Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | CIVIL WORKEarth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.50m initial lift including rough dressing breaking clods maximum 5cm to 7cm & laying in layers not exceeding 0.3m depth for the work complete including shoring, shuttering & dewatering (if required) with cost of all Labour, Labour cess ,Hire & Running charges of the water pumps, Sundries, T & P required for the work complete as directed by the Engineer- in- charge. |
| 2 | GALLERY & COMMON FACILITY CENTER |
| 3 | COVER DRAIN |
| 4 | PLINTH PROTECTION |
| 5 | SECURITY SHEAD & GATE |
| 6 | BOUNDARY WALL |
| 7 | PAVER ROAD & PARKING |
| 8 | DRAINAGE WORK |
| 9 | CONSTRUCTION OF BASKETBALL, VOLLEYBALL & LAWN TENNIS COURT |
| 10 | BASKET BALL COURT |
| 11 | VOLLEY BALL COURT |
| 12 | LAWN TENNIS COURT |
| 13 | Cutting in disintegrated rock not requiring blasting to be removed by pick axes and crow bars and depositing materials within 50m initial lead and 1.5m initial lift including rough dressing as per direction and specification of the department including stacking the useful materials separately as ordered. |
| 14 | GALLERY & COMMON FACILITY CENTER |
| 15 | SECURITY SHEAD & GATE |
| 16 | Back filling with available excavated earth in foundation and trenches in layer not exceeding 20 cm in depth watering ramming with a lead upto 50m and lift upto 1.5m etc. incluing cost, conveyane, cost of all materials and labour etc complete as per direction and specification of Engineer in charge |
| 17 | GALLERY & COMMON FACILITY CENTER |
| 18 | SECURITY SHEAD & GATE |
| 19 | BOUNDARY WALL |
| 20 | DRAINAGE WORK |
| 21 | Carriage / disposal of excavated surplus earth from the worksite by mechanical means within a lead of 5Km including loading and unloading etc. complete. in all respect as per direction of Engineer-in-Charge. |
| 22 | GALLERY & COMMON FACILITY CENTER |
| 23 | SECURITY SHEAD & GATE |
| 24 | BOUNDARY WALL |
| 25 | Supplying and filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer-in-charge |
| 26 | GALLERY & COMMON FACILITY CENTER |
| 27 | COVER DRAIN |
| 28 | PLINTH PROTECTION |
| 29 | SECURITY SHEAD & GATE |
| 30 | BOUNDARY WALL |
| 31 | PAVER ROAD & PARKING |
| 32 | DRAINAGE WORK |
| 33 | CONSTRUCTION OF BASKETBALL, VOLLEYBALL & LAWN TENNIS COURT |
| 34 | BASKET BALL COURT |
| 35 | VOLLEY BALL COURT |
| 36 | LAWN TENNIS COURT |
| 37 | Plain cement concrete (1:2:4) using 12mm size black hard crusher broken granite chips of approved quality from approved quarry including hoisting, lowering and laying concrete in layers, watering, curing etc. complete including cost, conveyance, royalties of all materials with labour,labour cess and T&P etc. required for the work complete as per the direction of the Engineer-in-charge. |
| 38 | PLINTH PROTECTION |
| 39 | Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties of all materials and cost of all labours,labour cess, T&P etc complete as per the direction of the Engineer-in-charge. |
| 40 | GALLERY & COMMON FACILITY CENTER |
| 41 | COVER DRAIN |
| 42 | SECURITY SHEAD & GATE |
| 43 | BOUNDARY WALL |
| 44 | SPORTS FACILITIES |
| 45 | BASKET BALL COURT |
| 46 | VOLLEY BALL COURT |
| 47 | LAWN TENNIS COURT |
| 48 | Cement concrete of proportion (1:4:8) in foundation and floors using 4cm size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6\") thick to the required level ramming, watering, curing etc. complete including cost, conveyance, royalties of all materials with all labour and T&P required for the work etc. complete in all respect and as per the direction of the Engineer-in-charge. |
| 49 | PLINTH PROTECTION |
| 50 | DRAINAGE WORK |
| 51 | R.C.C. work of M-20 in following works using 12 mm. to 20 mm. (½” to ¾”) size (20 mm. not to exceed 25%) hard black crusher broken granite stone chips of approved quality from approved quarry including hoisting, lowering, laying and compacting concrete, watering curing, centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties, taxes of all materials with all labour,labour cess and T & P required for the work etc. complete in all respect but excluding the cost and conveyance of M.S. rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position and as per the direction of the Engineer-in-charge. |
| 52 | COVER DRAIN |
| 53 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 25 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position. |
| 54 | GALLERY & COMMON FACILITY CENTER |
| 55 | GROUND FLOOR |
| 56 | Foundation & bases of column |
| 57 | Plinth Beam |
| 58 | Columns |
| 59 | Roof Beam |
| 60 | Lintel |
| 61 | Chajja |
| 62 | R.C.C. floor and roof slab |
| 63 | R.C.C. staircase |
| 64 | FIRST FLOOR |
| 65 | Columns |
| 66 | Roof Beam |
| 67 | Lintel |
| 68 | Chajja |
| 69 | R.C.C. floor and roof slabs |
| 70 | R.C.C. staircase |
| 71 | SECURITY SHEAD & GATE |
| 72 | GROUND FLOOR |
| 73 | Foundation & bases of column |
| 74 | Plinth Beam |
| 75 | Pedestal & Columns |
| 76 | Roof Beam |
| 77 | Lintel |
| 78 | R.C.C. floor and roof slab |
| 79 | FIRST FLOOR |
| 80 | Columns |
| 81 | Roof Beam |
| 82 | R.C.C. floor and roof slabs |
| 83 | BOUNDARY WALL |
| 84 | Foundation & bases of column |
| 85 | Plinth Beam |
| 86 | Pedestal & Columns |
| 87 | RCC Band |
| 88 | DRAINAGE WORK |
| 89 | Foundations, footings, bases of columns, etc. for mass concrete |
| 90 | RCC Wall |
| 91 | Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) etc. including bending, binding, welding, wastage & over lapping and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge. |
| 92 | GROUND FLOOR |
| 93 | GALLERY & COMMON FACILITY CENTER |
| 94 | COVER DRAIN |
| 95 | SECURITY SHEAD & GATE |
| 96 | BOUNDARY WALL |
| 97 | DRAINAGE WORK |
| 98 | FIRST FLOOR |
| 99 | GALLERY & COMMON FACILITY CENTER |
| 100 | SECURITY SHEAD & GATE |
| 101 | Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. |
| 102 | GALLERY & COMMON FACILITY CENTER |
| 103 | COVER DRAIN |
| 104 | PLINTH PROTECTION |
| 105 | SECURITY SHEAD & GATE |
| 106 | Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. |
| 107 | GROUND FLOOR |
| 108 | GALLERY & COMMON FACILITY CENTER |
| 109 | SECURITY SHEAD & GATE |
| 110 | BOUNDARY WALL |
| 111 | FIRST FLOOR |
| 112 | GALLERY & COMMON FACILITY CENTER |
| 113 | SECURITY SHEAD & GATE |
| 114 | Fly Ash brick masonry in cement mortar (1:4) in super structure using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. |
| 115 | GALLERY & COMMON FACILITY CENTER |
| 116 | SPORTS FACILITIES |
| 117 | BASKET BALL COURT |
| 118 | VOLLEY BALL COURT |
| 119 | LAWN TENNIS COURT |
| 120 | Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.(INSIDE WALL) |
| 121 | GROUND FLOOR |
| 122 | GALLERY & COMMON FACILITY CENTER |
| 123 | SECURITY SHEAD & GATE |
| 124 | BOUNDARY WALL |
| 125 | FIRST FLOOR |
| 126 | GALLERY & COMMON FACILITY CENTER |
| 127 | SECURITY SHEAD & GATE |
| 128 | Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
| 129 | GROUND FLOOR |
| 130 | GALLERY & COMMON FACILITY CENTER |
| 131 | SECURITY SHEAD & GATE |
| 132 | FIRST FLOOR |
| 133 | GALLERY & COMMON FACILITY CENTER |
| 134 | SECURITY SHEAD & GATE |
| 135 | Providing 18mm thick cement plaster on external surfaces of building in two layers consisting of inner layer 12mm thick in CM 1:6 (1 cement : 6 coarse sand) and outer layer of 6mm thick cement plaster 1:4 ( 1 cement : 4 coarse sand) mixed with integral water proofing material of including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, royalties, scaffolding, staging, watering before plastering and curing, sundries and T&P etc. complete as per direction of the Engineer-in-charge. (OUTSIDE WALL) |
| 136 | GALLERY & COMMON FACILITY CENTER |
| 137 | GROUND FLOOR |
| 138 | FIRST FLOOR |
| 139 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
| 140 | GROUND FLOOR |
| 141 | COVER DRAIN |
| 142 | PLINTH PROTECTION |
| 143 | SECURITY SHEAD & GATE |
| 144 | FIRST FLOOR |
| 145 | SECURITY SHEAD & GATE |
| 146 | Providing neat cement punning over plastered/ concrete surface including watering and curing complete with cost, coveyance, loading and unloading, royalties of all materials and cost of all labour, T&P and scaffolding required for the work etc. as directed by the Engineer in charge. |
| 147 | COVER DRAIN |
| 148 | Supplying, fitting and fixing vetrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm Color / Printed series (Homogenous) of approved make (JOHNSON / RAK/ KAJARIA/ SOMANY) in floors on 20mm thick bed of C.M. (1:4) (1cement:4course sand) and filling the joint with white cement mixed with pigment to match the shades of the tile including cost of all materials, labour, labour cess, T&P etc. required for the work complete in all respect as directed by the Engineer in charge. |
| 149 | GROUND FLOOR |
| 150 | GALLERY & COMMON FACILITY CENTER |
| 151 | SECURITY SHEAD & GATE |
| 152 | Providing, fitting, fixing vitrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm Color / Printed series (Homogenous) of approved make (JOHNSON / RAK/ KAJARIA/ SOMANY) as directed by Engineer-in-charge in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials all labour,labour cess complete in all respects as directed by the Engineer in charge. |
| 153 | GROUND FLOOR |
| 154 | GALLERY & COMMON FACILITY CENTER |
| 155 | SECURITY SHEAD & GATE |
| 156 | Fixing granite tiles of approved dimension area above 0.4 sqm (20mm thick) in floor, treads of steps and landing on 20mm thick bed of cement mortar (1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials complete in all respects as per direction of Engineer-in-Charge. |
| 157 | GROUND FLOOR |
| 158 | GALLERY & COMMON FACILITY CENTER |
| 159 | SECURITY SHEAD & GATE |
| 160 | Fixing granite tiles of approved dimension area above 0.1 up to 0.4 sqm (10mm thick) in Dados, treads of steps and landing on 12mm thick cement mortar (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials complete in all respects as per direction of Engineer-in-Charge. |
| 161 | GROUND FLOOR |
| 162 | GALLERY & COMMON FACILITY CENTER |
| 163 | Providing and fixing in position wood plastic composite door frame with appropriate length of ETA Approved carbon steel galvanized (minimum 5 microns) double threaded 6.8 grade Polyamide PA 6 grade sleeve HRD C 10 anchor suitable for fastenings both on concrete & masonary/aerated blocks including cost of all materials, labours, T & P etc required for the work. complete in all respect as directed by the Architect/Engineer-in-charge.(Approved By Jajpur Court) |
| 164 | GROUND FLOOR |
| 165 | GALLERY & COMMON FACILITY CENTER |
| 166 | SECURITY SHEAD & GATE |
| 167 | Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete in all respect as per the direction of the Engineer-in-Charge. |
| 168 | GROUND FLOOR |
| 169 | GALLERY & COMMON FACILITY CENTER |
| 170 | SECURITY SHEAD & GATE |
| 171 | Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and design with cost of all materials & labour, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge. |
| 172 | GROUND FLOOR |
| 173 | GALLERY & COMMON FACILITY CENTER |
| 174 | SECURITY SHEAD & GATE |
| 175 | BOUNDARY WALL |
| 176 | Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make (JK White/ Birla white or equivalent make duly approved by Engineer-in-Charge) and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge. |
| 177 | GROUND FLOOR |
| 178 | GALLERY & COMMON FACILITY CENTER |
| 179 | SECURITY SHEAD & GATE |
| 180 | BOUNDARY WALL |
| 181 | FIRST FLOOR |
| 182 | GALLERY & COMMON FACILITY CENTER |
| 183 | SECURITY SHEAD & GATE |
| 184 | Priming one coat with wall cement primer (water bound) to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess T&P etc. complete as per the direction of the Engineer-in-charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge). (INSIDE) |
| 185 | GROUND FLOOR |
| 186 | GALLERY & COMMON FACILITY CENTER |
| 187 | SECURITY SHEAD & GATE |
| 188 | FIRST FLOOR |
| 189 | GALLERY & COMMON FACILITY CENTER |
| 190 | SECURITY SHEAD & GATE |
