| 1 | Excavation in trenches not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth and getting out for laying of cables up to proper level and laying of pipelines, foundation etcinsoft/loose soil, complete all as specified and directed. |
| 2 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed. |
| 3 | Removing surplus excavated material (soil) not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point, complete all as specified and directed. |
| 4 | Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983, complete all as specified and directed.Note :- (i)Excavated approved soil shall be ribbed by using sieve to separate composite particles etc. as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness shall be considered for payment. |
| 5 | Material and labour for well burnt bricks ‘B’ class as mechanicalprotection to under ground cables laying with length of the bricks equal to the width of the trench, complete all as specified and directed. |
| 6 | Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earthwork, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :-The tenderer shall take into consideration for following points while quoting rate for this item andthe unit rate is deemed to be inclusive for :-(i) Earth work and excavation in any type of soil(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick ,complete all as specified and as directed.(iii) Removing excavated material out side MD land.(iv)Laying of any type/any bore of pipe in trenches including taking down existing unserviceable pipe. Supply of pipe shall be measured and paid separately(v)150 mm thickPCC 1:2:4 type B1 using 20mm graded stone aggregate as inroad to make good existing disturbed surfaces. |
| 7 | Supply and fixing of GI pipe light grade for cable protection of size 100 mm bore with fittings, complete all as specified and directed. |
| 8 | Material and labour forBoring of holes under road, pavement hard standings by trenchless technology using ultra sound technique and necessary machine including supply of HDPE pipes upto 150 mm dia suitable for 0.4 Mpa working pressure, complete all as specified and directed. |
| 9 | Material and labour in repair for 3 ½ core 240 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole etc, complete all as specified and directed. Make : Havells, Polycab, RPG Asian |
| 10 | Material and labour in repair for 3 ½ core 185 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole etc, complete all as specified and directed. Make : Havells, Polycab, RPG Asian |
| 11 | Supply , fabricating ,installation,testing and commissioning75 KVAr APFC Panel out door type weather proof ,dust vermine proof (CPRI approved) APFC Panel made out of 3.00 mm thick CRCA sheet frontopenable type and suitable for operation on 415 Volts ,50 Hz ,AC supplyand fixed on angle iron frame /channel of suitable size complete ,aluminium bus bar ,cable gland brass chromium plated of different size suitable for incoming and out going cable. Panel Painted with powder coated paint including necessary PCC (1:3:6) foundation platform of suitable size infront of the panel complete all as specified and directed including taking down of old unsv panel of any description and comprising the following :-(a) MCCB 160 Amps 4 pole 25 KA- 01 No.(b)75 KVAr Capacitor8 Step with fitting fixture. (c) Digital Ameter with suitable size ofCT\"s- 01 No.(d) Digital Voltmeter -o1 No.(e) APFC Controller for minimum 8 Step-01 No.(f) Indicating Lamp RYBLED type as required.(g) Panel exhaust fan as required. |
| 12 | Supply, installation, testing and commissioning LTFeeder pillar box CPRI Testedof Size 800x600X450 mmsuitable for 3 phase 415 Volts of suitable size out door made out of 3.15mm thick CRCA sheet of panel with angle iron frame of size 50x50x6mm cubical type complete with aluminium bus bar 600 Amp and including PCC foundation in (1:2:4) type B-1 using 20mm graded stone aggregate as per site requirement to accomodate the following.INCOMING(a)MCCB 4 pole 400 Amp 25 KA - 01 No. (b)LEDindicating lampR-Y-B - 03 Nos.(c)Multifunction Meter (V,I,PF) with suitable capacity of CT\"s- 01 NoOUTGOING(a)Through Bus Bar |
| 13 | Material and labour for Dismantling of ACSR or AAC conductors complete all as directed. |
| 14 | Material and labour for Dismantling stay assembly complete all as directed. |
| 15 | Dismantling & taking down shackle/pin insulators of any size and type complete all as specified and as directed by Engineer-in-Charge. |
| 16 | M & L for laying of graded coarse aggregate (broken stone or boulders) of size 40 mm in sub - station yard evenly spreaded complete all as directed and specified. |
| 17 | Supply and fix new fabricatated high intensity standingHIP reflective sign board made from 2 mm thick harden plastic aluminium combined sheet and two sheets placed back to back fixed with aluminium pop rivited to stainless steel square pipe of size 40 x 40 mm of 16 guage and frame of size 1300 x 840 mm for E/M installations. The frame support shall be of 25 mm and 50 mm round GI Pipe 2.7 mtr length welded to frame. Top end of legs placed with decorative stainless steel dome of grade 304. HIP blue reflective sheet shall be pasted on both side on plastic aluminium combined sheet and pasted with weather proof white fluorescent computer cut tape of required height and width on sign board and border of white HIP sheet shall be pasted and fixed in PCC foundation (1:2:4) type B-1 complete all as directed (Note : Matter for printing shall be provided by the department) |
| 18 | Supply and fixing of GI pipe light grade for cable protection of size 80mm bore with fittings, complete all as specified and directed. |
| 19 | Material and labour in repair for 3 ½ core 95 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole etc, complete all as specified and directed. Make : Havells, Polycab, RPG Asian |
| 20 | Material and labour in repair for 3 ½ core 70 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole etc, complete all as specified and directed. Make : Havells, Polycab, RPG Asian |
| 21 | Supply, installation, testing and commissioning LTFeeder pillar box CPRI Testedof Size 800x600X450 mmsuitable for 3 phase 415 Volts of suitable size out door made out of 3.15mm thick CRCA sheet of panel with angle iron frame of size 50x50x6mm cubical type complete with aluminium bus bar 600 Amp and including PCC foundationin in (1:2:4) type B-1 using 20mm graded stone aggregate as per site requirement to accomodate to the following :-INCOMING(a)MCCB 4 pole 250 Amp 25 KA - 01 No. (b)LEDindicating lampR-Y-B - 03 Nos.(c)Multifunction Meter (V,I,PF) with suitable capacity of CT\"s- 01 NoOUTGOING(a)Through Bus Bar |
| 22 | Supply, fabricating, installation, testing and commisioning Feeder Pillar Box of factory assembled ,floor mounted ,free standing type tested LT Feeder pillar panels,with canopy ,as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycrabonate,should be weather, vermin proof, anti -acid,anti-corrossive,UV resistance in accordance with IEC 61439-1,fire retardant and self extingushing in accordance with IEC 60695-2-11 ,UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties ,RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tight to base with thermoplastic screw having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclouser should be above 200mm for air ciruculation & to minimize temp rise. Panel should be fitted with one No. ofpolycarbonate IP 65 9 W LED transperent bulk head luminaire 6500K,PF >0.95 under canopy for easy maintenance . Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 200 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggregate for bedding upto a height of 45 CM above ground level ,including dismantling and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board, complete all as specified and directed and comprising of the following :- |
| 23 | (a) MCCB with thermal magnetic release 4 Pole ,415 V of capacity 100 Amps ,25 KA- 02 Nos (Incomer).(b) On Load Change over front operated of capacity 125 Amp,4 Pole ,415 V -01 No.(c) MCCB with thermal magnetic release 4 Pole ,415 V of capacity 63 Amps ,10 KA- 01 No.(d) MCCB with thermal magnetic release 4 Pole ,415 V of capacity 40 Amps ,10 KA- 03 Nos.(e ) Multifunction Meter (V,I,PF) with suitable capacity of CT\"s- 01 No.(f) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set.(g) Space for spare feeder -01 No.Note :-(i)The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, wiring, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schenider/L&T/C&S.(iv) MCCB should be ICu = 100 % ICs .(v) Make of LT Panel /FPB shall be as mentioned in list of makes (PS). |
| 24 | Supply & Erecting Mild steel tubular swaged pole 9 meter long 410, SP-31 complete with cast iron base plate, bracket, finial taper plug, bolt, nuts & screws and painted on both side (internally & externally), external surface painted with two coat of aluminum paint over a coat of primer and painting with blackup to 1.5 meter from top of PCC 1:3:6 using 20 mm graded stone aggregate coping white colour paint as in strips of equal width with marking pole numbers by using one coat of synthetic enamel paint including necessary PCC 1:4:8 with 40 mm graded stone aggregate as in foundation as per TD drawing including dismantling of old damaged pole of any description complete all as specified and as directed. Note (i)Excavation, earth work and PCC work for embedding pole shall be measured and paid seperately.(ii) Pole upto 1.5 m top of copping shall be painted with 2 coats of black and white strips alternate 30cm each over one coat of red oxide primer (iii) Steel tubular pole above 1.5 m shall be painted with 2 coats of aluminium paint over a coat of red oxide primer. The rate for above items shall be deemed to be inclusive in the quoted rate. |
| 25 | Supply and fix in repair bracket for street light fitting made out of40 mm dia light grade GI tubing bent to required shape 1.5m long including necessary GI clamps, nuts bolts and washers and fixing to the pole etc complete all as specified and directed. |
| 26 | Supply and fix in repair weather proof PVC junction box approved by CPRI for street light control box made out of not less than 2mm thick and size 300x200x100mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No. panel mounted connector 4 pole 32A-1 No, MCB SP 6A 10KA-01No, including connecting up with the electrical connections and fixing with clamps etc complete and all as specified anddirected. |
| 27 | Supply, installation, testing and commissioning of smart street light control system using GSM/Lux based technology having20 KW 3 phase 64 Amp load capacity per phase and can be operated by IVRS/SMS/lux based infrared sensor etc complete with following:-(i) Nature switch operation should be based on natural light lux level. Require illuminnance level for switching on is ≤ 60 luxand for switching off ≥ 10 lux. The smart unit should have 4 timers that can be set via SMS.(ii)Surge protection device (SPD) should provide protection agaist indirect lightning & switching surges. It should conform to IEC61643-11 and should have 40 KA capacity.(iii) The sensor & SPD along with suitable power contactors and incoming-outgoing MCCB/MCBs should be enclosed in a enclosure made of rust proof, electric shock proof , metal weather proof conforming to IP65 with angle iron frame of suitable size 04 Nos legs 600 mm long , PCC 1:2:4 typeB1using 20 mm graded aggregate for grouting of base including taking down old unserviceable panel etc complete.The scope of work also comprising the following :-The GPRS shall have seven segment display to show voltage, current, network and street light status , it should also have indicator for showing supply status , timer , overload or high low voltage. It should also able to measure voltage, current and automatic set street light overload current. Unit have facility to call back to registered number for power on/off and if any fault occurs at site.in SMS it should also monitor power/on/off time light on off time, ampere, voltage, unit mode, network percentage date and mobile number who called device number. The device should also have battery backup with minimum 24 hours backup capacity.The panel should have three operation mode :-1. GSM mode -in this mode light should be switched as per GSM controller\"s preset time by user by sms , 4 clock base timer facility should be availble 2. Nature switch based-in this mode light will be switched as per nature light lux level 3. Bypass mode -in this mode light will switched on directly for testing purpose and emeregncy switching .In GSM controller there should be facility to register 4 user by sms/call and alerts will be sent on all registered number and also call back on power on/off and faults on first registered number.The GSM controller should also compatible for cloud based data transmission for interfacing with web for future use,Password protection for Accessing the control of device via SMS/IVRS, complete all as specified and directed including the following subcomponent, supply and fixing features :- |
| 28 | (a) TPN MCCB 100 Amps capacity, 10 KA, 415 Volts -01 No. (Incoming) with separate SPD of 40 KA capacity. (Make of MCCB- L & T, C&S Havells)(b)Supply Resign cast CT\"S - set of 3(c)GSM based smart street light controller.(d) Lux based sensor to operate external as per light intensity.(e)Line Contactor, AC 3duty, 3 phase, 415 volts. 50 Hz , 32 Amps -02 Nos (make - L & T, BCH, Havells)(f)MCB SP 32 Amps- 06 Nos(make -L & T, BCH, Havells)(g)Terminal block suitable for 100 Amp rating with brass contacts for INPUT/ and 63 Amp for OUTPUT termination.(h) GSM/Timer/Bypass Mode switch.(j) Panel wiring for control circuit with copper flexible 1.5 Sqmm & power wiring 10 Sqmm flexible.Make- Tricolite/ Kewintech/HPL |
| 29 | M &L for PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as in copping to poleincluding necessary form work slightly rounding or squaring, complete all as specifiedand as directed. |
| 30 | M & L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation and mass concrete for poles etc, complete all as specified and as directed |
| 31 | Supply and fixing in repair new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device of 70 watt complete all as specified and directed. Make:Halonix/Philips/CG/Bajaj |
| 32 | M&L for PVC/XLPE sheathed heavey duty power cable 1100 Volts grade copper conductor with latest amendents of size 1.5 Sqmm three Corefixed on pole/ walls including fixing arrangementcomplete as specified and directed. |
| 33 | Supply and fix informative sign board for E/M machineries, plants and Schematic diagrams made up of weather proof 3 mm thick rigid PVC sheet of dark blue back ground pasted on one side with white weather proof computer aided cut tape of required height pasted on sign board incl fixing arrangements by screw/ nut, bolt / riveting of the board in wall/panels/platform/doors/any description complete all as directed.(Note : Matter for printing shall be provided by the department ) |
| 34 | Supply and fixing GI pipe light grade for cable protection of size 50mm bore with fittings, complete all as specified and directed. |
| 35 | Material and labour in repair for 3.5 core 25 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole etc, complete all as specified and directed. Make : Havells/ Polycab/ RPG Asian |
| 36 | Material and labour in repair for 4 core 10 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole etc, complete all as specified and directed. Make : Havells/ Polycab/ RPG Asian |
| 37 | Supply, installation, testing and commissioning LTFeeder pillar box CPRI Testedof Size 800x600X450 mmsuitable for 3 phase 415 Volts of suitable size out door made out of 3.15mm thick CRCA sheet of panel with angle iron frame of size 50x50x6mm cubical type complete with aluminium bus bar 600 Amp and including PCC foundation foundationin in (1:2:4) type B-1 using 20mm graded stone aggregate as per site requirement to accomodate to the following :-INCOMING(a)MCCB 4 pole 63 Amp 25 KA - 01 No. (b)LEDindicating lampR-Y-B - 03 Nos.(c)Multifunction Meter (V,I,PF) with suitable capacity of CT\"s- 01 NoOUTGOING(a)Through Bus Bar |
| 38 | Supply, installation, testing & commissioning of maintenance free chemicalearthing system comprising of 17mm dia copper bondedrod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducingliquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed..Make : Model HTSP 317 of safeTrode or equivalent in Snaga/ Cubes 6 Global |
| 39 | The quoted rate shall also deemed to be included the following :- (i)Prior toinstallation of maintenance free chemicalearthing, soil resistivity test to be carried out at the location where earthingwork to be donein presence of Engr-in- Charge/JE (E/M),user and the report has tosubmitto Garrison Engineer with recommendation of manufacturer, if required additional interconnection ofearthing (not more than 08 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testingandsubmission of report with recommendationdeemed to be included in the quoted rate. |
| 40 | (ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors. |
| 41 | (iii) Rateofearth energizer compound of 25 Kg of 02 bags and earthresistance reducingliquid 10 litre per cane for each pit deemed to be included in the quoted rate. |
| 42 | (iv)Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor along with the sample approval |
| 43 | (v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete. |
| 44 | (vi) Copper strip of size 20 x 3 mm shallbe fixed on proper post insulator at the instrument end (copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately). |
| 45 | (vii)Testing of earth shall be carriedout in presence ofdepartmental and user representativeand report shall be submitted to Garrison Engineer duly signed by all concerned. |
| 46 | (viii)Earth resistance tester will be provided by the contractor.Tester should be calibrated from authorised company/ lab. |
| 47 | (ix)Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned.After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained. |
| 48 | (x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion. |
| 49 | (xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock. |
| 50 | (xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained. |
| 51 | (xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period. |
| 52 | (xiv) The electrode shallcarry manufacturer\"s name . |
| 53 | (xv) The connection clamp shall be permanentlly welded to the copper boundedrodto avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination. |
| 54 | (xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm. |
| 55 | (xvii)Earth work such as auguring andmaking good the surrounding area shall carried out in any type of soil. |
| 56 | (xviii)The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material. |
| 57 | (xix) Sign boardof mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxideZinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge. |
| 58 | M&L in repair Earth pit cover madeof heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mmfor each electrode pit, including taking down old u/s earth pit cover, complete all as specified and directed. |
| 59 | S&F in repair copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing old unserviceable copper strip of any description, complete all as specified anddirected. Note : - All Joints should be joined by Exothermic Welding or Brazing. |
| 60 | Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panel, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accordance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy oftype test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No.polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF >0.95 under canopy for easy maintenance. Panel shall be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32Amp 5P IP 65 industrial socket. 3 Phase and neutral 250 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggregate forbedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board complete all as specified and all as directed and comprising of the following:- |
| 61 | (a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 125 Amp, 36 KA - 01 No (Incomer). (b) On Load change over front operated of capacity 160 Amp, 4 Pole, 415 V- 01 No.(c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 10KA- 04 Nos.(d)MCB SPN of 240 V of capacity 40 Amps, 10 KA - 03 Nos.(e)Multifunction Meter (V,I,PF) with suitable capacity of CT\"s- 01 No(d) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (e) Space for spare feeder - 01 No. Note :-(i) The Contractor shall submit the drawing for approval of GE before executing the work.(ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S.(vi) MCCB should be ICu =100% ICs.(v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS). |
| 62 | Note :- An amount of Rs 88,260.00 on account of credit schedule for schedule \"A\" part II shall be deducted from the total amount of BOQ to arrive at the contract sum. |