| 1 | Supply and Fix electric driven Submersible pump set of capacity 40 HP having 60 meter head and discharge not less than 1980LPM with conforming to relevant IS with dynamic balance mixedflow impeller heavy duty, water lubricant bearing including vibration free suction strainer to prevent the entry of foreign materials mixed and with the water lubricant of suitable size and suitable operation on voltage from 300 volt to 440 volt complete with and including 40 meter long submersible flatcopper cable of size 16 sqmm 3 core using suitable size necessary clamp of SS steel and steel nuts, bolts and washers and of suitable capacity star delta starter completeall as specified and directed - 05 Nos. |
| 2 | Supply and Fix electric driven Submersible pump set of capacity 25 HP having 60 meter head and discharge not less than 1550 LPM with conforming to relevant IS with dynamic balance mixedflow impeller heavy duty, water lubricant bearing including vibration free suction strainer to prevent the entry of foreign materials mixed and with the water lubricant of suitable size and suitable operation on voltage from 300 volt to 440 volt complete with and including 40 meter long submersible flatcopper cable of size 16 sqmm 3 core using suitable size necessary clamp of SS steel and steel nuts, bolts and washers and of suitable capacity star delta starter completeall as specified and directed- 01 No. Note for item 1 & 2 :- (i) The pump shall be procured after taking the sample from site to meetthe compatibilityat site ie dia of pump. |
| 3 | Supply and fixing of pump set with motor of capacity 50 HP electrically driven horizontal end suction, centrifugal type confirming to IS-12469 1988 with CI casing, bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for continuous operation with \"range of operation 0% to 150% of rated capacity for 440V, 3 phase 50 Hz 65 meter Head and discharge not less than 600 LPMwith and including suitable size starter andnecessary foundation work as manufacturer\"s specification complete all as specified and directed. - 01 No |
| 4 | Supply and fix of pump set with motor of capacity 2 HP electrically driven horizontal end suction, centrifugal type confirming to IS-12469 1988 with CI casing, bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for continuous operation with \"range of operation 0% to 150% of rated capacity for 440V, 3 phase 50 Hz 15m Headand discharge not less than 310 LPMwith and including suitable size starter andnecessary foundation work as manufacturer\"s specification complete all as specified and directed .- 02 Nos Note for item No 3 & 4 :- Before procurement of the pump the parameter from site shall be taken to meet the requirement in the presence of Engineer-in-charge. |
| 5 | Supply and fixing spigot and socketedDuctile iron water tubing of 100 mm dia having cement mortar lining at inner surface and one coat of bitumenous paint at outer surfacemedium grade, ISI marked,class \"K-9\" laid on wall/roof/floor/trenches with proper alignment as per site requirement and carry out testing against leakage before filling the trenches etc complete all as specified and directed at site. |
| 6 | Supply and fixing spigot and socketedDuctile iron water tubing of150 mm dia having cement mortar lining at inner surface and one coat of bitumenous paint at outer surfacemedium grade, ISI marked,class \"K-9\" laid on wall/roof/floor/trenches with proper alignment as per site requirement and carry out testing against leakage before filling the trenches etc complete all as specified and directed at site. |
| 7 | Supply and laying Cast iron pipe of dia 100mm centrifugaly cast ISI marked conforming to relevant IS code with both ends flanged and drilled, including specials ,Class \"B\" , with including tee, bends, coller, tail piece, run lead jointsand other necessary accessories as required complete all as specified and directed. |
| 8 | Supply and fix MS flanged pipe 100mm NB heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer completeall as specified and directed. |
| 9 | Cutting in position existing cast iron main pipe line of size 150 mm dia, insertion of CI tee 200 x 200 x 150 mm bore for tapping out for filling OHT/UG sump including connected fittings i.e. CI Tee, collar, tail piece, run lead joints and necessary excavation, refilling and disposal of surplus material completeall as specified and directed |
| 10 | Cutting in position existing cast iron main pipe line of size 150 mm dia, insertion of CI tee 150 x 150 x 150 mm bore for tapping out for filling OHT/UG sump including connected fittings i.e. CI Tee, collar, tail piece, run lead joints and necessary excavation, refilling and disposal of surplus material completeall as specified and directed |
| 11 | Supply & fix CI Special for Bends. Tapers. Tee pieces (single & double branch) any type and angle/radius and straight connecting pieces but all ends flanged upto 150 mm complete all as specified and directed. |
| 12 | Supplying and fixingsluice valvewith flanged ends, cast iron body non rising type , brass spindle with nuts , class PN 1.6 suitable for 150mm (6\")dia ISI marked, conforming to IS 8329/ IS:14846, including all joints with rubber or fibre board / bolts/ nuts, weashers etc complete all as specified and directed |
| 13 | Supplying and fixingsluice valvewith flanged ends, cast iron body non rising type , brass spindle with nuts , class PN 1.6 suitable for 100mm (4\")dia ISI marked, conforming to IS 8329/ IS:14846, including all joints with rubber or fibre board / bolts/ nuts, weashers etc complete all as specified and directed |
| 14 | Supplying and fixing swing check reflex (non return) valve flanged type cast iron body, stainless steel hing pin (AISI410) gun metal body ring, rubber diskface, ISI Mark, PN 1.6, including all fixing material, accessories and testing against leakage all as specified and directed of 100 mm (4\") dia. |
| 15 | Supplying and fixing swing check reflex (non return) valve flanged type cast iron body, stainless steel hing pin (AISI410)gun metal body ring, rubber diskface, ISI Mark, PN 1.6, including all fixing material , accessories and testing against leakage all as specified and directed of 150 mm (6\") dia sizes complete all as specified and directed. |
| 16 | SupplyIing, fixing, tesing and commissioning for CI body Foot valve 100mm dia (4\" NB) swing type as per IS-4038 with matching flanges, nut, bolts & Gaskets etc, complete all as specified and as directed. |
| 17 | Construction of brick masonary valve chamber in repair of size 0.9mx0.9mx 1.0 mtr (internal diamension) above ground level 30 mm suitable for 100 mm dia sluice valve, 15 cm thick foundation using PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) over 15 cm thick hardcore, 23 cm thick brick wall bults in cement and sand motor 1:4, 15 cm thick internal and external plaster including top floor in cement and sand motor 1:3, finished even and smooth, without using extra cement, 3mm thick mild steel platecover on 50 mm x 50 mm x 6 mm MS angle iron frame embeded in PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) coping having rectangular hinged opening of size with locking arrangement & handle made out of 25 cm dia MS round bar, hold fast etc, applying one coats od red oxide primer and two coats of synthetic enemelled paint to all steel surfaces and earth work in any type of soil including disposal of surplus soil to a distance not ex 50 mtr complete complete all as specified and directed. |
| 18 | Supply and Fixing of Star delta starter for the pump of capacity 10 HP conforming to IS: 13947, KIEC 60947-1 suitablefor operation in AC, three phase, 50 Hz (+5%) and 415 V (+10%) including 3 pole magnetic contactor with under volatge release- 3 Nos, CT operated Ammeter(65mm dia), Voltmeter(65mm dia), voltmeter selector switches, Miniature circuit breaker, THermal overload relay, Air break contactors suitable for next standard higher KW rating, Single phasing preventor, dry running preventor, and On/Off push button switches, wiring with 1 sqmm/ 4 sqmm copper pvc insulated cable, powder coated vermin proof box, including the capacitor complete all as specified and directed. |
| 19 | Supply and Fixing of DOL Starter for 7.5 HP pump setconforming to IS : 13947, IEC 60947-1 suitablefor operation in AC, three phase, 50 Hz(+ 5%) and 415 V (+ 10 %) including Ammeter , Voltmeter, Thermal overload relay, 16 amps 2 pole magnetic contactor with under voltage protection, indicating lamp, starting capacitor, running capacitor and On/Off push button switches, 5 way connector, wiring with 1 sqmm copper PVC insulated cable, powder coated vermin proof box including tghe capacitor as per IE rules etc, complete and testing the pump set etc complete all as specified and directed. |
| 20 | Supply and Fixing of DOL Starter for 2.0 HP pump setconforming to IS : 13947, IEC 60947-1 suitablefor operation in AC, three phase, 50 Hz(+ 5%) and 415 V (+ 10 %) including Ammeter , Voltmeter, Thermal overload relay, 16 amps 2 pole magnetic contactor with under voltage protection, indicating lamp, starting capacitor, running capacitor and On/Off push button switches, 5 way connector, wiring with 1 sqmm copper PVC insulated cable, powder coated vermin proof box including tghe capacitor as per IE rules etc, complete and testing the pump set etc complete all as specified and directed. |
| 21 | Supply and fixing of Butterfly valves. valves of size 100 mm as per API 609, BS 5155 shall be wafer type for mounting between specified flanges and shall be rated for 1034 kPa shutoff and nonshock working pressure, bodies shall be cast ferrous metal conforming to ASTM A126 CL B/ IS 210 Gr FG 200 for body wall thickness and disc shall be of S.G. Iron, accessories shall be matching flanges, gasket, hardware etc. Butterfly valves shall confirm to API 609.complete all as specified and directed. |
| 22 | Supply fixing testing and commissioning submersible cable flat 16 sqmm x 3 core PVC insulated and PVC sheathed with multi stranded copper conductor 1100 volts grade fixed to submersible motor column pipe using suitable size of clamps made out of stainless steel flat of size 20x2 mm with steel nuts bolts & washer forevery column pipe of 3 mtr lengh completeall as specified and directed |
| 23 | Supply fixing testing and commissioning submersible cable flat 6 sqmm x 3 core PVC insulated and PVC sheathed with multi stranded copper conductor 1100 volts grade fixed to submersible motor column pipe using suitable size of clamps made out of stainless steel flat of size 20x2 mm with steel nuts bolts & washer for every column pipe of 3 mtr lengh all as specified and directed. |
| 24 | Supply and laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of size 35 sqmm x 3.5 core laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles etc, complete all as specified and as directed. |
| 25 | Ditto but sec. area 16 sqmm x 4 core |
| 26 | Excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth for laying of electric cables or water pipe etc, not exc 10 sqmm on plan and not exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge. |
| 27 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil completeall as specified and directed |
| 28 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting pointcompleteall as specified and directed |
| 29 | Material and labour for river washed and screened, dry sand for cushioning of cable in trenches for cable protection including spreading, leveling and hand punning complete all as specified in SSR Part-I and as directed. Note :-Only compacted thickness of sand will be measured and paid separately. |
| 30 | S & F machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 100 mm thickness M-50 Grade not less than 0.45 mtr wide for repairing road cut/footpath carried out under respective items completeall as specified and directed |
| 31 | Supply, laying un-reinforced precast concrete cable cover class LV type 1flat size 250mm x 150 mmx 40 mm completeall as specified and directed |
| 32 | M&L PCC 1:2:4, type B1 (using 20 mm graded granite stone aggregate) as in coping for steel pole including necessary formwork completeall as specified and directed |
| 33 | M&L for PCC 1:2:4 type B2 (using 40 mm graded stone aggregate) for road/Hard standing cutting complete all as specified and as directed. |
| 34 | M & L in replacement Earth continunity conductor or main earthing leadfixed to submersible motor/pump to Control panel using suitable size of insulator clamps with suitable size tie or nuts bolts & washer for every column pipe of 3 mtr lengh or any other indicated situation for loop earthing etc. as required of 4.00 mm dia GI or steel wire all as specified and directed. |
| 35 | Supply & fixing for 6 kg capacity ABC (Powder type) Fire Extinguisher in HP Miled Steel Cylinders ISI marked / approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully chaged with ABC powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension braket and conforming to IS:15683 complete all as specified and directed. |
| 36 | Supply & fixing for 9 kg capacity ABC (Powder type) Fire Extinguisher in HP Miled Steel Cylinders ISI marked / approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully chaged with ABC powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension braket and conforming to IS:15683 complete all as speciifed and directed. |
| 37 | Material and labour for fire points made out from MS angle iron 40 x 40 x 6 cutting welding etc,including rain protection canopy made out of 2.0mm thick CRCA Sheet , painting with two coats of red postoffice colourall as directed for keeping various accessories complete all as specified and directed. |
| 38 | M&L for earthing with GI earth plate electrode of size 60cm x 60cm x 6 mm thick burried directly in ground with charcoal and salt in alternative layers (earth pit not less than 2.25 mtr deep below the ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to GI earth lead wire of 4 mm diaby means of bolts, nuts, check buts and washers of galvanised iron or steel all as shown in electrical plate no-05 of SSR connected to earthing test point all as specified but PCC pit should be 20 to 30 cm away from the excavated earth.PCC 1:3:6 type C-1 for pit, watering pipe GI 20 mm dia, GI mesh for funnel, RCC cover with a lifting handle of size 420 x 420 x 80 mm for earth pit, including tesing complete all as specified and directed by Engr-in-Charge. |
| 39 | Earth continuity conductor or main earthing lead to wall/ buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc.as required of 32 x 6 mm galvanised iron strip complete all as specified and directed. |
| 40 | M&L for Lifting/taking out defective submersible pump of any capacity alongwith column pipe of any size and submersible cable, dismantling the pump from motor, setting aside for repair /servicing / overhauling including lowering the pump set into borewell replacement of packing and nut bolts (if required) and testing after the completion of works in the presence of JE/ Engr in charge . |