| 1 | M&L Boring holes through stone for pipes, etc. n exc 50 mm dia and making good complete all as specified and directed. |
| 2 | M&Lin repairs Pre-cast PCC 1:3:6 type C1 (20 mm graded stone agg) cement concrete block masonry with solid blocks exc. 10cm in width and set in cement mortar 1:6 including demolition of old brick work / stone masonry/PCC block built in cement mortar of any description as specified and directed. |
| 3 | M&L for cement plaster rendering 10mm thick in CM 1:6 on fair faces of brickwork or concrete surface as on wall finished even and smooth without using extra cement and taking down old cement plaster on brick or stone walls, or concrete walls etc., hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises complete all as per specified and directed. |
| 4 | M&L for cement plaster rendering 5mm thick in CM 1:3 on fair faces of brickwork or concrete surface as on ceiling finished even and smooth without using extra cement and taking down cement plaster on ceilings surface etc., hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises complete all as per specified and directed. |
| 5 | M & L for preparation of newly plastered surfaces of wall and applying two coats ofoil bound distemper (OBD) over a coat of primer complete all as specified and directed. |
| 6 | M & L for preparation of newly plastered surfaces of ceiling and applying three coats of white washcomplete all as specified and directed. |
| 7 | S&F in repair 15mm bib taps, fancy type chromium platedwith crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 8 | S&F in repair 15mm angle cock with flange cast copper alloy, chromium plated, fancy type, screwed both ends for iron pipe or for union complete all as specified and directed. |
| 9 | S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 10 | S&F in repair waste pipe of dia 32/40mm fixed into basins, sink etc complete all as specified and directed. |
| 11 | S&F in repairs 15 mm bore Pillar taps, cast copper alloy, with capstan heads, chromium plated fancy type, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed. |
| 12 | S&F in repairs, 10 litre capacity PVC flushing cistern, syphonic action type, low level, white, with inlet, ball valve,pvc flush pipe, float and handle incl brackets and waste pipe complete all as specified and directed. |
| 13 | S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 meter long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed. |
| 14 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations complete all as specified and directed. |
| 15 | M&L 18 to 20mm thick Granite slab (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including dismantling of old granite/cudappa stone of any description all as specified and directed. |
| 16 | M&L Providing and applying wall care putty of 1mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed. |
| 17 | M&L Preparation of old plastered surfaces by complete removal of existing treatment from wall and applying two coats of oil emulsion distemper on wall surfaces complete all as specified and directed. |
| 18 | M/L Preparation of old plastered surfaces and applying three coat of white wash on ceilings incl complete removal of existing treatment complete all as specified and directed. |
| 19 | Preparation of old surafece of wall and applying a coat of 3mm thick wall care putty and two coats of oil bound distemper complete all as specified and directed |
| 20 | Supply & fixingfactory made WPC single extruded 100% lead free ISO certified board of 18mm thick pre laminatedBoth side shutter for Kitchen/Room cupboard. The laminated shutter shall be of 0.14 micron prelaminated both side with different design and density not less than 700 kg / cum manufactured by an ISO 9001:2015 certified company. The 18mm board will be water proof, termite proof and borer proof and shall have good screw holding capacitycomplete all as specified and directed. Make-Black Kobra or Equivalent |
| 21 | S & F SS auto closing hinges 35mm length 8 crank bright finish fixed to CB incl screws, plugs etc all as specified and directed |
| 22 | S&F 100 mm SS Handle fancy type fixed in cupboard shutter all as specified and directed. |
| 23 | M&L Preparation of old wooden surfaces of any description over 10cm width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 24 | S&F in repair 22-25mm dia SS curtain rod incl SS brackets of any type, holder fixed into brick/stone wall with screw,plugs etc all as specified and directed. |
| 25 | S&F 8 feet 4 pipespulley operatoed cloths drying system consisting of aluminium pipe of outer dia 22mm, inner dia 19.80mm,made up of detrin with rope guide mounted on channel pair of lemgth 24 feet (distance between two pipes is adjustable) locking system to hide rope knot, channel to be mounted or fixed with self taping screws provided in kit. Rope will be HDPE double core of 4mm dia fixing to ceiling as specified and directed by Engr-in-Charge and minimum weight of one pipe shall not be less than 0.20kg/mtr, minimum weight of rope shall not be less than 7700Gms/unit . |
| 26 | S&F Powder coated anodised aluminium frame for doors, windows, ventilators and partition with one or more rebates including joining cleat and all accessories for fixing etc (miniumum thickness of powder coating 50 micron) complete all as specified and directed. |
| 27 | S&F Powder coated anodised aluminium door shutters, aluminium section weighing not less than 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws and all accessories etc. (minimum thickness of powder coating 50 micron) complete all as specified and directed. |
| 28 | S&F Door closer hydraulically regulated,designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed. |
| 29 | M&L 12mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to Aluminium frame work complete all as specified and directed. |
| 30 | S&F Mortice lock, vertical type, size 100mm aluminium 4 Levers complete all as specified and directed. |
| 31 | S&F 6 mm thick toughened heat and dust absorbing glass any size ,fixing in aluminium frame or similar works etc as per manufacture instruction complete all as specified and directed. |
| 32 | S&F 18/19mm thick block boardsgrade 2 quality, interior grade, decorative type with decorative face veneer on both face, fixing with wall and ceiling etc complete all as specified and directed. |
| 33 | Material and labour for modular workstation, comprising of (overall dimension of the workstation : 1500mm Length X 1200mm Width X 1200mm Height as shown in the drawings) 50 mm Thick Tile Based MS frame with aluminium Trim Partition of 1200mm Ht. with powder coating finish. (Grommet Holeabove the table top), 50mm thick frames made out of MS CRCA sheet of thickness 1.00 mm with powder coated and top, sides fixed with aluminium trims and junctions with PVC caps along with 25mm thick BSL PLPB Gable end above table top provided with 9mm fabric or writing tile on outer side and inner side of workstation. below the table top bottom tiles finished with 9mm Prelaminated tiles with approved colour. LEG (MS powder coated 40mm square tube leg of 1.60 mm thickness), SKIRTING (To have MSpowder coated skirting as per the company standard), Table Top (Table top made out of 25mm thick prelaminated particle board of width 600mm with 2mm thick PVC edge band finished as approved) Computer Key Board with suitable tray fixed with screws to telescopic channel of suitable size (PVC Key Board Tray mounted below the table top),All the members connected to each other by means of stainless steel cleats/fixed with brass screws etc Pedestal with 2D1F drawers :- (Product Dimensions: 600mm(H)x400(L)x450(D) Primary Material: 18mm Engineered wood with 2mm machine edge banding Drawers: 2 Equal drawer 1 File drawer with 1 lock), fixedwith screws to telescopic channel of suitable size , 75mm Stainless Steel Handles complete all as specified and directed. |
| 34 | Supply and fixinganodised alunimun size 605 x 605 mm snap grid frame work for false ceiling as per manufacturer instructions, with Hangers of GI wire of suitable size (up to 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long andincluding 6-8 mm thick gypsum boards designer tiles, fixed to sheet suitably placed in false ceiling grid made of aluminium/G.I./ M.S. as per specification and drawing complete all as specified and directed. |
| 35 | M&L for 18/19mm thick veneered particle boards exterior grade,solid core, general purposes type, with face veneers of type \"BB\", fixed with screws to timber frame work complete all as specified and directed. |
| 36 | S&F in repair 18/19 mm thick ,water proof plywood , fixed to Cupboard work in any position with nails including removal of old boards of any description complete all as specified and as directed. |
| 37 | S&F decorative laminates of 0.90 mm thick type matt finish, fixed with adhesive colour and pattern as approved including taking down existing one complete all as specified and as directed. |
| 38 | S&F Magnetic catches with 8mm dia steel ball and brass body and striking plate including taking down existing one complete all as specified and directed. |
| 39 | S&F PVC beading for cupboard work, colour and pattern as approved including taking down existing one complete all as specified and as directed |
| 40 | S&F Stainless steel spring hinges of suitable size and of approved pattern and make suitable for base/wall unit of modular kitchen including taking down the existing one complete all as specified and directed. |
| 41 | S&F Stainless steel handles of size 150 mm of approved pattern and make suitable for Base/Wall unit of modular kitchen including taking down the existing one complete all as specified and directed. |
| 42 | M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn into and including rigid non mettalic PVC conduit/casing caping medium grade not less than 19/20 mm ( ISI marked ) with all fitting and fixing accessories including sunk in pressed steel chromium plated terminal boxes, concealed/surface in wall/roofs/floor/ceiling etc as per site requirement and making & matching the existing surface ) white bakelite sheet cover for mounting switches, Sockets, Fan regulators etc or modular cover plate with frame including sunken boxes suitableto fix modular cover plate with frame , concealed in wall and 1.5 sq mm multi stranded copper conductor cable as continuous earth wire drawn with wiring and connected to common earth dolly complete all as specified and directed for the following :- Make of wire: Polycab/Plaza/HavellsNote:Blanking plate,Modular cover plate ,Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely). |
| 43 | All as per item No. 42 here in before but for one light point/fan point controlled by one wayswitch. |
| 44 | All as per Sl No. 42 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently complete all as specified and directed. |
| 45 | Supply and Fixmodular switch1 way 6 Amp.1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 46 | Supply and Fixmodular switch1 way 16 Amp.1 module, complete all as specified and directed. Make :Legrand/ Crabtree/ Anchor /Indoasian |
| 47 | Supply and Fix modular Socket, 16A - 3/5 pin combined 2 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 48 | S & F ceiling rose 3 phase/PVC/polycarbonate, isolated body complete all as specified and directedMake : Anchor/Havells/L&T |
| 49 | Supply and fix White cover plate with frame,2/3 module |
| 50 | Supply and fix White cover plate with frame,4 module |
| 51 | M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 Sqmm drawn through in and incl suitable size concealed/surface PVC casing caping/PVC Conduit and all accessories fixed to wall/floors along with 6 Sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and directed.Note: (a)2 runs of 6 Sqmm cable along with one run of 6 Sqmm cable for earth conductor shall be measured as one lengthMake:- Havells/ Polycab/ Plaza. |
| 52 | S&F factory madepowder coated distribution board SPN 8 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar confirming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 53 | S & F MCB SPN 240 volts 40 to 63 Amps suitable for \"C\" curve, 10 KA complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian. |
| 54 | S&F 35/36 W (WW) LED recessed/surfacetype2x2 ft luminaire with classic design & glare free soft illumination. housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens.Make : Philips/ Bajaj/CG/Havells. |
| 55 | Material and labourfor shifting of Air Conditioner, Split type capacity 1.5/2 TR from existing location to new location as per user requirement and installing, toping up of gas, servicing the AC , replacement of copper tubing connecting up, commissioning and testing complete all as specified and as directed.Note :- The rate for following works deemed to be included in quoted rate :-(a)Transportation of air conditioner any type any capacity from one to other location. (b) Fixing only base plate with necessary fixing material on stone / brick walls and as directed (c) Fixing only outdoor and indoor units as required and directed (d) Connecting indoor / outdoors units of split ACs with copper tubes, flairs nuts, warping suction and discharge lines with inclucating materials with necessary fixing arrangements such as bolts, nuts washers and clamps etc. on walls (e) fixing PVC pipes 20 mm dia for outlet of indoor units to drain out dew water with necessary clamps. (f) Fixing of wall mounting voltage stabilizer of 3 KVA to 5 KVA capacity on the wall with necessary fixing arrangements such as bolts, nuts washers and clamps etc on wall. (g) Fixing PVC hose/ PVC pipes of 15mm sizes as reqd at site with necessary junction boxes, PVC bends etc. including two length of PVC copper cables of 4 sqmm size for electrical connection of ACs. (h) No additional payment shall be made for leakage of gas occurring during shifting of Air Conditioner and topping up of required gas.(j) Re fixing of copper tubing of qty of required size. |
| 56 | Supply, installation, testing & commissioning air cooled, split unit (indoor and outdoor) air conditioner electric driven AC 230 V, 50 Hz single phase of capacity 1.5 TR, BEE 3 Star rated with cooling and intelligent heating facility and Digital Inverter twin rotary including its fixing accessories with following specification :-(a) Rated cooling capacity - 18000 Btu/Hr.(b) Rated current cooling - 7.8 Amp.(c) Rated heating capacity - 18000 Btu/Hr.(d) Compressor type - Highr EER twin Rotary.(e) Anti dust/anti-bacterial Filter.(f)Dehumidifier.(g) Refrigerant gas - R32.(h) Operation : LCD Remote with self dignosis facility all as specified and directed.Make: Voltas/Bluestar/HitachiNote :- The quoted rate shall deem to be included for powder coated stand (Bracket) for fixing outdoor unit and cutting, chasing of wall/ surface and making good as per existing. |
| 57 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA all as specified and as directed. Make :V-guard/Microtech/AE |
| 58 | Supply & Fixing of drain outlet PVC 20 mm dia connected from rear side of AC upto drain with necessary clamp and fixtures on wall and floor all as specified and as directed. |
| 59 | Supply and fixing as in repair ofCopper tubing of size 1/2\" flare size conforming to relevant IScomplete all as specified and directed. |
| 60 | Supply and fixing as in repair ofCopper tubing of size 1/4\" flare size conforming to relevant IS complete all as specified and directed. |
| 61 | Supply and fixing as in repairof Copper tubing of size 5/8\" flare size conforming to relevant IS complete all as specified and directed. |
| 62 | Supply and fixing as in repair of Copper tubing of size 3/8\" flare size conforming to relevant IScomplete all as specified and directed. |
| 63 | Supply and fixing ofStand of Condenser motor in outdoor unit for 1.5/2 TR AC of existing place complete all as specified and as directed. |
| 64 | Supply only Refrigerant gas R-32in manufacturer\"s sealed cylinder complete all as specified and as directed.(i) Empty cylinder shall be returned to contractor.(ii) Payment shall be made for net weight of gas filled. |
| 65 | Supply & fix metal clad switch socket single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 32A concealed/surface on walls complete all as specified and as directed.Make : Havells/ Indo asian/ Legrand |
| 66 | M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 Sqmm drawn through in and incl suitable size surface PVC casing caping/PVC Conduit and all accessories fixed to wall/floors along with 4 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and directed.Note: (a)2 runs of 4 Sqmm cable along with one run of 4 Sqmm cable for earth conductor shall be measured as one lengthMake:- Havells/ Polycab/ Plaza. |
| 67 | S&F factory madepowder coated distribution board SPN 4 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 68 | S & F MCB SPN 240 volts 16 to 32 Amps complete complete all as specified and as directed.Make : Legrand/ L&T/ Indo Asian |
| 69 | Supply & fix metal clad switch socket single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A concealed in walls complete all as specified and as directed.Make : Havells/ Indo asian/ Legrand |
| 70 | S & F MCB single pole 240 volts 6 to 32 Amps suitable for \"C\" curve, 10 KA complete complete all as specified and as directed. Make : Legrand/ L&T/ Indo Asian. |
| 71 | Supply, installation, testing and commissioning LTpanel CPRI Testedof suitableSize andsuitable for 3 phase 415 Volts of suitable size out door made out of 3.15mm thick CRCA sheet for outdoorpanel with angle iron frame of size 50x50x6mm cubical type complete with aluminium bus bar 1000 Amp and including PCC foundation as per site requirement to accomodate to the following.INCOMING(a)MCCB 4 pole 160 Amp 36 KA - 01 No. (b)LEDindicating lampR-Y-B - 03 Nos.(c)Multifunction Meter (V,I,PF) with suitable capacity of CT\"s- 01 NoOUTGOING(a) Through bus bar |
| 72 | Supply and Fixingof GI pipe light grade for cable protection of size 50mm bore with fittings, complete all as specified and directed. |
| 73 | Material and labour for 3 ½ core 35 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian |
| 74 | Supply, installation, testing and commissioning LTpanel CPRI Testedof suitableSize andsuitable for 3 phase 415 Volts of suitable size out door made out of 3.15mm thick CRCA sheet for outdoor of panel with angle iron frame of size 50x50x6mm cubical type complete with aluminium bus bar 1000 Amp and including PCC foundation as per site requirement to accomodate to the following.INCOMING(a)MCCB 4 pole 63 Amp 16 KA - 01 No. (b)LEDindicating lampR-Y-B - 03 Nos.(c)Multifunction Meter (V,I,PF) with suitable capacity of CT\"s- 01 NoOUTGOING(a) Through bus bar |
| 75 | Supply, installation, testing & commissioning of maintenance free chemicalearthing system comprising of 17mm dia copper bondedrod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducingliquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation complete all as specified and directed.Make : Model HTSP 317 of safeTrode or equivalent in Snaga/ Cubes 6 Global |
| 76 | The quoted rate shall also deemed to be included the following :- (i)Prior toinstallation of maintenance free chemicalearthing, soil resistivity test to be carried out at the location where earthingwork to be donein presence of Engr-in- Charge/JE (E/M),user and the report has tosubmitto Garrison Engineer with recommendation of manufacturer, if required additional interconnection ofearthing (not more than 08 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testingandsubmission of report with recommendationdeemed to be included in the quoted rate. |
| 77 | (ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors. |
| 78 | (iii) Rateofearth energizer compound of 25 Kg of 02 bags and earthresistance reducingliquid 10 litre per cane for each pit deemed to be included in the quoted rate. |
| 79 | (iv)Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor along with the sample approval |
| 80 | (v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete. |
| 81 | (vi) Copper strip of size 20 x 3 mm shallbe fixed on proper post insulator at the instrument end (copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately). |
| 82 | (vii)Testing of earth shall be carriedout in presence ofdepartmental and user representativeand report shall be submitted to Garrison Engineer duly signed by all concerned. |
| 83 | (viii)Earth resistance tester will be provided by the contractor.Tester should be calibrated from authorised company/ lab. |
| 84 | (ix)Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned.After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained. |
| 85 | (x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion. |
| 86 | (xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock. |
| 87 | (xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained. |
| 88 | (xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period. |
| 89 | (xiv) The electrode shallcarry manufacturer\"s name . |
| 90 | (xv) The connection clamp shall be permanentlly welded to the copper boundedrodto avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination. |
| 91 | (xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm. |
| 92 | (xvii)Earth work such as auguring andmaking good the surrounding area shall carried out in any type of soil. |
| 93 | (xviii)The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material. |
| 94 | (xix) Sign boardof mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxideZinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge. |
| 95 | M&L in repair Earth pit cover madeof heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mmfor each electrode pit, complete all as specified and directed. |
| 96 | S&F in repair copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc complete all as specified anddirected. Note : - All Joints should be joined by Exothermic Welding or Brazing. |
| 97 | Note :- An amount of Rs 4,590.00 on account of credit schedule for schedule \"A\" part II shall be deducted from the total amount of BOQ to arrive at the contract sum. |