| Sl. No. | Item Description |
| 1 | Comprehensive & preventive maintenance/overhauling of Pump-Motors (any type) of Various Capacities atall Booster/Pump Houses in Kanasar Military station area, including daily servicing/Maintenance of all installations comprising with booster/pump houses by qulified Technical/experience rep to check/inspect and maintain all pumps and their connected items, Motors with their connected items, Electrical/control panel with all connected items, inspection and maintenance of all type of assets for smooth & trouble free functioning of Pump-Motor complete all as specified and as directed. (all pumps repair/overhauling done in pump house premises, only damage part will be sent to workshop)Job Consist with the follwing :-(i) Regular inspection and servicing of all EM assets/installation comprising with Booster/Pump house, with Techanically qualified/experience person (manpower is available for 24 hrs for regularly/emergency) and rectify the issues on immediate basis.(ii) Taking down/dismantling of defective induction/Sumbersible or (any types) motor of any capacity and make from the foundation, disconnecting the electric connection. coupling, pulley, with all connected items for cleaning, servicing, Minor/Major repair and refixing in the same position, making necessary electric connection and testing of induction/sumbersible/(any type) motor after rectification of issue complete all as specified and as directed by Engineer-in-Charge as per site requirment.(iii) Taking down from foundation, base frame by disconnecting suction & delivery lines and coupling, opening including dismantling of centrifugal/Sumbersible/Monoblock or (any types) pump set of any make & any capacity for servicing/cleaning/Major or Minor Repair/replacement of worn out spare parts as per site requirment and re-assembling, installation in same location including testing after complete rectification all as specified and directed by Engr-in-Charge, The booster pumps installes at VIP huts at various loc servicing from authorised dealer for 2 in each month (i.e 8 in each job) with replacement of required items is include in quoted rate.(iv) M&L for finding and Repair/rectification of all type of complaints against Pumps/motors/NRV/Sluice Valve/Starter/water supply pipe lines (Sunction/Delivery) like Motor not working/pump not working/leakage/blockage/no water supply/no suction of pump etc,(any type) against day to day maintainence/services complaints. Contractor shall be responsible for complete check and found exact issue, Complaint shall be rectified by the contractor within 4 hrs from the launch of complaint time through complaint slip/ teliphonically/messaging. If contractor fail to rectified the above said complaint in given time period then a penalty @ Rs 500/hr will be recovered agaist the each job/complaint. Complete site cannot be handed over to contractor, site of defective pump/motors & leakage/blockage/no water supply as per complaint received by operator is only handed over to the contractor on site requirment basis. M&L for cleaning & Checking for make proper serviceable ofsuction & delivery water supply pipe line, foot valve,sluice valve, NRV, instruements, starters, connected control cabling/wiring including electrical panels with switchgears complete as per direction of Engr-in-charge.(v) M&L for opening the gland cap from both side of centrifugal pumps (any type) and taking out the rusted gland dori completely and refilling the new gland dori with grease both side of pump and refixing the gland cap in same position as per requirment on site (as complaint given). (all pumps repair/overhauling done in pump house premises, only damage part will be sent to workshop and work done in front of MES rep within 4 hours, all transport and other arrangment done By contractor).(vi) M&L for opening the gland cap from both side of sluice vale at booster/Pump house/all staion area /(Rising lines of OHT/Sump or delivery lines) and taking out the rusted gland dori complete and refilling the new gland dori with grease both side of sluice valve and refixing the gland cap in same position.(vii) Contractor shall provide Techanically qualified/experience person for fault attending within 1 hrs and rectify within 4 hours. If the Supply/Booster/Pump-Motor is off load/break down more than 8 hrs, a penalty at the rate of Rs. 5000/- per day shall be levied and deducted from the contractor\"s payment. The contractor shall be provide/arrange alternate option for defective pump/motor of any capacity or make as per site for avoiding supply failure in case repair/replacement of defective parts takes longer time in genuine condition (condition is fixed by Engr-in-Charge), the expense is deemed in quoted rate and no extra amount paid on this account.(viii) During entire contract period any defective components or any other materials which is not specified in Sch \"A\" but required repair/replacement to make plant/ machinery fully functional, the cost of same shall be deemed included in quoted rates and nothing extra shall be paid to the contractor on this account.(ix) M&L for checking/dismantling/repair//Replacement of U/S leather washers heavy duty with new leather washer heavy duty (ISI marked) suitable for foot valve of existing size dia bore at all booster/pump houses. Complaint for same given in complaint slip, during Four month quarter repair of foot valve & NRV will be done as per complaint received. Complaint should be rectify within 4 Hours after launch of complaint, if contractor fail to done that recovery of Rs. 500/- per hours shall be levied and deducted from the contractor\"s payment. (x) M&L for dismantling of NRV(anysize & Make) carefullyafter disconnectingfrom suction/delivery line of pumping set unscrewing the both side taking out seat with level and labour and material from replacementof leatherwasher cleaninginside seat space reassembling, reinstalling back complete as per site requirment. contractor should be provide lather sheet of 4mm thick at each pump house minimum 2 sqmtr.(xi) M&L for applied super quality Grease for Bearingthrough gun machine in two times in a month complete all as specified and directed by Engr-in-Charge.(xii) Checking of motors with complet Electric connection and rectifying with requird assesories (minor) including making connections/ Disconnection for making serviciable or for routine check as per direction of Engineer-in-charge.(xiii) Shifting of pump-Motor set or pump & motor separately in emergency requirment complete with required fittings as per site complete and rate is include in quoted rate all as specified and directed by engineer-in-charge.(xiv) M&L for repair/metal coating/lath work for shafts, impeller, Impeller body, housing case of bearing, pump body, gap between upper and lower body jointd in gland packing area including welding/(gas welding) of pump-motor/replacement of petty/minor items for upgradation/repair other than specified in Sch ‘A’such as shaft seal/ keys/seals/sleeves/fans/studs and other minor repairs as ordered by Engr-in-Charge, transportation to workshop & back to site and make serviceable compete shall be deemed to be included under this job all as specified and directed by Engr-in-Charge. |
| 2 | Note : (for item No 1)(i) All complaints for repair/replacement/servicing/cleaning/shifting shall given by department (JE E/M or MCM)on daily basis forthis complete job (Ser item No. 1), contractor shall rectify all complaints within 4 hrs after launch of complaint and return the complaint slip with operator sign (for confirmation of rectification) to complaint cell on daily basis. Contractor shoul provide 1x pump-motor mechanic and 1 x helper on daily basis during contract period. Daily collection of complaint slip, transportation and other necessary equipments shall be arranged/brought by the contractor, hence the bidder is advised to visit the site and assess the quantum of the work to be carried out in the contract and quote their rate accordingly.(ii) All above points mentioned in job for the period of one months shall be considered as one Job, Each Job shall be measured and paid in one calendar months. (iii) Dismanling and refiixing of pump & motor job, Gland filling in Pump & Sluice Valve Job is not fixed in numbers, this Job will be done as per site requirment hence contractor dose not denay for the same, and do not claim extra on this account. Refixing is done after rectifying the issue/complaint hence it coverd labour charges for fixing/replacing required spare parts/items and all connected expense, major Spare parts for Repair of pumps and motor shall be measured and paid separately.(iv) Complaints given for regular problems/issue facing by operator and all type of complaints against any type of pumps and motors includind water supply/priming pipe lines shall be rectified by the contractor within 4 hrs from the launch of complaint time through complaint slip/ telephonically/messaging. If contractor fail to rectified the above said complaint in given time period then a penalty @ Rs 500/hrs will be recovered for contractor payment. Complete site cannot be handed over to contractor, site of leakage/pump & Motor not working/foot valve not working/NRV not working/blockage/shifting as per complaint received by operator is only handed over to the contractor on site requirment basis.(v) Contractor should collect complaint slip on daily basis from 09:30 to 10:30 hrs without fail and deposite the same after rectification within time period of 12 hrs, if contractor fail to deposite complaint slip with operatort sign with date, then consider as delay in rectification period, which leads to recovery.(vi) Checking of NRV/Foot valve including taking up, cleaning inside and refixing after testing for nonfunctioning complaint is include in this job and no extra cost shall paid to contractor. Repair of foot valve/NRV/ is paid seperatly if any part found unserviceable or required lath work for make functional. (vii) All T&P and vehicles for transpotation will be provide by contractor and no extra payment made out on this account, replacement of petty/minori tems other than specified in Sch \"A\" such as Shaft seal/Keys/seals/sleeves/studs or as per site requirment shall be deemed to be included in the rate quoted by contractor under this item. (iv) Contractor Shall provide required manpower with all required tools/equipments for attending emergency complaint for 24 hours no extra payment made out on this account. Contractor is responsible for deposite the old unsv material received against replacent toAGE Kanasar store yard and rate is included in quoted rate.(viii) Contractor should provide minimun 75% material within 7 days after work order issue, all pump-motor repair must done in kanasar station, if need to take to workshop then one rep from MES will be present during work and all arrangment done by contractor. Quoted rate deemed to be inclusive of all labour, equipment and T&P material/arrangment to attend the day to day maintenance complaint on daily basis.(ix) Contractor shall update daily executed work on daily basis with sign of user/operator on complaint slip (maintaining work done register) to concern JE E/M/MCM for updating exact progress of contract agreement. |
| 3 | M&L for taking out submersible pump and motor 15/20 HP capacity from the tube well lowered at the depth of 90 to 200 mtr from the ground level including taking out GI flanged column pipes 80 mm bore of 03 metre length each (column pipe are provided with flanged joints at every 03 metre length) and two Nos submersible cable 3 core of any size incl disconnecting electrically and delivery out let pipe including opening of flanged joints of column pipe and stacking it in safe custody for reuse as required for repair of sumbersible pumpset complete all as specified and directed.Note:- Repair work and spare parts of pumps and motor shall be measured and paid for separately under relevant items here-in-after. |
| 4 | M&L for Lowering of vertical type submersible pump set of capacity 15/20 HP into the borewell after repair and testing including refixing column pipes and submersible cables upto 200 mtr below ground level with the help of chain pully block including new rubber gasket between flange joints with nut / bolt / washers of column pipe (3 m length) making electrical connections, testing and commissioningof pump setin borewell for satisfactory operation complete all as specified and directed by Engr-in-Charge. |
| 5 | Opening, reassembling and testing of submersible motor after rewinding & replacement of worn out spare parts incl rewinding of submersible motor 15/20 HP of03 Phase, 415 voltswith PVC insulated solid copper conductor (wire) superior quality of approved make , size & number of wire as per existing complete and also replacement of worn out cable connections, testing and commissioningof motor after rewinding complete all as specified.Make of Motor : CALAMA/SABAR/KSB/BED FORD GARVIN/KIRLOSKAR.Note:-(i) The spare parts required to be replaced shall be measured and paid for separately as \"Supply only\" under the relevant items here-in-after. (ii) Unit rate (quoted by the tenders) shall be deemed to include for all minor spares/extras. The decision of accepting officer regarding minor spares/extras shall be final, conclusive and binding. |
| 6 | Material only the following spare parts for submersible motor capacity 15/20 HP, 3 phase, 415 volts against item Ser No 2 above. |
| 7 | GM Bush/GM housing Bush |
| 8 | Rotor sleeve |
| 9 | Water seal |
| 10 | Thrust bearing Make- NBC/SKF |
| 11 | Housing upper |
| 12 | Housing lower |
| 13 | Cable seal |
| 14 | Thrust plate |
| 15 | Coupling S/S |
| 16 | Key for coupling |
| 17 | Allen key bolt S/S |
| 18 | Revolving disc |
| 19 | Seal bush |
| 20 | Sand guard |
| 21 | Rotor |
| 22 | Stator |
| 23 | Opening, reassembling and testing of submersible pump (15/20 HP) of capacity 2000 to 6000 GPH including replacement of the worn out spare parts as mentioned under respective item no (2) here in after.Make of pump: CALAMA/SABAR/KSB/BED FORD GARVIN/KIRLOSKAR. |
| 24 | Material only the following spare parts forsubmersible pump (15/20 HP) cap 2000 to 6000 GPH |
| 25 | Stage bowl |
| 26 | Impeller GM. |
| 27 | Pump shaft S/S (as per site) |
| 28 | Hook bolt (Upper & lower) |
| 29 | GM neck ring |
| 30 | Key for pump shaft (Each stage) |
| 31 | Distance sleeve |
| 32 | M&L to the extant required replacement under item No 3 here in before 80 mm bore GI pipe (length of six meter for each job) heavy grade with flange not less than 12mm thick duly drilled holes on each end, screwed and welded with necessary packing/jointing nut bolts & washers with four MS flat of size 12 x 6 mm support on each flange with suitable cut/opening for cable complete all as specified and as directed by Engineer-in-Charge. Note : Old Unsv/Replace items deposited to AGE E/M Store Yard including transportation and labour by contractor no extra payment made on this account.Make : Jindal/Prakash Surya/ TATA |
| 33 | Taking down of defective induction motor of the following capacity and makefrom the foundation, disconnecting the electric connecting coupling pulley and transporting to work shop cutting down and removing existing burnt out copper windings, cleaning of slots and rewinding with solidcopper conductor ( winding wire) complete including varnishing, drying, ovening, overhauling, greasing and fixing in the same position, making necessary electric connection and testing of induction motor complete all as specified and as directed by Engineer-in-Charge. Note : Old Unsv/Replace items deposited to AGE E/M Store Yard including transportation and labour by contractor no extra payment made on this account. |
| 34 | 2 to 5 HP capacity, 03 phase 415 volt 50 HZ |
| 35 | 7.5 to 10 HP capacity, 03 phase 415 volt 50 HZ |
| 36 | 12.5 to 15 HP capacity, 03 phase 415 volt 50 HZ |
| 37 | 20 to 25 HP capacity, 03 phase 415 volt 50 HZ |
| 38 | 30 to 40 HP capacity, 03 phase 415 volt 50 HZ |
| 39 | 50 to 60 HP capacity, 03 phase 415 volt 50 HZ |
| 40 | Material only the following spare parts for centrifugal pump of 50 HP capacity (any make & Model as per site)required to be replacedunder item No 1 above as specified and directed by Engr-in-charge. |
| 41 | Inter stage ring |
| 42 | GlandCap CI with nut bolt complete |
| 43 | Gland/pump sleev bush/bushing SS type |
| 44 | Wear ring CI |
| 45 | Shaft Sleeve Bronze |
| 46 | Shaft Sleeve Nut (Bronze) |
| 47 | SS pump shaft as per existing |
| 48 | GM impellar comlete with impellar key |
| 49 | Gasket set manifold |
| 50 | Air release cock brass type as per site |
| 51 | Set of \"O\" Rings |
| 52 | Material only the following spare parts for centrifugal pump of 40 HP capacity (any make & Model as per site)required to be replacedunder item No 1 above as specified and directed by Engr-in-charge. |
| 53 | Inter stage ring |
| 54 | GlandCap CI with nut bolt complete |
| 55 | Gland/pump sleev bush/bushing SS type |
| 56 | Wear ring CI |
| 57 | Shaft Sleeve Bronze |
| 58 | Shaft Sleeve Nut (Bronze) |
| 59 | SS pump shaft as per existing |
| 60 | GM impellar comlete with impellar key |
| 61 | Gasket set manifold |
| 62 | Air release cock brass type as per site |
| 63 | Set of \"O\" Rings |
| 64 | Material only the following spare parts for centrifugal pump of 25/30 HP capacity (any make & Model as per site)required to be replacedunder item No 1 above as specified and directed by Engr-in-charge. |
| 65 | Inter stage ring |
| 66 | GlandCap CI with nut bolt complete |
| 67 | Gland/pump sleev bush/bushing SS type |
| 68 | Wear ring CI |
| 69 | Shaft Sleeve Bronze |
| 70 | Shaft Sleeve Nut (Bronze) |
| 71 | SS pump shaft as per existing |
| 72 | GM impellar comlete with impellar key |
| 73 | Gasket set manifold |
| 74 | Air release cock brass type as per site |
| 75 | Cooling pipe for Gland (2 Nos) |
| 76 | Set of \"O\" Rings |
| 77 | Material only the following spare parts for centrifugal pump/Monoblock pump of 15 to 20 HP capacity (any make & Model as per site)required to be replacedunder item No 1 above as specified and directed by Engr-in-charge. |
| 78 | Inter stage ring |
| 79 | GlandCap CI with nut bolt complete |
| 80 | Gland/pump sleev bush/bushing SS type |
| 81 | Wear ring CI |
| 82 | Shaft Sleeve Bronze |
| 83 | Shaft Sleeve Nut (Bronze) |
| 84 | SS pump shaft as per existing |
| 85 | GM impellar comlete with impellar key |
| 86 | Gasket set manifold |
| 87 | Air release cock brass type as per site |
| 88 | Impeller Housing body complete as per existing make and model |
| 89 | Set of \"O\" Rings |
| 90 | Material only the following spare parts for centrifugal pump/Monoblock pump of 10 to 12.5 HP capacity (any make & Model as per site)required to be replacedunder item No 1 above as specified and directed by Engr-in-charge. |
| 91 | Inter stage ring |
| 92 | GlandCap CI with nut bolt complete |
| 93 | Gland/pump sleev bush/bushing SS type |
| 94 | Wear ring CI |
| 95 | Shaft Sleeve Bronze |
| 96 | Shaft Sleeve Nut (Bronze) |
| 97 | SS pump shaft as per existing |
| 98 | GM impellar comlete with impellar key |
| 99 | Gasket set manifold |
| 100 | Air release cock brass type as per site |
| 101 | Cooling pipe for Gland (2 Nos) |
| 102 | Set of \"O\" Rings |
| 103 | Supply only the following spare parts for centrifugal pump set of capacity 5 HP against serial item No. 1.00 here in before as per existing make . |
| 104 | SS Pump shaft. |
| 105 | CI Impeller complete with impeller key. |
| 106 | Shaft sleeve bronze with locking screw & lock nut. |
| 107 | Wearing ring (DE &NDE) CI |
| 108 | Set of\"O\" ring |
| 109 | CI gland cap with eye bolt complete. |
| 110 | GM gland sleeve bush. |
| 111 | Supply only the following spare parts for centrifugal pump set of capacity 2 HP against serial item No. 1.00 here in before as per existing make . |
| 112 | SS Pump shaft. |
| 113 | CI Impeller complete with impeller key. |
| 114 | Shaft sleeve bronze with locking screw & lock nut. |
| 115 | Wearing ring (DE &NDE) CI |
| 116 | Set of\"O\" ring |
| 117 | CI gland cap with eye bolt complete. |
| 118 | GM gland sleeve bush. |
| 119 | Note for Ser item No 5, 7 & 10 to 16 :-(i) All spare parts shall be fixed in the pumps only after prior inspection & approval of Engineer-in-Charge (ii) Old Unsv/Replace items deposited to AGE E/M Store Yard including transportation and labour by contractor no extra payment made on this account. |
| 120 | Material for replacement of old/Unsv Ball bearing of required size as per site suitable for pumps & motors offollowing HP completeunder item No 1 above as specified and directed by Engr-in-charge. |
| 121 | For pumps & motors of0.5 HP to 7.5 HP complete as specified and directed by Engr-in-charge. |
| 122 | For pumps & motors of10 HP to 30 HP complete as specified and directed by Engr-in-charge. |
| 123 | For pumps & motors of 40 HP to 75 HP complete as specified and directed by Engr-in-charge. |
| 124 | Material for replacement ofFlexible tyre/star type coupling suitable for 40 to 75 HP motor-pumping set completeunder item No 1 above as specified and directed by Engr-in-charge. |
| 125 | Material for replacement ofFlexible tyre/star type coupling suitable for 5 to 30 HP motor-pumping set completeunder item No 1 above as specified and directed by Engr-in-charge. |
| 126 | Material and Labour for repair to unserviceable sluice valve of following size bore by dismantling and opening the gland cap and head of sluice valve (any make & Model as per site)required to be replacedabove or any Location in entire station as specified and directed by Engr-in-charge, including taking out the unserviceable lock check nut/gasket/Gland flange/gland bush/screw/O-ring/Wedge/body Ring/wedge nut/thurst bridge/spindle and taking to workshop for reapir the same as per site requirment including fitting the material, grinding the material cutting the threads as per requirment by lathe machine and fabrication of new lock nut or any unseviceable parts required at site for make serviceable (if Lock check Nut, Spindle & Gland bush cannot repaired then same will be replace with new and rate is inclusive in this account) complete and refixing in the same position with gland filling, testing the sluice valve, complete, all as specified and directed by Engr-in-Charge. |
| 127 | 80 mm dia bore. |
| 128 | 100 mm dia bore. |
| 129 | 150 mm dia bore. |
| 130 | M&L for suction/delivery/Priming MS pipe line of following size dia bore ISI marked heavy (not less than 6mm thickness) grade in short/long length both side flanged type/socket type or as per site requirment with gasket joint nut bolts washers complete with all fittings (like elbow, bend any degree, sockets, flange etc.) as per site requirment for any type, for jointing different type of pipes fittings also, laid in trenches or fixed to walls, ceilings or in floors with complete fittings all as specified & directed by the Engineer-in-Charge.Make:- Jindal/Swastik/TataNote :- (i) Rates quoted by tenderer incl taking up or down of lines for repair, cleaning of serviceable pipe internally/externally for re-use and refixing after repairing complete including cutting/screwing existing pipe/grinding/welding work as reuqired complete. (ii) Rates quoted by tenderer incl excavation, returning& filling,removing soil andmaking gooddisturbed surface on both side, Dewatering from trenches and taking out of mude etc with the help of JCB or mud pump as required at site andtaking out of broken/cracked pipe including welding work and duly painted with two coats of synthetic enemal paint over a coat of primer red oxide as reuqired complete. (iii) Rates quoted by tenderer incl labour cost for finding/tracing the exact issue regarding complaint and complete rectification. (iv) Complete site cannot be handed over to contractor, site of leakage/blockage/no water supply as per complaint received by user is only handed over the contractor on site requirment basis. |
| 131 | Size150 mm bore. |
| 132 | Size 100 mm bore. |
| 133 | Size 80 mm bore. |
| 134 | Size 50mm bore |
| 135 | M&L in replacement of metallic antivibration pads with rubber cushion for 75/60/50/40/30/25/20 HP motor pumping set including drilling hole at necessary places on foundation base frame. |
| 136 | Dismantlingand taking down pump set from base foundation frame by disconnecting electrically and from coupling side, taking out from foundation to safe place and demolition the old foundation and making new foundation with PCC (1:2:4) type B-1 using 20mmgraded stone aggregate including groutingof base hold fast 08 Nos and metalic anti vibration pads with rubber cusionincludingwatering levelingat same size after making of new foundation, fixing of old/new base frame as directed and installing of Pump motor and fixing same suctionand delivery all as directedby Engr - in- Charge, suitable for following capacity in HP. Note : (i) Any connected item is covered in quoted rate.(ii) Rate for cleaning of site is covered in quoted rate. |
| 137 | 40/50 HP |
| 138 | 10/20 HP |
| 139 | Taking down broken/rusted iron base frame and Supply and fixingnew iron base frame for centrifugal pump set upto 50 HP capacity as per existing sizewith two coats of black paint over a coat of red oxide zinc chrome primer complete all as specified by Engr-in-charge.Note : (i) Any connected item is covered in quoted rate.(ii) Rate for cleaning of site is covered in quoted rate. |
| 140 | M&L for cleaning ofwater supply installation in surrounding area (entire in fencing)/ surrounding area upto 10 mtr of OHT & sump including trimming, grass cutting etc two times in a contract period complete all as specified and as directed by Engineer-in-Charge. Note : Cleaning of each installation for three time considerd as one Job. |
| 141 | M&L for fixing in replacement MCCB of 100 Amps capacity triple pole breaking capacity 25 KA,FP, single frame, fixed thermal magnetic trip at 415 volts in existing panels of booster pump houses including making connections by using suitable size copper lugs/thimbles and crimping tool complete all as specified and directed by Engr in charge.Make: - Havells/ABB/LegrandNote : (i) The panels which is used for Water supply installations in station premises is liable for replacement of MCCB, all work carried out as per direction of Engr-in-charge. |
| 142 | M&L for fixing in replacement MCCB of following capacity triple pole breaking capacity 25 KA, single frame, fixed thermal magnetic trip at 415 volts in existing panels of booster pump houses including making connections by using suitable size copper lugs/thimbles and crimping tool complete all as specified and directed by Engr in charge.Make: - Havells/ABB/LegrandNote : (i) The panels which is used for Water supply installations in station premises is liable for replacement of MCCB, all work carried out as per direction of Engr-in-charge. |
| 143 | MCCB 4 Pole, 415 V, fixed type, 100 Amps with breaking capacity 16 KA |
| 144 | MCCB 4 Pole, 415 V, fixed type, 160 Amps with breaking capacity 36 KA |
| 145 | MCCB 4 Pole, 415 V, fixed type, 200 Amps with breaking capacity 36 KA |
| 146 | MCCB 4 Pole, 415 V, fixed type, 250 Amps with breaking capacity 36 KA |
| 147 | MCCB 4 Pole, 415 V, fixed type, 400 Amps with breaking capacity 36 KA |
| 148 | MCCB 4 Pole, 415 V, fixed type, upto 63 Amps with breaking capacity 16 KA |
| 149 | T&P and labour for fixing, jointing & testing of MCCB upto 630 Amps capacity three/four pole of any breaking capacity, single frame, fixed thermal magnetic trip at 415 volts in existing panels of booster pump houses including making connections by using suitable size copper lugs/thimbles and crimping tool complete, of replace in unsv MCCB old material should be deposited in AGE EM yard all as specified and directed by Engr in charge. |
| 150 | M&L for fixing/jointing, laying & testing for steel tubing galvanised medium grade with all fittings as per site requirment for any type, for jointing different type of pipes fittings also with pump and PVC water storage tank (tank inlet and outlet fitting include), for priming of pumps with new pipes for upgadation of system or in any required site as per direction of Engr-in-charge, laid in trenches or fixed to walls, ceilings or in floors complete for following sizes bore dia all as specified and directed by Engr-in-charge. |
| 151 | 15 mm bore dia |
| 152 | 20mm bore dia |
| 153 | 25mm bore dia |
| 154 | 40 mm bore dia |
| 155 | 50mm bore dia |
| 156 | M&L for fixing rotational moulded polythylene water storage tank 3 layer ISI Marked with lid cylindrical vertical with closed top hoisted mounted on staging /roof of OTM//Md Accn/pump house or as per directed by Engr-in-charge with proper foundation of following capacity in ltr, including dismantling and taking out old unserviceableservice over head tanks with necessary fittings and depositing in store yardof the Sub Division all as specified and directed by Engr-in-charge.Make-Sintex/Polycon |
| 157 | 1000 Ltr capacity |
| 158 | 750 Ltr capacity |
| 159 | S&F in repair 25 mm bore ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipeand fixed (Minimum weight142 gms) completeincluding taking out old / unserviceable ballvalve, completeallas specified and directed. |
| 160 | M&L for fixing of heavy duty Brass ball valve operated with anti-slip, anti-rusting premium stainless steel handle, 3 layer surface protection, screwed both ends for iron/GIIPVC pipe of following size, endurance to high pressure (600PSI water/oil/gas) including dismantling & taking out old unserviceable gate valvecomplete, all as specified & directed.Note : 1. Material required for jointing including cutting/screwing existing pipe/grinding/welding work/Earth work as reuqired include in quoted rate2. All T&P and vehicles for transpotation will be provide by contractor and no extra payment made out on this account. |
| 161 | 15 mm bore dia |
| 162 | 20 mm bore dia |
| 163 | 25 mm bore dia |
| 164 | 40 mm bore dia |
| 165 | 50 mm bore dia |
| 166 | M&L for fixing cast iron body sluice valve heavy duty class ‘PN-1.6’ of following mm bore, ISI marked with IS 14846, both flanged ends and drilled, high tensile stainless steel spindle, CI gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable CI sluice valve complete, all as specified & directed. Note : 1. Material required for jointing including cutting/screwing existing pipe/grinding/welding work/Earth work as reuqired include in quoted rate2. All T&P and vehicles for transpotation will be provide by contractor and no extra payment made out on this account. |
| 167 | 80 mm bore dia |
| 168 | 100 mm bore dia |
| 169 | 150 mm bore dia |
| 170 | M&L forfixing non return valve (NRV) of following size mm bore, cast iron body outer and Brass for internal components like the disc and connected items, as per IS 5312 (ISI marked), heavy duty, (PN-1.6), both ends flanged and drilled, including nuts, bolts, washer and neoprene rubber gasket joint complete all as specified and as directed including dismantling & taking out old unserviceable non return valve.Note : 1. Material required for jointing including cutting/screwing existing pipe/grinding/welding work/Earth work as reuqired include in quoted rate2. All T&P and vehicles for transpotation will be provide by contractor and no extra payment made out on this account. |
| 171 | 50 mm bore dia |
| 172 | 80 mm bore dia |
| 173 | 100 mm bore dia |
| 174 | 150 mm bore dia |
| 175 | Material and labour for repair/ re-construction of existing brick masonary valve pit chamber of size 1050x 1050 x 1050 mm (Internal dimension) using sub class ‘B’ bricks complete, earth work, PCC (1:4:8) type D-2 using 40 mm graded stone aggregate in foundation,brick masanary with sub class bricks 23 cm build in cement mortor with 1:6 plastering of 10 mm thickness internally and 15 mm externally in cement mortor 1:4 and below grond level PCC with 1:2:4 type B2 using 20mm grade stone aggregate ,coping 50 mm thick including frame of size 75x75x6mm made of angles iron and chamber cover made of MS sheet of 4 mm thicknessdouble leaf including MS hinges locking arrangement with provision of locks and keys , painting of the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer including necesarry excavation, returning & filling& removing of surplus soil including demolition of existing brickwork etc complete all asspecified and as directed by the Engineer in charge.Note : Earth work and all T&P as per site requirment is include in quoated rate. |
| 176 | Material and labour for repair/ re-construction of existing brick masonary valve pit chamber of size 1500x 1500 x 1500 mm (Internal dimension) using sub class ‘B’ bricks complete, earth work, PCC (1:4:8) type D-2 using 40 mm graded stone aggregate in foundation,brick masanary with sub class bricks 23 cm build in cement mortor with 1:6 plastering of 10 mm thickness internally and 15 mm externally in cement mortor 1:4 and below grond level PCC with 1:2:4 type B2 using 20mm grade stone aggregate ,coping 50 mm thick including frame of size 75x75x6mm made of angles iron and chamber cover made of MS sheet of 4 mm thicknessdouble leaf including MS hinges locking arrangement with provision of locks and keys , painting of the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer including necesarry excavation, returning & filling& removing of surplus soil including demolition of existing brickwork etc complete all asspecified and as directed by the Engineer in charge.Note : Earth work and all T&P as per site requirment is include in quoated rate. |
| 177 | M&L for replacement PVC insulated sheathed 3 core submersible flat cable for submersible pumps copper conductor cable (stranded) 1100 volt grade of size 10 Sq mm all as specified and directed by Engr-in-Charge. Make:- Plaza/finolex/ Havells |
| 178 | M & L for fixing contactor offollowing cap of motor including disconnecting and taking down old existing unserviceable contactor all as specified and directed by Engr-in-Charge. (All contactor should be deposited in store within 07 days after isuue of work order) Make:- L&T/C&S/Siemens. |
| 179 | Contactor rating suitable for 25 to 40 Amp, 3 Pole (MNX 32) or as per site for 20 HP motor. |
| 180 | Contactor rating suitable for45 to 65 Amp,3 Pole with (MNX 32) or as per site for 25/30 HP motor |
| 181 | Contactor rating suitable for 70 to 80 Amp,3 Pole with (MNX 50) or as per site for 40 HP motor |
| 182 | Contactor rating suitable for 85 to 100 Amp,3 Pole with (MNX 72) or as per sitefor 50 HP motor |
| 183 | M&L for Taking out UNSV selector switch and replace/fixing three way of three phase new selector switch for AC ammeter/Volt meter VN 63 Amp. |
| 184 | M&L for fixing of electronic type single phasing preventer in existing panel boards (max 600V min 380V) three phase 415 volts variation voltage 4% tripping time 2-5 sec max type VSP-1 complete all as directed by Engr in charge. Make:- L&T/Minilac/Siemens. |
| 185 | M&L for fix in replacement star delta timer range 0 - 30 second. Make : C&S/L&T /Schiender |
| 186 | Taking out of UNSV analogue Amp meter and supply and fix new digital ebrit panel mounted AC ammeter (0-300A) of size 96 X 96 sqmm flush mounted case three phase, class 0.5 item code PAMEBRITA 32. Make:-AE/HPL |
| 187 | Taking down UNSV phase indicator lamp supply and fix new phase indicator lamp (red, yellow & blue) |
| 188 | Taking out of UNSV analogue volt meter and supply and fix new digital ebrit panel mounted AC volt meter (0-500A) of size 96 X 96 sqmm flush mounted case three phase, class 0.5 item code PAMEBRITA 32. Make:-AE/HPL |
| 189 | M&L for fixing in replacement motor protection relay of following range in amp as per existing type/model with all connected accessories and deposite ols unsv material to store yard of AGE EM complete all as specified and directed by Engr-in-charge. |
| 190 | Range 13-20 Amp |
| 191 | Range 22-28 Amp |
| 192 | Range 30-40 Amp |
| 193 | Range 45-65 Amp |
| 194 | Range 70-120 Amp |
| 195 | M & L for preparation of old painted exposed surface of electric induction motor, NC verticale/horizontal, multi staging, centrifugal pump set of capacity upto 75 HP, with suction line from UG sump to pump set and delivery pipe line and outlet pipe line from pump set to wall/pit as observed inside pump house, operating valves ( Non return valves/sluice valves/Gate valves) any size by removing dust, dirt, oil, grease etc and painting with two coats of synthetic enamel paint of superior quality over one coat of red oxide as per existing colour or as appropriate colour using spray gun and writing SM/MES No to pump sets with white paint complete all as specified and directed by Engineer-in-charge.Make : Asian paint/Burger/NerolacNote : (i) Taking down and dismentling of connections and reinstallatiom is incl in quoated rate.(ii) Inner side cleaning of Suction and deliveryline and one coat of bitumen paint of boosterpumps incl in quoated Rate. |
| 196 | Taking down unsv ironchequered sheet /grill/chanel frame& supply and fix New iron chequered sheet of thickness not less than 6 mm/ grill/chanel frame with angle iron as per existing size including welding and two coat of black enamel paint over a coat of red oxide primer paint complete all as directed by Engr-in -Charge |
| 197 | Disconnecting the LT panelof any size and Cap andrepairof complete panel by taking out the cable ,Bus -bar , Voltmtr , Amp mtr ,including wiring and other minor parts (push button, indicators, etc), cleaning the complete accessories carefully. Minor repairs shall be rectified Parts/accessories shall be cleaned properly and refixing the parts at its original locations, checking and replace of the internal panel wiring with suitable size of wire and remove the carbon deposited inside the contact, cleaning all other spare parts all as directed by the Engineer-in-charge and reassembled after repair/replacement of required parts. |
| 198 | Supply and fix in replacement Earthing complete with galvanized iron earth plate electrode of size 60 cm x 60 cm x 0.60 cm buried directly in ground ( earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to the galvanized iron strip 32 x 6 mm as earthing lead by means of GI bolts/nuts/washers, protected by 15 mm bore GI light grade pipe from earth plate and upto 3 m along pole fixed with 2 clamps made from mild steel flat iron 25 x 3 mm bolts, nuts and washers etc. Earth plate shall be surrounded by packed layer of coal dust 300 mm and common salt 15 cm thick all around bottom and top, 20 mm GI light grade pipe for watering and including funnel, wire mesh, RCC 1:2:4 type B-1 using 20 mm graded stone aggregate cover of size 30 cm x 30 cm x 8 cm thick reinforced with expanded metal weighing not less than 4 kg/sqm, PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in earthing pit including necessary excavation and earth work, all as specified and shown in electrical plate No-3 of SSR Part-I and connected to earthing point and testing on completion.Note : PCC Chamber shall be constructed at least 1.5 m away from the earth electrode and pipe for watering shall be provided in slanting manners. |
| 199 | M&L for repair/renewal of name board with green acrylic radium sheet for pump house/ installation with suitable sheet of size 1.20 mtr x 0.90 mtr with existing stainless steel frame workincluding suitable size & shape of letters printed on both side with necessary earth work, PCC foundation etc including painting/framing work complete all as specified and directed.Note:- (i) Size and shape of letters and other things should be as per sample kept in AGE office sample room.(ii) The cost of above item deemed to be inclusive in qouted rates of this item. |
| 200 | De-watering the existing RCC semi underground water reservoir of 450000 Gallon capacity, cleaning all internal surfaces of roof, walls, & floors, all accumulated silt, mud, etc including grass, vegetation etc or any other deposited material inside the water reservoir including lifting the materials from the reservoir and getting out from the reservoir without any damage to reservoir including removing sludge, silt, mud, etc to a distance exc 50m but not exc. 250m from the outer edge of the reservoir and depositing where directed outside the reservoir, scrubbing with water using jute/bushes and washing the surfaces with mixture of bleaching powder & fresh water, finally washing the surfaces with fresh water and treating all internal surfaces with one coat of white wash complete and writing capacity of reservoir, date of cleaning & due date of next cleaning in thick synthetic enamel paint on outer surface of reservoir in block capital letters of height 25cm complete all as directed. |
| 201 | De-watering the existing RCC semi underground water reservoir of 525000 Gallon capacity, cleaning all internal surfaces of roof, walls, & floors, all accumulated silt, mud, etc including grass, vegetation etc or any other deposited material inside the water reservoir including lifting the materials from the reservoir and getting out from the reservoir without any damage to reservoir including removing sludge, silt, mud, etc to a distance exc 50m but not exc. 250m from the outer edge of the reservoir and depositing where directed outside the reservoir, scrubbing with water using jute/bushes and washing the surfaces with mixture of bleaching powder & fresh water, finally washing the surfaces with fresh water and treating all internal surfaces with one coat of white wash complete and writing capacity of reservoir, date of cleaning & due date of next cleaning in thick synthetic enamel paint on outer surface of reservoir in block capital letters of height 25cm complete all as directed. |
| 202 | Collecting raw water and treated water sample from UG Sump of Main Pump House respectively and testing of both for chemical and bacteriological analysis from Govt/NABL accredited laboratory monthly or whenever required or ordered by Engineer - in-Charge. Raw water and treated water from borewell and RO Plant respectively and testing of both for chemical and bacteriological analysis from Govt/NABL accredited laboratory monthly or whenever required or ordered by Engineer - in-charge.Note : PHED water testing and RO plant water testing considered in different jobs hence directed by Engr-in-charge. |
| 203 | M&L of Cast iron body Flow Water metersize 150mm , temperature upto 50 degree centigrade and 1000 liters per pulse class B IP 68 etc and testing, including dismantling & taking out old unserviceable CI sluice valve of 150 mm bore, complete all as specified & directed. |
| 204 | M&L MS gate framed work for main gate / OHT/UG or Semi UG Sumps ladder/Valve pit frame and pit cover such as using diffirent type of angles ,grills, grantings, etc. with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters , walk ways, railings, framwork of water tank and Including welding work etc ,similar work con-forming to Fe.290.Gde-E-165as per site requirement including PCC work and cement plasteringtarring and painting (where required) andsteel surface with two coat of synthetic enamel paint over a coat of red oxide prime including locking arrangement, welding, nuts, bolts etc as required complete including taking out old MS frame complete all as specified and directed by Engr-in-charge. |
| 205 | M&L for replacement ofstainless steel wire mesh of width upto 6 feet suitable on wooden frame for pump houses including drilling of holes with and including nuts, bolts and washers etc, as required,complete all as directed. |
| 206 | Supply aluminium ladder (heavy material, durable and resistant to rust and corrosion) of 8 mtr hight with maximum weight capacity and complete safety locks, non-slip feet, for cleaning and maintenance of sumps and OHT for daily maintenence all complete as specified and directed by Engr-in-Charge. |
| 207 | Excavation in trenches n exc 1.5 mtr wide and n exc 1.5m in depth for laying of water supply pipe line etc n exc 10 Sqm on plan and getting out soft/loose soil all as specified and directed by Engineer-in-Charge. |
| 208 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil all as specified and directed by Engineer-in-Charge. |
| 209 | Removing excavated material n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point all as specified and directed by Engineer-in-Charge |
| 210 | Taking up or down GI/cement/thin-walled/PVC/C-PVC/PP-R/HDPE any type tubing and connections from trenches, walls, floors, etc complete including cleaning serviceable pipe internally/externally for re-use, stacking properly in safe custody in storeyard of AGE E/M if relaying of pipe taken time due to valid reason and removing unserviceable pipe from site to AGE E/M Storeyard as Scrap material complete, all as specified and directed by Engineer-in-Charge for following size of pipes:-(Note :-Excavation and earth work shall be measured and paid separately) |
| 211 | 15 mm bore dia |
| 212 | 20mm bore dia |
| 213 | 25mm bore dia |
| 214 | 40 mm bore dia |
| 215 | 50mm bore dia |
| 216 | 80mm bore dia |
| 217 | 100mm bore dia |
| 218 | T&P and labour for laying, jointing & testing of GI/PVC/C-PVC/PP-R/any type in trenches/wall old serviceable steel water tubing (obtained from item No. 61.00 here-in-before) or recieved from Sch \"B\" items, galvanized, any grade with and including all new fittings in existing or new location,complete for following size bore dia all as specified and directed by Engr-in-Charge. Note :- Fittings shall be provided by contractor and cost of fittings deemed to be included in quoted rate for socket joints, together with all tube fillings (such as bends, elbows, tees, shortpieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, etc.) and fixing complete with clips, wall hooks, wooden plugs, or laying in trenches, etc., also for cutting, screwing and waste and for making forged bends on piping as required. Connectors shall be inserted, where required or directed. The rates also include cutting through walls, floors, etc. and their making good. |
| 219 | 15 mm bore dia |
| 220 | 20mm bore dia |
| 221 | 25mm bore dia |
| 222 | 40 mm bore dia |
| 223 | 50mm bore dia |
| 224 | 80mm bore dia |
| 225 | 100mm bore dia |
| 226 | M&L for laying/fixing steel tubing galvanised medium grade in repair/replacement against item No 61.00 here-in-before with all required fittings as per site requirment for any type, for jointing different type of pipes fittings also, including cutting, screwing and waste and for making forged bends on piping as required laid in trenches or fixed to walls, ceilings or in floors include cutting through walls, floors, etc. and their making good complete for following sizes bore dia all as specified and directed by Engr-in-charge. |
| 227 | 15 mm bore dia |
| 228 | 20mm bore dia |
| 229 | 25mm bore dia |
| 230 | 40 mm bore dia |
| 231 | 50mm bore dia |
| 232 | 80mm bore dia |
| 233 | 100mm bore dia |
| 234 | Taking up CI/DI/Cement/MS water main (including all fittings), with spigot and socketed ends jointed with run lead joints or rubber gasket (push-on) joint including burning out lead of joints and collecting run lead for re-use, cleaning serviceable pipe internally/externally for re-use, stacking properly in safe custody in storeyard of AGE E/M if relaying of pipe taken time due to valid reason and removing unserviceable pipe from site to AGE E/M storeyard as Scrap material, complete all as specified and directed by Engineer-in-Charge. |
| 235 | 80 mm bore dia |
| 236 | 100 mm bore dia |
| 237 | 150 mm bore dia |
| 238 | Laying/refixing only in trenches old serviceable CI/DI pipe any class(obtained from Ser item No 64.00 here-in-before) or recieved from Sch \"B\" items,with spigot and socketed ends, jointed with rubber tyton/run lead joints CI pipes and push-on joint with robber gasket for DI pipes, complete forfollowing dia bore complete for following dia bore pipe all as specified and directed by Engineer-in-Charge.Note :-(i)Excavation and earth work shall be measured and paid separately.(ii) Rate is inclusive for necessary welding/cutting work etc. as per site requirment no extra payment made out on this account.(iii) CI/DI fittings/specials shall be measured and paid separately under respective items here-in-after. |
| 239 | 80 mm bore dia |
| 240 | 100 mm bore dia |
| 241 | 150 mm bore dia |
| 242 | M&L for laying, jointing & testing of Ductile Iron (DI) pressure pipe of following bore (dia) with Spigot & Socket Ends, Centrifugally Cast (Spun) with Cement Mortar Lining in Inner Side confirming to IS : 8392 /2000 in standard length for classification K-7 and other relevant standards and Metallic Zinc Coating (130 gm/sqm minimum) and bituminous finish layer (minimum thickness 70 microns)followed by a finishing layer of Epoxy Paint in outer side, suitable for Push-on Joint (Rubber Gasket Joint) in any length and laid in Trenches with complete jointning material, complete all as specified and as directed by Engr-in charge.Note :-Excavation & earthwork, DI fittings / specials & joints shall be measured & paid for separately under relevant items of this Schedule.Make : Electrosteel / Jindal/Kesoram.Note : (i) Rates quoted by tenterer includingjointing material like Rubber tyton/push on joint ring/as per site requirment, including necessary welding/cutting work etc.(ii) CI/DI fittings shall be measured and paid seperatly respective items here-in-after. |
| 243 | 80 mm bore dia |
| 244 | 100 mm bore dia |
| 245 | 150 mm bore dia |
| 246 | M&L in replacement rubber gasket tyton joint (push on joint) including rubber ring of following size suitable for CI/DI pipe lines of following dia bore. |
| 247 | 150 mm dia |
| 248 | 100 mm dia |
| 249 | 80 mm dia |
| 250 | M&L for Finding and Repair/rectification of water supply pipe line (any type) against day to day maintainence complaints like leakage/blockage/no water supply, on wall/floors including replacement of items like union,elbow ,socket ,tee and reducer Tee/socket/elbow, (all GI/PVC/PP-R Fittings as per site requirmnet for any type of pipe like GI, Cement, HDPE, PP-R, Thin-walled, etc) as per site requirement for size of following dia complete all as specified & directed by Engineer-in-Charge.Note- (i) Rates quoted by tenderer incl taking up or down of lines for repair, cleaning of serviceable pipe internally/externally for re-use and refixing after repairing complete including cutting/screwing existing pipe/grinding/welding work as reuqired complete. (ii) Rates quoted by tenderer incl excavation, returning& filling,removing soil andmaking gooddisturbed surface on both side, Dewatering from trenches and taking out of mude etc with the help of JCB or mud pump as required at site andtaking out of broken/cracked pipe including welding work as reuqired complete. (iii) Rates quoted by tenderer incl labour cost for finding/tracing the exact issue regarding complaint and complete rectification. (iv) Complete site cannot be handed over to contractor, site of leakage/blockage/no water supply as per complaint received by user is only handed over the contractor on site requirment basis.(v) Contractor/supervisor will collect complaints from concern JE or MCM on daily basis befor 1045 hrs and rectify within 12 hours, if leakage found again during the contract period at same location contractor will repair it again and no extra payment will be made on this account.(vi) Acceptance of the repair work by user/occupent is obtained duly signed and submitted at the complaint cell. |
| 251 | 15 to 20 dia mm bore. |
| 252 | 25 to 32 dia mm bore. |
| 253 | 40 dia mm bore. |
| 254 | 50 dia mm bore. |
| 255 | M&L for Finding and Repair/rectification of water supply pipe line (any type) against day to day maintainence complaints like leakage/blockage/no water supply, in trenches includingreplacement of GI items like union,elbow, socket, tee, reduceretc(all GI/PVC/PP-R/any type of fittings (except CI/DI fittings) as per site requirmnet for any type of pipe like GI, Cement, HDPE, PP-R, Thin-walled/CI/DI etc), as per site requirement ,size of pipe following dia complete all as specified & directed by Engineer-in-Charge.Note- (i) Rates quoted by tenderer incl excavation (upto length 30mtr and depth upto 1.50 mtr), returning& filling, removing soil and making gooddisturbed surface on both side, Dewatering from trenches and taking out of mude etc with the help of JCB or mud pump as required at site and taking out of broken/cracked pipe, taking up or down of lines for repair, cleaning of serviceable pipe internally/externally for re-use and refixing after repairing complete including cutting/screwing existing pipe/grinding/welding work as reuqired complete. (ii) CI/DI fittings/specials shall be measured and paid separately under respective items here-in-after. (iii) Run lead joints/rubber gasket joints measured and paid seprately under relevent items. (iv) Rates quoted by tenderer incl labour cost for finding/tracing the exact issue regarding complaint and complete rectification. (v) Complete site cannot be handed over to contractor, site of leakage/blockage/no water supply as per complaint received by user is only handed over the contractor on site requirment basis. (vi) Contractor/supervisor will collect complaints from concern JE or MCM on daily basis befor 1045 hrs and rectify within 12 hours, if leakage found again during the contract at same location contractor will repair it again and no extra payment will be made on this account. |
| 256 | 15 to 20 mm bore dia. |
| 257 | 25 to 32 mm bore dia. |
| 258 | 40 mm bore dia. |
| 259 | 50 mm bore dia. |
| 260 | 80 mm bore dia. |
| 261 | 100 mm bore dia. |
| 262 | 150 mm bore dia. |
| 263 | M&L for repair to existing leaking run lead joint/ repair of new leakge with run lead joint of CI/DI pipe or fittings of following bore spigot and socketed ends by dismantling joint by melting the lead with the help of burner/blower including taking out complete existing lead and old spun yarn and re-jointing with additional quantity of Pig lead as per required and good quality of spun yarn and testing of joint including cutting of pipe line, jointing necessary, excavation & earth work in any type of soil including dewatering complete etc, for following dia bore pipe all as specified and directedby Engr-in-charge. |
| 264 | 80 mm bore dia |
| 265 | 100 mm bore dia |
| 266 | 150 mm bore dia |
| 267 | M&L in repairs cast iron detachable joint with rubber ring, ISI marked, Class-A, suitable for following bore GI/CI/DI pipe specials with nuts, bolts including necessary excavation & earth work in any type of soil excluding dewatering complete all as specified & as directed. |
| 268 | 40/50 mm bore dia. |
| 269 | 80 mm bore dia. |
| 270 | 100 mm bore dia. |
| 271 | 150 mm bore dia. |
| 272 | M&L for cutting/dismantling of PCC hardstanding / WBM road with soling & premix carpet of any description for repair/replacement of water supply pipe lines and disposal of debris & rubbish to a distance exc 250m but not exc 500m and making good the same with & including plain cement concrete 1:2:4 type B1 (using 20mm graded crushed stone aggregate) as existing depthcomplete all as specified & directed by Enge-in-charge. |
| 273 | Material and labour for jointing/fixing of CI/DI fittings (ISI marked) 80 mm to 600 mm bore such as bends (any type, radius & angle), Tapers any type (straight, bend, increasing, decreasing or double socket etc), Tee pieces, single branch, “Y” junction, double branch, cross (all sockets or socket & spigot), collars, caps & plugs suitable for spigot & socketed pipes, complete, fixed in repairs, all as specified & directed.Note :- (Earth work & lead joints will be paid & measured separately respective item of Sch) &Joints shall be measured and paid for separately. |
| 274 | M&L mild steel clamps made of flat iron 40x6 mm in two halves for tapping through 40 to 80 mm bore GI/DI water pipe line including drilling and welding of 15/20/25/40/50mm GI socket and necessary rubber insertion, nut, bolts & washers complete all as directed. |
| 275 | M&L mild steel clamps made of flat iron 50x6 mm in two halves for tapping through 100 to 200mm bore GI/DI water pipe line including drilling and welding of 15/20/25/40/50mm GI socket and necessary rubber insertion, nut, bolts & washers complete all as directed. |
| 276 | M&L for repair to unserviceable Air Release Valve of outlet 80 mm/100 mm by opening the outlets and refixing the same after complete repair such as nut bolts, rubber gasket, ball and any other material , welding works as rquired including testing the valve, all as specified & directed by the Engineer-in-Charge. |
| 277 | M & L for PCC 1:4:8, type D-2, (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 278 | Surface dressing/ cleaning /excavation of area around the installations, valve pit chambers, path of installations & valve pits etc not exceeding averaging depth 15 cm in soft/loose soil complete all as specified and directed by Engr-in-Charge. |
| 279 | M&L for opening the gland cap from both side of sluice vale (fixed other than Pump houses premises) in supply lines at kanasar station and taking out the rusted gland dori and refilling the new gland dori with grease both side of sluice valve and refixing the gland cap in same position complete all as specified and directed by Engr-in-Charge. |
| 280 | Supply & Fixing in replacement Cast iron air release valve with two air outlets 80 mm bore and fixing up in cast iron water supply mainsall as specified and directed by Engr-in-charge including |
| 281 | De-watering the existing RCC over head water tank of 20000 Gallon capacityat 60 feet staging and cleaning all internal surfaces of roof, walls & floor to remove scales, mud & other foreign material, scrubbing with water using jute/bushes and washing the surfaces with mixture of bleaching powder & fresh water, finally washing the surfaces with fresh water and treating all internal surfaces with one coat of white wash complete and writing capacity of reservoir, date of cleaning & due date of next cleaning in thick synthetic enamel paint on outer surface of reservoir in black capital letters of height 25cm complete all as directed and consist of following cleaning process : DEWATERING : Dewatering of the water tank.SLUDGE REMOVAL : Removing of any type of sludge, accumulated mud, silt, sand, vegetation growth or any solid particles etc. from bottom surface and inner walls of tank with the help of sludge pumps or manually disposing off the same to a distance exceeding 50 mtrs but not exceeding 100 mtrs away from the fencing/boundary wall of installation, and spreadingin low lying areas.ALGAE REMOVAL : Removal of Algae, Calcinations etc from the walls with rotary cleaner/scrubber machine/wire brushes etc.INTERNAL WASHING : Washing of Walls and Ceiling with the help of high pressure jet cleaners using Sodium hypo chloride/Altoch mixed water (using 05% by Volume)ANTI-BACTERIAL TREATMENT : Walls and ceiling to be sterilized with Anti Bacterial Solution (using 15 % by Volume of H2O2/silver ion) for making it bacteria free.VACUUM CLEANING : Complete removal of remaining sludge, accumulated mud, silt, sand with the help of vacuum cleaners.UV TREATMENT : Tank to be sterilized and disinfected with the help of UV lamp for min 01 hr to make bacteria free. |
| 282 | De-watering the existing RCC Semi UG Sump of capacity 150000 Gallon capacityat any staging and cleaning all internal surfaces of roof, walls & floor to remove scales, mud & other foreign material, scrubbing with water using jute/bushes and washing the surfaces with mixture of bleaching powder & fresh water, finally washing the surfaces with fresh water and treating all internal surfaces with one coat of white wash complete and writing capacity of reservoir, date of cleaning & due date of next cleaning in thick synthetic enamel paint on outer surface of reservoir in black capital letters of height 25cm complete all as directed and consist of following cleaning process : DEWATERING : Dewatering of the water tank.SLUDGE REMOVAL : Removing of any type of sludge, accumulated mud, silt, sand, vegetation growth or any solid particles etc. from bottom surface and inner walls of tank with the help of sludge pumps or manually disposing off the same to a distance exceeding 50 mtrs but not exceeding 100 mtrs away from the fencing/boundary wall of installation, and spreadingin low lying areas.ALGAE REMOVAL : Removal of Algae, Calcinations etc from the walls with rotary cleaner/scrubber machine/wire brushes etc. INTERNAL WASHING : Washing of Walls and Ceiling with the help of high pressure jet cleaners using Sodium hypo chloride/Altoch mixed water (using 05% by Volume)ANTI-BACTERIAL TREATMENT : Walls and ceiling to be sterilized with Anti Bacterial Solution (using 15 % by Volume of H2O2/silver ion) for making it bacteria free. VACUUM CLEANING : Complete removal of remaining sludge, accumulated mud, silt, sand with the help of vacuum cleaners.UV TREATMENT : Tank to be sterilized and disinfected with the help of UV lamp for min 01 hr to make bacteria free. |
| 283 | De-watering the existing RCC Semi UG Sump of capacity 50000 Gallon capacityat any staging and cleaning all internal surfaces of roof, walls & floor to remove scales, mud & other foreign material, scrubbing with water using jute/bushes and washing the surfaces with mixture of bleaching powder & fresh water, finally washing the surfaces with fresh water and treating all internal surfaces with one coat of white wash complete and writing capacity of reservoir, date of cleaning & due date of next cleaning in thick synthetic enamel paint on outer surface of reservoir in black capital letters of height 25cm complete all as directed and consist of following cleaning process : DEWATERING : Dewatering of the water tank.SLUDGE REMOVAL : Removing of any type of sludge, accumulated mud, silt, sand, vegetation growth or any solid particles etc. from bottom surface and inner walls of tank with the help of sludge pumps or manually disposing off the same to a distance exceeding 50 mtrs but not exceeding 100 mtrs away from the fencing/boundary wall of installation, and spreadingin low lying areas.ALGAE REMOVAL : Removal of Algae, Calcinations etc from the walls with rotary cleaner/scrubber machine/wire brushes etc.INTERNAL WASHING : Washing of Walls and Ceiling with the help of high pressure jet cleaners using Sodium hypo chloride/Altoch mixed water (using 05% by Volume)ANTI-BACTERIAL TREATMENT : Walls and ceiling to be sterilized with Anti Bacterial Solution (using 15 % by Volume of H2O2/silver ion) for making it bacteria free.VACUUM CLEANING : Complete removal of remaining sludge, accumulated mud, silt, sand with the help of vacuum cleaners.UV TREATMENT : Tank to be sterilized and disinfected with the help of UV lamp for min 01 hr to make bacteria free. |
| 284 | Notes for Ser Item No 51.00, 52.00, 81.00, 82.00 & 83.00(i) The mixture of bleaching powder & water for cleaning shall be prepared by mixing 250 gm of bleaching powder in 10 litres of fresh water.(ii) All inlets/outlets/over flow/wash out connections shall be cleaned. Any leakage in joints shall be made good as directed and quoted rate also includes this aspect.(iii) The existing water, water used for cleaning etc shall be bailed out at the nearest open drain available.(iv) Any damage occurred to the assets during cleaning etc shall be made good by the contractor at his own cost.(v) All protective & safety measures for workmen against Honey Bee, insects, creatures, gases, height etc shall be responsibility of the contractor. The quoted rate shall be deemed to include for this provision.(vi) The contractor must carried out all the process in such a way that the complete inside cleaning process as mentioned above must be finished instipulated time decided by Engineer-in-charge to produce minimum disturbance to regular water supply to connected area. If contractor fails to restore the water supply within stipulated time, as decided by Engineer-in-charge, the penal recovery of Rs - 2000.00 per day will be recovered from contractor\"s dues. (vii) All the equipment/material required for cleaning of tank / sump will be brought by the contractor and no extra cost will be paid in this effect. |
| 285 | Demolition of old brick work of valve pit of different size and M&L for brick work with sub class ‘B’ old size bricks, built in cement morter 1:6 complete all as specified and directed by Engineer-in-Charge. |
| 286 | M&L for cement plaster 10mm thick in cement mortar 1:4 finished even and smooth without using extra cementon brick masonry or concrete surfaces of walls ofvalve pit chamber complete all as specified and directed by Engineer-in-Charge. |
| 287 | M&L for painting ofexisting Steel/RCC surface with one coat of Black/Blue/Yellow colour synthetic enamelled paint including preparation of surfaces complete all as specified and directed by Engineer-in-Charge. |
| 288 | M&L for writing letters or figures (Block, Roman, Italic or Indian) not less than 35 mm high with synthetic enamel paint on existing steel/ RCC wall surface with synthetic enamelled paint complete all as specified and directed by Engineer-in-Charge. |
| 289 | M&L for disconnecting suction/delivery lines and coupling, taking down from their location including dismantling of Vertical High Presure pump set ofcapacity 20 HP and replacement of worn out spare parts and re-assembling, installation in same location,commissioning & testing complete all as directed.Notes:- (i) The spare parts required to be replaced shall be measured and paid for separately as \"Supply only\" under the relevant item here in after.(ii) Unit rate shall be deemed to include for all minorspares/extras. |
| 290 | Supply only the following spare parts forVertical High Presure pump set ofcapacity 20 HP against serial item No. 88.00 here in before as per existing make .Note :- All spare parts shall be fixed in the pumps only after prior inspection & approval of Engineer-in-Charge |
| 291 | SS shaft suitable for Vertical High Presure pump set of 20 HP. |
| 292 | Top diffuser/chamber suitable for Vertical High Presure pump set of 20 HP. |
| 293 | Bottom diffuser/chamber suitable for Vertical High Presure pump set of 20 HP. |
| 294 | Impeller suitable for Vertical High Presure pump set of 20 HP. |
| 295 | Carbide TC Bush suitable for Vertical High Presure pump set of 20 HP. |
| 296 | Mechanical Cartridge Seal suitable for Vertical High Presure pump set of 20 HP. |
| 297 | Plain Diffuser suitable for Vertical High Presure pump set of 20 HP. |
| 298 | Carbon Diffuser suitable for Vertical High Presure pump set of 20 HP. |
| 299 | Supply and mixing (day to day operation) NSF certified food grade RO antiscalant for effective in controlling deposition of organic/inorganic scalants and such as calcium carbonate, calcium sulphate, Barium sulphate, strontium sulphate, calcium flouride, iron, colloidal material, silica and other organic contaminants. Antiscalant should be effective over a wide pH range. |
| 300 | Supply and fix in replacement superior quality micro filterjambo of existing size 6inch/24 inch or as per existing filter complete all as specified and directed by Engineer-in-Charge. |
| 301 | Supply and fix in replacement rotameter/flowmeter suitable for RO Plant of capacity 10000 Ltr/Hour as existing in RO panel or Raw water line complete all as specified and directed by Engineer-in-charge. |
| 302 | Cleaning of water tank 50000 ltrs at RO plant, removing sludge / sand / dirt by means of manual / sludge removing pump, cleaning the sumps with bleached water and washing with sodium hydrochloride liquid, drying and applying one coat of lime wash internally and spraying anti bacteria liquid, writing date of cleaning on outer wall of sump with white paint on black base for following capacity of sumps (Note - (i) Sludge / sand / dirt shall be disposed off from the sump at a distance beyond 150 m as directed by Engineer-in- Charge ). (ii) Cost of all T&P such as ladder etc is deemed to be included in rate quoted. |
| 303 | Supply and fix in replacement CPVC pipe 50 mm dia ISI marked including fittings such union, elbow, tee, sockets, reducer and contoll valve etc,resistant to corrosion,can withstand high pressure including cutting, jointing and testing satisfactorily as per existing including taking down old one complete all as specified and directed by Engineer-in-Charge. |
| 304 | Supply and fix in replacement anti scaling dosing pump as per existing size and capacity installed at RO Plant complete all as specified and directed by Engineer-in-Charge. |
| 305 | Supply and fix in replacement low pressure cut out switch as per existing installed at RO Plant complete all as specified and directed by Engineer-in-Charge. |
| 306 | Supply and fix in replacement high pressure cut out switch as per existing installed at RO Plant complete all as specified and directed by Engineer-in-Charge. |
| 307 | Supply and fix in replacement Multi port valve as per existing installed at RO Plant complete all as specified and directed by Engineer-in-Charge. |
| 308 | Supply and fix pressure guage assembly 0 to 100 Psi or 7 kg/cm2 as per existing installed at RO Plant including taking down old one all as per specified and directed and Engr - in - charge |
| 309 | Supply and fix in replacement thin film composite (TFC) polyamide 8040 RO membrane in 400 Sqft surface area as existing suitable for RO plant of capacity 10000 Ltr/Hr complete including all fitting such as end caps, end cap overrings, end connector & overrings, metal lock rings, metal strap & support complete all as specified and directed by Engineer-in-Charge. Make :- LG/Hydronautics/Toray/Lon Exchange |
| 310 | Opening completely Activated carbon filter use in RO plant capacity 10000 LPH and taking out existing filter media and nozzles, removing filter media to a distancenot exceeding 50 mtr and nozzles to MES store yard including necessary repair/welding to make the filter vessels completely leak proof for improving strength and finally reassembling the filter including re-fixing the old serviceable nozzles in position duly cleaned and replacing all activated carbon (8 Bags approx) complete all as specified and directed by Engineer-in-Charge. |
| 311 | Opening completely sand filter use in RO plant capacity 10000 LPH and taking out existing filter media (sand, gravels) and nozzles, removing filter media to a distancenot exceeding 50 mtr and nozzles to MES store yard including necessary repair/welding to make the pressure filter vessels completely leak proof for improving strength and finally reassembling the pressure filter including re-fixing the old serviceable nozzles in position duly cleaned and replacing all sand & Media filter (10 units approx) complete all as specified and directed by Engineer-in-Charge. |
| 312 | M&L for fixing of Filter housing (jumbo housing PVC heavy material) fit for 4 units (1.5\" x 4\" x 20 \") with complete SS frame including taking down carefully old housing of any type complete all as specified and directed by Engineer-in-Charge. |
| 313 | M&L for complete set of UV light with outer cover all as per site requirment complete all as specified and directed by Engineer-in-Charge. |
| 314 | M&L for replacing of 50mm dia valve of waste water line with 50mm SS valve including taking down old unsv valve carefully without damaging any parts of plants all as specified and directed by Engr-in-Charge.Note : Cutting/screwing/welding include in quoted rate. |
| 315 | M&L for replacing of distribution system of filters (media and Carbon) upper and down side with complete all as specified and directed by Engr-in-Charge. |
| 316 | Cleaning of PVC water tank 4 x 5000 ltrs (considering as one Job) at RO plant, removing sludge / sand / dirt by means of manual / sludge removing pump, cleaning the Tank with bleached water and washing with sodium hydrochloride liquid, drying and applying one coat of lime wash internally and spraying anti bacteria liquid, writing date of cleaning on outer wall of Tanks with white paint on black base all as specified and directed by Engr-in-Charge.(Note - (i) Sludge / sand / dirt shall be disposed off from the Tank at a distance beyond 150 m as directed by Engineer-in- Charge ).(ii) Cost of all T&P such as ladder etc is deemed to be included in rate quoted. |
| 317 | M & L for name board with green acrylic radium sheet for pump house/installation with suitable sheet of size 1.20 mtr x 0.90 mtr with suitable stainless steel frame workwith pedestal of dimension 2.5 mtr x 1.20 mtr, 40 mm dia stainless steel rod including suitable size & shape of letters printed on both side with necessary earth work , PCC foundation etc including painting/framing work.Note :- (i) Size and shape of letters and other things should be as per sample kept in AGE office sample room.(ii) The cost of above item deemed deemed to be inclusive in rates. |
| 318 | M&L for periodically (one months of calender year or as per ground requirment) thorough inspection of all components, cleaning/replacement of pre-filter and membrane cleaning (replacement depending on water quality and use), checking of leakage, inspecting tubing & fittings, complete cleaning internal and exterior of plant, examinethe pressure gauge, pumps & other mechanical components for any unusyal wear/damage, check and cleaning of sand and activated carbon filter for proper functioning & quantity of material, inspection & clening/replace micron filter/memrane, RO plant performance, verifying antiscalant dosing system and replenish the same, inspecting high pressure pump & ensure it is operating within the specified parameters, checking all electric panels for any sign of overheating or loose connection and resolving all issues/faults with servicing complete as required for improvement of plant. including material and labour for made 1 x deep whole in backside of RO plant for wast water and distribute to different small chanels in green areas, the dept should be finalised by Engr-in-charge all complete all as specified and directed by Engr-in-charge.Note : (i) Servicing of RO plant done by authorised and experienced providers. (ii) All replacement items are paid in sch A items seperately. (iii) servicing contains all plant accessories hence grasing/cleaning/gland filling or any requried action is include and no extra payment made on same account. |
| 319 | Note : (for all items of BOQ excluding comprehensive job)(i) All items considered in work for repair and maitenance at entire location of Mil Station Kanasar. No extra cost for repair /replacement/transport of GI/DI/CI/any type of pipe and connected items of pipe at any location inside station.(ii) Complete site cannot be handed over to contractor, site of leakage/blockage/no water supply as per complaint received by user is only handed over to the contractor on site requirment basis.(iii) All T&P and vehicles for transpotation will be provide by contractor and no extra payment made out on this account. (iv) All type of complaints against water supply pipe lines, pump motors and RO plants shall be rectified by the contractor within 12 hrs from the launch of complaint time through complaint slip/ teliphonically/messaging. If contractor fail to rectified the above said complaint in given time period then a penalty @ Rs 200/day will be recovered agaist the each job. (v) Contractor Shall provide required manpower with all required tools/equipments for attending emergency complaint for 24 hours no extra payment made out on this account. (vi) Quoted rate deemed to be inclusive of all labour, equipment and T&P material/arrangment to attend the day to day maintenance complaint on daily basis .(vii) Contractor shall update daily executed work on daily basis with sign of user on complaint slip (maintaining work done register) to concern JE E/M.(viii) Rates quoted by tenderer incl finding/tracing exact issue of daily complaint for any size of pipes, and after rectification same will be measured in as per size of pipe on site in as per job. During repair/maintenance site cleaning is required the rate for same inclusive in quoted rates.(ix) Old unsv material recived against new laid pipe/Sluice valve/NRV (All old unsv material any type) etc may transport and deposited to AGE E/M store yard by contractor as per directions of Engr-in-charge. (x) Contractor should collect complaint slip on daily basis prior to 0930 to 1030 hrs without fail and deposite the same after rectification within time period of 12 hrs, if contractor fail to deposite complaint slip with occupant sign with date, then consider as delay in rectification period which leads to recovery as per Rs 200/day. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail