| 1 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared and all as directed including cost of all labour, tools & plants etc., and all other charges complete.(for proposed outside approach pathway) |
| 2 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift upto1.5 m. All kinds of soil. |
| 3 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. (for proposed outside approach pathway) |
| 5 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.(for proposed outside approach pathway) |
| 6 | Supplying and stacking at site. |
| 7 | Supplying and stacking of hard stone (for stone pitching) 22.5 cm thick at site. (Using150mm thick stones for dry stone packing) |
| 8 | Red bajri (Gravel) (For road shoulders & where ever necessary of existing WBM Road,consider 25% voids filling in Drystone pitching) |
| 9 | Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density |
| 10 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 4Kg/cm2 |
| 11 | 110mm |
| 12 | 50mm |
| 13 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. |
| 14 | Cement Concrete work |
| 15 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand(zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 16 | Providing and laying in position cement concrete of specified grade- All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete |
| 18 | Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. |
| 19 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) |
| 20 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. (For Kerb wall) |
| 21 | Supplying & fixing of Painted cement concrete flower pots of size 30x30cm, filling with fertility soil, flower plant size 30x60(H) cm of Lilly, rose, Moss Rose, Crown of Thorns, Aloe Veera, Chineese Hibiscusalong with proper watering & maintenanceupto completion of entire work. all as directed and as per directionof Engineer-in-Charge including supply of allmaterial, labours, transportation, lead & Lift, tools & plants and all other charges etc., complete. |
| 22 | Supplying & fixing of frut plantation of size 0.60x1.20m Sapota, jack fruit, Mango, Guava,including earth work 0.60x0.60x0.60m & back filling , filling with fertility soil along with proper watering & maintenanceupto completion of entire work. all as directed and as per directionof Engineer-in-Charge including supply of allmaterial, labours, transportation, lead & Lift, tools & plants and all other charges etc., complete. |
| 23 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work.(2 or more coats of SE Paint at all heights of LH Tower including scapping, cleaning, scaffolding, safety measures, ropes, bosum chair etc.) |
| 24 | Construction of 4 m Dia Circular Gazebo with Platform with following details:1. Supply, fabrication and fixing of GI Class \"C\" pipes, Hollow tube section, angles, Flats and plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete 1.60 mm thick with zinc coating not less than 350 gm/m2. 2. Size ofGazebo platform will be 4m Diax 1.2m (height) above GL andfoundation depth shall be 0.65m. 3. Curve shaped entrance steps with inner width of 2.0m and widening at outside with lower step 2.70m width. 4. 18mm thick pre polished circular granite platform at 0.80m from floor level of Gazebo.5. The foundation work will include Earth work in excavation & back filling, Dry stone pitching, PCC 1:2:4 for foundation & floor including shuttering work, brick wall in CM (1:4), plastering in CM (1:4) for all round periphery 6. Providing & laying anti skid tiles for flooring of Gazebo & steps.7. 2 coats exteriorpaint with primer for exposed walls, SE Paint 2 coats with Zinc primer for metal surfacesAll works complete all as per drawingand standard specifications and as directed by Engineer I/C including cost of allmaterial,labours,transportation, lead & lift, tools & plants and all other charges etc., complete. |
| 25 | Part - BSupplying and fixing 6 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of 2 poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 26 | Double pole (3 for New street light and 1 for Gazebo & 12 for existing street light) |
| 27 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering (bricks) and refilling the trench etc as required.(0.45 X 0.45 X 2M) |
| 28 | Upto 35 sq. mm |
| 29 | Supplying and making end termination with brass compression gland and Aluminum/Copper lugs for following size of PVC insulated and PVC sheathed / XLPE Aluminum/copper conductor cable of 1.1 KV grade as required. |
| 30 | 2 X 6 sq. mm (19mm) (3 X 2.5 qmm Not avialable) |
| 31 | Supplying of 30W LED street light fitting, die-cast aluminium powder-coated enclosure with structured LED arrays, IP65/66 protection, complete with driver and all accessories, suitable for operation on 230V AC supply, including testing at site, as per IS standards and as directed by the Engineer-in-Charge. (3 for new, 12 for existing street light) |
