Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 18-12-2025 | BOQ | BOQ | 26-12-2025 |
| Sl. No. | Item Description |
| 1 | Supply, Install, Commissioning & Testing of Cold Storage Unit of Refrigeration Capacity 2.8 KW or higher (1W + 1S) with a desired temperature range of 18 to -20 (Minus 20) Deg C perfectly suitable/compatible for room with minimum dimensions 2.5 Mtr x 2.5 Mtr x 2.75 Mtr (height) complete all as specified & as directed & to the entire satisfaction of the Engr-In-Charge. Make : BLUESTAR/HITACHI/DAIKIN/VOLTAS/CARRIER |
| 2 | Detailed technical specification of the Cold Storage Unit is as follows : (a) Ambient Temp Range - 42 Deg C(b) Desired Temp Range - 18 to -20 Deg C (During defrost period temp shall be around -14 Deg C)(c) Product to be stored - Meat, Fish & other perishable food/product(d) Pull Down Temp - 24 Hrs(e) PUF Density - 40 Kg per Cum(f) U Factor - 0.05 BTU/Hr/Sqft/Deg F(g) Material of Insulation for wall & ceiling Insulation & thickness - R PUF, 100 mm thick PUF Panels, C 5 Cyclopentene Panels(h) Serration on Panel - On both sides(j) Floor Insulation & Thickness - 100 mm PUF Insulation shall be covered with Bitumen + Tar Felt & finally finished with covered with 75 mm thick PCC.(k) Panel Finish - Inside & Outside PP(l) Door Type & Size - 100 mm thick swing door, flush fit type with clear opening of 34\" x 78\" with all standard fittings & pad lock system, Finish PP/PP.(m) Type of Refrigeration Unit - Split Type(n) Type of Cooling - Dxtype(o) Required Refrigeration Capacity - 2.8 KW or higher x 2 Sets (1 Working + 1 Standby)(p) Type of Refrigerant - R 404 A or latest |
| 3 | (q) Type of Compressor - Hermetic, Recip(r) Type of Condersor & Make - Air Cooled, Emerson make fully loaded or as per OEM.(s) Type of Evaporator Units - Air Cooled, Ceiling Suspended, PPGI finish, Make Patton or as per OEM.(t) Controller - Microprocessor based digital temp indication cum controller with fault/trip indication.(u) Type of Light - LED 02 Nos(v) Sequential Controller - Included to operate the units at pre-determined time intervals (4/6/8 hours) & to operate the standby unit in case of emergency.(w) Power Supply - 415 V, 3-Ph, 50 Hz(x) Panel Features :Cam Locks for Jointing of Panels.Flush-in-Type Door with Anti-Condensation Door Heater / Digital IndicatorPanels must be Modular, Pre-Fab Type which can be assembled at site & also cane be shift after dismantling from one place to another & re-assembled at other site.(y) Refrigeration Unit Features :Low Power Consumption Units.Light Weight/SleekSleek Indoor Units |
| 4 | IMPORTANT NOTES : 1) Design / Drawing / BOM / technical specifications of the complete Cold Storage Plant showing the layout & other details etc. is to be obtained from OEM / Auth Channel Partner / Supplier & is to be got approved from Engr-in-charge & GE before placing final order. 2) Necessary Test/Guarantee/Warrantee certificates to be submitted in original to the Engr-in-Charge. 3) The complete installation, commissioning & testing of the complete Cold Storage Plant is to be got done from the OEM or their auth Rep/Sister Concern/Channel Partners only & reports submitted to Engr-In-Charge in duplicate.4) The cost of periodical/routine servicing/maintenance including repairs/replacement of spare parts etc. (as & when required) including periodical checking of the complete System for the complete defect liability period (2 Years from certified date of completion of work) from the authorized service dealer/rep as & when required/due is deemed to be included in the unit quoted rates.5) Detailed Technical Specifications w.r.t. the Items/Eqpts/System of the complete Cold Storage Plant has been highlighted above, same to be adhered to by the Contr/Firm. Contr/Firm is therefore required to visit the site of work for any doubts/clarifications w.r.t. specifications/qty etc. before quoting of the Tender. Any query/clarifications etc. after conclusion of the Contract shall NOT be entertained & decision of the AO shall be final & binding.6) Quoted rates are deemed to be inclusive of the following :(i) Copper Piping, Interconnecting Cabling, Refrigeration Controls, Panel Accessories, First Change of Refrigerant.(ii) Floor Insulation with 100 mm thick PUF covered with Tar Felt & Bitumen etc.(iii) Guarantee for a minimum period of 24 Months from the date of commissioning. |
| 5 | (iv) Related Civil Works, Opening & finishing of Civil Walls for Copper Piping.(v) Supply, Laying & Testing of Incoming Power Cables upto eachODU with MCCB/MCB controls to the entire satisfaction of Engr-In-Charge.(vi) MS Supports for Refrigeration Indoor Units & Ceiling PUF Panels.(vii) Civil Pedestal/MS Structure for Outdoor Units.(viii) Cold Storage Room Internal Lighting.(ix) PVC Strip Curtain near Cold Room Door.(x) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. |
| 6 | Excavation in trenches by mechanical or any other means n.exc 1.5m wide and n.exc 1.5m in depth for laying of pipe and getting out in hard dense soil complete. IMPORTANT NOTE : 1) The requirement of JCB (if any) for cutting the hard standing/PCC/WBM road surface or during earthwork is deemed to be included in the unit quoted rates. 2) If any damage to any Cable of Air Force/BSNL/MES etc. or to any Pipe lines develops/occurs during execution of the works then the same shall be made good by the Contr to the entire satisfaction of the concerned Dept/Section & the costs of the same is deemed to be included in the unit quoted rates.3) Quoted rate is also deemed to be inclusive of clearing/removing/cutting of vegetation/tree branches/small to medium plantings/bushes etc. so as to facilitate successful completion of the work. No extra/addl payment shall be allowed to the Contr in this regard.4) The contractor/firm is required to visit the site prior to quoting of the subject items/ work so as to ascertain the actual ground requirements. Any further query at a later date shall not be entertained & responsibility of the same shall rest on the contractor/ firm. |
| 7 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick. |
| 8 | Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point. |
| 9 | M&L for HDPE DWC (Double Wall Corrugated) Pipe ofrating 450 N, ISI marked with Min OD 77/75 mm & Min ID 63 mm, Orange colour for LT UG Cable protection with & including Couplers with rubber rings & RR & NFP properties/features confirming to IS 16205 Part 24:2018 & IEC 61386 Part 24:2007 complete all as specified & as directed by the Engr-In-Charge. Make : Supreme/Astral/Finolex/Polycab. |
| 10 | M&L for earthing complete with Copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to Copper earth strip 20 x 3 mm by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with suitable funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete all as specified and as directed by the Engr-in-Charge. |
| 11 | M&L for earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to GI earth strip 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with suitable funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete all as specified and as directed by the Engr-in-Charge. IMPORTANT NOTES for Item Nos 6 & 7 : On completion of the complete work/job the Contr is to perform earth resistance tests for each earthing job in the presence of the Engr-In-Charge or his rep & submit test certificates duly signed & certified. If the test results are not found satisfactory or not within the permissible limits of relevant Standards/IS then the job is to be redone without any extra cost to the Dept till the results are satisfactory. |
| 12 | M & L for laying earth continuity conductor or main earthing lead of 20x3 mm copper strip, fixed to wall on batten or recess or chasses or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required all as directed and specified. |
| 13 | Supply and laying in trenches/through pipes or bare in road crossings/ paths /drains /ducts /floors /along poles/ walls/ ceilings/ equipments etc. Cable Under ground, armoured, XLPE insulated with stranded aluminium conductor, 1100 Volts grade ofcross sectional area, 3.5 Core 50 Sqmm incl connecting with suitable glands, lugs etc complete all as specified and directed by the Engr-in-Charge. Make: Havells/Finolex/Polycab/Gloster |
| 14 | M & L for laying earth continuity conductor or main earthing lead of 32x6 mm galvanised iron strip, fixed to wall on batten or recess or chasses or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required all as directed and specified. |
| 15 | M&Lfor GI pipe light grade with all running fittings (ISI Marked), laid in trenches, under road or fixing on wall/pole/crossing drain/nallah etc. of bore 40 mm complete all as specified and directed. Make : TATA/JINDAL/PRAKASH. |
| 16 | Supply, install, commissioning & testing of MCCB enclosure with inbuilt Neutral Link for TPN system, IK-08, IP-30 Protection level, Mounting holes for easy wall installation/mounting, Louvers for better heat dissipation with & including MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, 36 KA breaking capacity & of rating 168-250A incl electric connection complete all as specified & as directed to the entire satisfaction of Engr-In-Charge. Make of MCCB Enclosure : Cat No CM91003OOOO of Make L&T or techno-commercially equivalent of ABB/SIEMENS/LEGRAND. Make of MCCB : Cat No DZ4F0250DXD1AOOOO of Make L&T or techno-commercially equivalent of ABB/SIEMENS/LEGRAND.IMPORTANT NOTE: 1) Design / drawing / BOM of the Panel Board incl all accessories showing the dimensions is to be obtained from the Manufacturer / Supplier & is to be got approved from the Engr-In-Charge & GE before placing final order to the manufacturer.2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.3) Necessary PCC foundation/plinth/fixing arrangements incl MCCB spreader links (if any) shall be as per the recommendations of OEM & cost of the same is deemed to be included in the quoted rates. |
| 17 | Supply, install, commissioning & testing of Outdoor Type AMF Panel suitable for DG Set of upto 75 KVA of size 1200 mm (height) x 1000 mm (breadth) x 500 mm (depth) (minimum dimensions) factory fabricated CPRI (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming/Outgoing ACB/MCCB rating (as applicable). The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.0 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl suitable PCC (1:3:6) type C-2 foundation , necessary earthwork (if any) complete all as specified & as directed with & incl the following accessories : SEB I/C : MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 36 KA & of rating 108 to 160 A - 01No. Cat No : DZ1F0160DXD1AOOOO of Make L&T or techno-commercially equivalent of ABB/LEGRAND/SIEMENS. |
| 18 | DG I/C : MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 36 KA & of rating 108 to 160 A - 01No. Cat No : DZ1F0160DXD1AOOOO of Make L&T or techno-commercially equivalent of ABB/LEGRAND/SIEMENS.AMF MAIN O/G : MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting, suitable for isolation, having breaking capacity 36 KA & of rating 108 to 160 A - 01No. Cat No : DZ1F0160DXD1AOOOO of Make L&T or techno-commercially equivalent of ABB/LEGRAND/SIEMENS. COMPACT ENCLOSED ATS (Automatic Transfer Switch) suitable for inside panel mounting & I-O-II operation, 4 Pole, 160 A, confirming to IEC 60947-6-1 - 01 No complete with following features/specifications : (i) Double-Break Contact System offering High Short-time Withstand.(ii) Ample Space for Cable Termination.(iii) Ease of Generator Control (ON-OFF, Cooling Cycle Self-Test). |
| 19 | (iv) Cyclic Event Logger.(v) Priority Source Selection.(vi) Adjustable Time Delay (0.1 Sec to 3 Hrs).(vii) Suitable for 3-Phase as well as 1-Phase sources.(viii) Protections - UV/OV, Phase Sequence, Single Phasing, Frequency.(ix) Terminal Shrouds, Phase Barriers & Source Separator etc.Make : Cat No CK90162BSOO of make L&T or techno-commercially equivalent of ABB/Siemens.The size/rating of all the connected accessories viz. MFM, RYB Indication Lamps, MCBs, 200/5 CT Coils, DG Start/Stop Relay, 12V/10A Battery Charger, OV/UV Relays, 230V Aux Contactor, DG Set Running Indication Lamp, Load ON Mains/DG Indication Lamps etc. of the AMF Panel shall be as per OEM & in conformity with the I/C & O/G MCCBs duly provided with BYPASS system/arrangement complete. |
| 20 | IMPORTANT NOTES : 1) Design/drawing/BOM of the AMF panel showing the dimensions is to be obtained from DG SET/Panel board manufacturer/Auth supplier & is to be got approved from Engr-in-charge & GE before placing final order to the manufacturer.2) The electrical connection of digital Multi Functional Meter in the AMF panel is to be done from load side so that monitoring of various parameters viz. Voltage, Current, KW, KVA, power factor, frequency etc. can be done for both SEB mains & DG mains.3) The cost of periodical/routine servicing including repairs/replacement of spares including periodical checking of the complete AMF panel for the complete defect liability period from the authorized Service Dealer as & when required/due is deemed to be included in the unit quoted rates.4) The complete installation, commissioning & testing of the AMF Panel is to be got done from the OEM or their auth Rep/Sister Concern/Channel Partners only.5) Anything missed out in the technical specifications but technically required for efficient working of the AMF Panel is deemed to be included in the quoted rates.6) Necessary PCC foundation/plinth shall be as per the recommendations of OEM & cost of the same is deemed to be included in the quoted rates.7) The approximate distance between the DG Set & the AMF Panel shall be within 20 Mtrs & the cost of control cabling etc. from DG Set to the AMF Panel is deemed to be included in the unit quoted rates.8) The DG Set & AMF Panel shall be completely suitable for switching ON the DG Set whenever EB Supply goes OFF & transfer the load to DG & vice-versa in the event of resumption of EB Supply.9) The contractor/firm is required to visit the site prior to quoting of the subject items/ work so as to ascertain the actual ground requirements. Any further query at a later date shall not be entertained & responsibility of the same shall rest on the contractor/ firm. |
| 21 | M&L for earthing complete with Copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to Copper earth strip 20 x 3 mm by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with suitable funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion incl taking down old unsv earthing assy complete all as specified and as directed by the Engr-in-Charge.NOTE : On completion of the complete work/job the Contr is to perform earth resistance tests for each earthing job in the presence of the Engr-In-Charge or his rep & submit test certificates duly signed & certified. If the test results are not satisfactory or not within the permissible limits of relevant Standards/IS then the job is to be redone without any extra cost to the Dept till the results are satisfactory. |
| 22 | M & L for laying earth continuity conductor or main earthing lead of 20x3 mm copper strip, fixed to wall on batten or recess or chasses or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required all as directed and specified. |
| 23 | M&Lfor GI pipe light grade with all running fittings (ISI Marked), laid in trenches, under road or fixing on wall/pole/crossing drain/nallah etc. of bore 40 mm complete all as specified and directed. Make : TATA/JINDAL/PRAKASH. |
| 24 | Supply only Ceiling Fans complete with blades, down rods, electronic regulator (compatible for BLDC Fans) & accessories, 230 V, 1200 mm sweep, min air delivery 210 CFM with service value 6.00 BEE, 5 Star rated with BLDC motor. Make : HAVELLS/BAJAJ/USHA/KHAITAN. Note :- (i) Anything missed out in the technical specifications but technically required for efficient operation of the E/Fan is deemed to be included in unit quoted rates. (ii) Installed Ceiling Fans Guarantee/Warranty cards duly signed by the OEM/Dealer should be submitted to the Engr-in-Charge. |
| 25 | Supply only Exhaust fan, copper wound, PVC body with automatic back shutter louvers 150 mm sweep, 1350 RPM or more, Air Delivery not less than 280 CMH, single phase, 240 Volts, AC, 50 Hz, Noise level < 34 dB with 2 Yrs Guarantee. Make : Havells, Cat No: Ventil Air - DX White or techno-commercially equivalent in Usha/Bajaj/Khaitan. |
| 26 | Supply only Exhaust fan, copper wound, PVC body with automatic back shutter louvers 250 mm sweep, 1200 RPM or more, Air Delivery not less than 860 CMH, single phase, 240 Volts, AC, 50 Hz, Noise level < 44 dB with 2 Yrs Guarantee. Make : Havells, Cat No: Ventil Air - DX White or techno-commercially equivalent in Usha/Bajaj/Khaitan. |
| 27 | Supply only Exhaust fan, copper wound, Metal body with Bird Guard, Double Ball Bearings 230 mm sweep, 1400 RPM or more, Air Delivery not less than 860 CMH, single phase, 240 Volts, AC, 50 Hz, Noise level < 45 dB with 2 Yrs Guarantee. Make : Havells, Cat No: Ventil Air - DB (Pista Green) or techno-commercially equivalent in Usha/Bajaj/Khaitan. |
| 28 | Supply only Exhaust fan, copper wound, Metal body with Bird Guard, Double Ball Bearings 300 mm sweep, 1400 RPM or more, Air Delivery not less than 1850 CMH, single phase, 240 Volts, AC, 50 Hz, Noise level < 45 dB with 2 Yrs Guarantee. Make : Havells, Cat No: Ventil Air - DB (Pista Green) or techno-commercially equivalent in Usha/Bajaj/Khaitan. |
| 29 | Supply only Wall Fan High Speed, PVC body suitable for wall mounting, 300 mm sweep, 2350 RPM or more, Air Delivery not less than 70 CMH, adjustable upward & downward tilt, with safety feature of motor protection through thermal overload protection device, oscillation degree 60, single phase, 240 Volts, AC, 50 Hz with & including 2 Years Guarantee. Make : Havells, Model : Swing Off-White (High Speed) or techno-commercially equivalent in Usha/Bajaj/Khaitan. |
| 30 | Supply only Vertical type Storage electric water heater (Geyser) of 25 Ltrs capacity, Tank made of ultra thick super cold rolled steel plates with high density PUF insulation, 2 KW, 230 V, Single Phase, 50 Hz, AC, BEE 5 Star rated, suitable for a pressure rating of 0.8 MPa Bar with 7 years warranty on inner tank, 4 years on heating element & 2 year comprehensive warranty with & including connected accessories and 2 Nos anchor fasteners of size as per manufacturer instructions incl steel braided hose 2 Nos. Model - Monza DX, Cat No: GHWAMGTWH025 of Make Havells or techno-commercially equivalent in Racold/ Bajaj. Note for Item Nos 4 to 10 :- (i) Anything missed out in the technical specifications but technically required for efficient operation of the C/Fan, E/Fan, W/Fan, Geyser is deemed to be included in unit quoted rates. (iii) C/Fan, E/Fan, W/Fan, Geyser Warranty/Guarantee cards to be submitted to the Engr-in-Charge. (iii) Design/Drawing/Technical catalogue/specifications along with comparative Rate Analysis to be submitted to the Engr-In-Charge for Make/Sample approval of items whereever equivalency of Item(s) is concerned other than specified Make/Model/Cat/Part Ref concerned before making final order to the manufacturer/dealer/supplier. |
| 31 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard / dense soil. |
| 32 | M&L for hardcore of gauge n exc. 63 mm of broken stone boulders, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface. |
| 33 | M&L for PCC 1:4:8 type D2 (using 40mm graded stone agg) 75mm thick as in floor sub base etc as specified directed. |
| 34 | M& L for Pre-cast cement concrete block masonry with type C1 (1:3:6) using 20 mm graded stone aggregate solid blocks, exc. 10 cm in width and setting in cement mortar 1:6,complete all as specified and as directed. |
| 35 | M&L for rendering 15 mm in Cement Mortar 1:4 on fair faces of brick work or concrete surface walls finished fair and even complete all as specified and as directed. |
| 36 | M&L for preparation of new surfaces plastered or unplastered walls and applying two coats of cement base paint over a priming coat all as specified and directed. |
| 37 | Removing excavated material (soils) exceeding 1.50 km but not exceeding 5 km and depositing where directed all as specified and directed. |
| 38 | S&Fpowder coatedaluminium frame for doors, windows, ventilators, partitions etc with one or more rebates including joining cleat for fixing etc. complete all as specified. |
| 39 | S&F powder coating anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, 3 Nos hinges, anodised aluminum snap beading screws etc. complete all as specified |
| 40 | S&F250 mm aluminum alloy anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy complete all as specified. |
| 41 | S&F of 100mm Aluminum anodised barrel tower bolts of extruded section complete all as specified. |
| 42 | S&F 140mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor |
| 43 | S&F 4mm thickSheet glass, ordinary quality and glazing with oil putty/ glazing clips in square n exc 0.5sq. m in each pane |
| 44 | S& F 12mm Particle board, medium density, flat pressed, single layer type or three layer type with BWR type adhesive, fixed with screws to timber frame work |
| 45 | M & L for surface point wiring with two single core 1.5 sqmm PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with multi stranded copper conductor drawn through and including non-metallic PVC rigid conduit (medium grade), ISI marked with all fittings and accessories ISI marked incl provision of 1.5 sqmm PVC insulated, multistranded, unsheathed, copper conductor cable, FRLS, ISI marked as earth continuity conductor (green in colour) & incl fixing of modular metal flush boxes of appropriate size & thickness fixed flush to wall for mounting switch, sockets etc. with including cutting chases (if any) for conduits & sinkings for modular boxes & making good the disturbed surfaces, matching to the existing one etc. complete all as specified & as directed for the following : Make of cable : Havells/Polycab/Finolex/KEI(a)One Light/fan etc. point controlled by one switch 5/6 Amps. |
| 46 | (b)One switch socket outlet point 5/6 Amps on independent board. |
| 47 | Description all as per Item No-1 above but with FRLS PVC insulatedcopper conductor cable of size 2.5 Sqmm and 2.5 Sqmm for earth continuity conductor green in colour for 16A switch socket complete. |
| 48 | M & L for surface sub-main wiring alongwith earth wire of size (2 x 2.5) sq. mm + (1 x 2.5) sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non-metallic PVC conduit (medium grade) with all fittings and accessories ISI marked for conduits & sinkings for modular boxes & making good to walls, floors etc. complete all as specified & as directed. Make of cable : Havells/Polycab/Finolex. NOTE for Item Nos 1 to 3 : 1) Two runs of PVC wire, one run of earth wire & one run of PVC rigid conduit (medium grade) will be measured as one length. 2) Modular metal flush boxes (if req) shall be measured & paid separately. 3) Cutting chases & making good the disturbed surfaces (if any) is deemed to be included in the unit quoted rates. 4) Cost of PVC clamps with fixing screws for fixing on walls &/or PVC cable ties etc. for fixing on steel support members (if any) is deemed to be included in the unit quoted rates. |
| 49 | S & F Modular switch, one way, 6 Amp, 1 Module, 240 volt complete all as specified and as directed. Cat No : ACVSXXW061, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab |
| 50 | S & F Modular switch, one way, 16 Amp, 1 Module, 240 volt with Indicator complete all as specified and as directed. Cat No : ACVSXXW161, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab |
| 51 | S & F Modular shuttered socket outlet 3 Pin, 6 Amp, 2 Module, 240 volts, ISI marked complete all as specified and as directed. Cat No : ACVKSWW063, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab |
| 52 | S & F Modular shuttered socket outlet 3 Pin, 6/16 Amp, 2 Module, 240 volts, ISI marked complete all as specified and as directed. Cat No : ACVKCWW163, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/PolycabNote for Item Nos 4 to 7 : Design/Drawing/Technical catalogue/specifications along with comparative Rate Analysis to be submitted to the Engr-In-Charge for Make/Sample approval of items whereever equivalency of Item(s) is concerned other than specified Make/Model/Cat/Part Ref concerned. |
| 53 | Supply & Fixingand concealing modular metal flush boxsuitable for fixing switches/sockets of 3 modules all as directed. Make : VERONA (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab |
| 54 | Supply & Fixingand concealing modular metal flush boxsuitable for fixing switches/sockets of 6 modules all as directed. Make : VERONA (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab |
| 55 | Supply & Fixingmodular cover platesuitable for fixing switches/sockets of 3 modules all as directed. Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab |
| 56 | Supply & Fixingmodular cover platesuitable for fixing switches/sockets of 6 modules all as directed. Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/PolycabNOTE for Item Nos 8 to 11 : The make/model of modular metal flush boxes & modular cover plates shall be same as that of modular switches & sockets. |
| 57 | S&F ceiling rose surface PVC/ Polycarbonate, Isolated body with face Bakelite three terminal complete all as specified and directed. Make: Havells/Legrand/Anchor |
| 58 | S&F Surface and wall mounted LED batten 20 watts 4 feet long, extruded aluminium housing providedfor efficient heat dissipation & integrated electronic driver including connecting up with and including twin/three core twisted flexible cable of suitable size in flexible conduit all as specified and as directed. Make : LUKER, Cat No LT520P or techno-commercially equiv in Havells/Jaguar/Philips. |
| 59 | S & F ceiling/roof mounted energy saving, environment friendly, robust Die-Cast Aluminium Body + Toughened Glass LED High Bay IP 65 luminaire with high efficacy of rating 150 W, CRI > 80, CT>6000 K, Beam Angle - 120 degree, I/P Voltage Range 100-300 V, PF > 0.95, Luminous Efficiency > 100 Lumen/W, 10 KV Surge Voltage Protection, THD < 5%, integrated type with all accessories internally prewired and including connecting up with necessary fixing arrangements & electrical connection strictly keeping in view the Fire/Life safety aspects with & including 5 Years OEM Warranty on the fitting with & including flame proof flexible metallic conduit incl conneting accessories complete all as specified and as directed by Engr-In-Charge incl taking down old/unsv light fittings & depositing to MES Storeyard. Model - AVIOR, Cat No LOHY150 LN S 5Y (LENS TYPE) of make LUKER or techno-commercially equiv in Havells/Jaguar/Philips. |
| 60 | Supply, install, commissioning & testing of Industrial Type Air Circulators, metal body suitable for wall mounting, 600 mm sweep, 1440 RPM or more, Air Delivery not less than 280 CMH, Noise Level 60 to 65 dB, double Ball Bearings, adjustable upward & downward tilt, with safety feature of motor protection through thermal overload protection device, single phase, 240 Volts, AC, 50 Hz with & including 2 Years Guarantee and connecting up complete including provision of cable 3 core of suitable size from ceiling rose to fan in flexible hose & making good the disturbed surfaces (if any) complete all as specified & as directed incl taking down old/unsv light fittings & depositing to MES Storeyard. Make : Havells, Model : Turbo Force Wall (Single Phase) or techno-commercially equivalent in Usha/Bajaj/Khaitan. |
| 61 | Supply, install, commissioning & testing of Wall Fan High Speed, PVC body suitable for wall mounting, 300 mm sweep, 2350 RPM or more, Air Delivery not less than 70 CMH, adjustable upward & downward tilt, with safety feature of motor protection through thermal overload protection device, oscillation degree 60, single phase, 240 Volts, AC, 50 Hz with & including 2 Years Guarantee and connecting up complete including provision of cable 3 core of suitable size from ceiling rose to fan in flexible hose & making good the disturbed surfaces (if any) complete all as specified & as directed. Make : Havells, Model : Swing Off-White (High Speed) or techno-commercially equivalent in Usha/Bajaj/Khaitan.Imp Note for Item Nos 13 to 16 : 1) Design/Drawing/Technical catalogue/specifications along with comparative Rate Analysis to be submitted to the Engr-In-Charge/GE for Make/Sample approval of items whereever equivalency of Item(s) is concerned other than specified Make/Model/Cat/Part Ref concerned before placing order to the Manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. 3) The approximate height of installation/fixing of the High Bay LED fittings is around 7 to 8 Mtrs & that of Industrial type wall mounted Air Circulators is 4 to 5 Mtrs from Ground/FFL. 4) Contr is required to take all the safety precautions incl any type of ladders/scaffolding work & cost of the same is deemed to be included in the unit quoted rates. 5) Purchase Vouchers & Necessary test certificates i.e LM-79, LM-80 reports to be submitted in Original to the Engr-in-Charge for checking & record. 6) Cost of transportation of old/unsv/existing fittings/fixtures to MES Storeyard is deemed to be included in the unit quoted rates. |
| 62 | S & F TPN DB, 8 Way, IP43, IK09, Metal double door type 415 volts fitted with busbar and blanking plates, neutral link and making good making good the disturbed surfaces with all other accessories including necessary connection all as specified and directed by Engr-in-Charge. Make-L&T/LEGRAND/SIEMENS/ABB. |
| 63 | S&F MCB, TPN, C-Series 415 Volts of capacity 20-32 Amps with breaking capacity 10 KA all as specified and dircted by Engr-in-Charge. (1W+1S) Make-L&T/LEGRAND/SIEMENS/ABB. |
| 64 | S&F MCB, SPN, C-Series 240 Volts of capacity 6-32 Amps with breaking capacity 10 KA all as specified and dircted by Engr-in-Charge. Make-L&T/LEGRAND/SIEMENS/ABB. |
| 65 | S&F MCB, SP, C-Series 240 Volts of capacity 6-32 Amps with breaking capacity 10 KA.Make-L&T/LEGRAND/SIEMENS/ABB. |
| 66 | M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to galvanized iron wire 4 mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete. Make of GI Pipe : TATA/Jindal/PrakashNOTE : On completion of the complete work/job the Contr is to perform earth resistance tests for each earthing job in the presence of the Engr-In-Charge or his rep & submit test certificates duly signed & certified. If the test results are not satisfactory or not within the permissible limits of relevant Standards/IS then the job is to be redone without any extra cost to the Dept till the results are satisfactory. |
| 67 | M & L for laying earth continuity conductor or main earthing lead of 4 mm dia GI wire, fixed to wall on batten or recess or chasses or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required all as directed and specified. |
| 68 | M&Lfor GI pipe light grade with all running fittings (ISI Marked), fixed on Perimeter/Street light PCC poles etc. of bore 15 mm complete all as specified and directed. Make : TATA/JINDAL/PRAKASH. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail