| 1 | Excavation in trenches, n.exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc and getting out in any type of soil complete all as specified and directed. |
| 2 | Excavation in trenches, n.exc 1.5 m wide and depth exc 1.5 m but n exc 3.0 m ; for foundation and getting out in any type of soil complete all as specified and directed. |
| 3 | M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) in foundation filling and mass concrete complete all as specified and directed. |
| 4 | M&L PCC 1:2:4 type B2 (using 40mm graded agg) as in foundation filling and mass concrete etc complete all as spd and directed. |
| 5 | Returning filling in incl spreading, levelling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed. |
| 6 | Removing excavated material (soil) n.exc 50 m and depositing where directed at a level n. exc. 1.50 mtr above the starting point complete all as specified and directed. |
| 7 | M&L for treating the bottom and sides of excavation @5 ltrs of emulsion per sqm of the surface area complete all as specified and directed. |
| 8 | M&L for treating the backfill in contact with foundation @7.5 ltrs of emulsion per sqm of the vertical surface complete all as specified and directed. |
| 9 | M&L for treating the top surface of filled earth @5 ltrs of emulsion per sqm of the surface area complete all as specified and directed. |
| 10 | M&L for treating the soil under plinth protection @ 5 ltrs of emulsion per sqm of the surface area complete all as specified and directed. |
| 11 | M&L for brick work with fly ash bricks (old size), straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:6 complete all as specified. |
| 12 | M&L for brick work with fly ash bricks (old size), straight or curved on plan any radius in half brick thick wall with old size bricks built in cement mortar 1:4 complete all as specified. |
| 13 | S&F of TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 14 | S&F of TMT bars but 5mm and over upto 10mm dia as in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 15 | Use and waste of formwork to sides of concrete fair finished surfaces of foundations footings bases of columns raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work verticle or batter complete all as specified and directed. |
| 16 | Use and waste of formwork to sides and soffits of beam of any description, concrete surface fair finished complete all as specified and directed. |
| 17 | Use and waste of formwork to chajjas, concrete fair finished surfaces complete all as specified and directed. |
| 18 | Use and waste of formwork to sides of pillars, struts columns etc concrete fair finished surfaces complete all as specified and directed. |
| 19 | Use and waste of formwork to soffits of concrete fair finished surfaces of suspended slabs such as roof slab,floor slabs landings and similar works not exc 200 mm thick complete all as specified and directed. |
| 20 | Formwork to edges of concrete flats, treads, breaks in floors,window cills, concrete railings,openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm complete all as specified and directed. |
| 21 | M&L for reinforced cement concrete M-25 design mix (using 20mm graded aggregates) in fdn inclfootings, foundation beams, plinth beams, base for columns etc basement slabs and mass concrete complete all as specified and directed. |
| 22 | M&L for reinforced cement concrete M-25 design mix(using 20mm graded aggregates) in Beams,cantilevers, lintel over 1.5m span etc complete all as specified and directed. |
| 23 | M&L for reinforced cement concrete M-25 design mix(using 20mm graded aggregates) in chajjas etc complete all as specified and directed. |
| 24 | M&L for reinforced cement concrete M-25 design mix (using 20mm graded aggregates) in columns etc complete all as specified and directed. |
| 25 | M&L for reinforced cement concrete M-25 design mix(using 20mm graded aggregates) in slabs supported on walls beams, columns etc and plastering in cement mortar 1 :3 mixed with Polymer water proofing compound when concrete is still green complete all as specified and directed. (Plastering and water proofing compound shall be measured and paid separately under respective item) |
| 26 | M&L for rendering 15mm thick in cement mortar 1:4 using liquid water proofing compound (1% by weight of cement content) on brick work or concrete surfaces of wall, surfaces finished even and smooth using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately under respective item) |
| 27 | M&L for rendering 10 mm thick in cement and sand mortar 1:6 on other than fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth without using extra cement complete all as specified and directed. |
