| 1 | Surface excavation n exc 30cm deep and averaging 15cm deep and getting in hard/dense soil all as specified and directed. |
| 2 | M&L for Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard densecomplete all as specified |
| 3 | M&L for PCC 1:4:8 type D-2 (using 40mm graded stone agg) as in foundation filling and mass concrete complete all as specified and directed. |
| 4 | M&L moorum/red bajri filling in floors or pavings, laid in layers n exc 15cm thick, spread, levelled and rammed including watering complete all as specified and as directed by Engr-in-charge |
| 5 | M&L for broken stone or boulders Hardcore of gauge not exc 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface all as specified. |
| 6 | M&L 100 mm thick PCC (1:4:8 ) type D-2 as in sub base finished even and roughcomplete all as specified and as directed. |
| 7 | M&L Joint free Non - skid coloured ceramic tiles 7 to 10 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry over screed bed of 15 mm thick 1:6 and pointed in white or coloured cement to match complete. |
| 8 | M&L Joint free Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed of 15 mm thick 1:4 and pointed in white or coloured cement to match complete. |
| 9 | M&L for brick work with sub class `B’ bricks, straight on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 10 | M&L for brick work with sub class `B’ bricks, straight on plan to any radius in half brick thick walls, built in CM 1:4. |
| 11 | M&L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed. |
| 12 | M&L for Removing excavated soils to a distance exc 250m but n exc 500m and depositing where directed. |
| 13 | M&L for 40mm thick damp proof course to horizontal or vertical surfaces including necessary formwork in cement concrete 1:2:4 type B-0 using 12.5 mm graded crushed stone aggregate complete all as specifed and directed. |
| 14 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams etc , rough finish surfaces of concrete complete all as specified and as directed |
| 15 | M&L for RCC Type B1 1:2:4 (using 20mm aggregate) for Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specifed and directed. |
| 16 | Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 17 | -ditto- all as per item No.10 above, but 5mm dia and over upto 10mm dia as in stirrups, spacers and binders complete all as specified and directed. |
| 18 | M&L for 15mm thick cement plaster in CM (1:4) on fair faces of brick or concrete surfaces using WPC where ever requiredas per manufacturerer\"s instructions and finishing the surface even and smooth (without using extra cement) etc. incl finishing even and faircomplete all as specified NOTE -WPC shall be measured and paid separetely. |
| 19 | Supply only WPC complete all as specified and directed. |
| 20 | M&L for rendering 15mm thick on fair faces of brick work in CM 1:6 finished even and fair without using extra cement complete all as specified and directed. |
| 21 | M & L for Preparation on new plastered surfaces of wall, and apply two coat of exteriar emulsion paint (Apex) of (Black in Color)over a coat of primer ofcomplete all as specified anddirected |
| 22 | M &L for Preparation ofnew plastered or unplastered surfaces of walls and applying 3mm thick wall care, putty and two coats of distemper oil emulsion(Black In color) , white or tinted over a coat of primer, complete |
| 23 | S&F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet0.50mmthick of any colour having tensile strength of 550 MPAas in roof covering /cladding to wall, fixed with self tapping screws as specified complete all as specified |
| 24 | S&F rolled mild steel sections channel angle Tee section and in tubular sectionas in main and cross beams, hip and jack rafters; purlins,post where connected to common rafters and running rails fixed with angle cleat or other connecting plates conforming to Fe 410-W Gde-E-250, quality A complete all as specified and directed. |
| 25 | M&L for two coats of synthetic enamel painting over a coat of red oxide zinc chrome primer on steel surfaces over 10cm width or girth including preparation of surface complete. |
| 26 | M&L for providing PCC 1:2:4 type B-0 as in roof kerbs or mud stops rouded or chamfered on edges (using 12.5mm graded stone aggregate) complete all as specifed and directed. |
| 27 | M&L for 75mm thick cement concrete 1:3:6 type C-2 using20mm graded agg as in plinth protection incl all necessary form work & finishing surface even & smooth using extra cement complete all as specified and as directed. |
| 28 | S & Ffalse ceiling at all heights with GRG (Glass Fibre With Semi Reinforced Gypsum) false ceiling tiles ofSize 595 x 595 mm of approved texture design and patterns with black color or after fixing painting will be done having moisture content less than 2%, humidity resistance edged GRG thick square edged of 99%, NRC0.50 to 0.75 as per IS false ceiling GRG false ceiling 8225:1987, Noncombustible as per BS tiles tiles 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true with semi perforated 12mm thick micro tegular edged GRG false ceiling tiles horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main- T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1 OOOmm length and Lshape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 29 | S&F plain framed solid, st chowkhats and frames, wrought rebated on solid rounded or chamfered put together with glue pinned supplied and fixed 2nd class hard wood. |
| 30 | S&Ffactory made 35mm thick flush shutters, solid core construction, with block board core andplywood face panesls, commercial type on both sides, complete all as specified and as directed. |
| 31 | M&L for 0.9mm thick decorative laminate type 1 of surface finish, colour (BLACK COLOR) and patters as approved, fixed with approved adhesive as per manufacturer\"s insturctions, complete all as specified. |
| 32 | S&FAluminium die cast body Door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg complete. |
| 33 | S&F 35 mm thick glazed and skelton shutter open rebated and prepared to receive glass, gauge etc,(with out sash bars) edges of framing plain chamfered or rounded fitted with cut or mitred beads for securing glass etc. size of members of shutters as specified in SSR Part-I, Sec-8, clause 8.23(a) 2nd class hard wood (Shisham),complete all as specified and as directed |
| 34 | S&F 150 mm overall length floor stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and as directed |
| 35 | S&F Stainless Steel Decorative Cabinet Handle 150 mmcomplete all as specified and directed |
| 36 | S & F 200 mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and as directed. |
| 37 | S&F Butt hinges medium weight cold rolled mild steel of 100mm long complete all as specified and directed. |
| 38 | S&F Brass, sliding door bolt with sandand or die-cast brass hasp,staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed fixed 375 mm long complete all as specified and as directed. |
| 39 | M&L RCC 1:2:4 (using 20mm garded stone agg) as in foundation, including rafts, footings, foundation beams, plinth beams; bases for columns, column, pillars, piers, posts and structs etc, basement slabs, under reamed piles and mass concrete, including necessary formwork complete, all as specified & directed |
| 40 | Demolition of brick work built in cement mortar all as specified |
| 41 | Exceptbrick work with sub class `B’ bricks, straight on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 42 | M&L for preparation of newly plastered surfaces of wall , finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed. |
| 43 | M&L cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in copingetc incl weathering slighting rounded or chamfered angles and throating incl necessary form work . |
| 44 | S&F Framed work as grills, gratings, etc. with ends of bars shouldered and/or rivted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed ballusters; walk ways; railing; framework of watertanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and as directed. |
| 45 | S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) |
| 46 | S&F concertina coil 600mm dia (in stretched position ) hot dip galvanised steel wire coated with anticorrosive paint,making diamon shape with help of dove tail clips (18 SWG) , fixed to the MS angle iron fencing post with & including binding wirecomplete all as specified and directed |
| 47 | Supply & Fixing point wiring for one light point/ fan (independent) point controlled by one, one way switch with 1.5Sqmm size, PVC insulated and unsheathed 1100volts grade, single core stranded (multistrand) copper conductor (FRLS)PVC cable drawn into & including medium grade PVC conduit (not less than 20mmouter dia ) with all fittings and accessories fixed concealed(including chase cutting in brick/ stone masonry walls for fixing conduit and plastering and whitewash/colouring the external surface and matching the same with existing surface) andsunk cast iron or pressed steel terminal boxes for mounting fittings like switches, sockets & fan regulators etc with 3 mm thick plastic laminated sheet covers fixed with brass screws and cup washersincluding one continuous run of PVC insulated (green colour) 1.5 Sqmm multistrandedcopper conductor cable earth wire and connected to earth dolly complete all as specified and directed Note:- wiring shall be done in colour coding as directed by Engineer in charge. |
| 48 | All as per item No.1 herein before but one socket outlet 5 Amps on the same board. |
| 49 | All as per item No.1 herein before butone 3 pin socket outlet 5 Amps independent. |
| 50 | All as per item No. 1 above but with 2.5 Sq mm two single core and 2.5 Sq mm one single core as earth wire for 5/15 Amps socket. |
| 51 | All as per item No. 1 above but with 4 Sq mm two single core and 4 Sq mm one single core as earth wire for 5/15 Amps socket. |
| 52 | Suppy & Fixing switch piano flush type single pole, one way 5 Amp complete all as specified and directed. |
| 53 | Supply & Fixing switch piano, flush type single pole 15 Amp complete all as specified and directed. |
| 54 | Supply & Fixing socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type complete all as specified and directed. |
| 55 | Supply & Fixing socket outlet 2 in 1, 3 pin, 5 Amp flush type complete all as specified and directed. |
| 56 | S&F ceiling rose surface bakelite3 terminal with base plate. |
| 57 | S&F sheet metal enclosure with socket plug top and MCB single pole and netural enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 Amp 240 Volts complete. |
| 58 | Supply & Fixingsheet metal enclosure forSPN DBs (double door type) Single pole and neutral 8 way including blanking plate as required with 200 Amps rated bus bar, 240 volts fixed complete all as specified and directed . |
| 59 | Material and labour for Sub main wiring with 2 run of 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to and including Rigid non metallic PVC conduit (ISI marked) Heavy grade, 20 mm dia (external) inclusive ofjunction/terminal boxes, all fittings and accessories fixed concealed with and including 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DBincluding cutting and chasing and making good surface as original by plastering and whitewash/ colour/ distemper etc including taking down existingold sub main wiring complete all as specified.Note :1 The cost of earth wire is included in the quoated rates. 2.Two run of 6 sqmm, one run of 6 sqmm and one run of PVC conduit will be measured as one unit ie one running metre” |
| 60 | Supply and fixing LED lights fitting 1x 20W (warm/milky white as required on site), 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and life of tube light not less than 50,000 hours.completeall as specified and directed.. |
| 61 | S & F LED light fitting 1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. Make : Havells cat pat HEXAFT10WLED857SSYMBOPC or equivalent cat part in makephillips/wippro/Bajaj & C&S .Note:- Contractor shall submit 2 year warrenty of material from manufracturer alongwith purchase voucher. |
| 62 | Supply & Fixingsheet metal enclosure forSPN DBs (double door type) Single pole and neutral 4way including blanking plate as required with 200 Amps rated bus bar, 240 volts fixed complete all as specified and directed . |
| 63 | Supply & Fixing 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of SPN 40 to 63 Amp and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed . |
| 64 | Supply & Fixing 240V, 10KA \"B\" curve miniature circuit breaker (MCB) of single pole 5 to 32 Amp and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed . |
| 65 | M&L for Earthingcomplete with galvanized sheet earthplate electrodes 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2. 25mtr deep below ground level) with top edge of plat not less than 1.5 mtr below normal ground level connected to galvanizedearth lead wire 4.0 mm dia as earthing lead by means of bolts, nuts , check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3and including excavation and earth work, GI pipe light grade 15 mm bore for protection of GI wire from earth electrode to and incl the earth test point of galvanized Iron/steel of size 75x75x 25mm,supplying and laying charcoal dust, common salt, PCC 1:2:4 typeB1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6 mm dia TMT bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh,20 mm dia GI pipe light grade for wateringand connected to earth test point including brazing at all joints except at test point and testing complete all as specified and directed by Engr-in-Charge. |
| 66 | Supply and fixing LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type(warm/milky white as required on site) with high efficiency PMMAdiffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling, life of tube light not less than 50,000 hours including connecting up with driver three core flexible copper conductor cases of suitable size complete.Make Havells/Phillips/Bajaj/C&S Note:- Contractor shall submit 2 year warrenty of material from manufracturer alongwith purchase voucher. |
| 67 | Supply & Fixing 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of single pole neutral (SPN) and current carrying capacity 32 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed . |
| 68 | Supply, laying and testing cable XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core. |
| 69 | Removal of surplus soil not exceeding 50 Mtr and depositing where directs at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed by Engr-in-Charge. |
| 70 | M&L for sand cushioning in trenches spreading and consolidation 8cm thick before laying the cable & 15 cm of sand after laying the cable complete all as specified |
| 71 | M&L for laying of bricks well burnt sub class ‘B’ (old pattern) laid flat for cable protection width equal to the lengrth of brick complete all as specified . |
| 72 | M & L galvanised steel water tubing \"light grade\"40 mm bore with all fittings laid under the roads, drains, culverts and fixed on poles etc complete all as specified and directed . |