| 1 | Taking down carefully Aluminum point wiring (light, fan socket or power) complete incl. (fitting such as switches, ceiling roses, pendants, regulators, sockets, boards, DB, MCB, light fittings etc), removing materials from site and making good disturbed surfaces of walls, floors etc, complete all as specified and directed |
| 2 | Material and labour for point wiring for one light / Fan / Ex Fan pointcontrolled by 1 one way switch with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable 1100 Volts grade in and including PVC capping and casing (double lock, ISI Marked) of suitable size with all necessary fittings along with 1.5 sqmm continuous PVC insulated unsheathed stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and to be terminated in and including MS rectangular Box with bakelite sheet cover / PVC rectangular switch board of suitable size for mounting switches, sockets, fan regulators etc or MS modular boxes / PVC modular box suitable for mounting modular switches, sockets etc including testing on completion complete all as specified and directed. |
| 3 | All as per item No 2 here-in before but for one 3 pin, 5 Amp socket point on the same board with other switch, complete all as specified and directed. |
| 4 | All as per Item No 2 here-in-before but for one switch socket outlet, 5 Amp on independent board all as specified and as directed. |
| 5 | All as per item No 2 here-in before but for one 3/5 pin, 15 Amp switch socket combination on independent board with 2.5 sqmm PVC insulated unsheathedmultistranded FRLS copper conductor, complete all as specified and directed |
| 6 | Material and labour forsub main wiring with 2 run of single core 6.0 Sqmm FRLS (ISI Marked) PVC insulated unsheathed multistranded copper conductor cable drawn through and including PVC Conduit / casing capping of suitable size along with accessories etc including one run of 6.0 Sqmm FRLS (ISI Marked) PVC insulated unsheathed multistranded copper conductor as earth wire, including taking down old wiring, complete all as specified and directed. Note :- Two run of 6.0 Sqmm single core cable, one run of 6.0 Sqmm earth wireand one run of PVC conduit/ casing capping shall be measured as one run length. |
| 7 | Supply and fix Switch piano flush button single pole, one way 6 Amp, complete all as specified and directed. |
| 8 | Fixing onlySwitch piano flush button single pole obtained from Item No 1, one way 6 Amp, complete all as specified and directed |
| 9 | Supply and fix in repair modular switch 1 way 6 Amps 1 Module complete all as specified and directed |
| 10 | Supply and fix in repairmodular switch 1 way 16 Amps 1 Module complete all as specified and directed |
| 11 | Supply and fix in repair socket outlet 5 pin, 6 Ampscomplete all as specified and directed |
| 12 | Supply and fix in repair Switch Socket combination 2 in 1, 6A flush type5 pin, 230 volts complete all as specified and directed |
| 13 | Supply and fix in repair Switch socket combination 2 in 1,3 pin, 5 amps and 15 amps flush type universal shuttered, complete all as specified and directed |
| 14 | Supply & fix in repair modular socket2 in 1,5 pin 6 Amps, 2 modules complete all as specified and directed |
| 15 | Supply & fix in repair modular socket2 in 1,3 pin 6Amp/16 Amps, 2 modules complete all as specified and directed |
| 16 | Supply and fix in repair Ceiling rose, 2 pole / 3 pole, PVC/polycarbonate, insulated body (ISI Marked) complete all as specified and directed |
| 17 | Fixing only serviceable Ceiling rose, 2 pole / 3 pole, PVC / polycarbonate, insulated bodycomplete all as specified and directed |
| 18 | Supply and fix in repair lamp holder PVC / Polycarbonate type with back plate suitable for batten fittings (ISI Marked) complete all as specified and directed |
| 19 | Supply and fix in repair Stepped type electronic fan regulator, AC 50 HZ, 230V,100 Watts, minimum 4 steps(ISI Marked), complete all as specified and directed |
| 20 | Supply and fix in repair Modular Fan regulator,100 watts 2 modules complete all as specified and directed |
| 21 | Supply and fix white modular cover plate with frame 1 Module complete all as specified and directed |
| 22 | Supply and fix white modular cover plate with frame 3 Module complete all as specified and directed |
| 23 | Supply and fix white modular cover plate with frame 6 Module complete all as specified and directed |
| 24 | Supply and fix white modular cover plate with frame 8 Module complete all as specified and directed |
| 25 | Supply and fix in repair LED tube light fittings mirror type with high out put diffuser 1 x10 Watt,220 V AC two feets long decorative type with polycarbonate housing & intigrated electronic driver and necessary electric connection complete all as specified and as directed. (Make: Havells/Bajab/Philips/Crompton |
| 26 | Supply and fix in repair LED tube light fittings 1 x 20 Watt four feets long with polycarbonate housing & intigrated electronic driver and necessary electric connection complete all as specified and as directed.( Make: Havells/Bajaj/Philips/Crompton) |
| 27 | fixing only serviceable LED tube light fittings 1 x 20 Watt four feets long with polycarbonate housing & intigrated electronic driver and necessary electric connectioncomplete all as specified and as directed. |
| 28 | Supply and fix in repair wallmountedbulk headLED light fitting 10 W, made up of poly carbonate housing with diffuser & intigrated electronic driver and necessary electric connection complet all as per specified and directed |
| 29 | Supply and fix in repair indoor commercial LED Luminaires 2ftX2ft 36 watt ultra modern recess mounting luminaire with high performance LEDs suitable for mounting with grid ceilingand including connecting up with twin core twisted flexible copper conductor cable includingtaking down old light fittings complete all as specified and directed. |
| 30 | Supply and fixing in repair switch socket combination5 Pin 6 Amp with PVC Box complete all as specified and directed. |
| 31 | Supply and fix in repair white modular cover plate with frame 3 Module complete all as specified and directed |
| 32 | Supply and fix in repair white modular cover plate with frame 8 Module complete all as specified and directed |
| 33 | Supply and fix in repair Switch piano flush button single pole, one way 5 Amp,complete all as specified and directed |
| 34 | Supply and fix in repair modular switch 1 way 6 A, 1 Module complete all as specified and directed |
| 35 | Disconnecting electrical wire of ceiling fan of any type / size and make, taking down from its position, dismantling blades, cleaning and greasing after removing the blade to make noise free smooth operation including painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler and replacement of PVC twin twisted wire assembling and hanging of ceiling fan and connecting up to ceiling rose or connector to fan its position using new clamp set (clamp, rubber,bush and nut and bolt)including testing complete all as specified and directed. |
| 36 | Disconnecting electrical wire of exhaust fan of size 230 / 300 mm sweep dia and taking down from its position, dismantling blades, cleaning and greasing after removing the blade to make noise free smooth operation including replacement of PVC twin twisted wire assembling and fixing of Exhaust fan and connecting up to ceiling rose or connector to fan its position using new fastening clamp including testing complete all as specified and directed. |
| 37 | Supply and fix in repair sheet metal enclosure MCB DB 8 waySPN double door suitable for 240 V, fixed on walls includingblanking plate as per requirement and taking down unserviceable DBs complete all as specified and directed |
| 38 | Supply and fix in repair MCB SPN 240 Volts, \"C\" series, breaking capacity 10 KA of rating 32 Amps complete all as specified and directed |
| 39 | Fixing only Minature circuit braker (MCBs) of any cap, 240 Volt (serviceable MCB SPN obtained from unserviceable DBs shall be reused) complete all as specified and directed |
| 40 | Supply and fix in repair MCB SP 240 Volts, \"C\" series, breaking capacity 10 KA of rating 5-32 Amps complete all as specified and directed |
| 41 | Fixing only Minature circuit braker (MCBs) of any cap, 240 Volt (serviceable MCB SP obtained from unserviceable DBs shall be reused) complete all as specified and directed |