| 1 | Excavation in post holes each not exceeding 0.5 cum getting out in any type of soil, removing surplus soil to a distance not exceeding 50m, complete all as specified. |
| 2 | Plain Cement Concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation ofpoles/struts etc including necessary form work and fair finish to exposed surfaces without using extra cement, complete all as specified and directed. |
| 3 | fixing only MS galvanised coated chain link fencing n exc4.0Kg per sqm with size of mesh 50 x 50mm and thickness of wire n.exc 3.15mm including line wires including provision of binding wire and fixing to poles with TMT bars,screws/bolts,flat ironall as specified and directed.Note:TMT bars 10mm dia, flat iron,mild steel screws/bolts,shall be measured and paid seprately under relevant item |
| 4 | Supply only MS galvanised coated chain link fencing n exc4.0Kg per sqm with size of mesh 50 x 50mm and thickness of wire n.exc 3.15mm including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wireall as specified and directed. |
| 5 | Mild steel angle iron as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc. flat iron fillets (for securing wire mesh etc). Including all necessary drilling, bolting or riveting etc. and similar work conforming to Fe-290 Gde E-165, complete all as specified and directed. |
| 6 | Supply only TMT bar, 10mm dia and over, for support/line wire to chain link fencing complete all as specified snd directed |
| 7 | Supply ony flat ironconfirming to Fe-410-W (Gde-E-250) completeall as specified. |
| 8 | Supply only Mild steel screw bolts 11-15mm dia at neck, machine made, with hexagonal or square heads at one end and screwed the other, or screwed both ends; each screwed and to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm but n exc 15cm long, complete all as specified and directed. |
| 9 | Preparation of new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat ofprimer, complete all as specified and directed. |
| 10 | Preparation of new or previously untreated steel surfaces of any description under 10cm widthand applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 11 | Galvanised 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including, securing or lying at crossing with and provision of galvanised mild steel wire, staples or steel pins etc,(each line wire to be measured) fixed in repair complete all as specified |
| 12 | Concertina coil 600mm dia / 56 loops / 2.5 mm core wire,Coil Diameter: 600 mm, Type of Strip: Heavy Galvanised (IS:1703), Type of Core wire: Heavy Galvanised (IS:280-2006), Core wire Diameter: 2.50 mm Dia,Zinc Coating to Strip: Minimum 200 GSM/sqmm, Zine Coating on wire: Minimum 275 GSM/sqmm (IS 6745-1972 reaffirmed 2006), Tensile Strength of wire 1400-1500 N /sqmm, Weight: 6-8 Kg (± 5%), Number of Loops: 56. Blade Length: 22 MM, Barb Profile: Medium Blade (MBBT), Distance Between Barb. 35 mm, Stretchable length 6-8 mtrs,Type of clip: Hardened Steel in Galvanised steel, complete all as specified & directed.Note: Measurement of concertina coil during payment shall be done as per \"Weight ascertained by BOO\". to be commanded by GE |
| 13 | Excavation in trenches not exceeding1.5 m wideand not exceeding 1.5 m deep for foundationincluding gettingout in any type ofsoil complete all as specified and directed. |
| 14 | Form work to sides of concrete foundations, footings, basis of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work; vertical or to better with rough finished surfaces of concrete complete all as specified and directed. |
| 15 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surface of square rectangular or polygonal concrete all as specified and directed. |
| 16 | Reinforced cement concrete Design Mix (M-25), (using 20 mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc. basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. |
| 17 | Reinforced cement concrete Design Mix (M-25) (using 20 mm graded crushed stone aggregate)in Columns, pillars, piers, posts and strutscomplete all as specified and as directed. |
| 18 | TMT bar, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified. |
| 19 | TMT bars, 6 to 8 mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia as in stirrups, complete all as specified. |
| 20 | 05mm thick cement plaster with cement mortar(1:4) on fair faces of brick work or concrete surfacesand finished the surface even and smooth without using extra cement, complete all as specified. |
| 21 | Granite (of any type) work 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platform and like including pointing in white cement (1:2) using marble dust with admixure of pigment to match with shade of granite over and including 15mm thick screed of CM 1:4 after applying cement slurry@3 kg/sqm of cement per sqm, complete all as specified.(Note : A hole shall be drilled in the Granite after fixing for gas pipe all as directed). |
| 22 | Mild steel framed workas in door or gate of angle or other section with gusseset plate rail braces complete drilled for fixing of steel sheeting or other covering . Door etc to be prepared for hanging of sliding with grills, grating etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, conforming to Fe-410-W(Gde-E-250) quality-A, complete all as per approved drg submitted by the contractor. |
| 23 | Returining filling in including spreading, levelling, watering and wall ramming in layers not exc 25cm in any type of soil complete all as specified and directed. |
| 24 | Removing surplus soilto distance not exceeding50 m and depositing where directed at a level notexceeding 1.5 m above the starting pointcomplete all asspecifiedand directed . |
| 25 | PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in parapet, coping,troughs and like weathering,slightly rounded or chamfered angles and throatingetc including necessary form work all as specified and directed |
| 26 | Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed. |
| 27 | Demolition of Cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided for includingremoval complete all as specified and directed. |
| 28 | Dismantling structural steel works/cast iron of any description complete all as specified and directed. |
| 29 | Brick work with sub class \"B\" bricks , straight or curved on plan exc. 6 mtr mean radius built in CM 1:6 complete all as specified and directed. |
| 30 | Rendering 15mm thick cement plaster with cement mortar(1:6) on other than fair faces of brick work or stone masonry surfacesand finished even and smooth without using extra cement complete all as specified and as directed. |
| 31 | Excavation over area not exceeding 1.5 m including gettingout in any type ofsoil complete all as specified and directed. |
| 32 | Excavation over areaexceeding 1.5 m and not exc 3m deepincluding gettingout in any type ofsoil complete all as specified and directed. |
| 33 | Form work to fair faces of walls, retaining walls, abutments, Parapets and staircase railings and similar work including attached pillasters, buttresses etc vertical or to better with fair finished surface of concrete complete all as specified and directed |
| 34 | Preparation of newly plastered surfaces of walland applying two coats of cement base paint over a coat of alkali resistant primer, complete all as specified and as directed. |
| 35 | 150 mm diaPVC (SWR) pipe single socketed in any length with rubber ring joint laid intrenches or in floor all as specified and directed |
| 36 | Plain Cement Concrete (1:2:4) type B-1 (using 20 mm graded crushed stone aggregates) as in roof kerb cills, steps, Parapets, hold fasts, plinth bands bed blocks including weathering, slightly rounded or chamfered angle and throating, necessary form work finishing all exposed faces of concrete etc complete all as specified and directed. |
| 37 | Construction of Double story elevated sentry post includingconnected items with permanent specification and in RCC framed construction.complete all as specified and shown on drgCEUZ/WD/AR-07 B/2019 Sh 1/2 , CEUZ/WD/AR-07/2016 Sh 1/2, 2/2 |
| 38 | Surface excavation n exc 30cm deep and averaging 15 cm any type of soil all as specified and directed. |
| 39 | Hard core of broken stone/boulders of gauge n exc 63mm deposited spreed and leveled in layers n exc 15cm thick watered and rammed to a true surface, complete all as specified. |
| 40 | 100mm thick PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in sub base of floor/hardstanding etc, finishing surface even and rough to receive topping layer, complete all as specified and directed |
| 41 | Sand cushioning in flooring below interlocking tiles laid in layers 25mm thick complete all as specified and directed. |
| 42 | Machine pressed precast concrete interlocking paver block of any shape and size confirming to marked IS:15658-200660mm thick,M-35 grade , in paths and hardstanding,with grey cement and coloured pigment, laid tightly overand joints filled with dry sand. (Colour and pattern as approved by GE) complete all as specified and directed. |
| 43 | Materialand labour for point wiring complete with 1.5 sqmm PVC insulated, FRLStype, ISI marked,conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCcasing and copping of suitable size andincluding cutting, chasing work at any height and all accessories are concealedinwalls / roofs / floors / ceiling etc. metal flush boxwith top,bottom,side/back wall knockout for conduitentry from any direction made out of 1.60mm thick suitable for fixing ofmodular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved colouresandincluding 1.5 Sqmm PVC insulated multistranded FRLStype unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providingputty and white cementfor smooth finishing of existing surfacecomplete all as specified and directedfor the following:-(Note:- Allnecessary accessories such asmodular steelbox,top cover plate, blank plate, screws,washersshall be deemed in to included in quoted rate only.) |
| 44 | one light point/fan point controlled by one switch |
| 45 | One 3 pin 5 amps socket point controlled by one 6 amps switch on independent board . |
| 46 | One 3 pin 5 amps socket point controlled by one 6 amps switch on same board . |
| 47 | Modular type switch 6 Amps, single pole, 1way,1 module, 240V, ISI Marked Complete all as specified and approved. |
| 48 | Modular type socket shuttered type 6 Amps- 2/3 Pin combined 2 module,240V,ACISI Marked Complete all as specified and directed. |
| 49 | Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed. |
| 50 | Ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed |
| 51 | Supply & fixing LED batten 22W, 220V, AC general purpose surface and wall mounted of extrudedaluminium housing integrated electronic driver 20 watt, 4 feet incl copper conductor cable of suitable size from tube light to ceiling rose complete all as specified and directed. |
| 52 | LED INVERTER batten 20W with square profile and poly carbonate channel lithium ion battery with charging time 8 to 10 hours and backup time upto 4 hours and connecting up with twin core twisted copper wire from LED fitting to ceiling rose complete all as specified and directed. |
| 53 | LED bulb 12 watts, 240Volts,50Hzpin type andincluding removing old unserviceable itemcomplete all as specified and directed.Cat Part No-LHLDEUEEML8R012 Havells or its equivalent in Bajaj, Surya as approved. |
| 54 | LED security light fitting of capacity30 Watt LED street light fitting in aluminium PDC housing, toughened glass cover with IP65 protectionwith suitable inbuilt surge protector and cable connection from ceiling rose to light fitting and testing andcomplete all as specified and directed. |
| 55 | Supply & fixing and in repair sheet metal enclosure acrylic door 240 volts AC,SPNdistribution board04 wayfor flush mounting with 100amps copper busbar, neutral bar,earth barand MCB incomer and MCB SP as outgoing and complete connecting cable linkswith top and bottom removable gland plate withIP 36 DBs protection and including making good the disturbed surfaces all as specified and as directed. |
| 56 | MCB SP 6 to 32 Amps 10 KA,\"C\" series,AC,240Volts,50Hz , ISI marked complete all as specified and directed. |
| 57 | MCB single pole & neutral 32 amps 240 volts 10 KA \"C\" series fixedcomplete all as specified. |
| 58 | Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground leel, connecting to the Galvanised earthing lead strip 32x6mm size, by means of bolts, nuts, heck nuts and washers of galvanized iron andearth lead protected by provision of GI medium grade pipe 65mm bore incl provision of concrete pit in PCC 1:2:4 type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC 1:2:4 reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 02 Nos and with 6mm dia MS bar handle made to shape GI medium grade 40mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt & charcoal filling, test point made out of 17mm x 8mm FI with fixing arrangement, funnel, wire mesh and earth work in soft/loose soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs, all as per electrical plate No 5 of SSR-1991 Part I and connected to earth test point all as specified or indicated incl testing on completion. |
| 59 | Sub main wiring in replacement complete with2 run of 2.5 sqmm single core copper conductor (ISI marked)cable1100 volts grade,FRLSH type, PVC insulated, unsheathed,flexible,multi strandedcolour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade(MMS) with all connected accessories such asBend, Tee, Elbow, Short peices etc concealed in wall/roofs/floorsand including one run of 2.5 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour code and applying putty including cutting and chiseling and complete all as specified and directed.Note : - Two run of 2.5 sqmm single core copper conductor cable and one run of 2.5 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as RM. |
| 60 | Ceiling fans complete with blades, down rods, and accessories, 230 volt, 1200mm sweep, min air delivery 210 CFM with service value 6 BEE five star rated with brushless direct current motor (BLDC)complete all as specified and directed. |
| 61 | Supply laying & testing ofXLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminium conductor, 1100 volts grade of size 10 Sqmm nominal cross section x 2 core, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointingwith suitable size aluminium lugs complete all as specified. |
| 62 | DWC HDPE tubing 40/32 mm(outer dia/inner dia )for open and underground cable cut to size and making the tubing for cable protection incl cutting of road surface & making good after laying of tubing, complete all as specified and directed. Note:- Rate for GI clamp with screws required for fixing of HDPE tubing in the wall/drainage shall be inclussived in quoted rate. |
| 63 | Excavation in tranches not exceeding1.5 m wideand not exceeding 1.5 m deep for laying cable including gettingout in any type of soil complete all as specified and directed. |