| 191 | Painting two coats with plastic emulsion paint with a approved quality primer to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge). |
| 192 | GROUND FLOOR |
| 193 | GALLERY & COMMON FACILITY CENTER |
| 194 | SECURITY SHEAD & GATE |
| 195 | FIRST FLOOR |
| 196 | GALLERY & COMMON FACILITY CENTER |
| 197 | SECURITY SHEAD & GATE |
| 198 | Wall painting two coats with Antifungal weather coat paint (1st quality) exterior grade of approved make & approved shade over a coat of primer to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge). |
| 199 | GROUND FLOOR |
| 200 | GALLERY & COMMON FACILITY CENTER |
| 201 | SECURITY SHEAD & GATE |
| 202 | BOUNDARY WALL |
| 203 | FIRST FLOOR |
| 204 | GALLERY & COMMON FACILITY CENTER |
| 205 | SECURITY SHEAD & GATE |
| 206 | Priming one coat with wall cement primer (water bound) to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess T&P etc. complete as per the direction of the Engineer-in-charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge). (OUT SIDE) |
| 207 | GROUND FLOOR |
| 208 | GALLERY & COMMON FACILITY CENTER |
| 209 | SECURITY SHEAD & GATE |
| 210 | BOUNDARY WALL |
| 211 | FIRST FLOOR |
| 212 | GALLERY & COMMON FACILITY CENTER |
| 213 | SECURITY SHEAD & GATE |
| 214 | Painting two coat with approved synthetic enamel paint to new iron work including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge). |
| 215 | GROUND FLOOR |
| 216 | GALLERY & COMMON FACILITY CENTER |
| 217 | SECURITY SHEAD & GATE |
| 218 | BOUNDARY WALL |
| 219 | Providing approved primer of one coat to the Iron work including cost of all materials, labour, Tools & Plant, Brushes etc. complete in all respects as directed by Engineer-In-Charge. |
| 220 | GROUND FLOOR |
| 221 | GALLERY & COMMON FACILITY CENTER |
| 222 | SECURITY SHEAD & GATE |
| 223 | BOUNDARY WALL |
| 224 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. (Make-JINDAL ) |
| 225 | GALLERY & COMMON FACILITY CENTER |
| 226 | GROUND FLOOR |
| 227 | Providing 2.5cm thick Grading Concrete over roof slab with cement concrete (1:2:2) using 6mm size black hard granite crusher broken chips and screened & washed sharp sand for mortar and finished smooth to the rough surface of slab including watering and curing with cost, conveyance, royalties of all materials with cost of all labour, labour cess and T&P required for the work etc. complete in all respect as directed by the Engineer in charge. |
| 228 | FIRST FLOOR |
| 229 | GALLERY & COMMON FACILITY CENTER |
| 230 | SECURITY SHEAD & GATE |
| 231 | Providing & applying of pre constructional anti-termite treatment by drilling 12mm dia holes at distance of 30cm @ junction of wall & floor about 300mm apart deep enough to reach the soil below & chemical emulsion (IMIDACHLOPRIED 30.5SC mixed with 47.5ltr water) pumped these holes to soak the soil @ 1 ltr solution of each hole as per manufactures specification & the holes should be pluged the filling materials including cost of all materials, labour,conveyance, T&P , all taxes and hire charges of machinaries as per direction of Engineer-in-charge.(Make-premise-BAYER,Paxton-FMC,ozie-KALYANI) |
| 232 | GALLERY & COMMON FACILITY CENTER |
| 233 | SECURITY SHEAD & GATE |
| 234 | Providing and fixing of UPVC sliding windows 2/3 track sliding-60 series/Top hung ventilator of any approved make ,duly manufactured using upvc reinforced profiles of 62mm x 60mm x 2.25mm for outer frame, 66mm x 38mm x 2.25mm for sliding shutter frames capable of mounting single glazing system,structurally reinforced with hot dip galvanised upto 50 microns of minimum thickness of 1.2 mm prefabricated and welded through fusion welding & the window sash shall be fitted with 5 mm thick clear float glass of reputed make duly fixed with EPDM weathering seal including the cost of all materials,necessary locking arrangements ,fittings,cost of labour,T&P ,etc complete as per direction of Engineer-in-charge.(Make-FENESTA/ Koemmerling/ Saint Gobain/ Prominance) |
| 235 | GROUND FLOOR |
| 236 | GALLERY & COMMON FACILITY CENTER |
| 237 | SECURITY SHEAD & GATE |
| 238 | FIRST FLOOR |
| 239 | GALLERY & COMMON FACILITY CENTER |
| 240 | Supplying , fitting and fixing of openable UPVC doors with door frame of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures etc complete as per direction of Engineer-in-charge.(Make-FENESTA/ Koemmerling/ Saint Gobain/ Prominance) |
| 241 | GALLERY & COMMON FACILITY CENTER |
| 242 | Providing and lying integram cement based water proffing traetment including preparertion of surface as required for treatment of roofs, balconies, terrace etc consisting of following operations: (a) Applying a slurry cot of neaat cement using 2.75kg/sqm of cement aadmixed with water proffing compound comforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using briken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortr 1:5 (1 cement : 5 coaarse sand) admixed with water proffing ompound conforming to IS : 2645 and approved by Engineer-in-charge over 20mm thick laayer of cement mortr of mix 1:5 (1 cement 5 coarse saand) admixed with water proffing compound conforming to IS : 2645 and approved by Enginer-in-charge to required slope and treating similarly the adjoining wall up to 300 mm height including rounding of junctions of waall and slabs. (c) After two dys of proper curing applying a second coat of cement slurry using 2.75 kg/sqqm of cement admixed with water proffing compound conforming to IS : 2645 and approved by Engneer-in-charge. (d) Finishing the surface with 20mm thick jointless cement mortar of mix 1:4 (1 cement : 4 Coarse cement sand) admixed with water proffing compound conforming to IS : 2645 and approved by Engneer-in-charge (approved jajpur court builibing) |
| 243 | FIRST FLOOR |
| 244 | GALLERY & COMMON FACILITY CENTER |
| 245 | SECURITY SHEAD & GATE |
| 246 | Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8 mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdor floors such as footpath, courtyard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. |
| 247 | GALLERY & COMMON FACILITY CENTER |
| 248 | TENSILE FIBER STRUCTUREDesign, Supply and Installation of tensile membrane fabric 1050 GSM, both sides PVDF coat, with tensile strength 280/ 280 daN/5cm, tear strength 30/ 28 daN of serge Ferrari or equivalent as per the manufacturer\"s specification and 15-year manufacturer\"s warranty or equivalent. Flame Retardancy M2/NFP92-507, The membrane shall be cut and manufactured with a high-frequency PVC welding machine. The rate is inclusive of all fittings and fixtures. |
| 249 | Design, Supply, fabrication and erection of ms steel structures for tensile fabric. Including color, primer, pipe bending, materials shifting including all machinery, labor, tools and hydra. |
| 250 | Removing old lime or cement plaster from walls including raking out joints 12 mm deep and removing the debris within 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge. |
| 251 | Dismantling brick or stone masonry in lime or cement mortar above 3m height including stacking the useful materials for re-use and removing the debris with in 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge. |
| 252 | Dismantling and removing R.C.C. columns beams slab staircase landing lintels including stacking the useful materials for reuse and removing the debris within 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge. |
| 253 | Disposal of excess earth by mechanical means / manually including cost of loading, unloading, transporting & spreading to a level surface complete in all respects including cost of all labour, tools & plant etc. to complete the work |
| 254 | Upto 5. KM |
| 255 | SITE DEVELOPMENT |
| 256 | PAVER ROAD & PARKING |
| 257 | Cleaning & grubbing road land including uprooting rank vegetation, grass, bushes, shurbes,sapling and trees girth upto 300mm ,removal of stumps of trees cut earier and disposal of unsevicable materials and stacking of servicable materials to be used or auctioned up to lead of 1000 meters including removal and disposal of top organic soil not exceeding 150mm thickness |
| 258 | Loosening and Compacting original ground supporting embarkment to facilitate placement of first layer of embarkment, scarified to a depth of 150mm ,mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in table 300-2 for embarkment construction & clause 305 of MoSRT&H Specifications for Road & Bridge works (4th Revision) |
| 259 | Construction of granular sub-base by providing Close graded Granular subbase Grading-III material as per table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MoSRT&H Specifications for Road & Bridge works (4th Revision) |
| 260 | Providing & laying of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make,design,colour and size made by Block making machine with proper compaction laid in required patteren etc.comple in all respect conforming to IRC SP- 63:2018 as per direction of Engineer-in-charge. |
| 261 | Providing & laying precast, precured cement concrete (M-25 grade) Kerb stone (400x300x150mm) with graded stonne aggregates & fixing in position & pattern as shown in drawing with cement mortar of (1 cement : 3 coarse sand) including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm) including making drainage opening wherever required including cost of all materials, labour, lead, T&P etc. complete in all respect (excluding GST) as per specification and as directed by Engineer-in-charge. |
| 262 | Supplying and laying of Grass Pavers of M-30 grade MGP-1 (X-type) 60mm thick interlocking type including preparation of sub base with 100mm sand and leveling,laying of interlocking paver block with sand binding and final compaction with plate vibrator finishing the surface including cutting of blocks at the edges with all labour and materials etc complete as per direction of Engineer-in-charge. |
| 263 | Grassing with Providing and laying Grassing with carpet grass(zoysia japonica) including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for mowing including supplying good earth if needed. In rows 5 cm. apart in either direction. |
| 264 | LAND SCAPING WORK |
| 265 | GREENERY DEVELOPEMT THROUGH LAWN |
| 266 | Supply of cow dung manure, well decomposed, garbage free including transportation & delivery at nursery per tractor load etc., all completed |
| 267 | Lifting & spreading of manure uniformly over the surface area as per landscape design/advice of the site in-charge & all completed. |
| 268 | Supply of broad leaf grass turf, disease free, glossy green etc. well grown, carpet formed 2\" thickness about for an area of 15613 sqmtr. Including transportation & delivery at site as per instruction of in-charge at site at 1:5 ratio for dibbling etc., complete all respect. |
| 269 | Dibbling of grass in required spacing including rolling, 1st watering & maintenace of the lawn to make it free from weeds top dressing with fertilizer and pesticide and mixture of grass planting as per instruction of Officer in-charge at site & complete in all respect |
| 270 | PLANTATON OF ORNAMENTAL, SHRUBS, SPECIMEN & DECORATIVE PANTS |
| 271 | Colium potted plants in 10\" size pot, well grown, decorative stage, healthy & disease free including transportation and delivery to the site. |
| 272 | Thuja 3\"ht. Potted plants, well grown, decorative stage, healthy & disease free including transportation and delivery site. |
| 273 | Red Dracena potted plants in 10\" size pot, well grown, decorative stage, healthy & disease free including transportation and delivery to the site. |
| 274 | Bougainvillea potted plants in 10\" size pot, well grown, decorative stage, healthy & disease free including transportation and delivery to the site. |
| 275 | Dracena (Yellow Colour) potted plants in 10\" size pot, well grown, decorative stage, healthy & disease free including transportation and delivery to the site. |
| 276 | Bougainvillea (Poly pack) plants in 10\" size pot, well grown, decorative stage, healthy & disease free including transportation and delivery to the site. |
| 277 | SPORTS FACILITIES |
| 278 | CONSTRUCTION OF BASKETBALL, VOLLEYBALL & LAWN TENNIS COURT |
| 279 | Cleaning & grubbing road land including uprooting rank vegetation, grass, bushes, shurbes,sapling and trees girth upto 300mm ,removal of stumps of trees cut earier and disposal of unsevicable materials and stacking of servicable materials to be used or auctioned up to lead of 1000 meters including removal and disposal of top organic soil not exceeding 150mm thickness |
| 280 | BASKET BALL COURT |
| 281 | VOLLEY BALL COURT |
| 282 | LAWN TENNIS COURT |
| 283 | Providing and fixing of MS welded mesh of size 25x25 mm of dia 2 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. |
| 284 | BASKET BALL COURT |
| 285 | VOLLEY BALL COURT |
| 286 | LAWN TENNIS COURT |
| 287 | RCC M20 grade concrete using 20mm down well graded CBHG chips including all cost of labour, T&P etc. complete. |
| 288 | BASKET BALL COURT |
| 289 | VOLLEY BALL COURT |
| 290 | LAWN TENNIS COURT |
| 291 | Providing & fixing of goal post Supplying and laying of 3 Layer Synthetic Surface which includes one layer of resurfacer, a layer of filler colour coat and a layer of top colour coat followed by International Standard White line marking as per FIFA norms and terms including cost, conveyance, loading, unloading & fixing of materials, cost of labour, T&P etc complete.as per the direction of the architect in charge |
| 292 | BASKET BALL COURT |
| 293 | VOLLEY BALL COURT |
| 294 | LAWN TENNIS COURT |
| 295 | Supplying and laying of 3 Layer Synthetic Surface which includes one layer of resurfacer, a layer of filler colour coat and a layer of top colour coat followed by International Standard White line marking as per FIBA norms and terms including cost, conveyance, loading, unloading & fixing of materials, cost of labour, T&P etc complete.as per the direction of the architect in charge |
| 296 | BASKET BALL COURT |
| 297 | VOLLEY BALL COURT |
| 298 | LAWN TENNIS COURT |
| 299 | DRAINAGE WORK |
| 300 | Carriage / disposal of excavated surplus earth from the worksite by mechanical means within a lead of 5Km including loading and unloading etc. complete. in all respect as per direction of Engineer-in-Charge. |
| 301 | Providing 6mm thick cement plaster in cement mortar of (1:4) to RCC surfaces such as ceilings of roof slabs, stairs, landings, chajja, shelves, columns, beams and lofts etc. including roughening/chipping, scraping and cleaning and finishing the plastered surface smooth using wooden floats, bars, etc. only to proper plumbs and level, making grooves, beads and drip coarse to give required ornamental finish as per drawing including cost of all materials, conveyance, loading and unloading, royalties, cost of all labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge. |
| 302 | NATURAL GRASS - FOOTBALL FIELD WORK |
| 303 | Fine dressing of the ground complete in all respect. |
| 304 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450 x100 mm, reinforced with 8 mm dia T.M.T. hoop bars at 100mm c.c both way, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 3 mm complete, all as per direction of Engineerin- charge. CPWD Rate-I.No.23.09 |
| 305 | Supplying, deliver , stacking on site medium Fine sand 0.2 mm to .75 mm for Natural turf as per specification to the depth of 125mm (Approximate) including loading, unloading, royalty etc. Complete as directed by engineer in charge. |
| 306 | Supplying and stacking at site organic manure from approved source, including carriage upto 5 km lead complete :@ 8 kg sqm |
| 307 | Mixing medium Fine sand( Silica) and organic manure, Spreading and laying leveling watering and Rolling medium Fine sand( Silica) and organic manure |
| 308 | Supplying, deliver, and placing on site Poyta Sandy loam Soil as per directions and free from stone rubbish. The soil should be fresh from quarry, including loading, unloading, royalty etc. Complete as directed by engineer in charge |
| 309 | Sprading, Levelling of Poyta Sandy loam Soil as directed & requirement etc completeWatering & Compacting the Subgrade & Subbase layer (Coarse Sand, Fine Sand & Red soil) with vibratory roller including artificial watering etc. complete. (Top layer of wicket laid in one icnh layer & compacted)Spec. No.:- As directed by Engineer in charge |
| 310 | Source, Supply, Deliver & Plant Bermuda 419 grass on site by Planting method directed by engineer in charge. The grass must be weed fee. Rate including all required fertilizer, pesticider & Chemical etc. complete for growing the turf.Spec. No.:- As directed by Engineer in charge |
| 311 | Providing and laying perforated PVC 110 mm dia pipe in proper line,leveland slope including necessary trenching material fitting etc. complete.Spec. No.:- As directed by Engineer in charge |
| 312 | Design, Supply, Installation, Testing and Commissioning of all Irrigation/sprinkler Systeam as per sprinkler manufacturere specification semi Automatic hunter toru Irrgation system , site conditions requirement, scope of work to make sprinkler systeam operate smoothly as per requirement of the football field and approval by client/consultant, Installation includes preparation of Shop drawings and all other items required for staisfactory performance of sprinkler system but not included in the supply items. (including all material & Labour charges, piping, popup sprinkler with swing joints, all Cableling with condute, Pumps (1 working + 1 standby) min. 10 HP, Automatic Controll Panel, Valves, Disc Filter, Clamps, NRV, Etc all complete to run Smooth Opration of Sprinkler.)Brands:- i)Pipe & Valve:-Harit/Prince/Supreme,iii)SPRINKLERS, AUTOMATION & ACCESSORIES:- Rain Bird ,USA Hunter Toroiv)FILTERATION UNIT:- Azud, eco aqua ,v) Pumps:- Kirloskar/Crompton Greave /KSB/Willow |
| 313 | MAINTENANCE OF Football Field FEILD: After planting the Turf grass, thereafter it will be maintained and manicured up to and including full Growth of Turf and thereafter for 12 Months till the end of Defect liability period. Maintenance includes mowing, irrigation, fertilising, fungicide application, weed management , aeration, maintaining levels, scarifying , irrigation management etc as directed by the consultant .(Provide for NPK , Micro nutrients, Fungicide, Bio organic fertilisers) |
| 314 | Football Goal Post (All As per FIFA Requirement for premier Tournament)Supply and installation of Uprights & Crossbars made from 102mm x 112mm reinforced aluminium with double recess for flush fitting fixings. Reinforced welded aluminium corner joints for improved aesthetics and superior strength, with laser cut internal fixing for exceptionally accurate joints. Injection moulded toughened nylon net clips that won\"t deteriorate over time. Lock-in T-bar to allow for easy storage of the bottom net bar against upright for pitch maintenance. Reinforced net support system prevents bowing under intense tension. New, heavy duty ratchet winch and webbing strap allows for high-class net shape with the inclusion of a failsafe wire providing 100% security during matches. Lock-in bottom net bar 38mm diameter aluminium bar with ground secure key lock mechanism complete with 4 sockets and white Polyester powder coated of size 7.32m x 2.44m Set = 2 Goals with 4 x 460mm deep sockets, and net etc. all complete as per FIFA Specification. Make Freewill |
| 315 | Providing and fixing security chain link fencing around football ground 2.00 meter high vertical post made with MS square hollow section 72x72x4.8mm vertical post & Horizantal pipe of size 50x50x3.6mm MS square hollow section on fixing with chainlink fencing mesh size 2\"\"x2\"\" of 10 gauge hot dip PVC chian link fixed with spilt line/wire for tighting with MS flat 12x5mm. including fixing in position in concrete complete in all respect to the entire satisfaction of engineer-in-charge including carriage of materials within all leads and lifts and other incidantal charges. |
| 316 | supplying and installation of competition equipment as per requirements/ specifications laid down by World Athletics and as per direction of the Engineer-in-charge. Steeplechase hurdle, Shot Put ring, Aluminium kerbing, Pole Vault Box, Hammer cum discuss rings with cage, Take-off boards(Long jump &triple jump). |
| 317 | SYNTHETIC TRACK SUB BASE WORK |
| 318 | SUB HEAD -EARTH WORK |
| 319 | Earth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and lift upto 1.5 m : |
| 320 | All kinds of soil |
| 321 | Earth work in excavation by mechanical means (Hydaulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, for all lift and lead, including getting out the excavated soil and disposal of surplus excavated soils as directed, within all lead and lift. |
| 322 | All kinds of soil. |
| 323 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming , watering, etc. and disposing of surplus excavated soil as directed , within all lead and lift.All kinds of soil |
| 324 | Pipes, cables etc. exceeding 80mm dia. but not exceeding 450 mm dia |
| 325 | SUB HEAD- CONCRETE WORK |
| 326 | Providing and laying in position cement concrete of specified grade including the cost of centring and shuttering - All work upto plinth level |
| 327 | 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 328 | 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 329 | Centering and Shuttering including sturting proping and removal of formwork for |
| 330 | Foundations, footings, bases for columns |
| 331 | Retaining walls, return walls, walls (any thickness) includingattached pilasters, buttresses, plinth and string courses fillets,kerbs and steps etc. |
| 332 | SUB HEAD- BRICK WORK |
| 333 | Maonry work with concrete /cement block or latrite stone work in foundation and plinth in : |
| 334 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 335 | SUB HEAD- FINISHING |
| 336 | 12 mm cement plaster of mix : |
| 337 | 1:4 (1 cement : 4 coarse sand) |
| 338 | Neat cement punning |
| 339 | SUB HEAD- ROAD WORK |
| 340 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres |
| 341 | Supplying and stacking at site : Good Earth |
| 342 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. |
| 343 | With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-30 |
| 344 | Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge. |
| 345 | Providing and applying tack coat using hot straight run bitumen of grade VG - 10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications : |
| 346 | On W.M.M. @ 0.75 kg./sqm. |
| 347 | On bituminious surface @ 0.5 Kg/sqm |
| 348 | Providing and laying bituminous macadam using crushed stone aggregates of specified grading premixed with bituminous binder, transported to site by tippers, laid over a previously prepared surface with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specificatons and directions of Engineer-in-Charge.50 to 100 mm average compacted thickness with bitumen of grade VG-30 @ 3.50% (percentage by weightof total mix) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity. |
| 349 | Providing and laying Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equipped with electronic sensor to the required grade, level and alignment and rolling with smooth-wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per the directions of the Engineer-in-Charge.40/50 mm compacted thickness with bitumen of grade VG-30 @ 5.5% (percentage by weight of total mix)and lime filler @ 3% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity. |
| 350 | Providing and laying of cast in-situ Synthetic Athletic Track Sandwich System (VOC free) with a minimum thickness of 14mm (having a World Athletics approved product certified for minimum 14mm thickness) including markings on the surface as per requirements/ specifications laid down by World Athletics (IAAF) from a firm who should have supplied and installed atleast 5 nos. World Athletics (formerly IAAF) certified 400M Synthetic Athletic Track cast-in-situ Sandwich system in India, with same manufacturer and with same proposed product, including complete sub base, in their individual capacity (and not as joint venture/sub-contract) in the last 7 years from the last day of the previous month of the tender floating date. Manufacturer should be from America/Europe/Australia/India only. Colour of the track: TerracotaNormal Stress Areas. The thickness of finished track surface should not be less than 14 mm.High Stress Areas with a minimum thickness of 20 mm of finished track surface.High Stress Areas with a minimum thickness of 25mm of finished Track Surface.Line marking and World Athletics Class-I certification charges |
| 351 | E.I. WORKRecessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/ legrand( Myrius) / Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.NB:All the electrical,Fire fighting,HVAC,ELV drawings, Technical Data Sheets & make will be approved by SE R& B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work. |
| 352 | Group A |
| 353 | Group B |
| 354 | Group C |
| 355 | Supply and fixing of ISI marked modular type 2nos 6Amp socket with switch on suitable size of metal box and modular cover in front on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/-Schneider(Zencelo)/PANASONIC(VISION) |
| 356 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 357 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover(falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 358 | Supply, delivery, installation, testing and commssioning of modular type TV Antenna Outlet Boards containing a ISI marked Modular TV Antenna/Telephone Socket fixed on Modular Concealed Box including connections and making good the damages caused complete as required and as per Dierction of Engineer-In-Charge. |
| 359 | Supplying and drawing TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated shielded with fine tined copper braid and protected with FR PVC sheath in existing surface / recessed steel / PVC conduit as required as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge. |
| 360 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI/ V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 361 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI/ V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 362 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI/ V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 363 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI/ V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB) (4X6+2X4) |
| 364 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years. |
| 365 | 4 Way(8+(4x3)+(3x4)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years |
| 366 | Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 2P, 415 volts, RCCB 30mA . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year |
| 367 | Supplying and fixing 40 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 year. |
| 368 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year |
| 369 | Fittings & Fixtures |
| 370 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 371 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge.(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years |
| 372 | Supplying an fixing of recess/surface mounted 2\"x2\" 36 W(595mmx595mmx70mm) square shaped LED with lumen efficacy not less than 130lm/W, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 5years. |
| 373 | Supply ,Installation and testing of 15W LED BULK HEAD WALL MOUNTED light with pressure die cast Aluminium housing and high transmitive PMMA diffuser IP 65 (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 2years. |
| 374 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 375 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 376 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.( fan Regulator compatible) |
| 377 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) |
| 378 | MAIN FEEDER PANEL S/I/T&Commissioning of CPRI tested LT outdoor floor mounted cubical type electrical main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.. 80X10MM Separate Aluminium Earth bus bar should be installed. All the feeders shall have ON/OFF/TRIP indication.Provision of 65kA 3P+N type 1+2 SPD alongwith 63A, 4P, MCB, C series, 10kA is to be given in the incomerIncomer:1 800A 4P MCCB(50 KA) with LSIG microprocessor based, Ics=100%Icu Bus bar: 4 nos.900A Aluminum Busbar duly sleeved 1 no. 630A 4way MOTORISED CHANGEOVER SWITCH Outgoing: 3 Nos 250 A 4P MCCB 36 ka with LSIG microprocessor based, Ics=100%Icu , with adjustable thermal setting Ics = 100% of Icu All MCCB should have Ics = 100% of Icu , 1 no.400A 4P MCCB(36 KA) with LSIG microprocessor based, Ics=100%Icu,4 nos. of 125 A 4P MCCB 36 ka with adjustable thermal setting Ics = 100% , 2 nos. 100A 4P MCCB 36 ka with adjustable thermal setting Ics = 100% ,1 NO. 630A 4P MCCB(36 KA) with LSIG microprocessor based, Ics=100%Icu , 1 NO. 320A 4P MCCB(36 KA) with LSIG microprocessor based, Ics=100%Icu Instrument- (i)all the incoming feeders shall have phase indicating lamp with toggle switch & HRC fuse.(ii)All the outgoing feeders shall have digital ammeter with suitable rating of Class 1 CT as per the feeder rating.(Sicure/L&T/ABB/Schneider/Siemens/Legrand)(iii) 1 set of digital multifunction meter(V+A+F+KwH+KVAR+KVAH+THD (Sicure/L&T/ABB/Schneider/Siemens/Legrand)Make of MCCB- LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB FormulaMake of MCB- Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200Make of SPD-LEGRAND/SIEMENS/SCHNEIDER/ABB/OBO/DEHN |
| 379 | MAIN CONTROL Panel (VOLLY COURT,BASKET COURT,LAW TENIS COURT ,GALLERY & SWIMMING POOL,SITE DEVELOPMENT ): S/I/T&Commissioning of LT outdoor floor mounted cubical type electrica panelmade out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.. 40X10MM Separate Aluminium Earth bus bar should be installed. All the feeders shall have ON/OFF/TRIP indication. Incoming: 250 Amp. 4P MCCB 36 ka with LSIG microprocessor based, Ics=100%Icu ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula) .,200A 4P Manual Changeover Busbar : 04 numbers of 300Amps Electrolytic Aluminum busbar duly sleeved by color coaded PVC sleeve & supported by suitable size DMC insulator. .Outgoing: 63 Amp.4P MCCB 25 KA with adjustable thermal setting Ics = 100% -4 Nos , 125 Amp.4P MCCB 25 KA with adjustable thermal setting Ics = 100% -4 Nos , 63A 4P MCB 10 KA, C series-2 nos., 40 4P MCB 10 KA, C series-2 nos ,32 4P MCB 10 KA, C series-2 nos , 32DP MCB 10 KA, C series-4 nos. Instrument- (i)All the incoming feeders shall have phase indicating lamp for R,Y,B inndication with 2A SP MCB,C,10KA. ( Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200)..(ii) 01 set of 3 ph digital type Voltmeter(Make-Siemens/Schneider/ABB/Secure).(iii)01 set of 3 ph digital type Ammeter(0-250)A(Make-Siemens/Schneider/ABB/Secure) with CTs 250/5A 3 nos class 1 type(Make-KAPPA /AE)1 no. 3P+N 40kA type 2 SPD with 63A rating,10KA breaking capacity ,4P MCB conforming to the relevant ISS and as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge.( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula)Make of MCCB- LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB FormulaMake of MCB- Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200Make of SPD-LEGRAND/SIEMENS/SCHNEIDER/ABB/OBO/DEHN |
| 380 | S/I/T&Commissioning of LT Outdoor CPRI tested floor mounted cubical type electrical control panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.. 20X10MM Separate Aluminium Earth bus bar should be installed. All the feeders shall have ON/OFF/TRIP indication.Provision of 40kA 3P+N type 2 SPD alongwith 63A, 4P, MCB, C series, 10kA is to be given in the incomer. Incoming: 125 Amp. 4P MCCB- 25 KA 1 No withTMR based release with adjustable overload ,Icu=100%Ics ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula)., 200 Amp. Electrolytic aluminum Bus Bar - 4 Nos. by color coded PVC sleeve & supported by suitable size DMC insulator. Outgoing: 63 Amp.4P MCCB 16 KA withTMR based release with adjustable overload ,Icu=100%Ics -6 Nos ,40 Amp.4P MCB 10 KA -3 Nos ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula) Instrument- (i)3 numbers phase indicating lamp for R,Y,B inndication with 2A SP MCB,C,10KA. ( Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200)(ii) 01 set of 3 ph digital type Voltmeter(Make-Siemens/Schneider/ABB/Legrand/Secure).(iii)01 set of 3 ph digital type Ammeter(0-200)A(Make-Siemens/Schneider/ABB/Legrand/Secure) with CTs 125/5A 3 nos class 1 type(Make-KAPPA /AE) conforming to the relevant ISS and as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge.( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula)Make of MCCB- LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB FormulaMake of MCB- Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200Make of SPD-LEGRAND/SIEMENS/SCHNEIDER/ABB/OBO/DEHN |
| 381 | Design, Supply, Installation, Testing and Commissioning of Outdoor type with CRCA 2mm thick Main Distribution Boards ( MDB) for operation of the lights incomer, 4P 63A MCCB,16KA, Adjustable thermal and fixed magnetic type, Ics=100%Icu, 100 Amp. Electrolytic aluminum Bus Bar - 4 Nos. by color coded PVC sleeve & supported by suitable size DMC insulator. outgoing 6nos. 32A FP MCB C series,10kA with indication lamps. with one no.40kA type 2 3P+N SPD with 63A 4P MCB, C series, 10kA in the incomer and other accessories as per direction of Eng-in-chargeMake of MCCB- LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB FormulaMake of MCB- Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200Make of SPD-LEGRAND/SIEMENS/SCHNEIDER/ABB/OBO/DEHN |
| 382 | Design, Supply, Installation, Testing and Commissioning of Outdoor type with CRCA 2mm thick Mast Lighting Distribution Boards ( MLDB) for operation of the lights on Stadium masts incomer-32A, FP MCB, C series,10kA , 100 Amp. Electrolytic aluminum Bus Bar - 4 Nos. by color coded PVC sleeve & supported by suitable size DMC insulator and outgoing 10A DP MCB, C series,10kA-16 nos with one no.40kA type 2 3P+N SPD with 63A 4P MCB, C series, 10kA in the incomer and other accessories as per direction of Eng-in-charge.Make of MCCB- LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB FormulaMake of MCB- Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200Make of SPD-LEGRAND/SIEMENS/SCHNEIDER/ABB/OBO/DEHN |
| 383 | HVAC OUTDOOR PANEL:S/I/T&Commissioning of CPRI tested LT outdoor floor mounted cubical type electrical main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. BUILDING HVAC as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.Provision of 40kA 3P+N type 2 SPD alongwith 63A, 4P, MCB, C series, 10kA is to be given in the incomer. 40x10mm Separate Aluminium Earth bus bar should be installed.In commer- 01 number of 320A 3P+N MCCB,25 Ka with under voltage,over voltage ,current,earth fault protection Icu=100%Ics with adjustable Thermal Magnetic Release( Make-LEGRAND DPX3/ Siemens 3VA/ Schneider CVS/ABB FORMULA). Bus bar: 4 nos. 400A CU Busbar duly sleeved Bus bar OUTGOING:7 Nos 63A 4P RCB0. (300 MA),3 NOS.63A 4P MCCB 16KA, Adjustable thermal and fixed magnetic type, Ics=100%Icu Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 1 no. 3P+N 40kA type 2 SPD with 63A rating,10KA breaking capacity ,4P MCB ,01 set of 0-400Amps Ammeter with CTS.(DIGITAL) (Sicure/L&T/ABB/Schneider/Siemens/Legrand)(iii) 01 set of 0-500 voltmeter .(DIGITAL)(Sicure/L&T/ABB/Schneider/Siemens/Legrand)Complete duly factory wired as per SLD and panel should have proper earth by suitable rated Aluminium flat.Make of MCCB- LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB FormulaMake of MCB- Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200Make of SPD-LEGRAND/SIEMENS/SCHNEIDER/ABB/OBO/DEHN |