| 28 | M&L for rendering 10 mm thick in cement mortar 1:3using liquid water proofing compound (1% by weight of cement content) on roof slab when concrete is still greenincluding finishing the surface even and smooth without using extra cement complete all as specified and directed. |
| 29 | M&L for rendering 5 mm thick in cement mortar 1:3 on concrete surfaces of ceiling/Top and sides of chajjas/facia of roof projection incl necessary formwork including finishing the surface even and smooth without using extra cement complete all as specified and directed. |
| 30 | Supply only polymer liquid water proofing compound. |
| 31 | Preparation of newly plastered surface of walls and applying three coats of white wash complete all as specified and directed. |
| 32 | Preparation of newly plastered surface of ceiling and applying three coats of white wash complete all as specified and directed. |
| 33 | Preparation of newly plastered surface of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified. |
| 34 | Preparation of newly plastered surface of walls and applying two coats of Acrylic Emulsion over a coat of alkali resistant primer complete all as specified. |
| 35 | S&F of pressed steel frames of size 125 x 60 mm for doors with one or more rebates incl necessary fixing lugs,hinges, lock strike plate, incl filling of PCC 1:3:6 type C-1 using 12.5mm graded stone aggregate as in frames/hold fast blocks complete all as specified and directed. |
| 36 | S&F of 35 mm thick Factory made Plain framed, panelled shutter (two panel) made up of 2nd class hardwood with lock rail and panel of 9 mm commercial ply with commercial veneering on both faces. The size of rail and stile as per specification, kiln seasoned and chemically pressure treated.; sizes of members as specified supplied and fitted to chowkats complete all as specified and directed. |
| 37 | S&F of factory made solid panel PVC door shutter 30mm thick(style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panel will be of wire gauze in lieu of PVC sheet panel. The wire gauze shall be wrappd on an additional square 8mm MS solid tube and this tube shall be welded to MS tubes. The wire gauge shall be stretched to tighten firmly Complete all as per drawing and all as specified and directed by Engineer-In-Charge. |
| 38 | S&F of box type Steel windows/ventilators comprised oftubular frame and shutters made out of 1.25mm thick M S sheet tube factory made with double side shutters wire gauzed shutter & glass glazed shutter (wire cloth and glass panes shall be measured and paid separately)with side hung shutters with steel handle and steel peg stay dovetailed or welded incl 2 Nos. tower bolts 150mm long for each leaf and 10mm square bar grills at spacing 150 mm c/c fixed in frame work, including other fittings; hinges, handles, tarred hold fasts, PCC blocks etc complete all as specified and directed. |
| 39 | S&F of galvanized mild steel wire-cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples complete all as specified. |
| 40 | S&F of 03 mm thick sheet glass, ordinary quality and glazing with oil putty/wooden beads in square not exceeding 0.5 square metre in each pane complete all as specified. |
| 41 | Preparation of new wooden surfaces of any description not otherwise described over 10 cm in width or girth including preparation of surfaces and two coat of synthetic enamel paint over one coat of pink primer complete all as specified and directed. |
| 42 | Preparation of new steel surfaces of any description over 10 cm width or girth and priming with redoxide zinc chrome and painting with two coats of synthetic enamel paint complete all as specified and directed. |
| 43 | S&F of mild steel sliding door bolts 300mm long, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified and directed by Engineer-In-Charge. |
| 44 | S&F of mild steel barrel tower bolts 200mm long, stove enamelled black, with bright bolt and fixed, complete all as specified and directed by Engineer-In-Charge. |
| 45 | S&F of mild steel pressed handles of size 150mm, oval type, stove enamelled black, complete all as specified and directed by Engineer-In-Charge. |
| 46 | S&F of butt hinges 100mm size, medium weight, cold rolled mild steel, and fixed, complete all as specified and directed by Engineer-In-Charge. |
| 47 | S&F of20 mm dia curtain rod of mild steel with decorative finish , with fixing brackets complete all as specified and as directed (two brackets per opening of door and window and 08 Nos PVC rings). Complete all as specified and directed by Engineer-In-Charge. |
| 48 | M&L for plain cement concrete Type B-1, 1:2:4 (20 mm graded crushed stone aggregate) as in copings, benching, haunching, bond stones bed and the like including use of necessary form work complete all as specified and directed. |
| 49 | M&L for 75mm thick PCC 1:4:8, type D-2 as in sub base forpavement, floor etc complete all as specified and directed. |
| 50 | M&L for Machine cut kota stone slab flooring 16-18 mm thick,area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 15 mm thick screed bed in cement and sand mortar 1:4, complete all as specified. |
| 51 | M&L for Machine cut kota stone slab flooring 16-18 mm thick over and incl 10 mm thick rendering in cement and sand mortar 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab as in riser of steps/ pillars/ skirting/ dado including rubbing and polishing complete all as specified and directed. |
| 52 | M&L for 75mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in plinth protection and similar works including finishing the surface of concrete topping even & fair, without using extra cement complete all as specified. |
| 53 | S&F of PVC (SWR) pipes single socketed in any length with rubber ring joints fixed in trenches/floors/walls for 110 mm bore of pipe fixed in repair complete all as specified and directed. |
| 54 | S&F of PVC (SWR) floor bend, plain including jointing with solvent cement 110 mm bore in repairs, complete all as specified and directed. |
| 55 | M&L for APP modified roof treatment over non-accessible RCC roof slab/chajjah/canopy/ parapet wall to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and directed :-(a) Cleaning existing surface properly. (b) Applying oil bound bitumen primer @ 0.30 litre/Sqm manufacture by the same agency as that of APP with a density of 0.87-0.89 Kg per litre at 25 degree centigrade on prepared surface.(c) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.0 Kg/Sqm reinforced with non-woven polyster fiber of weight not less than 160 gsm/sqm using butane torch by torch application with 10 cm side laps and 15 cm end lap, complete all as specified and directed. |
| 56 | M&L for PCC padding 1:2:4, type B-1(using 20 mm graded crushed stone aggregate) of average thickness 50 mm to be provided in slope fixed with chicken wire mesh, complete all as specified and directed. |
| 57 | M&L for spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green in squares of 300 x 300 mm, complete all as specified and directed. |
| 58 | Dismantling of asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings including ridges, complete all as specified and directed. |
| 59 | Dismantling framed trusses of span not exceeding 10m, complete all as specified and directed. |
| 60 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 61 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thicknness, including cover fillets, complete all as specified and directed. |
| 62 | S&F of pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 63 | S&F of pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 64 | Erection and fixing only steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240. Complete all as specified and directed. |
| 65 | Erection and fixing only steel tubular work as in purlins including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240. Complete all as specified and directed. |
| 66 | S&F rolled mild steel Fe 10-W (Gde-E-250) qualiy-A in Joist, channel, angle,tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as specified and directed. |
| 67 | M&L for preparation of old steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint, complete all as specified and directed. |
| 68 | Demolition of brickwork/ stone masonrybuilt in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 69 | M&L for bric kwork with sub class ‘B’ (old size) bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:4 complete all as specified and directed. |
| 70 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc. Complete all as specified and directed by Engineer-In-Charge. |
| 71 | M&L rough cast finish plaster with a mixture consisting of crushed stone or fine gravel aggregate mixed with coarse sand and cement in the ratio of 1:1:1 over & including 12mm thick rendering in cement mortar 1:3 on fair faces of brick masonry or concrete surfaces of walls complete all as specified and directed .. |
| 72 | M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar 1:6 on walls finished even and fair, complete all as specified and directed by Engineer-In-Charge. |
| 73 | M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar 1:4 on walls finished even and fair, complete all as specified and directed by Engineer-In-Charge. |
| 74 | Preparation of newly plastered surface of walls and applying two coats of Oil Bound Distemper over a coat of primer complete all as specified. |
| 75 | Complete removal of existing treatment of any description on walls, complete all as specified and directed. |
| 76 | Applying one coat of wall care putty not more than 2mm thick complete all as specified and directed. |
| 77 | Preparation of existing surfaces incl washing, rubbing down and stopping of distempered and painted surface of walls and applying two coats of Oil Bound Distemper complete all as specified and directed. |
| 78 | Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed. |
| 79 | M&Lfor providing reinforced cement concrete cast in situ Type B-1, 1:2:4 ( 20 mm graded stone aggregate) as in lintels upto 1.5m clear span including necessary formwork complete all as specified and directed by engr in charge.(Note : Reinforcement shall be measured and paid separately) |
| 80 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off premises complete all as specified. |
| 81 | 25 mm thick PCC 1:2:4 type B-1, using 20 mm graded stone aggregate, including finishing surface of concrete topping even and rough complete all as specified. |
| 82 | M & L for Non - skid Ceramic joint free tiles 7 to 8 mm thick coloured/wooden finish (square/ rectangular)area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 15 mm thick screed bed in cement and sand mortar 1:4, complete all as specified. |
| 83 | Glazed coloured ceramic tile 450 x 300 x 7mm thick (coloured) on vertical surfaces such as skirting, dados etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10 mm thick plaster in cement and sand mortar 1:4 complete all as specified. |
| 84 | 18mm thick Zed Black Granite machine cut in any position bull nosed on front face, laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing over and including 20 mm thick screed bed in cement and sand mortar 1:4 complete all as specified and directed. |
| 85 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 86 | Material and labour for Reinforced cement concrete 1:2:4 typeB-1 (using 20 mm graded stone aggregates) as in slab ofseptic tank, soak well, etc supported on walls, beams & columns in floors, roofs, landings, balconies, canopies, deckslabs & in shelves &the like etccomplete all as specified and directed. |
| 87 | Taking down chowkhats or frameswith shutters (without taking off shutters from the frames) of area n. exc 1.5 Sqm each and removing from site complete all as specified and directed. |
| 88 | Taking down chowkhats or frameswith shutters (without taking off shutters from the frames) of area exceeding 1.5 sqm and not exceeding 4.00 sqm each and removing from site complete all as specified and directed. |
| 89 | M&L for ceiling using 9mm thick gypsum based ceiling tiles with wheather resistance face on back side and vinyl finish including framework on the front fixed in 24mm GI armstrong frame work of grid 600x600 mm size, the members of snap grid frame work of GI/Steel section of 24mm wide with T-flanges, channels etc of white colour having rotary stiching on all members, i.e main runner, 1200x600mm cross tee galvanised with minimum thickness of 120 gms per/sqm passed through 500 hrs test and hanging the same with existing roof members such as rafters, pulins or other wooden members particularly provided for hanging pupose using 8mm dia mild steel bar of required length fixed with nut bolt of 50mm long and 10mm dia of neck with washer flat iron 50x6mm thick clamps etc to steel members, complete all as specified and directed by Engineer-In-Charge. |
| 90 | S&F of 6mm thick PVC hollow wall paneling plain/coloured/printed fixed with screws to wall and corner, edges of panels be sealed with appropriate arrangement, colour and pattern as approvedComplete all as specified and as directed. |
| 91 | S&F of powder coated anodised aluminium frame (thickness of powder coating not less than 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. |
| 92 | S&F powder coated anodised aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified. |
| 93 | S&F powder coated anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.) hinge type B-21 100mm long (2 Nos) suitable handle (1 No.) complete all as specified and directed. |
| 94 | S&F powder coated anodised aluminium fly proof window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.) hinge type B-21 100mm long (2 Nos) suitable handle (1 No.) complete all as specified and directed. |
| 95 | S&F aluminium alloy wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified & directed. |
| 96 | S&F,aluminium (extruded section)door closer hydraulically regulated designationNo 3, universal type, suitable for door shutters of851 to 1000mm in width and of weight between 61 to 80 kg and fixed in repair complete all as specified and directed. |
| 97 | S & F floor door stopper 140mm of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor all as specified and directed. |
| 98 | S & F, 200 mm size, aluminium anodised , barrel tower bolts of extruded section & fixed completeall as specified and as directed. |
| 99 | S&F Mortice lock 100mm with two leavers (Vertical Surfaces), mild steel body and fixed complete all as specified and directed. |
| 100 | Excavating in post holes each n exc 0.5 cum, getting out, in soft /loose soil, ramming earth filling or borken rubble mixed with earth around in layers nexc 25 cm watering and removing ssurfaces soil to distance nexc 50 m and making good surfaces all as specified and directed. |
| 101 | Supply and fix 5 mm thick mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to Fe 290 grade E-165 complete all as specified. |
| 102 | Material and labour for 15 mm thick renderingin cement mortar 1:4 on fair faces of brick wall or concrete surfaces, finished the surfaces even and fair, etc complete all as specified. |
| 103 | Cutting chases, pinning in brick walls making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exceeding 10 cm but not exceeding 20 cm girth, complete all as specified and directed. |
| 104 | M&L for 100mm thick plain cement concrete 1:3:6 type C2 using 40 mm graded aggregate as in sub base for flooring allas specified and directed. |
| 105 | Surface excavation in any type of soil not exc. 30 cm and averaging 15 cm deep and getting out complete all as specified and directed. |
| 106 | M & Lfor Hardcore of Broken bricks gauge n exc. 63 mm, deposited, spread and levelled in layers n.exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 107 | M & Lfor Plain Cement concrete 1:2:4 (using 40mm graded stone aggregate)in sub base of floor and pavings complete all as specified and directed. |
| 108 | M&L forcement concrete 1:3:6, type C-2 as in in surface channel and drains complete all as specified and directed. |
| 109 | M & L for Sand filling under floors including watering and consolidation, complete all as specified and directed. |
| 110 | M & L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade, complete all as specified and directed. |
| 111 | M&L for precast cement concrete 1:2:4, type B-1 as in kerb stone, fair faces including chamfers, weatherings, throating ect and setting in CM 1 :4 including necessary formwork complete all as specified and directed. |
| 112 | Taking down carefully aluminium / copper point wiring (light, fan, socket, powerpoint) including batten, conduit and fittings such as switches, ceiling rose, sockets, brackets, light fittings, switch board etc, making good distrubed surfaces of wall, floar, ceiling etc complete all as specified and directed. |
| 113 | M&L for point wiring for one light / fan / bell point with 1.5 sqmm cable PVC unsheathed and insulated copper multistranded conductor ( FRLS ) 1100 Volts grade cable ( red colour cable to be used for live connection and black colour cable to be used for neutral connection ) controlled by one way switch drown through and including PVC concealed conduit with all accessories including 1.5 sqmm copper multistrand conductor (FRLS ) 1100 Volts grade unsheathed PVC insulated ( green colour ) continuity earth wire connected to common earth dolly and sunk cast pressed steel Metal flush mounting box for mounting of fittings like switch , socket and fan regulator and cover plat of suitable modules capacity and make of swich socket complete all as specified and as directed. |
| 114 | One light point controlled by one, one way switch |
| 115 | One fan point controlled by one, one way switch |
| 116 | One socket outlet 3 Pin, 5 Amp on independent board |
| 117 | One socket outlet 3 Pin, 5 Amp on same board. |
| 118 | - ditto - all as per item No 113 here in before but 2.5 Sqmm P.V.C insulated unsheathed cable with stranded copper conductor for 6 pin 6/16 Amp switch socket combination on independent board. |
| 119 | - ditto - all as per item No 113 here in before but 4 Sqmm P.V.C insulated unsheathed cable with stranded copper conductor for 6 pin 6/16 Amp switch socket combination on independent board. |
| 120 | S&F ofswitch piano flush type single pole one way 6 Amp (ISI Marked) |
| 121 | S&F of switch piano flush type single pole one way 15 Amp (ISI Marked) |
| 122 | S&F of socket out let 2 in 1, 3 pin 5 Ampflush type (ISI Marked) |
| 123 | S&F of socket out let 2 in 1, 3 pin 15 Amp flush type (ISI Marked ) |
| 124 | M&L for ceiling rose, surface Bakelite 65 x 17.50 mm of three terminals PVC/Polycarbonate,isolated body (ISI Marked) |
| 125 | Taking down old unserviceable regulator & supply & fix electronic type fan regulator stepped type on existing phenolic laminated sheet etc. suitable for ceiling fan. |
| 126 | S&F in repairPVC/Polycarbonate Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings type with back plate suitable for batten fittingscomplete all as specified and as directed. Make: Anchor/ Legrand/ Havells |
| 127 | Supply, installation, testing and commissioning of 20 watt 4 ft long LED Batten housing made of extruded alluminium with milky white diffuser and inbuilt electronic driver system lumen output should be at least 1800 lumen with a CCT of 6000 K, power factor should be greater than 0.9 with all accessories and connecting up complete with 3 core flexible cable white of size 23/0.0076 all as specified and directed. |
| 128 | Supply and fixing in repair LED Security light fitting 35 watt Pressure die cast aluminium housing, heat resistant toughened glass with frame IP 66 Protection complete fitting including1.5 mtr long 40/50 mm (Suitable size for fixing of LED light fitting) bore GI pipe mounting bracket/Clamp made to shape for fixing on pole/Wall with 40 mm x 6 mm flat iron clamp 02 numbers with 16 mm dia bolts, nuts and washersall as specified and directed by Engineer-in-Charge.. |
| 129 | Supply and fixing LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with highefficiency PMMA diffuser soft glare free light completewith driver & LED lamp suitable for roofceiling including connecting up with driver threecore flexible copper conductor cases of suitable sizecomplete. and connecting up complete with 3 core flexible cable white of size 23/0.0076 all as specified and directed by Engineer-in-charge. |
| 130 | Supply and fix exhaust fan, made of sturdy engineering plastic AC single Phase. 230V of size 300 mm sweep with, blades, and frame and louvers cutting of the holes in existing wall and making good the surfaces all as directed. |
| 131 | Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor all as specified and directed by Engineer-in-Charge. |
| 132 | S&F of TP&N Vertical DB 6 way with MCCB 63 Amp 4 Pole ,as Incomer with Bus Bars, MCB SP 6 to 32 Amp -12 Nos ,Neutral Links, Blanking Plates complete all as specified and directed by Engr-in charge. |
| 133 | Supply and fixing sheet metal enlosure single pole and neutral with two pin socket and earth plug complete with one MCB single pole 240 volts 20 amps complete all as specified and directed by EIC. |
| 134 | Supplying, laying, jointing and testing under ground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 vols grade cross sectional area 35 Sqmm 3.5 core laid in trences, in floor, in duct, through pipes or along the pole including taking down old one complete all as specified and directed by Engr-in-Charge. |
| 135 | M&L fo sand cushioning to under ground cable with a layer of sand 8 cm thick before laying of cable and 15 cm thick after laying of cable complete all as specified and directed. |
| 136 | M&L for brick protection using old size sub class ‘B’bricks, laid flat, dry adjacent to each otherlaid length wiseperpendicular to theaxis of cable complete all as specified and directed. |
| 137 | M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed. |
| 138 | Supply and fixLED Bulk head fitting 10 watthighly cost effective compact, ultra low energy, modern design utility bulkhead suitable for indoor and outdoor applications with IP 65 protectionwatt complete with all accessories and connecting up complete with 3 core flexible cable white of size 23/0.0076 all as specified and directed by Engineer-in-Charge. |
| 139 | S & F sheet metal enclosure for MCB DB double door single pole & Neutral 8 way with 200 Amps rated bus bar all as specified and directed by Engineer-in-Charge. |
| 140 | Supply and fixingSP 6 To 32 AMP amp rating 240V, 10KA \"C\" curve miniature circuit breaker(MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 141 | - ditto - all as per above item no. 136 but SPN 32 AMP complete all as specified and directed. |
| 142 | Supplying, laying, jointing and testing under ground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 vols grade cross sectional area 25 Sqmm 2 core laid in trences, in floor, in duct, through pipes or along the pole including taking down old one complete all as specified and directed by Engr-in-Charge. |
| 143 | M&L for GI Pipe \"light grade\" galvanized with all fitting laid in trenches/on pole/road crossing of size 40mm |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail