| 1 | Material & Labour for complete removal of existing treatment internal as well as external or ceiling and soffits of Over Head Tank and installation of GE utility by scrapping with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7\"/9\" to make the surface free from dust, loose paint etc. by skilled labour complete all as specified and directed. |
| 2 | Material & Labour for applying one coat of white cement based putty on old as well as new plastered surface of Over head tank and installation of GE utility including sand papering the puttied surfaces to form an even and smooth surface complete all as specified and directed. |
| 3 | Material & Labour for preparation of puttied surfaces and applying two coats of weather proof exterior emulsion paint over and including priming coat of exterior primer over new or untreated old plastered/ unplastered surfaces of Over head tank and installation of GE utility to be applied with fully automatic airless spray machine with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI, by allowing 6-8 hrs to dry the surface for painting of subsequent coats complete all as specified and directed. |
| 4 | Material & Labour for applying two coats of oil bound distemper over a coat of alkali resistant primer over new or untreated old plastered surface using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper/ primer should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed. |
| 5 | Material & Labour for applying one coat of weather proof exterior emulsion paint over and including priming coat of exterior primer over new rough plastered surfaces to be applied with fully automatic airless spray machine with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI, by allowing 6-8 hrs to dry the surface for painting of subsequent coats complete all as specified and directed. |
| 6 | Material & Labour for applying two coats of weather proof exterior emulsion paint over and including priming coat of exterior primer over old existing rough plastered surfaces to be applied with fully automatic airless spray machine with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI, by allowing 6-8 hrs to dry the surface for painting of subsequent coats complete all as specified and directed. |
| 7 | Note for Periodical services:-MOBILISATION OF T&P AND MATERIAL: The Contractor shall complete the following activities within 20 days from the date of commencement of work:(a) Submission of Memorandum of Understanding (MOU) with any of paint manufacturer(b) Obtaining approval of paints & authorized applicator of paints manufacturer from GE(c) Procurement of T&P required for mechanical mode of painting(d) 30% of the quantity of Paints, Primer & Putty required (as per respective manufacturer’s average coverage area) for various items of painting catered in CACOMPENSATION FOR DELAY IN MOBILISATIONOF T&P AND MATERIAL BEYOND 30 DAYS: In case of failure on the part of contractor to complete above mobilization within the stipulated period, compensation shall be recovered from the contractor at the rate of Rs. 1,000/- (Rupees one thousand only) per day subject to a maximum of Rs. 1,00,000/- (Rupees one lakh only). Condition 50 of IAFW-2249 (General Conditions of Contracts) shall be deemed amended accordingly. The contractor shall submit original Tax invoices & e-way bills for the entire quantity of materials so procured. The material and T&P collected shall be entered in the MB as “NOT TO BE ABSTRACTED” and shall be duly signed by both the parties. |
| 8 | Material & Labour for 18-20 mm thick black granite stone slab of any type with table rubbed and polished , set in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of granite slab complete all as specified and directed. |
| 9 | Demolition of Unreinforced Cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed |
| 10 | Hardcore of gauge n exc 63mm, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 11 | Material & Labour 75 mm thick PCC 1:4:8 Type D–2 using 40mm graded crushed stone aggregate as in sub base of floor/ hard standing etc and finished even and fair without using extra cement complete all as specified and directed. |
| 12 | Material & Labour for 60mm thick (M-35 grade concrete) machine pressed precast concrete interlocking paver block of approved design and shape confirming to IS 15658-2006 with a cushioning strength not less than 250 kg/sqmmwith grey cement and pigmentlaid over 25mm thick sand cushning complete all as specified and directed. Note :- Sand cushioning will be measured and paid seperately. |
| 13 | Material & Labour for sand cushioning layer of 25mm thick under interlocking tiles complete all as specified and directed. |
| 14 | Material & Labour for Providing cement concrete in edges Type B1 1:2:4using 20 mm Graded Aggregate in roof kerbs or mud stops rounded or chamfered on edges complete all as specified and directed. |
| 15 | Taking down cement plaster and raking out joints, hacking for key, scrubbing down with water built in cement mortar complete all as specified and directed. |
| 16 | Material & Labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortor 1:4 finished even and fair without using extra cement complete all as specified and directed.Note:- Plaster shall be done using yamuna sand/ black sand. |
| 17 | Material & Labour for 10 mm thick rendering on other than fair faces of brick or concrete surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed.Note:- Plaster shall be done using yamuna sand/ black sand. |
| 18 | Material & Labour for rough cast plaster with and including 15 mm thick rendering in cement mortor 1:3 on brick wall or concrete surfaces as specified in clause 14.22 of SSR Part -I complete all as specified and directed. |
| 19 | Demolition or dismantling ofloose brick work built in cement mortar of any description etc complete all as specified and directed. |
| 20 | Material and labour for brick work in small patches over boundary wall with sub class `B` brick old size in CM 1:4 straight or curved on plan exc 6m mean radious complete all as specified and directed. |
| 21 | Material and labour using old brick work retrived from Ser item No 18.00 with sub class `B` brick old size in CM 1:4 straight or curved on plan exc 6m mean radious complete all as specified and directed. |
| 22 | Supply & Fix in repair Hacking out old broken glass (any thicknesss, size,quality or description) and supply & fix 3mm thick Sheet glass, ordinary quality and glazing with oil putty in square not exc 0.5 sq.m in each pane complete all as specified and directed. |
| 23 | Supply and fixing of mild steel framed workas in ornamental gates or other section with gusset plates,rails, braces, grills, pintaletc. complete drilled for fixing steel sheeting or other covering to be prepare for hanging including either hooks or hinges etc. and half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts and for shed rolled angle section use as a truss and for cattel trap including cutting tops to shape as directed, drilling holes, notching for wire, etcconforming to Fe-290 (Gde E-165), and incl dismantling of old unsv gates /door complete all as specified and directed. |
| 24 | Material & Labour for providing PCC 1:2:4 type b1 (20mm graded stone aggregate) as in coping benching and bed block etc including necessary form work complete all as specified and directed. |
| 25 | Supply and fixing for prepainted galvalume aluminum zinc coating GI based fully corrugated profile tile pattern steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, ridge, vally gutter etc fixed with self tapping screws or using J hook where as required complete all as specified and directed. |
| 26 | Supply and fixing for prepainted galvalume aluminum zinc coating GI based corrugatedsteel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, ridge, valley gutter etc fixed with self tapping screws or using J hook where as required complete all as specified and directed. |
| 27 | Supply and fixing for prepainted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, ridge, valley gutter etc fixed with self tapping screws complete all as specified and directed. |
| 28 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 29 | Material & Labour for re-securing/ adjusting existing false ceiling grid, any type and make are required tightening to remove sag portion/ depression in false ceiling grid including replacement of missing sections / part/ suspenders as per existing size etc complete all as specified and directed. |
| 30 | Dismantling of wall lining, ceiling board or insulation boards, any thickness, including cover fillets complete all as specified and directed. |
| 31 | Providing & fixing false ceiling at any heights with GRG (Glass Fibre With Reinforced Gypsum) false ceiling tiles of perforated Size 595 x 595 mm of approved texture, 12mm Semi With perforatedthick micro tegular design and patterns having moisture content less than 2%, humidity resistance edged GRG thick square edged of 99%, NRC0.50 to 0.75 as per IS false ceiling GRG false ceiling 8225:1987, Noncombustible as per BS tiles 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of mainT runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1 OOOmm length and L shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 tiles fully mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in Charge complete all as specified and directed.Make of GRG Ceiling Board : Diamond / Armstrong / BSR Calsi |
| 32 | Material & Labour for Metal false ceiling consisting of 600mmX600mm, 5mm(+ 0.25) thick embossed false ceiling sheet of density 600 Kg/Cbm manufactured by an ISO-9001-2015 certified company, used as panel insert in a frame work made using anodised aluminium T-section of sizes 1\" x1\" (25mmX25mm,1mm thick) in square pattern of grid sizes of 2\"X2\"(600mmX600mm). The aluminium framework is supported from the ceiling with the help of \"J\" hook and G.I. wire / 4mm MS rods at every 1meter interval of required sizes to maintain proper level etc. The aluminium frame work is supported on the side wall with the use of aliminium L- Section of size 1\"X1\" (25mmX25mm, 1mm thick) angles etc complete as per direction of Engineer-In- Charge, Manufacturer, specification and drawing. |
| 33 | Supply & Fix of 5-8 mm thick colour PVC panel, hollow profile PVC wall paneling/ lininginclusive of fixing arrangement including screws, side beading, angle, U- channelfixing on wall complete all as specified and directed. |
| 34 | Supply & Fix 5 mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on wall to make PVC Frame as per specification and drawing complete all as specified and directed. |
| 35 | Supply & Fix of Mild steel work as in posts & struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or reveting, etc., & similar work conforming to Fe 290 or E-165 including dismantling of existing pole complete all as specified and directed.Note :- Work Executed over existing boundary wall necessary fastners if required including in quoted rate. |
| 36 | Supply & Fix concertina coil 600 mm dia (approx 50 turns per coil) in stretch position hot dip galvanised steel wire coated with CLR anti corrosive paint making diamond shape with the help of dove tail clip 18 SWG fixed over barbed wire barbed wire with angle iron, the concertina coil is to be fixed with the barbed wire at point wherever coil touch the bottom of barbed wire with the help of hog rings 14SWG complete all as specified and directed.Note:- Hoggong shall be fixed at a interval of 600mm C/C wherever it touched with barbed wire shall be 300mm it shall be deemed to included in quoted rate. |
| 37 | Supply & Fix galvanised 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. and taking down of existing complete all as specified and directed. |
| 38 | Material & Labour 18-20 mm thick Machinie cut Kota stone slab in flooringon treads, landing laid over including 20mm thickscreed bed 1:4 jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and directed. |
| 39 | Material & Labour for two coats ofwhite wash on the walls , pillars, cornices of old decorated brick/concrete, plastered or unplastered surfaces of walls, etccomplete all as specified and directed. |
| 40 | Material & Labour for dressing of ground by cutting / removing vegetation, scrapping, clearing of all grass, shrubs, bushes, weeds, trees and saplings not exceeding 30cm in girth (measured at a height of 1m above the ground level) on either side of building or low laying area, aprons and other places in alpha power house area by deploying jungle jims (06 feet) with tractors, and level the ground as per natural ground slope operators including fuel, lubricant, etc. complete all as specified and as directed.Note:- Work executed at Alpha Power house |
| 41 | Cleaning removing all scale and dirt, boulders, grass, vegetation of any size etc, from drain and from mouths of circulating pipes, etcincl removing of the same upto 50m and spreading or level with the exesiting ground complete all as specified and directed.Note:- Work executed at Alpha Power house |
| 42 | Material & Labour for removing existing 60/80 mm thick coloured precast concrete interlocking paver block of any shape including demolition of PCC and relaying of the same with cement concrete 1:2:4 type B1 using 20mm graded mechanically crushed stone aggregate 75mm thick and rubber moulded M-35 grade paver block retrived from dismantling with grey cement and pigment to match, over and including 25 mm thick sand cushion complete all as specified and directed. |
| 43 | Uprooting scrubs/plant/flora & fauna on wall girth not exceeding 100mm from brick wall by cutting holes into masonry/walls for digging out roots and dosing Sulfuric/Phenolic Acid as per manufacturer\"s instruction to burn deep rooted tree roots and making good the disturbed area with cement mortar in CM 1:3 using water proofing compound including necessary scaffolding upto a height of 20 metre complete all as specified and directed.Note :-(i) scaffoldingincl quoted rate. (ii) Brickworkand plaster shall be paid separetely.(iii) Removal of any type of tree on walls and on roof including peepal tree is inclusive in quoted rate.(iv) Work executed at refrigeration building. |
| 44 | Note:-Amount of credit ofRs. 96200.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in pdf form which will be deducted offline while acceptance of tender. |