| 1 | SCHEDULE OF WORKS |
| 2 | Disconnecting faulty/burnt end portion of under ground cable by removing cable from loop after necessary excavation & earth work, relaying and reconnecting the cable by removing faulty/burnt portion of incoming and out going cables at panel boards, preparing fresh terminals with suitable size of thimbles, lugs and glands or gland plates of suitable size and number of cables incoming out going to panel board, complete all as specified and as directed by Engineer-in-Charge.Note : Necessary excavation and earthwork, cables, cable protection works where required will be measured and paid separately under respective items. |
| 3 | Thoroughly checking timer switch, concactors and connections of timer switch along with protection relays, check serviceability, carryingout repairs including replacing of minor spares like connectors, internal wiring and relays complete all as specified and as directed. Note: Major spares like power contactors, timer switch will be measured and paid separately. |
| 4 | Supply and fixing in repairs, analog timer switch with battery backup 3P module, 24 Hours program programmable every 15 min backup of 100 hours current capacity 16 A with changeovercomplete all as specified and as directed. |
| 5 | Supply and fixing in repairs, digital timer switch programmable every 1 min with backup of 6 years 28 memory locations current capacity 16 A weekly program with 1 changeover total 28 programs complete all as specified and as directed. |
| 6 | Supply and fixing in repairs, astronomical programmable timer switch every 1 min backup of 6 years, 28 memory locations, current capacity 16A with 1 change over total 28 programs complete all as specified and as directed. |
| 7 | Supply and fix in repairs, Power contactors, 3-phase current rating 40 Amps coil voltage 24 V AC 1 NO + 1 NC complete all as specified and as directed. |
| 8 | Carrying out repair/maintenance and servicing of High mast light motor and pulley with gear system, replacement of oil for lubrication of pulley including replacement of minor repairs like nut, bolts and washers, belt and provision of suitable handle for manual operation of High mast light fitting complete all as specified. Note: Winding of motor measured and paid separately |
| 9 | Material and labour, for copper winding to high mast light pulley motor of 1 HP and insulating the winding with good quality material by taking unserviceable winding and replacement of minor spares like coupling, PVC blower fan blades complete all as specified and directed |
| 10 | Supply and fix in repairs, SWG rope wire for high mast light frame up and down and replacement of rope/wire suitable size as existing or not less than SWG 4 gauge size complete all as specified and directed. |
| 11 | S&F in replacement of pin type, porcelain, vitreous, white, brown or green insulator, 320 cd 5knincluding one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade complete all as sprcified and as directed. |
| 12 | S&F in replacement of shackle type, porcelain, vitreous, white, brown or green insulator, 320 cd 5kn, 1100 Volts LT of size 100 mm high and 115 mm dia including galvanised mild steel straps of size 31x5 mm, washers, insulator bolts 14 mm dia, washers and nuts etc complete all as sprcified and as directed. |
| 13 | Taking down unserviceabl ACSR Conductor, Supply and lay ACSR Conductor conductor in OH lines conductor (Squirrel / Weasel / Rabbit) including binding with aluminium wire |
| 14 | Taking down defective street light of LED of capacity 25/30/60/90/120W, flood light and building security light fitting of any type from their existing position i.e, poles and bldg and refixing the same after carrying out necessary repair works complete all as directed.Note: (i) Supply only spares like LED driver/LED Strip and SPD, PVC wire/cable will be measured and paid separately under respective items of the BOQ(ii) Cost of nut, bolts & washers for fixing new items shall be included in the unit rate of items. |
| 15 | Supply only surge protection device (SPD) of capacity 8 KV with phase neutral and earth wire incoming and outgoing both sides complete all as specified and directed. |
| 16 | Supply only surge protection device (SPD) of capacity 5 KV with phase neutral and earth wire incoming and outgoing both sides complete all as specified and directed. |
| 17 | Supply& fix in repairs, LED driver suitable for street light fitting of 25 W LED, complete all as specified and directed. |
| 18 | Supply& fix in repairs, LED driver suitable for street light fitting of 35 to 45W LED, complete all as specified and directed. |
| 19 | Supply& fix in repairs, LED driver suitable for street light fitting of 70 to 90 W LED, complete all as specified and directed. |
| 20 | Supply& fix in repairs, LED driver suitable for street light fitting of 120 W LED, complete all as specified and directed. |
| 21 | Supply and fix, 3 core, 2.5 sqmm PVC insulated, PVC sheathed multistranded flexible copper conductor cable, drawn through existing conduit / pipe from junction box to fitting complete including taking down old unserviceable cable all as specified. |
| 22 | Disconnection and removing the unserviceable MCB, Supply and Fixing MCBTPN 16-32 Amps complete all as specified and as directed. |
| 23 | Disconnection and removing the unserviceable MCB, Supply and Fixing MCBTPN 40-100 Amps complete all as specified and as directed. |
| 24 | Supply and fix in repairs, MCCB 4 pole, 16 kA, 63 Afixed type includng with connecting links and accessories complete all as specified |
| 25 | Supply and fix in repairs, MCCB 4 pole, 16 kA, 100 Afixed type includng with connecting links and accessories complete all as specified |
| 26 | Supply and fix in repairs, MCCB 4 pole, 16 kA, 125 Afixed type includng with connecting links and accessories complete all as specified |
| 27 | Supply and fix in repairs, MCCB 4 pole, 25 kA, 160 Afixed type includng with connecting links and accessories complete all as specified |
| 28 | Supply and fix in repairs, MCCB 4 pole, 35 kA, 200 Afixed type includng with connecting links and accessories complete all as specified |
| 29 | Supply and fix in repairs,junction box made from FRP sheet ready made of size not less than 300x200x125 mm having 100 A capacity including RYB and neutral with aluminum busbar with 4 way connector, including provisio of MCB SP 6 Amp 10 kA 240 V - 01 No.and fixed to pole / wall with and including mild steel clamp of size 25 mm x 5 mm duly painted with one coat of red oxide and two coats of enamel / silver paint, with suitable lugs complete all as specified and as directed. |
| 30 | Supply and fix in repairs, junction box made from FRP sheet ready made of size not less than 250x180x100 mm having 100 A capacity including RYB and neutral with aluminum busbar with 4 way connector, including provision ofMCB SP 6 Amp 10 kA 240 V - 01 No.and fixed to pole / wall with and including mild steel clamp of size 25 mm x 5 mm duly painted with one coat of red oxide and two coats of enamel / silver paint, with suitable lugs complete all as specified and as directed. |
| 31 | Taking down burnt / unserviceable cable, Supply and fixing 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor 6 sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections of one twin core cable flat or circular complete, all as specified and as directed. |
| 32 | All as per Serial item no 30 here-in-above, but cable of size 10 sqmm twin core complete, all as specified and as directed. |
| 33 | M&L for preparationold painted steel tubular pole 8 to 11 m long, clamps, brackets, channel, cross arms, bracing support, pipe of support for cable and swan neck etc including zebra painting at bottom up to 1.5 mtr above from the PCC coping and writing pole No with white paint complete etc complete all as specified and as directed.Note: Pole number shall be marked with white enamel paint over a base of size 20cmx20cm on prepared with two coats of black enamel paint on pole surfaces. |
| 34 | M&L painting to PCC pole/ Steel tubular poles with two coats of cement base paint of approved colour shed and writing Pole numberswith white paint having black background enamel paint suitable for outdoor, including cleaning of poles, removing creeper etc from pole and as specified. |
| 35 | Takin down unserviceable steel tubular swaged poles, providing material and labour for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31, 9.0 meter long, single swan neck type inclusive of one primer coat of red oxide zinc chrome primer and two coats of aluminium paint incl preparation of surfaces complete all as specified and directed. The poles shall confirm to IS - 2713 & each component pipe shall be ISI Marked & confirm to IS - 1161. Note: Earth work and PCC foundation shall be measured and paid separately. |
| 36 | Material and labour for plain cement concrete of 1:4:8, type D2 (using 40 mm graded granite stone aggregate) as in foundations, filling and mass concrete for steel pole complete all as specified. |
| 37 | Material and labour for plain cement concrete of1:2:4, type B1 (using 20 mm graded granite stone aggregate) as in coping for steel pole including necessary formwork complete all as specified. |
| 38 | Supply and fixing aviation obstruction light fitting including lamp and connecting with suitable size cable including taking down old unserviceable one complete all as specified and as directed. |
| 39 | Takin down unserviceable cross arms and S&F cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated and inclusive of one primer coat, one under aluminium coat and one aluminium finishing coat of paint complete all as specified. |
| 40 | Takin down unserviceabletimer switch and S&F Digital time switch with out door enclosure DB programmable every 1 min with 1 changer over of rating 65 Amps 230 voltsuitablefor switching on/ off lights on time scheduling basis with suitable contactor for three phase 415 volt supply with time setting features On/Off complete all as specified and directed. |
| 41 | Material and labour for removing old unserviceable LT OH linejumpers/ connecters/ taps/ sleeves and insulators of any type and size rejumpering the same by supply and fixing suitable size of ACSR conductor as jumpers replacing obtained serviceable insulators and testing the OH lines after repair/replacement and maint of jumpersall as specified and directed.Note: Jumpers set of two to Six to be replaced in one job at one pole point shall be included in this item.Insulators shall be measured and paid separately under relevant item of the schedule. |
| 42 | S&F PVC line separator suitable for 3 phase 4 wire and 02 wire of street light of LT line all as directed. |
| 43 | Supply and fix self adhesive reflective radium stickers 75 mm wide around the street light poles 1.5 above ground level complete all as specified and directed. |
| 44 | M&L in repair for Straight throughjoint 1100 volt complete with jointing material and accessories suitable for 6 to 25 Sqmm 2 Core complete all as specified and as directed. |
| 45 | M&L in repair for Straight throughjoint 1100 volt complete with jointing material and accessories suitable for 10 to 50 Sqmm 3.5 Core complete all as specified and as directed. |
| 46 | M&L in repair for Straight through joint 1100 volt complete with jointing material and accessories suitable for 70 to 150 Sqmm 3.5 Core complete all as specified and as directed. |
| 47 | M&L in repair for Straight through joint 1100 volt complete with jointing material and accessories suitable for 185 to 400 Sqmm 3.5 Core complete all as specified and as directed. |
| 48 | S&F cable end jointing kit for LT, 1100 Volt (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminum conductor cable of size 16 to 50 sqmm with provision of lugs/thimbles/aluminum jumpers for OH/UG connections |
| 49 | All as per Serial Item No 47above here in before but joint of size 70 sqmm to 95 sqmm |
| 50 | All as per Serial Item No 47here in before but joint of size 120 sqmm to 150 sqmm |
| 51 | All as per Serial Item No 47here in before but joint of size 185 sqmm to 240 sqmm |
| 52 | All as per Serial Item No 47here in before but joint of size 300 to 400 sqmm |
| 53 | M & L forlaying XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 3.5 core, 1100 volts, grade of size 50 Sqmm complete all as directed .Note: Necessary excavation and earthwork and cable protection works will be measured and paid for separately. |
| 54 | All as per Serial Item No 52, above here in before but of cross sectional area of 35 sq.mm 3.5 core |
| 55 | All as per Serial Item No 52, here in before but of cross sectional area of 25 sq.mm 4 core |
| 56 | All as per Serial Item No 52, here in before but of cross sectional area of 16 sq.mm 4 core |
| 57 | All as per Serial Item No 52, here in before but of cross sectional area of 10 sq.mm 4 core. |
| 58 | All as per Serial Item No 52, here in before but of cross sectional area of 10 sq.mm 2 core. |
| 59 | Excavation in trenches not exceeding 1.5 mtr depth width and not exceeding 1.5m depth for laying under ground cable in loose/soft soil. |
| 60 | Material and labour cable cushioning using riddled earth by sieving excavated soil as per IS-1255-1983 as in cable cushioning punned depth upto 18 cm thick complete all as specified and directed.Note: Punned thickness will be measured and paid for purpose of the payment. |
| 61 | Returning, filling in, (excavated soils), including spreading, levelling, watering and well ramming in layers not exceeding 25cm. |
| 62 | Removal of surplus soil obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point. |
| 63 | Relaying old serviceable unreinforced pre cast concrete cable cover class LV, Type I, flat, size 250mm x 150mm x 40mm for cable protection complete. Note : Serviceable cable covers obtained while taking out under ground cables shall be reused under this item. |
| 64 | M&L for cutting road up to 45 cm width and depth of road / hard standing and making good disturbed surfaces using PCC type C2(1:3:6) by using 40mm graded stone aggregate for laying pipes, cables, etc., complete all as directed by the Engineer-in -Charge. |
| 65 | Supply and laying unreinforced pre cast concrete cable cover class LV type I flat size 250 x 150 x 40 mm for cable protection |
| 66 | M&L for 40mm dia steel tubes (light grade) galvanised with fittings, laid in trenches/wall for protection of underground earth strip when crossing the road/fixing on wall as in repair complete all as specified and directed. |
| 67 | M&L for 50mm dia steel tubes (light grade) galvanised with fittings, laid in trenches/wall for protection of underground earth strip when crossing the road/fixing on wall as in repair complete all as specified and directed. |
| 68 | S & F GI tube light grade galvanised of size 80 mm with all fitting and fixed to wall and ceiling or laid in floors/under road etc complete all as specdied and directed by Engineer-in- Charge. |
| 69 | Taking down unserviceable light fittings and S&F high efficient LED street light fitting (Warm white) of 45 W 230 V AC outdoor type with high pressure die cast housing with lens IP 66 protection and heat resistant complete all as specified. |
| 70 | Taking down unserviceable light fittings, Supply and fix high efficient LED street light fitting (Warm white) of 70 W 230 V AC outdoor type with high pressure die cast housing with lens IP 66 protection and heat resistant complete all as specified. |
| 71 | Taking down unserviceable light fittings and S & F of 120 Watt LED flood light fittings (Warm White) integral warm white type, with die cast housing with lens IP 66 protection complete all as specified. |
| 72 | Taking down unserviceable light fittings and S & F of 100 Watt LED flood light fittings integral warm white type, with die cast housing with lens IP 66 protection complete all as specified. |
| 73 | Taking down unserviceable light fittings and S & F of 70 Watt LED flood light fittings integral warm white type, with die cast housing with lens IP 66 protection complete all as specified. |
| 74 | Taking down unserviceable light fittings, supply and fix, LED post top lantern 70 W warm white with die cast aluminium spigot, spun aluminium powder coated top cover, aluminium PDC heat sink, opal PC diffuser and clear acrlic, IP 65 complete all as specified. |
| 75 | Taking down unserviceable light fittings, supply and fix, LED post top lantern 25 W with die cast aluminium spigot, spun aluminium powder coated top cover, aluminium PDC heat sink, opal PC diffuser and clear acrlic, IP 65 complete all as specified. |
| 76 | Taking down unserviceable light fittings and S&F LED bollard decorative luminarie 8 Watt complete all as specified and directed |
| 77 | Taking down unserviceable GI bracket of size 40mm dia from the pole / building, providing materla and labour for street light bracket made out of40 mm dia GI tubing medium gradeupto 1.5 mtr long including bending, welding ,drilling holes as required and fixing with flat iron clamps 50x 6 mm thick (02 Nos) with suitable nut, bolts and washers to steel tubular /concrete poles complete, including preparation of steel and iron surface and applying two coats of aluminium paint, first quality, over a coat of primer, etc complete, all as specified and as directed. |
| 78 | All as per Serial item No 76 here-in-above, but GI bracket of size 25 mm dia from the pole / building, providing material and labour for street light bracket made out of25 mm dia GI tubing medium gradeupto 1.5 mtr, clamps 25x3 mm thick clamps complete, all as specified and as directed. |
| 79 | Material and labour, for earthing complete with GI earth plate electrode of size 600x600x6 mm thick burried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI wire 4 mm dia earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel,protected by galvanized iron pipe 40mm bore (Medium grade) allas directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel,wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed after taking down old earthing.( GI wire upto 7.5m including testing consider in this item). |
| 80 | Supply and fix, Feeder pillar box cubicle, outdoor type floor mounted made out of 3mm thick MS sheet and angle Iron of suitable size weather proof/vermin proof shutter type with locking arrangement of cubicaltype prewired with Aluminium busbar 500 Amps for phases and Aluminium busbar 300 Amps for neutral includingsuitable CTs etc and powder coated painting, PCC work and cable glands and lugs complete suitable for andproviding the following in box all as directed by Engineer-in-Charge :- 4 Pole MCCB 250 Amp 50 Hz 415 V with rupturing capacity 35 KA.-01 Nos 4 Pole MCCB 100 Amp 50 Hz 415 V with rupturing capacity 25 KA.-03 Nos |
| 81 | Supply and fix, Feeder pillar box cubicle, outdoor type floor mounted made out of 3mm thick MS sheet and angle Iron of suitable size weather proof/vermin proof shutter type with locking arrangement of cubicaltype prewired with Aluminium busbar 500 Amps for phases and Aluminium busbar 300 Amps for neutral includingsuitable CTs etc and powder coated painting, PCC work and cable glands and lugs complete suitable for andproviding the following in box all as directed by Engineer-in-Charge :- 4 Pole MCCB 250 Amp 50 Hz 415 V with rupturing capacity 35 KA.-01 Nos 4 Pole MCCB 100 Amp 50 Hz 415 V with rupturing capacity 16 KA.-01 Nos4 Pole MCCB 63 Amp 50 Hz 415 V with rupturing capacity 16 KA.-01 Nos |