| 1 | Excavating in post holes (or similar holes) each, not exc 0.50 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm thick in harde/ dense soil, complete all as specified and directed. |
| 2 | M&L for PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in foundation, foundation of fencing post holes and mass concrete, complete all as specified and directed. |
| 3 | M&L for rolled mild steel angle iron/ flat iron work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc. flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc. and similar work, conforming to Fe-410-W (Gde E- 250) Quality \"A\", complete all as specified and directed. |
| 4 | M&L for mild steel framed work such as grills, gratings, wicket gates, hold fasts etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work, conforming to Fe-290 Gde-E-165, complete all as specified and directed. |
| 5 | Supply only chain link fencing galvanised mild steel of any size and type, complete all as specified and directed. |
| 6 | Fixing only chain link fencing including line wires of any mesh, size and type to any type of standards, rails, straining bolts etc. including provission of binding wire, complete all as specified and directed. |
| 7 | S&F mild steel bolts, purpose made with hexagonal or square head at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 30cm long and dia of neck exc 12mm but not exc 20mm, complete all as specified and directed. |
| 8 | S&F rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment, conforming to Fe-410-W Gde-E-250 Quality \"A\",complete all as specified and directed. |
| 9 | S&F rolled mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats, special shaped washers etc. complete using ERW or induction butt welded tubes, conforming to Fe-410-W Gde-E-250 Quality \"A\",complete all as specified and directed. |
| 10 | S&F 0.50mm thick (AZ-150) prepainted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof coverings / cladding to walls, fixed with self tapping screws, complete all as specified and directed. |
| 11 | Surface excavation not exc 30cm deep and averaging 15cm deep and getting out in any type of soil, complete all as specified and directed. |
| 12 | Removing excavated material not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and directed. |
| 13 | M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in sub base of floor etc, complete all as specified and directed. |
| 14 | M&L for machine pressed rubber moulded, manufactured / compacted by vibrating table method precast concrete interlocking coloured paver block, lecquered finish, of any shape and size, confirming to IS:15658-2006 of 60mm thickness, M-35 grade with grey cement and pigments, complete all as specified and directed. |
| 15 | M&L for sand filling under floors, paver blocks or in foundations including watering, ramming and consolidation, complete all as specified and directed. |
| 16 | M&L for cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregates) as in roof kerbs or mud stops including rounded or chamfered on edges around paver blocks, complete all as specified and directed. |
| 17 | M&L for preparation of new steel/ iron surfaces of any description, over 10cm in width or girth and applying two coats of synthetic enameled paint over a coat of red oxide zinc chrome primer, complete all as specified and directed. |
| 18 | M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in foundations, filling in and mass concrete, complete all as specified and directed. |
| 19 | M&L for brick work with sub class \"B\" bricks, straight or curved on plan exceeding 6 metre mean radius, with using old size bricks, built in cement mortar 1:6, complete all as specified and directed. |
| 20 | M&L for 15mm thick rendering in CM 1:4 on faces of brick work or cement concrete surface, finished the surface even and fair without using extra cement, complete all as specified and directed. |
| 21 | M&L for preparation of new plastered surfaces of walls and applying two coats of cement based paint, white or tinted, over a coat of alkali resistant primer, complete all as specified and directed. |
| 22 | S&F in repair rigid non - metalic PVC casing caping of 25/12mm inclusive of all elbow, tees,etc complete all as per the direction of Engr-in-Charge. |