s valves etccomplete all as specified and as directed by Engr-in- charge |
| 18 | Supply and erection of auto air purge valve of 25mm diacomplete all as specified and as directed by Engr-in- charge |
| 19 | Supply , installation, testing and commissioning of set of 100mm dial type temp gauge with appropriate range & SS Valves and SS Tubing as specified and requiredcomplete all as specified and as directed by Engr-in- charge |
| 20 | Supply installation testing and commissioning of supply/return air diffusers/grills of extruded aluminium section duly powder coated with black volume control dampercomplete all as specified and as directed by Engr-in- charge |
| 21 | Supply and fixing of 25mm thick nitrile duct insulation . The thermal insulation shall be 25mm thick non fiberous, fire retardant closed cell conform to class O for fire propagation and class I for surface spread of flame and factory laminatedcomplete all as specified and as directed by Engr-in- charge |
| 22 | Supply and fixing of aluminium cladding 28 gauge to cover AC Duct complete with fixing by machine, screwcomplete all as specified and as directed by Engr-in- charge |
| 23 | Supply,testing and commissioning outdoor weather and vermin proof L.T.Panel board factory fabricated outdoor cubicle typetotally enclosed made out of 3.15 mm thick sheet metal enclosure with angle iron frame of suitable size, CPRI approved, IP-42for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel opening doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor FRLS PVC insulated cables of adequate size, dulywith painted one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour and bus bar rating 300Ampfor 3 phase &neutralmounted on epoxy insulator-01 Set including connecting the following.(i)Incoming MCCB4 pole , 415 Volts, 25 KA fixed type with thermal magentic relaseof capacty 160 Amps - 01 Nos |
| 24 | (ii)Outgoing MCCB4 pole , 415 Volts, 16 KA fixed type with thermal magentic relaseof capacty 63 Amps - 03Nos |
| 25 | (iii) Digital meter Amp and volt as per recommed by OEM((iv) LED Phase indicator lamps(RYB) - 1 set |
| 26 | Note : (a) Necessary busbar of suitable capacity and extension of studs for fixing of Incoming and outgoing cables as required as per site are deemed to be included in the quoted rate (b)PCC foundation concreteand coping shall be as per OEM recommendation. |