Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Taking down cement plaster on brick wall of any description, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by Engineer-in-charge. |
| 2 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as per specified and as directed by Engineer-in-charge. |
| 3 | Demolition of unreinforced cement concrete in ground floors and pavings n-exc 15 cm thickness (below or above ground level) complete all as specified and as directed by Engineer-in-charge. |
| 4 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) exceeding 1.5 Sqm but not exceeding 4 Sqm each and removing from site, complete all as specified and as directed by Engineer-in-charge. |
| 5 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) not exceeding 1.5 Sqm each and removing from site, complete all as specified and as directed by Engineer-in-charge. |
| 6 | S&F of Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as per specified and as directed by Engineer-in-charge. |
| 7 | Supply and fixing factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. .frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail,; Panelling of plain colour PVC sheet to be fitted in the M.S.frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as per specified and as directed by Engineer-in-charge. |
| 8 | S&F of pressed steel frames (Size-105X60mm) for doors with one or more rebates incl necessary fixing lugs, hinges, lock strike plate etc complete all as specified and as directed by Engineer-in-charge. |
| 9 | S&F ofPressed steel frames of size 125x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as per specified and as directed by Engineer-in-charge. |
| 10 | M&L for 35 mm thick second class hardwood glazed and skeleton shutter open rebated and prepared to receive glass, gauge etc (without sash bar) edges of framing plain, chamfered orrounded fitted with cut and mitred beads for securingglass etc sizes of member (Bottom 250mm, stiles 100mm, top 120mm & lock rail 160mm wide)as specified in SSR part I section & clause 8.24 (a) complete all as specified and as directed by Engineer-in-charge. |
| 11 | S&F of 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete all as per specified and as directed by Engineer-in-charge. |
| 12 | S&F ofpowder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.Note :- Weight of Aluminium sections for frames and shutters shall be only considered for payment.Cost of other consumables required for the item shall be deemed to be included in the quoted rate.However glass panes /wire clothonly will be measured and paid separately under respective items as supply only.Fixing by element of these items shall be deemed to be included in quoted rate. |
| 13 | S&F ofPowder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions ofEngineer-in-charge.Note :- Weight of Aluminium sections for frames and shutters shall be only considered for payment.Cost of other consumables required for the item shall be deemed to be included in the quoted rate.However glass panes /wire clothonly will be measured and paid separately under respective items as supply only.Fixing by element of these items shall be deemed to be included in quoted rate. |
| 14 | S&F in repair of Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples complete all as specified and as directed by Engineer-in-charge. |
| 15 | M&L for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as per specified and as directed by Engineer-in-charge. |
| 16 | S&F of 4 mm thick sheet glass of ordinary quality in squares not exc. 0.5 sqm in each pane glazing with oil putty complete all as per specified and as directed by Engineer-in-charge. |
| 17 | S&F of 4 mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as per specified and as directed by Engineer-in-charge. |
| 18 | S&F of 100 mm butt hinges, medium weight, cold rolled mild steel and fixed complete all as per specified and as directed by Engineer-in-charge. |
| 19 | S&F of 150 mm extruded aluminium alloy handles, fabricated type, anodised complete all as per specified and as directed by Engineer-in-charge. |
| 20 | S&F of 150 mm long aluminium, anodised, barrel tower bolts of extruded section, complete all as per specified and as directed by Engineer-in-charge. |
| 21 | S&F of 300 mm long mild aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as per specified and as directed by Engineer-in-charge. |
| 22 | M&L for preparation of old painted surfaces of steel surfaceof any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and as directed by Engineer-in-charge. |
| 23 | M&L for preparation of old painted surfaces of wood and wood based materials of any description, not otherwise described and applying one coat of synthetic enamel paint over 10 cm width or girth, complete all as per specified and as directed by Engineer-in-charge. |
| 24 | S&F in repair of rotational moulded polyethylene water storage tanks double layered ISI Marked (cylindrical, vertical with closed top) of 500 litres capacity hoisted and fixed in position including connecting up pipes securing access covers etc, complete all as per specified and as directed by Engineer-in-charge. |
| 25 | S&F in repair of 25 mm ball brass valves, high pressure, with polythene float and flynet complete, screwed for iron pipe or brass ferrule and fixed complete all as per specified and as directed by Engineer-in-charge. |
| 26 | M&L for roughening surfaces of existing roof treatment and taking out old app membrane and removing from site including sweeping cleaning and washing down with water to remove dust, etc., complete all as per specified and as directed by Engineer-in-charge. |
| 27 | M&L for brushing neat cement slurry with 3.0kg of cement per sq. metre, complete all as per specified and as directed by Engineer-in-charge. |
| 28 | M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 includingmixing WPC as per manufacturer\"s instruction, surface even & smooth without using extra cement, complete all as specified and as directed by Engineer-in-charge.(Note: WPC shall be measured and paid separately as supply only under relevant item.) |
| 29 | M&L for two coats of UV resistant acrylic polymer blended elastomeric coating over 10mm thick screed in CM (1:4) (finished when the concrete is green) mixed with integral water proofing compound over RCC, complete all as specified and as directed by Engineer-in-charge. |
| 30 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:6 including, surface even & smooth without using extra cement, complete all as specified and as directed by Engineer-in-charge. |
| 31 | M&L for 5 mm thick rendering plastering on fair faces of brick work or concrete surface in cement mortar (1:3) and surface even and smooth without using extra cement, complete all as specified and as directed by Engineer-in-charge. |
| 32 | M&L for 20 mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers (10mm& 10mm) mixed with water proofing compound in top layer at the rate 3% of weight of cement 200 ml per beg of cement or as per manufacturer\"s instructions finishing the surface even and fair without using extra cement complete all as specified and as directed by Engineer-in-charge.(Note: WPC shall be measured and paid separately as supply only under relevant item.) |
| 33 | Supply only integral water proofing compound confirming to IS complete all as per specified and as directed by Engineer-in-charge. |
| 34 | M&L for preparing new plastered surface and applying two coats of distemper oil emulsion on wall surfaces over a coat of alkali resistant primer and 2 mm thick wall putty complete all as specified and as directed by Engineer-in-charge. |
| 35 | M&L for preparation of new plastered surfaces of wall and applying one coat of approved primer or elastomeric base coating as specified by the manufacturer, followed by allowing it to dry under torch-dry condition for a minimum of 8 hours. Thereafter, two coats of waterproofing decorative elastomeric coating shall be applied with a minimum dry film thickness of 100 microns. The surface shall be allowed to dry for 6 to 8 hours between coats. The work shall include all necessary scaffolding and shall be carried out strictly as per manufacturer’s instructions, complete all as specified and as directed by the Engineer-in-Charge. |
| 36 | M&L for preparing newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed by Engineer-in-charge. |
| 37 | M&L for complete removal of existing treatment from wall surfaces by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots including washing down with water and applying two coat of distemper oil emulsion on walls surfaces over a coat of alkali resistant primer complete all as specified and as directed by Engineer-in-charge. |
| 38 | M&L for complete removal of existing treatment from wall surfaces by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots including washing down with water and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over and applying 3 mm thick wall putty complete all as specified and as directed by Engineer-in-charge.Note: The above mentioned treatment to be done by the contractor from authorised applicator of the manufacturer(s) and necessary documents for authentication shall be submitted by the contractor to the GE in this regard. |
| 39 | M&L for preparing old plastered surfaces of ceiling and applying two coats of white wash complete all as specified and as directed by Engineer-in-charge. |
| 40 | M&L for 25 mm thick for cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregates) as in sub-base, flooring etc, complete all as per specified and as directed by Engineer-in-charge. |
| 41 | M&L for 75 mm thick PCC type C-2, 1:3:6 (using 40 mm graded aggregate) as in flooring, plinth protection/footpath finishing cement concrete surface even and smooth without using extra cement, complete all as specified and as directed by Engineer-in-charge. |
| 42 | M&L for removing loose, disturbed or disintegrated old concrete surfaces of RCC beam, column, lintel, pardi, railing etc, cleaning thoroughly exposed reinforcement, by sand blasting using suitable pump as directed by the GE, preparing exposed concrete surfaces to receive guniting, applying one coat of anti corrosive paint to the exposed reinforcement, supply and fix welded wire mesh of size100 x 100 mm of 3 mm dia wire, weight not less than 1.37 Kg/Sqm & binding with 22 gauge mild steel (annealed)binding wire to reinforcement and applying pressure guniting in cement mortar 1:3, minimum thickness 30 mm and thereafter rendering 10 mm thick plaster in cement mortar 1:3, mixed with water proofing compound @2% by weight of cement and finishing the surfaces even and smooth without using extra cement to match with the existing surfaces, removing the debris outside MD land including material and labour for necessary scaffolding and safety arrangement for guniting work, complete all as per specified and as directed by Engineer-in-charge.(Note :-The finish of the surfaces to be matched with the existing surface.WPC shall be measured & paid separately as supply only). |
| 43 | M&L for Kota stone flooring 20-25 mm thick and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over 20 mm thick screed bed or bedding layers in CM 1:6, complete all as specified and as directed by Engineer-in-charge. |
| 44 | M&L for Kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and as directed by Engineer-in-charge. |
| 45 | S&F coloured non-skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but notexceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shades of tiles, complete all as per specified and as directed by Engineer-in-charge. |
| 46 | S&F of coloured non-skid ceramic tiles 7 to 8 mm thick (Square/ rectangular) area of each tile exceeding 0.18 sqm but notexceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shades of tiles complete all as per specified and as directed by Engineer-in-charge. |
| 47 | M&L for coloured glazed ceramic tiles 350x 250x 7 mm/ 450X 350X 7mm thick, on vertical surfaces such as skirting, dados and risers to stepsetc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over, complete all as specified and as directed by Engineer-in-charge. |
| 48 | Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar (rainforement curt as required to fasilitate demolition) suspended work complete all as specified and as directed by Engineer-in-charge. |
| 49 | M&L for Mild steel TMT bars 10 mm dia. and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips, complete all as per specified and as directed by Engineer-in-charge. |
| 50 | M&L forRCC type B-0, 1:2:4 (12.5 mm graded aggregate) as in chajjas, beam, column, roof, landing, shelf, platform, facia and like, complete all as per specified and as directed by Engineer-in-charge. |
| 51 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as per specified and as directed by Engineer-in-charge. |
| 52 | S&F of 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls, complete all as per specified and as directed by Engineer-in-charge. |
| 53 | S&F of 110 mm dia bore PVC (SWR)bends, complete all as specified and as directed by Engineer-in-charge. |
| 54 | S&F of 110 mm dia bore PVC (SWR) junction (single T) equal or un-equal with access door, complete all as per specified and as directed by Engineer-in-charge. |
| 55 | S&F of 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls, complete all as per specified and as directed by Engineer-in-charge. |
| 56 | S&F of PVC (SWR) 75 mm bore bends complete all as per specified and as directed by Engineer-in-charge. |
| 57 | S&F of 75 mm bore PVC (SWR) junction single (Single `T\") equal or unequal with access door complete all as per specified and as directed by Engineer-in-charge. |
| 58 | S&F in repair of white vitreous china wash basin, flat back type, size 550x400 mm, excluding taps and waste fittings, but including chain and plug with porcelain stopper, brackets, cutting for pinning in ends of brackets or erecting stand, and 32 mm brass chromium-plated waste pipe, complete all as specified and as directed by the Engineer-in-Charge. |
| 59 | S&F in repair of 15mm dia, angle/stop valve, cast copper alloy, fancy type, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as per specified and as directed by Engineer-in-charge. |
| 60 | S&F in repair of 15mm dia, bib taps, cast copper alloy, fancy type, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as per specified and as directed by Engineer-in-charge. |
| 61 | S&F in repair of PVC connections 15mm size with PTMT nuts of length 450 mm length including brass nuts, complete all as specified and as directed by Engineer-in-charge. |
| 62 | S&F in repair of white vitreous China wash down water closet pan (pedestal pattern) EWC, of size 570 x 460 x 380 mm with ‘P’ or \"S\" trap, including fixing bolts, plastic water closet seat and cover, closed pattern with flat bottom, and mild steel chromium plated or aluminium anodised hinging device, making all necessary connections and making good the disturbed surfaces of floor, complete all as specified and as directed by Engineer-in-charge. |
| 63 | S&F in repair of PVC valveless double siphonic action type flushing cistern low level of 10 Litre capacity white with inlet ball valve, float, flushing bend & handle including brackets, suitable for both Indian type water closet & European type water closet including brackets & connection to pipe etc., complete all as specified and as directed by Engineer-in-charge. |
| 64 | Demolition of brick work (laid flat or on edge) or brick tiles tiles laid bedded & pointed in any mortar in drain etc complete all as specified and as directed by Engineer-in-charge. |
| 65 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soil, complete all as specified and directed by Engineer-in-charge. |
| 66 | Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge. |
| 67 | Returning,filling in, including spreading, levelling, watering and well ramming in layers n exc 25cm complete all as per specified and as directed by Engineer-in-charge. |
| 68 | M&L for PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in surfaces channels and drains incl necessary formwork complete all as per specified and as directed by Engineer-in-charge. |
| 69 | M&L for PCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in drains an the like including weathering slightly rounded or chamfered angles and throating Engineer-in-charge. |
| 70 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends complete all as specified and as directed by Engineer-in-charge.(Note:- Inner Girth Only measured) |
| 71 | M&L for brick work with sub-class \"B\" bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 concrete complete all as per specified and as directed by Engineer-in-charge. |
| 72 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 including, surface even & smooth without using extra cement, complete all as specified and as directed by Engineer-in-charge. |
| 73 | M&L for mild steel TMT bars 6 mm to 8 mm dia., cut to length, bent to shape required, including cranking, bending spirally for hooping for manhole cover, hooking endsand binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips quality confirming to Fe-410-S or Fe-410-O, complete all as per specified and as directed by Engineer-in-charge. |
| 74 | M&L for precast cement concrete (1:2:4) type B1 (using 20 mm gradedcrushed stone aggregate) as in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces set in cement mortar 1:4 including necessary formwork, complete all as specified and as directed by Engineer-in-charge. |
| 75 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and as directed by Engineer-in-charge. |
| 76 | M&L for mild steel TMT bars 5mm dia and over upto encl 10mm dia ., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips quality confirming to Fe-410-S or Fe-410-O, complete all as per specified and as directed by Engineer-in-charge. |
| 77 | M&L forRCC type B-0, 1:2:4 (12.5 mm graded aggregate) as in slabs, shelves and like, complete all as per specified and as directed by Engineer-in-charge. |
| 78 | M&L for formwork to soffits of pillars, post, struts, column and similar work fair finished surface of concrete flat complete all as specified and as directed by Engineer-in-charge. |
| 79 | M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick (horizontal or sloping) including edges fair finished surface of concrete flat complete all as specified and as directed by Engineer-in-charge. |
| 80 | Demolition and breaking up including removing salt glazed stoneware pipe 150 mm bore (internal) with concrete bedding and haunching complete including necessary earth work as required complete all as specified and as directed by Engineer-in-charge. |
| 81 | M&L for PCC 1:4:8 Type D2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as per specified and as directed by Engineer-in-charge. |
| 82 | M&L for PCC 1:3:6 Type C2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as per specified and as directed by Engineer-in-charge. |
| 83 | M&L for concrete bed 1:3:6 type C2 (40 mm graded stone aggregate) to 150 mm dia. drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested, complete all as per specified and as directed by Engineer-in-charge. |
| 84 | M&L for cement concrete 1:2:4 type, B-1 (using 20 mm graded stone aggregates) as in copings, bed plate, fillets and other similar works including necessary formwork, weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed by Engineer-in-charge. |
| 85 | S&F 15mm internal dia of DWCPE pipes SN-8 laid and jointed complete with collar all as specified |
| 86 | Returning filling in including spreading levelling watering and well ramming in layers not exec 25 cm |
| 87 | M&L for special treatment for sunken portion of WCs, bathrooms and toilets, executed in the following stages:Stage 1: Demolition of existing WC including lime concrete and cement concrete, and preparation of surfaces of existing sunken portion of WCs/baths by cleaning with wire brush to remove all loose dirt, oil, grease etc., including removal of debris from site of work, complete.Stage 2: Providing 10 mm thick plaster in CM 1:3 mixed with approved integral waterproofing compound in recommended proportion/quantity, all as per manufacturer’s instructions, complete.Stage 3: Applying approved waterproofing primer and allowing to dry for minimum 8 hours, all as per manufacturer’s instructions.Stage 4: Applying two coats of approved elastomeric waterproofing coating system having minimum DFT of 100 microns. The surface after applying one coat shall be allowed to dry for minimum 6 hours before application of the next coat, all as per manufacturer’s instructions.Stage 5: Rendering 10 mm thick plaster in CM 1:3 mixed with approved integral waterproofing compound, all as per manufacturer’s instructions.Stage 6: All CI joints shall be filled with a mixture of cement, fine sand and approved waterproofing compound, all as per manufacturer’s instructions.Stage 7: Making holes in wall and fixing 600 mm long, 40 mm dia medium grade GI spout for draining surplus water, if any.Stage 8: Carrying out ponding test for 48 hours to ensure water tightness of repaired sunken portion. After successful water tightness test, filling of sunken portion with cement concrete Type E2 (1:5:10) using 40 mm graded aggregate as in lean concrete, complete, all as specified and as directed.Note:(a) Only plan area shall be measured and accounted for payment under this item.(b) Depth of sunken portion of WCs/Baths shall be up to 35 cm, which shall be taken into account while quoting the rate against this item.(c) Rate quoted by the contractor shall be deemed to include all horizontal and vertical treated surfaces of sunken portions of WC & Bath. |
| 88 | Taking down carefully old unserviceable copper/ aluminium point wiring (light, exhaust fan, socket or power) complete incl fittings such as switches, ceiling roses, pendants, regulators, bells, sockets, tube light fittings etc., and making good disturbed surface of walls & floors etc., complete all as specified and as directed by Engineer-in-charge. |
| 89 | Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store, complete all as specified and as directed by Engineer-in-charge. |
| 90 | M&L for concealedpoint wiring with two single core PVC insulated, unsheathed, multistranded copper conductor FRLS of size 1.5 Sq. mm and one single core PVC insulated unsheathed stranded copper conductor of size 1.50 Sq. mm green in colour as earth lead in through existing PVC rigid conduit (medium grade) with all fittings & accessories for mounting modular switch, sockets, fan regulators etc. for one light / fan/bell point, complete all as specified and as directed by Engineer-in-charge.NOTE : Cost of making good the disturbed surfaces (if any) matching with the existing surface is deemed to be included in the quoted rates. Modular fitting will be paid & measured under relevant items separately. |
| 91 | M&L for concealedpoint wiring with two single core PVC insulated, unsheathed, multistranded copper conductor FRLS of size 1.5 Sq. mm and one single core PVC insulated unsheathed stranded copper conductor of size 1.50 Sq. mm green in colour as earth lead in through new coduit concealed not less than 25mm in wall/ ceiling PVC rigid conduit (medium grade) with all fittings & accessories for mounting modular switch, sockets, fan regulators etc. for one light / fan/bell point, complete all as specified and as directed by Engineer-in-charge.NOTE : Cost of making good the disturbed surfaces (if any) matching with the existing surface is deemed to be included in the quoted rates. Modular fitting will be paid & measured under relevant items separately. |
| 92 | All as per serial item No. 91 above but for One light point controlled by two 2 - way switches, complete all as specified and as directed by Engineer-in-charge. |
| 93 | All as per serial item No. 91 above but for socket outlet 5/6 AMPs point on independent board, complete all as specified and as directed by Engineer-in-charge. |
| 94 | All as per serial item No. 91 above but for wiring with single core, multistranded copper conductor of size 2.5 sqmm for 15/16 AMPs socket out let point on independent board, complete all as specified and as directed by Engineer-in-charge. |
| 95 | S&F of Modular Switch single pole, one way, 6 Amps, 1 module, 230 volts, ISI marked, complete all as specified and as directed by Engineer-in-charge. |
| 96 | S&F of Modular Switch single pole, one way, 16 Amps, 1 module, 230 volts, ISI marked, complete all as specified and as directed by Engineer-in-charge. |
| 97 | S&F of Modular shutter socket outlet 5 pin, 6 Amps, 2 module, 230 volts, ISI marked, complete all as specified and as directed by Engineer-in-charge. |
| 98 | S&F of Modular shutter socket 6A/16A - 2/3 pin combined 2 module, 230 volts, ISI marked, complete all as specified and as directed by Engineer-in-charge. |
| 99 | S&F of ceiling rose surface PVC three terminals, PVC/ polycarbonate, insulated body, complete all as specified and as directed by Engineer-in-charge. |
| 100 | Supply and fixing of LED tube light fittings1 x 20 Watt, 220 V, AC decorative box type with driver holder including LED tube rod connecting up with three core flexible copper conductor cable from ceiling rose to tube light fitting complete all as specified and as directed by Engineer-in-charge. |
| 101 | Supply and fixing of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed by Engineer-in-charge. |
| 102 | Supply and fixing of ceiling fans complete with blades, down rods, 2M, min 70Watt, 5 step electronic regulator and accessories, 230Volts, 1200mm sweep, minimum air delivery 210CFM with service value 6BEE five star rated with brushless direct current motor (BLDC) with synchronized regulator or remotecomplete all as specified and as directed by Engineer-in-charge. |
| 103 | Supply and fixing of round shape 6 watts, 220 volts AC surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor of sutable sizecomplete all as specified and as directed by Engineer-in-charge. |
| 104 | Supply and fixing of LED light fittings 600mm x600mm 35/36 watts, 220 volts AC surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor of sutable sizecomplete all as specified and as directed by Engineer-in-charge. |
| 105 | Supply and fixing of sheet metal enclosure powder painted for MCCB VTPN 8 way double door DB, 415 Volts, 200 Amp with din rail and bus bar including making good to the disturbed surface matching with the existing including taking down old unserviceable one, complete all as specified and directed by Engineer-in-charge. |
| 106 | Supply and fixing of sheet metal enclosure powder painted for MCB TP & N 4 way double door DB, 415 Volts, 200 Amp with din rail and bus bar including making good to the disturbed surface matching with the existing including taking down old unserviceable one, complete all as specified and directed by Engineer-in-charge. |
| 107 | Supply and fixing of sheet metal enclosure powder painted for MCB SPN 8 way double door DB, 240 Volts, 200 Amp with din rail and bus bar including making good to the disturbed surface matching with the existing including taking down old unserviceable one, complete all as specified and directed by Engineer-in-charge. |
| 108 | Supply and fixing of 415V 10KA \"C\" curve miniature circuit breaker (MCB) of Triple pole & neutral (TPN) 40 To 100 Amps and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed by Engineer-in-charge. |
| 109 | S&F of 240V, 10 KA \"C\" curve miniature circuit breaker (MCB) of SPN and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioningcomplete all as specified and as directed by Engineer-in-charge. |
| 110 | Supply and fixing of amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of SP 6 To 32 AMP current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed by Engineer-in-charge. |
| 111 | M&L for Pipe earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 4 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected to galvanised earth pipe by means of 25x 4mm bolts, nuts, checknuts and washers of galvanised iron including PCC (1:2:4) type B-1 precast RCC cover slab with suitable handle made of 6mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one and protection pipe of 40mm dia light grade galvanised steel tubing up to 7.5 meters length for drawing earth lead including common salt, charcoal, bentonite in alternate layers etc, complete all as shown in EP number 2 of SSR part-1 including testing on completion including taking down old unserviceable cable, complete all as specified and as directed by Engineer-in-charge.Note - The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule \"A\"/BOQ. |
| 112 | M&L for sub main wiring two run of size 6 sqmm PVC insulated, ISI marked, FRLSH unsheathed, electric power cable (heavy duty) 1100 volts grade with stranded copper conductor with 6.0 sqmm PVC insulated stranded copper conductor earth wire in PVC conduit of suitable size (two run of 6 sqmm cable and one of 6.0 sqmm wire and one run of PVC conduit will be measured as one unit) including taking down old unserviceable cable, complete all as specified and as directed by Engineer-in-charge. |
| 113 | M&L for sub main wiring two run of size 4 sqmm PVC insulated, ISI marked, FRLSH unsheathed, electric power cable (heavy duty) 1100 volts grade with stranded copper conductor with 4.0 sqmm PVC insulated stranded copper conductor earth wire in PVC conduit of suitable size (two run of 4 sqmm cable and one of 4.0 sqmm wire and one run of PVC conduit will be measured as one unit) including taking down old unserviceable cable, complete all as specified and as directed by Engineer-in-charge. |
| 114 | S&F of exhaust fan, steel body, AC single phase 230/240V, size 300 mm sweep, complete with blades, frame, and louvers, and removing the existing fan and blades to store, complete all as specified and as directed by the Engineer-in-Charge. |
| 115 | S&F of wall fan, AC single phase 230/240V, size 450 mm sweep, fixing on wall and removing the existing fan and blades to store, complete all as specified and as directed by the Engineer-in-Charge. |
| 116 | S&F of exhaust fan, made of sturdy engineering plastic body, AC single phase 230/240V, size 250 mm sweep, complete with blades, frame, and louvers, and removing the existing fan and blades to store, complete all as specified and as directed by the Engineer-in-Charge. |
| 117 | Supplying, installation, commissiong and testing hi wall split 1.5 TR AC units indoor/outdoor unit complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 strat rating and EER 3.2 of capacity complete all as specified and as directed by Engineer-in-charge. |
| 118 | Supplying, installation, commissiong and testing hi wall split 2.0 TR AC units indoor/outdoor unit complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 strat rating and EER 3.2 of capacity complete all as specified and as directed by Engineer-in-charge. |
| 119 | Supply and fixing in repair of LED security light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed by Engineer-in-charge. |
| 120 | S&F of 2KM double mounted single phase electronic siron system including necessary accessories for elephant menace as approved by GE complete all as per specified and as directed by Engineer-in-charge. |
| 121 | Supply and fixing security light bracket made out of 25mm dia GI pipe medium grade with length not less than 1.5m long with two sets clamp and nuts & bolts, bend to shape for fixing security light fittingscomplete all as specified and as directed by Engineer-in-charge. |
| 122 | M&L for taking down existing CCTV Camera/Speaker cable & any other type of cable/wire and refixing through casing caping of size minimum 50mm (ISI marked) thoroughly fixed on wall/ceiling complete all as specified and as directed by Engineer-in-charge. |
| 123 | S&F of 90mm outer diadouble corrugated pipe (DWC) for enclosing cable belowbelow ground/ road surface to a required depth including suitable couplers for joining of pipecomplete all as specified and as directed by Engineer-in-charge. |
| 124 | Supply, laying & testing of XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100Volt grade on walls with fixing accessories of size 16 Sqmm 4 Core cable including taking down old unserviceable, complete all as specified and directed by Engineer-in-charge.Note:- Excavation & earth work, sand cushioning, bricks protection & GIpipe where required shall be measured & paid separately. |
| 125 | Supply, laying & testing of XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100Volt grade on walls with fixing accessories of size 150 Sqmm 3.5 Core cable including taking down old unserviceable, complete all as specified and directed by Engineer-in-charge.Note:- Excavation & earth work, sand cushioning, bricks protection & GIpipe where required shall be measured & paid separately. |
| 126 | Supply, laying & testing of XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100Volt grade on walls with fixing accessories of size 185 Sqmm 3.5 Core cable including taking down old unserviceable, complete all as specified and directed by Engineer-in-charge.Note:- Excavation & earth work, sand cushioning, bricks protection & GIpipe where required shall be measured & paid separately. |
| 127 | S&F of 7 meter long GI octagonal poles complete including necessary excavation, PCC 1:3:6 type C2 as in foundation and PCC 1:2:4 type B1 for coping including bolts, nuts, screws and two bracket fixed on the top of the pole with cap enclosure complete all as per specified and as directed by Engineer-in-charge. |
| 128 | Supply and fixing in repair of LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed by Engineer-in-charge. |
| 129 | Supply and fixing water proof 3 core PVC insulated and PVC sheathed, copper conductor cable of size 2.5Sqmm, 1100 volts grade including PVC conduits properly fixed on steel poles using GI wire for electrical connection of street light fittingscomplete all as specified and as directed by Engineer-in-charge. |
| 130 | Supply and fixing junction box having protection dust proof acid resitant, shock proof, fire retardent swelf extingusher for out side installation with knockout entry for cable of size 10=16sqmm and size ofg box 155mm x 210mm x 92mm with terminal, brackets for street loght pole mounting and provision of one SP MCB 6 Amp, complete all as specified and as directed by Engineer-in-charge. |
| 131 | S&F in repairs of 8 KW, three phase automatic street light timer switch for automatic switching off/on street light based on lux level of nature light, consisting of sensor overload protection fuse gear, power contractor and MCB of suitable capacity, terminal blocks for cable entry and control unit enclosed in pole/ wall mounted enclosure made out of rust proof, shock proof, termite proof FR grade SMC, conforming to IP 66 with universal lock and key arrangementcomplete all as specified and as directed by Engineer-in-charge. |
| 132 | M & L for horizontal boring across the existing road without disturbing the road surface for inserting GI pipe, of 100mm dia upto 2m deep for cable passing through pipes of required size and disposal of soil to a distance not exc. 50m rotection Complete all as specified and directed by Engineer-in-Charge.Note :- GI pipe Shall be measured and paid respective |
| 133 | Supply and laying/ fixing of GI tube 40 mm bore medium grade with all fittings and fixed to poles or in trenches, floorscomplete all as specified and as directed by Engineer-in-charge. |
| 134 | Supply and fixing of electric water heater, storage type steel body with copper inner tank and heating element up to 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc., complete all as specified and as directed by Engineer-in-charge. |
| 135 | Supply and fixing in repair of LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed by Engineer-in-charge. |
| 136 | Supply and fix of Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed by Engineer-in-charge. |
| 137 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC), complete all as specified and as directed by Engineer-in-charge. |
| 138 | S&F of exhaust fan, steel body, AC single phase 230/240V, size 150 mm sweep, complete with blades, frame, and louvers, and removing the existing fan and blades to store, complete all as specified and as directed by the Engineer-in-Charge. |
| 139 | S&F of exhaust fan, steel body, AC single phase 230/240V, size 300 mm sweep, complete with blades, frame, and louvers, and removing the existing fan and blades to store, complete all as specified and as directed by the Engineer-in-Charge. |
| 140 | S&F of wall fan, AC single phase 230/240V, size 300 mm sweep, fixing on wall and removing the existing fan and blades to store, complete all as specified and as directed by the Engineer-in-Charge. |
| 141 | Supply and fixing of sheet metal enclosure powder painted for MCB TP & N 4 way double door DB, 415 Volts, 200 Amp with din rail and bus bar including making good to the disturbed surface matching with the existing including taking down old unserviceable one, complete all as specified and directed by Engineer-in-charge. |
| 142 | Supply and fixing of sheet metal enclosure powder painted for MCB SPN 12 way double door DB, 240 Volts, 200 Amp with din rail and bus bar including making good to the disturbed surface matching with the existing including taking down old unserviceable one, complete all as specified and directed by Engineer-in-charge. |
| 143 | Supply and fixing of 415V 10KA \"C\" curve miniature circuit breaker (MCB) of Triple pole & neutral (TPN) 40 To 100 Amps and current carrying capacity in the DB complete with connection testing and commissioning including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge. |
| 144 | S&F of 240V, 10 KA \"C\" curve miniature circuit breaker (MCB) of SPN and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge. |
| 145 | Supply and fixing of amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of SP 6 To 32 AMP current carrying capacity in the MCB DB complete with connection testing and commissioning including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge. |
| 146 | M&L for sub main wiring two run of size 6 sqmm PVC insulated, ISI marked, FRLSH unsheathed, electric power cable (heavy duty) 1100 volts grade with stranded copper conductor with 6.0 sqmm PVC insulated stranded copper conductor earth wire in PVC conduit of suitable size (two run of 6 sqmm cable and one of 6.0 sqmm wire and one run of PVC conduit will be measured as one unit) including taking down old unserviceable cable, complete all as specified and as directed by Engineer-in-charge. |
| 147 | Supply, laying and testing ductile iron pressure pipe socket and spigot end, class K-7, confirming to IS-8329/2000 blast furnace slag cement with portland cement properties including push - on- joint (Tyton Joints) and DI fittings i.e. Tee, Elbow etc. with inside cement mortar lining, internal metallic zinc coating and external black bitumen coating of size 100 mm dia duly ISI marked laid in trenches etc complete all as specified and directed. |
| 148 | S&F in repair sluice valve (heavy duty) with SS spindle H/W conforming to IS 14846 both end flanged class PN 1.6 of size 100 mm dia incl necessary nuts,bolts washers and gasket complete all as specified and directed. |
| 149 | Supply,fixing and connecting copper strip of size 32 x 6 mm earth continuty conductor or main earthing lead or for inter connection duly brazing including saddle mounted on porcelain insulator or burried in ground or drawn in pipe fixed to poles or any other indicated situation complete all as specified and as directed. |
| 150 | M&L for construction of valve chamber with MS sheet cover 3mm thick with angle iron) frame of size 50 x 50 x 6mm and locking arrangements including painting one coat of primer followed by two coats of black sysnthetic paint including excvation and earth work in any type of soil,PCC (1:4:8) type D2 in foundation ,PCC benching 1:2;4 type B-1 ,PCC (1:5:8) block masonry 20 cm thick in cement mortor (1:6),10 mm thick plastering in CM 1:4 ,PCC bed in (1:3:6) and coping 50mm hick in cement concrete 1:2:4 type B1 using 20mm stone aggregate including necessary formwork,paintin one coat of red oxide and two coats of bituminious black paint on all steel surfaces as specified and as directed of sizes 1200mm x 1200mm x1200mm (internnal dimensions) including demolition of existing valve chamber,complete all as specified and as directed. |
| 151 | M&L for sub main wiring two run of size 4 sqmm PVC insulated, ISI marked, FRLSH unsheathed, electric power cable (heavy duty) 1100 volts grade with stranded copper conductor with 4.0 sqmm PVC insulated stranded copper conductor earth wire in PVC conduit of suitable size (two run of 4 sqmm cable and one of 4.0 sqmm wire and one run of PVC conduit will be measured as one unit) including taking down old unserviceable cable, complete all as specified and as directed by Engineer-in-charge. |
| 152 | M&L for Pipe earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 4 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected to galvanised earth pipe by means of 25x 4mm bolts, nuts, checknuts and washers of galvanised iron including PCC (1:2:4) type B-1 precast RCC cover slab with suitable handle made of 6mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one and protection pipe of 40mm dia light grade galvanised steel tubing up to 7.5 meters length for drawing earth lead including common salt, charcoal, bentonite in alternate layers etc, complete all as shown in EP number 2 of SSR part-1 including testing on completion including taking down old unserviceable cable, complete all as specified and as directed by Engineer-in-charge.Important Note -The labour working hours for execution of the subject work shall be from morning to late evening (i.e., up to 7:00 PM), or as decided by the KV Principal and the Engineer-in-Charge/GE. Any additional labour cost on account of extended working hours shall be deemed to be included in the quoted rates. The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule \"A\"/BOQ. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail