| 1 | Excavation in trenches not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth and getting out for laying of cables up to proper level and laying of pipelines, foundation etcinsoft/loose soil, complete all as specified and directed. |
| 2 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed. |
| 3 | Removing surplus soil to a distance not exceeding 50 Mtr and deposting where directed at a level not exceeding 1.5 Mtr above the starting point all as directed. |
| 4 | M&L for Ductile Iron Pipe (DI Pipes), ISI marked, Class K-7, 200 mm dia laid in trenches including jointing material such as EPDM Rubber Gasket and suitable type of Grease etc complete all as specified and directed.Note :- (i)DI fitting/special shall be measured and paid separately.(ii) Excavation & earthwork shall be measured & paid seperately |
| 5 | M&L for Ductile Iron Pipe (DI Pipes), ISI marked, Class K-7, 150 mm dia laid in trenches including jointing material such as EPDM Rubber Gasket and suitable type of Grease etc complete all as specified and directed.Note :- (i)DI fitting/special shall be measured and paid separately.(ii) Excavation & earthwork shall be measured & paid seperately |
| 6 | M&L for Ductile Iron Pipe (DI Pipes), ISI marked, Class K-7, 100 mm dia laid in trenches including jointing material such as EPDM Rubber Gasket and suitable type of Grease etc complete all as specified and directed.Note :- (i)DI fitting/special shall be measured and paid separately.(ii) Excavation & earthwork shall be measured & paid seperately |
| 7 | Note :-(a) In case of laying of CI/GI/DI pipe line is to be executed in civil area, it will be the responsibility of the contractor to obtain necessary permission for cutting of road & berm from BWSSB. |
| 8 | (b) For this purpose amount to be paid online to BWSSB, same is deemed to be included in unit quoted rate. |
| 9 | (c) The T&P like JCB, Drill Machine, Moveable Generator etc required for cutting of road shall be arranged by the contractor & no extra cost shall be paid for the same. |
| 10 | (d) After execution of work, the contractor will make good disturbed portion of road with bitumen or PCC complete all as per site requirement and as directed by Engineer-in-Charge. The cost for same is deemed to be included in the unit quoted rate. |
| 11 | M & L for DI specials and fittings as per IS for spigot and socketed pipes or flanged pipe for water mains, branches lines such as bends (any type radious and angle ) tapers any type (straight, bend,increasing,decresing,or double socket etc) tee pieces, single branch,Y juntion, double branch, cross, including connecting pieces one end flanged and other socket or spigot and bell mouth pieces suitable for rubber joint,tyton joint up to 300 mm bore and conforming to IS-9523: 2000 complete all as specified and directed. |
| 12 | Supply and fixing of Sluice valve of size 200 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel fixing with new nuts, bolts, washers and rubber insertion/packing complete all as specified and directed. |
| 13 | Supply and fixing of Sluice valve of size 150 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel fixing with new nuts, bolts, washers and rubber insertion/packing complete all as specified and directed. |
| 14 | Material & Labour for Construction ofValve chamber having inner dimensions 1200 mm x 1200 mm x 1200 mm with foundation in PCC 1:4:8 type D2 using 40mm graded stone aggregate, brick work with sub class B bricks old size built in Cement mortar 1:6, PCC 1:2:4 type B1 using 20mm stone aggregate for Coping, 15 mm thick rendering plaster in CM 1:4 inluding MS cover with locking arrangement all as specified and as directed.Note :- MS work for Chamber cover shall be measured and paid seperately under relevant item of this schedule. |
| 15 | Supply and fixing of Sluice valve of size 100 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel fixing with new nuts, bolts, washers and rubber insertion/packing complete all as specified and directed |
| 16 | Material & Labour for Construction ofValve chamber having inner dimensions 900 mm x 900mm x 900 mm with foundation of PCC 1:4:8 type D2 using 40mm graded stone aggregate, brick work with sub class B old size bricks/ built in Cement mortar 1:6, PCC 1:2:4 type B1 using 20mm stone aggregate for Coping, 15 mm thick renderingin CM 1:4 inluding MS cover with locking arrangement all as specified and as directed.Note :- MS work for Chamber Covers shall be measured and paid separately under relevant item of this schedule. |
| 17 | Material and labourfor Fabricate valve chamber coversmade out of suitable size MS angle/MS plate/flat/rod, hinges, locking arrangement including painting with two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 18 | Material & Labour for Construction ofValve chamber having inner dimensions 600 mm x 600mm x 600 mm with foundation of PCC 1:4:8 type D2 using 40mm graded stone aggregate, brick work with sub class B old size bricks/ built in Cement mortar 1:6, PCC 1:2:4 type B1 using 20mm stone aggregate for Coping, 15 mm thick renderingin CM 1:4 inluding MS cover with locking arrangement all as specified and as directed.Note :- MS work for Chamber Covers shall be measured and paid separately under relevant item of this schedule. |
| 19 | Material and labour forBoring of holes under road, pavement hard standings by trenchless technology using ultra sound technique and necessary machine including supply of HDPE pipes upto 150 mm dia suitable for 0.4 Mpa working pressure, complete all as specified and directed. |
| 20 | Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earthwork, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :-The tenderer shall take into consideration for following points while quoting rate for this item andthe unit rate is deemed to be inclusive for :-(i) Earth work and excavation in any type of soil(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick ,complete all as specified and as directed.(iii) Removing excavated material out side MD land.(iv)Laying of any type/any bore of pipe in trenches including taking down existing unserviceable pipe. Supply of pipe shall be measured and paid separately(v)150 mm thickPCC 1:2:4 type B1 using 20mm graded stone aggregate as inroad to make good existing disturbed surfaces. |
| 21 | M &L for PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as in coppingof any situationincluding necessary form work slightly rounding or squaring, complete all as specifiedand as directed. |
| 22 | M & L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation and mass concrete for complete all as specified and as directed |
| 23 | M&LPre-Cast cement concrete block masonry PCC 1:3:6 type C1 (20 mm graded stone agg) with solid blocks exc. 10cm in width and set in cement mortar 1:6as specified and directed. |
| 24 | M&L for cement plaster rendering 10mm thick in cement mortar(1:4) on fair faces of brick/concrete surfaces, finished even and smooth without using extra cementcomplete all as specified and directed. |
| 25 | M&L Preparation of newly plastered surfaces of walls and applying two coats of white wash on wallsall as specified and directed. |
| 26 | Supply & Fix of GI tubing medium grade of size 100 mm bore with all fittings on wall/ trenches complete including cutting and thereading all as required at site complete all as specified and directed.Note:Excavation & earthwork shall be measured & paid seperately |
| 27 | Supply & Fix ofGI tubing medium grade of size 80 mm bore with all fittings on wall/ trenches complete including cutting and thereading all as required at site complete all as specified and directed.Note:Excavation & earthwork shall be measured & paid seperately |
| 28 | Supply & Fix of GI tubing medium grade of size 50mm bore with all fittings on wall/ trenches complete including cutting and thereading all as required at site complete all as specified and directed. Note:Excavation & earthwork shall be measured & paid seperately |
| 29 | S&FGun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 50mm complete all as specified and directed. |
| 30 | Supply & Fix ofGI tubing medium grade of size 25 mm bore with all fittings on wall/ trenches complete including cutting and thereading all as required at site complete all as specified and directed. Note:Excavation & earthwork shall be measured & paid seperately |
| 31 | S&FGun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 25 mm complete all as specified and directed. |
| 32 | Note :- An amount of Rs 0.00 on account of credit schedule for schedule \"A\" part II shall be deducted from the total amount of BOQ to arrive at the contract sum. |