| 1 | Opening (De-assembling) of the ceiling fan, 1200/1400mm sweep for repair, removing existing burnt winding, rewinding the same with super enameled copper winding wire of appropriate gauge, slot insulation, heat varnishing, greasing and re-assembling including replacement of split pin and Replacing flexible 3 core cable of size 1.5 sqmm with copper conductor up to 1.5 mtr long and testing complete all as specified and directed. Note:- (i) Contractor shall collect the Ceiling fan for repair from Store Yard of AGE (I) Dhana and fix the repaired fan on the location given by Engineer-in-charge. |
| 2 | Opening (De-assembling) of the BLDC ceiling fan, 1200mm sweep for repair, removing existing burnt winding, rewinding the same with super enameled copper winding wire of appropriate gauge, PCB repair and re-assembling including replacement of split pin and Replacing flexible 3 core cable of size 1.5 sqmm with copper conductor up to 1.5 mtr long and testing complete all as specified and directed. Note:- (i) Contractor shall collect the Ceiling fan for repair from Store Yard of AGE (I) Dhana and fix the repaired fan on the location given by Engineer-in-charge. |
| 3 | ..ditto..all as per item (1)above but for exhaust fans of 200 to 300 mm sweep and any size complete all as specified and directed. |
| 4 | ..ditto..all as per item (1)above but for exhaust fans of 450mm sweep and any size complete all as specified and directed. |
| 5 | S&F in replacement ball bearingsuitable for ceiling Fan 1200/1400 mm complete all as specified and directed. Make- SKF/NBC |
| 6 | S&F in replacement capacitor 2.5 MFD. ccomplete all as specified and directed. Make- Havells, Falcon, Epcos |
| 7 | S&F in replacement capacitor 4 MFD. complete all as specified and directed. Make- Havells, Falcon, Epcos |
| 8 | S&F in repair MS hanging clamp with rubber bush, bolts, nuts & washer with split pin suitable for 1200/1400 mm sweep ceiling fan complete all as specified and directed. |
| 9 | Taking down of ceiling fan 1200 mm sweep from existing position/hook, cleaning, servicing, greasing, oiling and re-fixing on same position complete all as specified and directed. |
| 10 | Taking downexhaust fan of size 300/380/450 mm sweep from existing position, cleaning, servicing, greasing, oiling and re-fixing on same position complete all as specified and directed. |
| 11 | M&L for preparation of surfaces of ceiling fan including blade and applying one coat of white/brown synthetic enamel paint including writing MES number with black synthetic enamel paint complete all as specified and directed. |
| 12 | M&L for preparation of surfaces of exhaust fan of size 300/380/450 including blade, frame/louver and applying one coat of black synthetic enamel paintincluding writing MES number with white synthetic enamel paint complete all as specified and directed. |
| 13 | S&F in replacement rubber reel suitable for ceiling fan of any make and size complete all as specified and directed |
| 14 | S&F celing fan down rod of 300 mm long suitable for ceiling fan fixed on replacement of existing down rod complete all as specified and directed. |
| 15 | S&F celing fan down rod of 600 mm long suitable for ceiling fan fixed on replacement of existing down rod complete all as specified and directed. |
| 16 | S&F celing fan clamp made out from 2x32mm flat iron strip 450 mm long moulded with required shape as per site requirement and necessary welding work for hook made out from 12 mm round bar for hanging of the ceiling fan complete including taking down old u/s clamps all as specified and directed by Engr in charge. |
| 17 | S&F, in repair, PVC canopy set (Upper & Lower) suitable for ceiling fans complete all as specified and directed. |
| 18 | Disconnecting carefully water and electric connection from storage type water heater of 25 /50 Ltr cap of any make and dismantling for repair by taking out the syphon assembly of thermostat, heating elementand cleaning,de-scaling the inner tank by de-scaling chemical compound including soldering, brazing the inner tank if required, re-assembling the geyser after cleaning & servicing incl replacement of flexible 3 core cable of size 2.5 sqmm with copper conductor up to 1.5 mtr long andre-fixing in existing position complete all as specified and directed. Note:- (i) Heating element, thermostat, air release valve, safty valve, indicating lamp and syphone assembly shall be measured and paid under relevant items as \"Supply Only\". (ii) The rate quoted are deemed to include cost of soldering/brazing work and Glass wool superior qualityif required at site. |
| 19 | Supply only, heating element of 1.5 KW with circular or triangular base suitable for existing entry of geysers complete all as specified and directed. |
| 20 | Supply only, heating element of 2 KW with circular or triangular base suitable for existing entry of geysers complete all as specified and directed. |
| 21 | Supply only, thermostat assembly for geyser, tempetrature setting up to 85 degree centigrade, ISI marked complete all as specified and directed. |
| 22 | Supply only, indicating lamp suitable for existing slot of geyser complete all as specified and directed. |
| 23 | Supply only,safety valve for geyser chromium plated brass 15 mm dia all as specified and directed. |
| 24 | Taking downunserviceable PVC connections for cold water of geyser and supply and fixnew PVC heavy duty connection 15mm size with PTMT nuts on both ends of length 450mm with two washers, suitable for cold water connection to geyser all as specified and directed. |
| 25 | Ditto all as per item No (22) above but for hot water connection 15mm size for Geyser |
| 26 | S&F, in repair,semi circular bottom cover plate of 25/50 ltr capacity geyser duly painted of appropriate make complete all as specified and directed. |
| 27 | Supply and fix in replacement inner stainless steel dome/glass led of geyser of capacity 25 Ltrs complete as per sample to match original patterns and shape complete all as specified and directed by Engr in charge. |
| 28 | Supply & fixceilling fan complete with blades, down rods, electronic regulator and accessories, 230 volt, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE 5 Star rated with brushless direct current motor (BLDC) complete all as specified and directed by Engr in Charge. Note : Old u/s existing C/F deposited in E/M store yard for further repairing work or for BER process. |
| 29 | Supply & fixexhaust fan, steel body AC single phase 230 volt of size 300 mm sweep with blades and frame and louver complete including making hole if not available at site complete all as specified and directed by Engr in charge. (New Fan Provision as per Map Scale) Note : Old u/s existing Exhaust fan any size any make should be deposited in E/M store yard for BER disposal if available at site. |
| 30 | Supply and fix in replacment of electric water heater storage type with glasslead inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 star rated complete with all accessories such as safety valve, thermostate, NRV connection pipe complete all as specified and directed by Engr in Charge. Note : Old u/s water heater any size any make should be deposited in E/M store yard for repairing purpose or to declared BER. |
| 31 | S&F in repair exhaust fans AC, single phase, 230/240 volts of size 300 mm sweep PVC body with louver Complete all as specified and directed Note: Old/Unserviceable fans shall be deposited in MES store. |
| 32 | Supply and fix water heater instant type capacity 3 liters, 230volt, AC, thermoplastic body cover, with power on/off indicator lamp complete all as specified and directed. |
| 33 | Supply and Fixing MCB DB single door SPN2 way, 240 Volt, complete all as specified and directed.. |
| 34 | Supply and Fixing MCB SPN 32 Amps, 240 Volts, C Curve with breaking capacity 10 KA, complete all as specified and directed. |
| 35 | Material and labour for sub main wiring with 2 x 4 Sq mm PVC insulated single core unsheathed stranded copper conductor drawn in and including PVC casing capping of suitable sizeISI marked including continuous running earth wire by 4Sqmm PVC unsheathed single core stranded copper conductor connected to common earth dolly complete all as specified and directed . |
| 36 | M&L for point wiring for 15 Amp power point with 2.5 Sqmm PVC FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC casing caping of suitable size as per site reqmt, ISI markedwith all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc all as per site requirements including stainless steel terminal boxesfor mounting of switches/ sockets/regulator etc and PVC FRLS insulated & unsheathed 1100 volt grade copper conductor, stranded 2.5 sqmm. cable as continuous earth lead connected to common earth dolly complete all as specified and colour coding of cables such as Phase -Red, Neutral – Black, and Earth – Green. Make for cable Anchor/Polycab / Plaza |
| 37 | S&F switch socket combination 5 in 1, 6 pin, 5/16 Amp, flush type universal, 240 V completeall as specified and directed by Engr in charge. |
| 38 | Supply & Fix in repair, PVC insulated and PVC sheathed copper conductor cable of size 1.5 Sqmm, 3 core, 1100 volts grade, multistranded, 240 Volt as per IS-694 complete all as specified and directed. |
| 39 | Material and labour for replacement of PCB circuit of BLDC fan suitable for 1200 mm sweep complete all as specified and directed by Engr in charge. |
| 40 | Supply & fix Plug Top 15A, 230 Volt, AC complete all as specified and directed by Engineer-in-Charge. |