| 32 | Supplying of pole-mounted junction box with side-hinged door, IP55 protection, size 300 × 200 × 110 mm (L × W × D), complete with mounting arrangements, suitable for outdoor installation, as directed by the Engineer-in-Charge. (3 for new, 12 for existing street light) |
| 33 | Supplying of 3-core, 1.5 sq.mm, PVC insulated copper cable for wiring from street light fitting to junction box and gazebo, conforming to IS standards, complete as directed by the Engineer-in-Charge |
| 34 | Supplying of modern decorative pendant light fitting with 7W LED lamp(warm white), IP65 protection, complete with all accessories, suitable for outdoor installation, as directed by the Engineer-in-Charge. |
| 35 | Supplying of 3-core × 2.5 sq.mm, armoured, copper conductor, XLPE insulated power cable, conforming to IS 7098 (Part 1):1988, for laying from powerhouse to street light point & Gazebo, complete as directed by the Engineer-in-Charge. |
| 36 | Supplying and installation of Class \"C\" GI pipe pole, 3\" diameter, 4 metres in length (single piece without joint), including fixing in position, applying one coat of primer and two coats of aluminium paint over the full length (without cutting), complete as directed by the Engineer-in-Charge. |
| 37 | Supplying and installation of Class \"C\" GI bend pipe, 1\" diameter, 1 metre length (hydraulic bend 30 Degree angle), including fabrication charges, applying one coat of primer and two coats of aluminium paint, complete as directed by the Engineer-in-Charge. |
| 38 | Supplying and installation of GI reducer from 3\" diameter to 1\" diameter, including applying one coat of primer and two coats of aluminium paint, complete as directed by the Engineer-in-Charge. |
| 39 | Fabrication charges for making threads on both ends of 3\" & 1\" diameter GI pipe, complete as directed by the Engineer-in-Charge. |
| 40 | Supplying and fixing GI or aluminium “U” clamps/strips with brass screws, brass bolts, and nuts, for fixing junction box, complete as directed by the Engineer-in-Charge.(3 for new, 12 for existing street light) |
| 41 | Installation of pendant light at the gazebo, including wiring connections, testing, and use of required tools, complete as directed by the Engineer-in-Charge. |
| 42 | Installation of outdoor street light fitting and street light junction box on a 4-metre height street light pole, including drilling necessary holes in the GI pole and junction box(3 for new, 12 for existing street light) |
| 43 | Supply and fixing 40mm UPVC pipe (To fixing foundation for laying cable from underground to upto junction box) |
| 44 | Supplying and fixing 25 mm diameter PVC conduit pipe in gazebo, including bends, couplers, saddles, and other accessories, with proper clamping and alignment, complete as directed by the Engineer-in-Charge. |
| 45 | Supply and fixing of 6 Way 16A backlite connector on Junction box with brass screws, brass bolt and nut.(3 for new, 12 for existing street light) |
| 46 | Providing, laying, and fixing 75 mm medium class G.I. pipe with fittings in trenches within RCC road, including trenching, refilling with RCC materials, and using all necessary machinery and tools as required. |
| 47 | Painting of existing street light poles, including removal of old paint with emery paper, application of one coat of primer, and finishing with two coats of aluminium paint, complete with all necessary tools, materials, and labour charges |
| 48 | Dismantling of 1 No. street light pole and 12 Nos. junction boxes, including disconnection, unbolting, complete as directed by the Engineer-in-Charge. |
| 49 | Earthwork excavation (0.6 × 0.6 × 0.7 m) for the foundation of the streetlight; providing and laying 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) concrete work (0.6 × 0.6 × 0.9 m) for the foundation and (0.7 × 0.7 × 0.1 m) for base PCC, including shuttering, with the post pipe placed in concrete and provision for cable entry pipes; providing 8 mm steel reinforcement vertical bars – 8 Nos and horizontal bars – 5 Nos; construction of plinth base in 1:2:4 concrete (0.7 × 0.7 × 0.1 m); 12 mm thick plastering work in C.M. (1:4) for the post base [(4 × 0.65 × 0.5) + (0.6 × 0.6 top)]; and painting work consisting of one coat of white primer and two coats of synthetic enamel red paint [(4 × 0.6 × 0.5) + (0.6 × 0.6)], complete as directed by the Engineer-in-Charge. |
| 50 | Supply of miscellaneous installation materials, including clamps, screws, insulation tape, cable glands, ferrules, red synthetic enamel paint, white primer, aluminium paint, and red oxide primer, MCB Railing complete for installation works as instructed by the Engineer-in-Charge. |