| 384 | ARENA LIGHTING PANEL:S/I/T&Commissioning of LT outdoor floor mounted cubical type electrica panelmade out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.. 20X10MM Separate Aluminium Earth bus bar should be installed. All the feeders shall have ON/OFF/TRIP indication. Incomer:63 A 4P MCCB (16 KA) with adjustable thermal setting Ics = 100% of Icu, with Undervoltage and overvoltage relay .The UV OV relay should be integrated with MCCB shunt coil. Bus bar: 4 nos. 100 A Al Busbar duly sleeved OUTGOING : ,20 NOS 6 AMP DP MCB, C series 10 KA Instruments: 1 set.LED type phase indicating lamps with control fuse Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 01 set of 0-100Amps Ammeter with CTS.(DIGITAL)(Sicure/L&T/ABB/Schneider/Siemens/Legrand)(iii) 1 no. 3P+N 40kA type 2 SPD with 63A rating,10KA breaking capacity ,4P MCB & 01 set of 0-500 voltmeter .(DIGITAL)((Sicure/L&T/ABB/Schneider/Siemens/Legrand),Complete duly factory wired as per SLD and panel should have proper earth by suitable rated Aluminium flat.Make of MCCB- LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB FormulaMake of MCB- Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200Make of SPD-LEGRAND/ SIEMENS/ SCHNEIDER/ ABB/ OBO/ DEHN |
| 385 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. |
| 386 | 3.5 core x 50 sq mm Aluminium armoured Cable.(FOR MAIN PANEL) |
| 387 | 3.5 core x 300 sq mm Aluminium armoured Cable.(FOR MAIN PANEL) |
| 388 | 4C core 16 sqmm Aluminium armoured Cable |
| 389 | 3.5 core x 120 sq mm Aluminium armoured Cable. |
| 390 | Supply and laying of 3C* 2.5sq mm Copper UnArmored Cable : SITC OF 3 core 2.5 sq mm multistand unarmored cable of fire retardant type with low dielectric losses and higher current carrying capacity, Higher short circuit rating. Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster |
| 391 | Supplying & laying of one number PVC insulated armoured and PVC sheathed XLPE property copper. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 5core x 10 sq mm |
| 392 | Supply and laying of 3 core 2.5 sqmm control cooper armoured Cable (HALL light ). Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster |
| 393 | Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 394 | 3.5 core x 50 sq mm brass double compression gland and aluminium lugs |
| 395 | 3.5 core x300 sq mm gland and aluminium lugs |
| 396 | 3.5 core x 120 sq mm gland and aluminium lugs |
| 397 | 4 core x 16 sq mm gland and aluminium lugs |
| 398 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 399 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 400 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 401 | EARTHING |
| 402 | Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 403 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 404 | Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 405 | Providing and Fixing of 4.5 Kgs. Capacity CO2 gas type ISI marked fire extinguisher (IS: 15683) fitted with high pressure 1 mtr. Long discharge hose & horn complete with refill gas, carrying handle and wall mounting bracket etc as required.Make-Safex/Fireshield/Ceasefire/Flameklog |
| 406 | Providing and fixing 6 kg ABC type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make-Safex/Fireshield/Ceasefire/Flameklog |
| 407 | Supplying, installation, testing and commissioning of 2 kg capacity Eco friendly stored pressure type filled with HFC 236(Clean agent fire extinguisher) having zero ozone depletion potential clean agent fire extinguisher with safety seal, pressure gauge,controlable discharge mechanism helium leak detection tested and confirming to IS 15683 complete with initial charge including cost of all material & labour etc complete.Make-Safex/Fireshield/Ceasefire/Flameklog |
| 408 | CCTV SURVILLENCE SYSTEM |
| 409 | SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit. |
| 410 | SITC of Cat6 I/O with Dual Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit |
| 411 | SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax, Legrand, Panduit |
| 412 | SITC of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit(1 mtr length) |
| 413 | SITC of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit(2 mtr length) |
| 414 | SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Systimax, Legrand, Panduit |
| 415 | SITC of Rack mount Draw Type Loaded 6 port LIU available in Standard 19” ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,Adaptor, SM, Duplex SC, PC Type ,Pigtail, Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR-326-Core . Make: Systimax, Legrand, Panduit |
| 416 | SITC of OFC Patch Cor, SM (OS2), Duplex LC-SC, LC-LC PC Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db. Make: Systimax, Legrand, Panduit |
| 417 | SITC of 1G-LX/LH SFP transceiver module,SMF, 1310nm, 9/125 um Single mode Fiber Type up to 20 KM. Make: Cisco, Digisol, Netgear |
| 418 | SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 370W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V. Make: Digisol, Cisco, HP |
| 419 | SITC of 9U/500D Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make:Valrack, Rittal, Legrand |
| 420 | SITC of 24U 600/650D UL Listed Floor mount Rack with Front perforated door with 3 point lock, Rear mesh door with Cam lock and 3inch Castor Wheel included with 2 no 6/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Length, 4nos 1U Metal Cable manager with Plastic cable loops, 2nos CFM FAN set, 1no Monitor Tray - Ventilation - 495W - 375D and H/W screw920sets). Make:Valrack, Rittal, Legrand |
| 421 | Supply and installation of Dual band 802.11ax WiFi6 Dual Band Access Point. Complying PoE+ for power, with inbuilt on premise virtual controller as well cloud based controlling and administration of WiFi systems All hardware should supplied with necessary mounting brackets and IN power cord with 3 years of comprehensive onsite warranty. Make: Cisco/Digisol/Netgear |
| 422 | Supply ,installation ,testing & commissioning of 5KVA UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sequence corrector of 3ph in put to 3 ph output,415V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 26AH, 20 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric/APC/ Vertiv/) , as per direction of Engg.-in-Charge. Warranty period of all accessories & component & system must be 2 years & complete test certificate must be submitted along with ups including component list & SLD. for services building |
| 423 | Supply ,installation ,testing & commissioning of 20KVA Parallel UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sicuency corrector of 3ph in put to 3 ph output,415V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 65AH, 32 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric / APC/ VERTIV) as per direction of Engg.-in-Charge. Warrentee period of all accessories & component & system must be 2 years & compelete test certificate must be submitted along with ups including component list & SLD. for arena lighting |
| 424 | Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR Fixed Lens Dome/Bullet Camera, 1/2.8\" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, four stream at various resolution & Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 50m(bullet)/40m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 - 1/100,000; Adavance Video Compression technology such as H.265 HEVC/ H.264 / MJPEG , Fixed Lens 2.8mm(Dome)/3.6mm(bullet), Field of View FoV H:96.5°, V:73.8°(dome)/ Field of View FoV H:94.1°, V:71°(bullet), BLC, HLC, WDR, 2D/3DNR, White Balance - Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 & IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130-4), FCC Part 15, EN 55032 & RoHS (EN63000),NDA,STQC compliant. Make-Honeywell Value series/Pelco/Axis/Bosch |
| 425 | Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR motorized Lens Dome/Bullet Camera, 1/2.8\" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, four stream at various resolution & Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 70m(bullet)/50m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 - 1/100,000; Adavance Video Compression technology such as H.265 HEVC/ H.264 / MJPEG , Fixed Lens 2.7-13.5mm motorized, Field of View FoV H:100-28.5°, V:73-21.4°, BLC, HLC, WDR, 2D/3DNR, White Balance - Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 & IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130-4), FCC Part 15, EN 55032 & RoHS (EN63000),NDA,STQC compliant. Make-Honeywell value series/Pelco/Axis/Bosch |
| 426 | Supply , Installation, testing , commissioning of 64 Channel NVR with 8 SATA; 384 Mbps incoming bandwidth, Up to 8 Megapixels Resolution Display and Recording, H.265 video compression technology with real time encoding, Full function CMS (Central monitoring software) supported, Two way audio supported, Dual streaming technology to encode recording stream and network stream separately, Supports remote monitoring on Mobile Client (Android, IOS), TCP / IP, PPPoE, DHCP, DNS, DDNS, UPnP, NTP, SMTP, Time/ Date, Alarm, Motion Detection & Exact Search (accurate to second), Record Snapshot, FTP, Preset Calling, Email notification supported, Manual/ Alarm/ Motion Detection/ Continuous, CE, FCC, RoHS).Make-Honeywell value series /Pelco/Axis/Bosch |
| 427 | Supply, Installation,Testing & Commisioning of Surveliance 10 TB HDDMake:- WD/Segate/Toshiba |
| 428 | SITC of 55\" UHD IPS Commercial Digital Display for Small Size Discussion & Chambers: Brightness (440 nits or higher), Dynamic Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static (Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms, Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C Broadcasting System, Commercial Smart UX, webOS version (webOS 6.0), BIS Certification with 3 years onsite warrenty. Make: LG/Samsung/Sony |
| 429 | (2 VOLLYBALL COURT,BASKETBALL & LOWTENNIS COURT) |
| 430 | Supply of 9 mtr long hot dip galvanized Octagonal pole with channel bracket (for mounting at least 6nos. or more of flood light as per final lux level design) manufactured from HT steel having base dia if 210 mm & top dia 90 mm or more and sheet thickness of 4 mm or more and 4 Nos. M30X850mm EN8 Grade foundation bolt. The octagonal pole shall be suitable to withstand 200 KM/HR or more wind speed by considering the weight & wind expose area . All accessories included like anchor plate, foundation nuts & bolts including required size of control cable from starter panel to each light . Make:- Bajaj/RR Ispat/Utkarsh /Vakrangee/Valmont |
| 431 | Construction of pedestal type foundation with M20 grade concrete for pole 2000mm depth x 550mm length x 550mm breadth including all material and labour as per the direction of Engineer-in-charge. The structural calculation and civil foundation shall be duly approved by the competant authority from civil wing before execution of the work. |
| 432 | SITC of high-quality integrated LED Flood Light with a minimum system lumen of 37.5K Lm or higher and nominal efficacy of 125 lumen/watt or higher. CCT of 5700K with SDCM of < 5 and CRI >=80. The housing should be of pressure die-cast aluminum (ADC12) to with stand extreme environments. The luminaire should come with with PF > 0.95, THD<10%, Lifetime of 50K hours @L70. Product should be suitable for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP 66 with an IK rating of 08. Optical and control gear compartments shall be maintainable/replaceable without impacting the LED units. The access to the optical and the gear compartment should be separate. While accessing the gear compartment, the optical compartment should not be accessible. The Luminaire should have internal surge protection of 4kv and 10 KV /10 KA SPD duly bolted in the Luminaire . The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2.The luminaire should be of Class B Serviceability. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Multi Chip , array multi die , mid power ,Integrated arrays and COB’s are not permitted. The High power LED used in the luminaire shall be SMD type. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. The Drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire. The fixture shall have warranty of 5 years. LM79,LM80,Type test report, BIS certificate of driver and luminaire, TDS of luminaire and driver,LUX level design to be done as per following specifications: average lighting level shall be >=600 LUX ,min to average shall be >=0.7, min to max shall be >=0.5 and shall be approved by SEEC(R&B) and CE,Bdgs,O,BBSR before final procurement.Make- Panasonic/Philips/Bajaj/LT/Wipro/Crompton/Havells |
| 433 | Supply & Installation of AVIATION LIGHT as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge |
| 434 | INDOOR HALL |
| 435 | SITC of single die-cast housing (modular type is not allowed) LED Flood Light with a minimum system lumen output of 48K lm or higher and nominal efficacy of 120 lumen/watt or higher. CCT of 5700K with SDCM of < 5 and CRI >= 80. The housing should be of non-corrosive high-pressure die-cast aluminum (ADC12) to with stand extreme environments. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. with PF > 0.95, THD<10%. Lifetime of 75K hours @L70. Product should be suitable for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP 66 with an IK rating of 08. Optical and control gear compartments shall be maintainable/replaceable without impacting the LED units. The access to the optical and the gear compartment should be separate. While accessing the gear compartment, the optical compartment should not be accessible. The Luminaire should have n internal surge protection of 4kv and 20 KV /10 KA SPD duly bolted in the Luminaire . The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. .The luminaire should be of Class B Serviceability. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Multi Chip , array multi die , mid power ,Integrated arrays and COB’s are not permitted. The High power LED used in the luminaire shall be SMD type. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. The Drivers should be a potted driver not a printed circuit board without casing, mounted outside the luminaire in a separate driver box placed near the high mast. The driver control panel box should be outdoor type and shall be forced ventilated with industrial grade outdoor fans with working and standby. The fixture shall have warranty of 5 years. LM79,LM80,Type test report, BIS certificate of driver and luminaire, TDS of luminaire and driver, LUX level design to be done as per following specifications: average lighting level shall be >=1000 LUX ,min to average shall be >=0.7, min to max shall be >=0.5 and shall be approved by SEEC(R&B) and CE,Bdgs,O,BBSR before final procurement.Make-Panasonic/Philips/Bajaj/LT/Wipro/Crompton/Havells |
| 436 | HVAC WORK |
| 437 | Outdoor Units |
| 438 | Supply,Installation, Testing and Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling only, having all hermetically sealed inverter type Scroll/Twin rotary Compressor(s) microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. The unit shall deliver the rated capacity at AHRI Conditions and work even at 49°C ambient temperature without tripping. The unit shall be suitable to work on 380-415 V, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. MS/GI powder coated stand with vibration isolation pads.The ODU shall have low noise condenser fans with external static pressure of the outdoor unit shall be more then 75 Pa to avoid hot air recirculation, auto address setting, automatic refrigerant charging,auto check function for connection error and complete with indoor and outdoor units with individual controller and with fittings etc. .The Unit should have free phase technology so that unit can work in case of phase reversal also without tripping of units.ISEER should be greater than equal to 7.4 for cooling capacity less than 40kWr, ISEER should be greater than equal to 7.5 for cooling capacity more than equal to 40kWr and less than 70kWr and ISEER should be greater than equal to 7.6 for cooling capacity more than equal to 70kWr.The deration chart of outdoor from factory head should be submitted before procurement.Make: Mitshubishi/ TRANE/O-GENERAL/Diakin |
| 439 | SITC of ODU Connecting Kit with other accessories as per the direction of Engineer-in-charge. .Make: Mitshubishi/ TRANE/O-GENERAL/Diakin |
| 440 | SITC of AHU connecting kit with other accessories as per the direction of Engineer-in-charge. .Make: Mitshubishi/ TRANE/O-GENERAL/Diakin |
| 441 | The performance of air handling units should be tested in a Eurovent-accredited laboratory.The AHU technical data sheet shall be submitted for coil/fan performance from certified software output individual component selection not be considered.One AHU for the project will be factory tested for air performance CFM / Static / Power / Motor KW / Sound/Vibration, prior to dispatch.Air handling unit shall be selected for the lowest operating noise level i.e. not exceeding 65 dbA @ 1.5 metre distance from the equipment. Mechanical Characteristics as per EN 1886: a. Casing Strength Classification: D1 b. Casing Air Leakage: L1 c. Filter Bypass Leakage: F9 d. Thermal Transmittance: T2 e. Thermal Bridging Factor: TB2 Air Handling Unit Performance as per EN 13053.Supply, installation, testing ,assembly at site and commissioning of outdoor type DOUBLE SKIN FLOOR MOUNTED AHU of horizontal / vertical arrangement, draw through type with sectionalised construction suitable to be assembled at site as per EN 1886 Construction Details: Double-skinned panels shall be 50 ± 2 mm thick with thermal break construction and made of galvanized steel skins, pressure injected with PU foam insulation having density 40 kg/m3 with a K factor not exceeding 0.022 Watt/Mc internal structural framework with high speed steel screws. Outer sheet of panels shall be made of pre-painted, of 0.8 mm thick, and inner sheet of 0.6 mm G.I. Sheet.The entire framework shall be assembled in modules & mounted on a galvanized steel (depending on size) channel base as per manufacturer’s recommendation. All panels to have doors except for the coil section & to be openable on the outside.Drain pand shall be strictly inside the AHU casing PU panel and not to be exposed to environment. |
| 442 | Mixing Section: The AHU shall be provided with mixing chamber section. The mixing box shall have a manually operated return air and fresh air damper of Low leakage Aerofoil design, with concealed (Nylon gears / linkage type) Anodized Aluminum construction in the mouth piecePre Filter Section:The AHU shall be provided with synthetic (non woven) filter section with 50 mm thick filters fitted on aluminium frame capable of filtering 90% down to 10 micron (MERV-8) washable type filters as per EN 779Note: The AHUs should be supplied with a pair of pre-commissioning filters which will be replaced by the actual filters during commissioningFine Filter Section:The AHU shall be provided Fine filter section containing Synthetic 300 mm Bag, class F7, equivalent to EU7 (MERV 13) of ASHRAE 52.2 1999 .The efficiency of the filters shall be 95% down to particle size of 5 microns as per EN 779. Differential pressure measuring port to check filter efficiency all complete as requiredCoil Section: Cooling coil of 6 row copper tube. The coil shall be EUOROVENT certified as per EN 1216. The header shall be made of copper and the end caps of MS. The tube shall be of copper and shall be 0.4 mm thick and 12.5 mm diameter. The fins shall be of aluminium of 0.11 mm thickness with spacing of 10-11 FPI and shall be coated with anticorrosive hydrophilic blue colour coating. The coil shall be minimum 6 row deep or shall be designed as per the load requirement and the area shall be selected for a maximum face velocity of 2.5 m/s. (Selection sheets need to be provided for approval)Fan Section: Eurovent certified direct driven aerofoil design blade plug fans of high efficiency as per EN 5801. The fan shall be selected for an outlet velocity of not more than 9 m/s. The fan should be selected to ensure that it operates within the optimum range when the speed of fan shalll be 40% to 150% of motor RPM. For capacities till 9000 cfm single fan can be used. For capacities between 9000 cfm to 14000 cfm single / two fans can be used. However for capacities above 14000 cfm, multiple fans to be used.Motor Section: The AHU shall be provided with AC motors of high efficiency. Motor shall be 415±10% volts, single / three phase as suiting the airflow range, TEFC, with class F insulation with IP 55 protection for AC Motors. Motors shall be specially designed for quiet operation. The motor should be variable speed type & driven by VFD for AC motors.Motor Winding shall be VPI coated.Drain Assembly: 20G SS 304 drain pan to be installed strictly inside the AHU. Drain pan installation outside the PU panel casing is not allowed. Air moving capacity, cooling capacity and external static pressure ESP) excluding pressure drop across filter, coil and fan sections shall be according to the enclosed AHU details.The rate is inclusive of VFD panel.IP 20 rated VFD to be placed inside the starter panel with IP-55 enclosure.Each VFD panel to be provided with digital display showing electrical parameters like voltage, current and power consumption.At the time of odering ahu total pressure loss as per friction method and ahu coil selection should be submitted for approval. Return air temp.- 25 deg cel,RH-60%, OFF coil temp.-12 deg cel., RH-95%Make- VTS/Trane/Systemair |
| 443 | 48TR 15000 CFM 6RD, ESP-80MM, FM AHU with Pre and fine filter. |
| 444 | SITC of 24ft length x24ft width x 15ft height GI shed for AHU as per direction of Engineer-in-charge. |
| 445 | Refrigerant Piping |
| 446 | Supply & Installation of interconnecting following sizes of refrigerant copper pipe work of following outer diameter, insulated with 25mm thick closed cell electrometric Nitrile rubber tubular insulation between each set of indoor & outdoor units . All external piping(which are exposed to external environment such as terrace etc.) shall be provided with factory laminated GC Cloth & wrapped with 0.6mm thick aluminium cladding & then shall run in perporated hot dip galvanized GI. cable tray with cover etc. as reqd. Make of insulation-K Flex/Armacell/Vidoflex/Eurobatex/Isoline Make of pipe-Rajco/Mandev |
| 447 | 34.9 mm with 1.21 mm thick |
| 448 | 15.9 mm with 1.00 mm thick |
| 449 | Drain Piping |
| 450 | Providing & fixing of PVC Pipe complete with fittings, supports as per specifications and duly insulated with 9 mm thickness Class O of closed cell nitrile rubber/XLPE as per direction of Engineer-in-charge & specifications enclosed as reqd. |
| 451 | 50 mm dia |
| 452 | Control & Transmission Wiring |
| 453 | Providing & fixing control cum transmission wiring of 2 core x 1.0 sqmm shielded copper cable in suitable conduits between indoor and out door unit. Make-Polycab/KEI/Finolex/RR Kabel/Gloster/Havells/V-Guard |
| 454 | Gas Charging for the entire circuit(R410A) |
| 455 | Air Distribution |
| 456 | Supply, Manufacturing, fixing,testing and commisioning of Factory Made double wall Flat Oval Spiral Duct with 19 mm Plain Nitrile rubber insulation of class 1 Sandwich in the both layer .The cost of Insulation shall be included in the ducting Cost with adhasive and all necessary accessores. The Inner layer of the Duct shall be of 24 G only Outer layer shall be as per Ducting SMACNA standards of Flat Ovel Duct . The Cost of Hanging arrangemnet shall be included as per OEM standards and also the GI Hook or clam shall be used . all nut Bolt shall be of Hot Dipped Galvanized GI nut with washer shall be Used . The Cost of Threaded Rod and Necessary fastner shall be included in the Cost of Ducting Its Self .The Duct Shall be Joint with the POP up rivit or Self Fasting GI screw with Sealent . the Length of Duct Shall be either 4 , 10 or 12 Feet . Branch Peices can be as per the Site Design Requirment . The Duct Collar Can be of Single layer with Insulation to acomodate the Air Distribution Product MakeTATA/SAIL/JINDAL |
| 457 | 22 GAUGE (0.80 mm thickness) |
| 458 | 24 GAUGE (0.63 mm thickness) |
| 459 | Insulation work |
| 460 | Supply,installation,testing and commissioning of duct thermal insulation of Following Capacities , Make of insulation-K Flex/Armacell/Vidoflex/Eurobatex/Isoline . - with 25mm thick Nitrile Rubber with factory laminated GC CLOTH to provide the sufficient mechanical protection. The fibre glasscloth shall be factory laminated. The adhesive shall be SR 98 or equivalent sourced from OEM of nitrile rubber insulation. |
| 461 | Supply ,& Fixing of antimicrobial Acoustic Insulation 15 mm thick of open cell nitrile rubber(180 kg/m3).Make of insulation-K Flex/Armacell/Vidoflex/Eurobatex/Isoline |
| 462 | Supply and fixing of Flexible weather proof PVC canvas connection |
| 463 | Supply, erection, testing & commissioning of Aluminium powder coated grills/diffuser with VCD having flange all around.Make-Glenstorm/Airflow/Systemaire |
| 464 | Supply, erection, testing & commissioning of Aluminium powder coated grills/diffuser without VCD having flange all around.Make-Glenstorm/Airflow/Systemaire |
| 465 | Supplying,fixing of hot dip galvanized GI perforated cable trays with cover having horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 450mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 466 | SITC of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc., Make-systemair/ventech/Air master/Ruskin Titus |
| 467 | SITC of Fusible link mechanical fire damper complete with sleeve for fixing on retrun air opening.The damper shall be spring loaded and suitable for reset to original position.The damper also be provided with limit switch for transferring the signal to AHU starter panel/BMS for tripping the AHU in case of fire .The rate shall be inclusive of control wiring upto the Starter panel/DDC clopsing the opening surrounded by the sleeve with fire glass and fire sealant as per standards Fire Damper. Make-systemair/ventech/Air master/Ruskin Titus |
| 468 | Supply & Installation of underdeck insulation of specified thickness of elastomeric rubber insulation manufacted as per ASTM E 84 Test and which should also meet NFPA 90A supplementary materials for air distribution which should not absorb less 0.2% water byvolume (ASTM c 209) should not support microbial growth( ASTM c1071, G21,G22) and should emit obejectionable odors ASTM c665 and should have thermal conductivity of 0.27 (R-2.78 in 3.4\" thickness) and water vapor permeance of 0.1. joints should be sealed with 50mm wide 3 mm thick self adhesive tape ( black cotton tape not acceptable) with all necessary support and structure as per the direction of Engineer-in-charge.Class \"O\" material32 mm thick |
| 469 | Scafolding with all necessary supports for HVAC works and fixing of arena lighting work as per the direction of Engineer-in-charge. |
| 470 | SOLAR STRRET LIGHT |
| 471 | Supply of Elegant look 60 W AIO hybrid LED Solar Street lights having extruded alluminium housing, 180Wp or more (subjected to final panel backup calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) Mono Crystalline Panel/Laminates fixed on the top of the luminaire housing, maintenance free 12.8 volts 78 Ah or more (subjected to final battery calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) LiFePO4 battery(BIS certified) , BMS, MPPT charge controller, PIR sensor( when there will be no movement the lumens output will be 30% output).The solar panel and battery should be designed to provide 2 days (24 hrs ) back up . The luminaire is having IP 65 protection for critical components, IK 08 and having lumen output of >=10000 lumens and having lumen efficacy not less than equal to160 lm/w) as per LM 79 report third party/central/state govt accredited NABL lab to justify the lumen output & lumen efficacy . Lenses should be provided on the LED chip for better lighting dstribution to avoid glare on human eyes. Both the luminaire and Mono Crystalline Panel must be manufactured in India. The Solar lighting company must submit the third party central/state govt accredited NABL lab reports to justify the lumen efficacy,luminaire output , IK 08 and IP 65 protection.The Luminaire should be supplied along with adjustable type mounting bracket which can be fitted directly on the pole.The Solar lighting manufacturer must submit the declaration letter by mentioning that complete solar light and the solar panel are manufactured in India and warranty certificate on their company\"s letterhead by mentioning warranty period as 5 years and necessary aftersales Service will be provided through their tollfree base service network located within 100 KM from the project site. The Solar Street light manufacturer should have own NABL accredieted laborotory. The following test reports must be submitted and approved from SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR for the technical acceptance of the products.1.LM 79 REPORT and LM 80 Report ( from third party/central/state govt accredited NABL lab of AIO solar light) , 2. IK 08 ( from third party/central/state govt accredited NABL lab of AIO solar light ) , 3. IP 65 (Report of third party/central/state govt accredited NABL lab of AIO solar light 4. EN50530 – MPPT Efficiency , 5. IEC61547 , 6. IEC61000-3-2 – EMC , 7. IEC 60598-2-3 ,8. IEC 62109-1, ( The necessary test reports of third party/central/state govt accredited NABL lab from sl no. 4 to sl no.8 must be submitted for any wattage of AIO solar light )Make-(Philips/Panasonict/Wipro/Crompton/Bajaj/Havells/LT). NB: The cost includes 5 years CMC including repair/ Maintenance/ replacement of the product in case of any defect. |
| 472 | Supply of 6 mtr long hot dip galvanized Octagonal pole having base dia of 155 mm and top dia of 70 mm and plate thick ness of 4 mm or more. complete with base plate 260x260x16 mm and 4 nos. Jtype En 8 grade foundation bolts (M24X750 mm) to withstand 180 KM / HR or more wind speed considering the weight & dimension of 1 nos 60 W AIO Solar light to be fitted in the top of the pole .The bidder shall also furnish wind load test report of the solar fixture and wind load test of the pole considering the weight and dimension of 1 no 60 W AIO Solar light to be fitted in the pole to sustain wind speed of 180km/hr or more from third party /central/state govt accredited NABL lab after award of the work.The reports shall be vetted and approved by concerned civil division/circle.(Make - Bajaj/RR ispat//Valmont/Vakrangee/Utkarsh) |
| 473 | Construction of RCC foundation by using M20 grade RCC and Fe415 grade reinforcement in the foundation by considering the SBC as 10 T per sq mtr and fixing 4 nos. EN8 grade foundation bolts in that foundation & installation of pole with solar light on that foundation using suitable machinery.The work shall be executed as per the instruction of EIC . The structural calculation and civil foundation shall be duly approved by the competant authority from civil wing before execution of the work. |
| 474 | Installation of 6 mtr pole on the foundation after fixing the 60 W AIO Light in the pole by using suitable machinery by taking all safety precautions as per the direction of EIC. |
| 475 | STREET LIGHT: S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 63A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 63 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type-II SPD 40ka ,,04 nos 10A 4P MCB,C,10KA as outgoing MCB legrand dx3/ schneider acti9 A9N/ Siemens betaguard/ ABB ( SB 200) as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 1 years of acceptance of materials |
| 476 | SIGNAGES:-Providing and installing in position the following type of sign boards made out of 3mm thick flexyle photoluminescent based glow in dark sheeting with luminous properties enclosed in a weather proof Uvstabilized film with UV screen printing by imported links pasted over3 mm thick cast acrylic from front side with 6 mm thick acrylic, -20 to+80 deg C, Suitablefor indoor use, greenish yellow, glow visible upto 4-6 hr in total darkness.Make-Prolite/Bajaj |
| 477 | Supply delivery ,installation andcommissioning of LED Sign Board as per below specification of Box type Display Matter:-1-BYASANAGAR SPORTS COMPLEX, JAJPUR (English Letter Red Color) Letter Height 36 Inch.2- (Odiya Letter Red Color) Letter Height 36 Inch3-Government of Odisha Logo (36X36 Inch) ACP Sheet:- Aluminum composite panel sheet(ACP) Outdoor type 3 mm (Viva, Alomax, Imperia Décor, Citi Bond ) Supporting of English Letter.Plastics Sheet: - 3mm Plastics Sheet (Yellow, Red) Color & Raising of 2.5 inch.(Gray) (Acast)L.E.D :- 0.3 to 1.5 Watts (Yellow, Red) Color (Samsung, GE, Osaram, Philips, LG) Power Supply: - SMPS (Switch mode Power Supply), RPS (Regulate Power Supply).In put Voltage 160 to 230 A.C./ Out put Voltage 12/24 Volts D.C. (Samsung, GE, Osaram, Philipes, LG). The panel should be supplied with astronomical timer and contactor for auto ON/OFF . The panel should be supplied with overvoltage and undervoltage relay with 20 kA TYPE 2 SPD.The panel should be outdoor type. The letter structure to be installed on the top of the building. It shall withstand 200 km/hr wind velocity, MS ANGLE with primer and paint as per need for sustainable fixture 2 inch Ms pipe fastened with concerte. The cost is inclusive of all the structures, LED light, timer control panel and all other accessories. Make-Cosign/Sign media |
| 478 | P.H. WORKSupplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge.Ground Floor25mm dia PVC ASTM pipe (sch-80) |
| 479 | 32mm dia PVC ASTM pipe (sch-80) |
| 480 | 40mm dia PVC ASTM pipe (sch-80) |
| 481 | First Floor-40mm dia PVC ASTM pipe (sch-80) |
| 482 | 50 mm dia PVC ASTM pipe (sch-80) |
| 483 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor CPVC pipes conforming to IS:15778 having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00. spacing. This includes Jointing of pipes & fittings with one step CPVC solvent cement and testing of Joints all complete as per specification and direction of the Engineer in charge.Ground Floor20mm dia CPVC pipe |
| 484 | 25mm dia CPVC pipe |
| 485 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.250mm thick wall Ground Floor |
| 486 | Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing GI pipes / PVC pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4) including finishing complete so as to make it leak proof as per direction of the Engineer in charge.Ground Floor |
| 487 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/ PVC pipes and making good the damages as per the direction of the Engineer in charge.Ground Floor |
| 488 | Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge. 15 mm dia 2 WAY BIB COCK WITH WALL FLANGE (FLR-CHR-5041N Jaquar Make) |
| 489 | 15mm dia CP Long body bib cock(Jaquar)CON-CHR-107KN |
| 490 | 15mm dia CP Health Faucet (ALD-CHR- 577) |
| 491 | 15 mm dia CP WALL MIXER NON TELEPHONIC ( FLR-MCH-5219N Jaquar make ) |
| 492 | 15mm dia CP ANGULAR STOP COCK WITH WALL FLANGE (FLR-MCH-5053N Jaquar Make ) |
| 493 | 20mm dia CP CONCEALED STOP COCK EXT HVY WTH WITH FLANGE(FLR-MCH-5083NJaquar) Make |
| 494 | 32mm dia CP Bottle trap (Jaquar make)-ALD -CHR-769L -300x190cm |
| 495 | Auto closing concealed urinal flush valve(Jaquar make)-PRS-CHR-077 |
| 496 | 15 mm dia CP pillar cock auto closing system(Jaquar)-PRS-CHR-031 |
| 497 | Soap Dispenser with glass bottle(ACN-CHR-1135N) |
| 498 | CP soap Dish holder (Jaquar make)-AKP -ABR-35731P |
| 499 | Towel Ring Round - (As Per Jaquar,Cat no.:ACN-CHR-1121BN) |
| 500 | 600mm long CP towel rail(Jaquar)-ACN-IVY-1111NM |
| 501 | 25mm dia brass or gun metal fullway valve (Shakti Make) |
| 502 | 32mm dia brass or gun metal fullway valve (Shakti Make) |
| 503 | 50mm dia brass or gun metal fullway valve (Shakti Make) |
| 504 | 15mm dia CP flange |
| 505 | 15mm dia CP extension piece |
| 506 | Supplying all materials, labour, T&P and fitting and fixing CP shower with 15mm or 20mm inlet with CP shower arm including polishing all complete as per specification and direction of the Engineer in charge.15mm dia CP revolving shower With shower arm(Jaquar)OHS-CHR-1985+SHA-CHR-477 |
| 507 | Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge 10 litres capacity pvc low level cistern with 32mm dia CP long flush bend Slimline white (Hindware / Parryware Make) |
| 508 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge In ground floor110mm dia U-PVC SWR pipe (Ashirbad /Sentinity/Supreeme) |
| 509 | 110mm U-PVC door tee |
| 510 | 110mm U-PVC Plain tee |
| 511 | 110mm U-PVC door bend |
| 512 | 110mm U-PVC plain bend |
| 513 | 110mm dia U-PVC \"P\" trap |
| 514 | 110mm dia U-PVC Plain Shoe Bend |
| 515 | 110mm dia U-PVC offset with out ear |
| 516 | 110mm dia U-PVC cowl |
| 517 | 125mm dia CP grating |
| 518 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge. 250mm to 375mm thick wall. |
| 519 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral ‘P’or ‘S’ trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge. European water closet with ‘S’ trap plain with seat cover (Parryware/Hendware/Cera/Somany/Kerovit) |
| 520 | One piece commod(Hindware)ELEMENT Cat No.92084. |
| 521 | Matrix Set -1 (WB 65 x 35 with one pair mounting brackets, EWC & Cistern complete with fittings & seat cover, one no hinged rail 76 cm and five nos of grab rails 60 cm) (head)70002 |
| 522 | Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps conforming to IS:2556-part-4-2004 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore(Plaza make), fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste(Plaza make), etc all complete as per specification and direction of the Engineer in chargeHalf pedestal Basin(Hindware)No.91049+91115 |
| 523 | Under Counter Basin (560x455) (H)10095 white |
| 524 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge. Design mirror |
| 525 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royality, taxes etc all complete as aper specification and direction of the E.I.C. |
| 526 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. |
| 527 | Ground Floor |
| 528 | Supplying all materials, labour, T&P and providing ceramic tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. Kajaria / Somany / Johnson to be pre-approved 600 x 600mm of size. |
| 529 | Ground Floor |
| 530 | Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. Kajaria / Somany 600x 300 size. |
| 531 | Ground Floor |
| 532 | Supplying all materials, labour, T&P and providing brick work with Fly Ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:3) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge,In Superstructure . |
| 533 | Ground Floor |
| 534 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 535 | In Ground floor |
| 536 | Supplying all materials, labour, T&P and providing cement concrete (1:1½:3) with 12mm size crusher broken hard black granite chips for RCC works including hoisting, laying, watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per PWD specification and direction of the Engineer in charge. |
| 537 | Supplying all materials, labour, T&P and providing steel reinforcement of Fe-415 /Fe-500 grade for RCC work including cutting,bending,binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge,cost of steel, conveyance of all materials to worksite, payment of royalty,all taxes etc all complete as per PWD specification and direction of the Engineer-in-charge. 0.80 qntl/ cum |
| 538 | Supplying all materials, labour, T&P and fixing granite tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. |
| 539 | Supplying all materials, labour, T&P and providing distempering 2 coats to walls with distemper of approved shade on new work to give an even shade etc all complete as per specification and direction of the Engineer in charge. |
| 540 | Finishing wall surface of walls with Acrylic wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T&P etc complete. |
| 541 | Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre\"s standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I (ISI marked) size 100mm are to be fitted on one side of shutter. |
| 542 | Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge |
| 543 | Sinking of 200mmx150mm dia large Tube well(1 No.) |
| 544 | Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation(G.I/P.V.C/M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore. |
| 545 | Labour for Drilling of 200 mm dia bore 0mtr to 120mtr |
| 546 | Labour for Drilling of 150 mm dia bore 0mtr to 120mtr |
| 547 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials. |
| 548 | Lowering of 200 mm dia GI/P.V.C/MS casing pipes 0 mtr to 30 mtrs |
| 549 | Lowering of 200mm dia GI/P.V.C/MS casing pipes 31 mtr to 45 mtrs |
| 550 | Cost of 200 mm dia ASTM-D-1785/89 P.V.C schedule-80 pipe |
| 551 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge |
| 552 | By DTH |
| 553 | Supplying all materials and labour,tools and plant and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5 mtrs below ground level(as per drawing)to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock the bottom to ensure sanitary sealing(excluding cost of cement which willbe supplied by the Department). |
| 554 | Submerssible Pump Set 1 H.P three phase 3 stage head range 30 to 54 metres, discharge 155 to 6110 L.M.P with outlet dia of 32 mm. |
| 555 | DOL control panel |
| 556 | 2.50 sqmm cable |
| 557 | 32mm dia steel short piece |
| 558 | 32 mm dia HDPE Pipe |
| 559 | Bore Cap |
| 560 | C.I.Bracket |
| 561 | Rope Wire |
| 562 | Labour charges for lowering of submesible pumpset with pipes and cables etc. with testing and commissioning at site. |
| 563 | Supply all materials,labours,T&P and construction bore well protection chamber of the inside size 650x650x1000 height with cement concrete ( 1;3;6) using 40 mm size hard granite metal on foundation,1st class fly ash brickwork incement motar(1:3),with base cement concrete (1:2:4) useing 12 mm size h.g chips ,12 mm thick cement plaster (1:4) inside and out site ,R CC cover slab in (1:1.5:3) using 12 mm size h.g chips earthwork in excavation in all kinds of soil and refiling the cavity around the chamber including watering ,curing,convayance of all materials to worksite,payment of royalty,taxes etc all complete as per approved specification and direction of the engineer-in -charge. Bore well protection chamber. |
| 564 | Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 80 PSS UV of size 750x570x1350mm height with water storage capacity 80 liters along with 2 nos of faucets 1 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all complete as per approved drawing,specification and direction of the Engineer in charge. |
| 565 | EXTERNAL P.H. WORK Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. 110mm dia U-PVC Alround Concrete |
| 566 | 160mm dia U-PVC Alround Concrete |
| 567 | Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge.Inside size 250mmx250mm |
| 568 | Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 760mmx760mmx460mm . |
| 569 | ---- do --- addl depth of 0.15m upto 0.90m |
| 570 | R.C.P.C.Manhole Cover |
| 571 | Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 910mmx910mmx910mm |
| 572 | R.C.P.C.Manhole Cover |
| 573 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.1.40m dia x 2.00m deep soakway pit. |
| 574 | Construction of 20000 Liters RCC Over head Tank of Inside size- 6.00 X 3.00X1.50m at 1st Floor. 1Nos |
| 575 | Supplying all materials, labour, T&P and providing cement concrete (1:1½:3)with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. |
| 576 | Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage. |
| 577 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete. RCC floor roof, chajja etc. |
| 578 | RCC Beam, Column, wall etc |
| 579 | Supplying all materials, labour,T&P and providing 6mm thick cement plasster (1:4) over CC work including watering curring and conveyance of all materials to site. |
| 580 | For 1nos. Tank |
| 581 | Supplying and fitting and fixing stainless steel 34 grade in said rail using 5mm dia 2mm thick circular pipe and lalustrade 32mmx32mmx2mm at the rate of mtr.Center to center and square pipe 32x32x2mm below including welding with stanless steel elect rod and fixing with necessary accessories etc.complete as per direction of the Engineer-in-charge.For 1nos. Tank |
| 582 | Providing fitting and fixing MS cover made out of MS angle and sheet duly welding and fixing with frame and hinges along with locking arrangement of size 60cmx60cm etc complete as per direction of Engineer-in-charge.For 1nos. Tank |
| 583 | Construction 1 nos 100 users RCC Septic tank |
| 584 | Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge. |
| 585 | - do - with addl. Depth of 1.5 m |
| 586 | Excavation of foundation in laterite rock or any hard rock (other than granite or disintegrated rock) removed by chiselling including dressing and levelling the bed not exceeding 1.50 mtr. in depth and depositing the soil within initial lead of 50 mtr. and as per specification approved by the Department. |
| 587 | Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge |
| 588 | Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. |
| 589 | Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge |
| 590 | Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 591 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 592 | For Roof slab |
| 593 | For RCC wall |
| 594 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 595 | Supplying all materials,labour,T&P and providing 6mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 596 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. |
| 597 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
| 598 | Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge. |
| 599 | Dewatering with 5 H.P diesel engine pump during excavation |
| 600 | Supplying all materials, labour, T&P and providing, fitting and fixing U-PVC SWR Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in charge160mm U-PVC plain Tee |
| 601 | Supplying all materials, labour, T&P and constructing vent base as per P.H.D specification etc all complete. |
| 602 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer\"s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. |
| 603 | 110mm diameter U-PVC SWR pipes(Supreme/Ashirvad) |
| 604 | 110mm U-PVC cowl |
| 605 | Construction of 75000 Litres RCC Underground Reservoir of Inside size- 7.00 X 3.50 X2.30m |
| 606 | Earth work in All kinds of soil and gravels mixed with stone and boulder not exceeding 0.014 Cum in volume within 50m initiallead and 1.5 m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per specification approved by the Department. |
| 607 | -do- with Ist additional depth of 1.50 m over the initial lead and lift |
| 608 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge. |
| 609 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 610 | Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-25 (minimum cement content not less than 403 Kg/Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance, taxes, loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge but excluding the cost of steel reinforcement and shuttering. |
| 611 | Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage. |
| 612 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in ground floor. |
| 613 | RCC floor roof, chajja etc |
| 614 | RCC Beam, Column, wall etc |
| 615 | RCC Plinth bend/ Raft |
| 616 | Supplying all materials, labour,T&P and providing 6mm thick cement plasster (1:4) over CC work including watering curring and conveyance of all materials to site. |
| 617 | Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site. |
| 618 | Supplying and fitting and fixing stainless steel 34 grade in said rail using 5mm dia 2mm thick circular pipe and balustrade 32mmx32mmx2mm at the rate of mtr.Center to center and square pipe 32x32x2mm below including welding with stanless steel elect rod and fixing with necessary accessories etc.complete as per direction of the Engineer-in-charge. |
| 619 | Providing fitting and fixing RCPC cover etc complete as per direction of Engineer-in-charge Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail