| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 22-12-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 29-12-2025 |
| Sl. No. | Item Description |
| 1 | Surface excavation not exceeding 30cm deep and averaging 15 cm deep and getting out in soft/loose complete all as specified and directed. |
| 2 | Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in soft/loose soil, complete all as specified and directed. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm, complete all as specified and directed. |
| 4 | Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed. |
| 5 | Excavation in post holes (or similar holes) each not exc. 0.50 cum, in hard and dense soil and getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exc. 25cm, watering and removal of excavated materials to a distance n. exc. 50m and making good surfaces, complete all as specified & directed. |
| 6 | Excavation over areas, n.exc 1.5 m deep andgetting out in any type of soil complete all as specified and directed. |
| 7 | Excavation over areas, exc 1.5 m deep but not exc 3 m deep andgetting out in any type ofsoil complete all as specified and directed. |
| 8 | Excavation over areas, exc 3 m deep but not exc 4.5 m deep andgetting out in any type ofsoil complete all as specified and directed. |
| 9 | Hard core of broken stone or boulders of gauge not exc 63 mm deposited ,spread and leveled in layer not exc 15 cm thick complete all as specified and directed. |
| 10 | Broken bricks, aggregate for loose filling, of gauge 80 mm to 150 mm graded as in soakage pit/ soakage wall complete all as specified and directed. |
| 11 | PCC 1:3:6 (nominal mix) type C-2(using 40mm graded crushed stone aggregates) as in foundation filling and mass concretecomplete all as specified and directed. |
| 12 | PCC 1:3:6 (nominal mix) type C-2(using 40mm graded crushed stone aggregates) as in surface channel and drainscomplete all as specified and directed. |
| 13 | Extra for formingfair finished drain or channel n.exc 30 cm inner girth in cement concrete using extra cement including forms, moulds mitred / stopped ends etc complete all as specified and directed. |
| 14 | Plain cement concrete 1:3:6 ( nominal mix ) type C-1 (using 20 mm graded crushed stone aggregates) as incopings andthe like including weathering, slightly rounded or chamfered angles and throatingincluding necessary formwork where required complete all as specified and directed. |
| 15 | RCC M-25 (Designmix) (using 20 mm graded crushed stoneaggregates ) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 16 | RCC M-25 (Designmix)(using 20 mm graded crushed stoneaggregates ) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 17 | Concrete bed to drain pipeof 150 mm bore including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) complete all as specified and directed.Note :- Thickness of bed and width of bed shall be provided all as per preamble a (i) & a (ii) on Srl page no 356 of SSR Part-II Rates (2010). |
| 18 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 toends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exc 10 cm but not exc 20cm in girth in stone conrete bolck or stone walls, complete all as specified. |
| 19 | Use & waste of form work to soffits of suspended slabs such as roof slabs, floor slabs landings and similar work, not exceeding 200mm thick (horizontal or sloping) for rough finished surfaces of concrete, complete all as specified & directed. |
| 20 | Use & waste of formwork to sides of concretefoundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batterfor rough finished surfaces of concrete flat, complete all as specified & directed. |
| 21 | Use & waste of form work to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc alo splays between floors and beamsfor rough finished surfaces of concrete, complete all as specified & directed. |
| 22 | Brick work with old size fly ash bricks, class 7.5, straight or curved on plan exc. 6 metre mean radius built in cement mortar 1:6 (01 cement : 06 coarse sand) all as specified & directed. |
| 23 | Brick work with old size fly ash bricks, class 7.5, straight or curved on plan exc. 6 metre mean radius built in cement mortar 1:4 (01 cement : 04 coarse sand) all as specified & directed. |
| 24 | Walling of random rubble stone masonry brought upto course well bonded bedded and soilidly hearted built in CM 1:6, complete all as specified and directed. |
| 25 | Factory made solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain coloured PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing on page No160 of MES SSR 2010 Part-II |
| 26 | Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of 5 mm thick plain coloured PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site,complete all as specified and directed. |
| 27 | Steel ventilator with top hung shutter including hinges, steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed. |
| 28 | Aluminium handles cast type anodizedof size 150 mm complete all as specified and directed. |
| 29 | Aluminium anodizedbarrel tower bolt of extruded section of size 200 mm and fixed complete all as specified and directed. |
| 30 | 100 size, Butt hinges, extruded aluminiumalloy with galvanised mild steel hinge pin, anodised and fixed, type B-21complete all as specified and directed. |
| 31 | Sheet glass, 4 mm thick ordinary quality and glazing with oil putty in squares n.exc 0.5 sqm each pane complete all as specified and directed. |
| 32 | Providing and fixing tiled false ceiling of size 595x595mm in true horizontal level suspended on interlocking gypric metal grid of hot dipped galvanized steel section (galvanized @ 120 gms/sqm, both side inclusive) consisting of 3600mm long main \"T\" runner size 24x38mm and 0.30mm thick, 1200mm long cross \"T\" of size 24x25mm and 0.30mm thick, 600mm secondary cross \"T\" of size 24x25mm and 0.30mm thick and PPGI wall angle of size 24x24mm and 0.4mm thick, bottom exposed capping of width 24mm of all T-sections shall be of 0.25mm thick PPGI, wall angle is fixed along the perimeters of the ceiling to walls, partitions or columns etc with rawl plugs and wooden screws at 300mm centers Main\"T\" runners are then suspended from ceiling using GI slotted cleats of size 27x37x25x1.6m fixed to ceiling with 8mm dia and 45mm long dashfasterners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85x30x0.8mm spaced at max 1200mm center to center along main T and not more than 150mm from spliced joints. The last hanger at the end of each main runner should not be greater than 600mm from the adjacent = wall, then 1200mm long cross \"T\" is interlocked between the main \"T\" at 600mm center to center to form a grid of 1200x600mm and then secondary cross \"T\" of length 600mm is then interlocked at middle of the 1200x600mm grid to form grids of 600x600mm. Cross tees at the ends having length more than 600mm are to be supported independently. Finally providing whitecoloured Gyproc 9mm thick Dew Drop/Granular tiles of size 595x595 having foil on back side & PVC paper on front side wrapped around edges to be placed in grid complete all as specified and directed. |
| 33 | Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified, all as specified and directed. |
| 34 | Prepainted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge, hips, valley/ eaves/ rain water gutters, drip and straight flashing (length and girthas fixed), fixed with self tapping screws all as specified |
| 35 | Rolled mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to grade Fe 410 -W (Gde-E- 250) quality-A, complete all as specified and as directed. |
| 36 | Rolled mild steel work as in Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etcconforming to grade Fe 410 -W (Gde-E- 250) quality-A, complete all as specified and as directed. |
| 37 | Framed work such as grills, gratings etc with ends of bars shouldered and/or riveted or forged into spikes framed guard bars including cutting, drilling, welding etc confirming to Fe-290 Gde E-165 all as specified and directed. |
| 38 | Mild steel TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed. |
| 39 | Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers bent to shape required, including cranking, bending spirally for hooping for columns, hooking endsand binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed. |
| 40 | 75mm thick PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregates) as in sub base complete all as specified and directed. . |
| 41 | 50mm thick PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregates)for septic tank ; surface finished even and smooth without using extra cement complete all as specified and directed. |
| 42 | 200 mm thick PCC 1:2:4 type B-2 (using 40 mm graded crushed stone aggregates)as in flooring of septic tankfinish,surface finished even and fair complete all as specified and directed. |
| 43 | 40 mm thick PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregates)as in flooring & roof finish,surface finished even and smooth without using extra cement complete all as specified and directed. |
| 44 | Plain cement concrete , 1:3:6, nominal mix, type C-1, using 20mm graded mechanically crushed stone aggregate, 75mthick as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen VG-10 and two parts of heated coarse sand (by volume), all as specified. Note:- The unit rate include for use of form work (straight or curved). |
| 45 | Mat finish, premium quality, joint free (edge cut), coloured/ printed ceramic tiles 10 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm,as inskirting , dados ,vertical surfacesetc , set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tile over and including 15 mm thick cement screed in cement mortar 1:4 including necessary cutting and waste as per site requirement pointed in white or coloured cement to match complete all as specified and directed. |
| 46 | Glazed ceramic colouredtilesof size450 mm x 350 mm x7 mm/350 mm x 250 mm x7 mm thick as in vertical surfaces , set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tile over and including 10 mm thick cement screed in cement mortar 1:3 complete all as specified and directed. Size/Shade/Colour of tile shall be approved by the GE. |
| 47 | 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, over and including 15 mm thick screed base in cement mortar 1:6 over andcomplete all as specified and directed. |
| 48 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified. |
| 49 | Chequered cement concrete colouredtiles, homogenious texture glossy finished, chemically coated machine pressed 30 cm x 30cm x 25mm thick set, jointed and pointed in near cement slurry in floor with gray cement and pigment and including 15 mm thick cement screed in cement mortar 1:4 over complete all as specified and directed. Shade/Colour of tile shall be approved by the GE. |
| 50 | Bricks, sub class B, laid flat, in floors, oldsize bricks, bedded and jointed in cement mortar 1:6 and pointed in cement mortar 1:6, complete all as specified. |
| 51 | Rendering cement plaster 20mm thick in cement mortar 1:3 (1 cement : 3 coarse sand) in two layers (10mm thick first layer and 5mm thick second layer) on other than fair faces of brick wall or on stone masonry surfaces, for walls of septic tank, trowelled to even and smooth finish without using extra cement complete all as specified. |
| 52 | Rendering cement plaster 10mm thick in cement mortar 1:6 (1 cement : 6 coarse sand) in two layers (5mm thick first layer and 5mm thick second layer) on other than fair faces of brick wall or on stone masonry surfaces,, trowelled to even and smooth finish without using extra cement complete all as specified. |
| 53 | Rendering cement plaster 15mm thick in cement mortar 1:4 (1 cement : 4 coarse sand) in two layers (10mm thick first layer and 5mm thick second layer) on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified. |
| 54 | Preparation of new steel surfaces of any description, over 10cm in width or girth,not otherwise describedand applying two coats of synthetic enamel paint over a coat of red oxide primercomplete all as specified and directed. |
| 55 | Preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed. |
| 56 | Three coats of white wash on newly plastered or un plastered, previously undecoratedwall surfaces including preparation of surfaces complete, all as specified. |
| 57 | Preparation ofnewplastered surfaces or un plastered, previously undecorated wall surfaces and applyingtwo coats of cement base paint, complete all as specified and directed. |
| 58 | G I tubingmedium gradeof 15 mm borewith all fittings and fixtures fixed to wall and ceiling or laid infloor/trenches complete all as specified and directed. |
| 59 | G I tubingmedium gradeof 20 mm borewith all fittings and fixtures fixed to wall and ceiling or laid infloor /trenches complete all as specified and directed. |
| 60 | G I tubingmedium gradeof 25 mm borewith all fittings and fixtures fixed to wall and ceiling or laid infloor /trenches complete all as specified and directed. |
| 61 | G I tubingmedium gradeof 40 mm borewith all fittings and fixtures fixed to wall and ceiling or laid infloor /trenches complete all as specified and directed. |
| 62 | 150mm bor , Salt-glazed stoneware drain pipes, Grade \"A\" laid in trenches and jointedcomplete all as specified. |
| 63 | Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 190gms)complete all as specified |
| 64 | Aluminium anodised tubular towel rail, 20mm dia , 60 cm long , with a pair of brackets , fixed to wall with CP screws and PVC rawl plugs , complete all as specified |
| 65 | Chromium plated soap dish, fixed to plugs with chromium plated brass screws complete all as specified. |
| 66 | Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms), complete all as specified. |
| 67 | Swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms) with Shower arm 15 mm size, 195mm long with bend of 45degree with flange of PTMT any colour.(Minimum weight 40gms), complete all as specified. |
| 68 | Wash basins, Vitreous China (Flat white type) size 550mmx400mm, crystal white with and including cutting for and pinning on ends of brackets, 450 mm long PVC connections 15mm size with PTMT coupling nuts at both ends, trap, grating and Union for discharge pipe, waste, chain and plug and porcelain stopper, waste pipe of polythylene of low or high density or PVC of 32mm dia including Pillar taps, 15mm bore cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot\" or ‘Cold\" with long screwed shanks and fly-nuts, 32mm dia waste fittings, brass chromium plated with long screwed shanks and fly nuts, flange and bedded in red lead cement and other end fixed, screwed for iron pipe and fixed, completeall as specified. Make: Cat Part No. 1008 of Cera or equivalent in makes mentioned in Appx \"C\" |
| 69 | Wash basins, Vitreous China , oval shaped , counter,size 560mmx470mmx190mm, colouredincluding cutting of top, 450 mm long PVC connections 15mm size with PTMT coupling nuts at both ends, trap, grating and Union for discharge pipe, waste, chain and plug and porcelain stopper, waste pipe of polythylene of low or high density or PVC of 32mm dia including Pillar taps, 15mm bore cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot\" or ‘Cold\" with long screwed shanks and fly-nuts, 32mm dia waste fittings, brass chromium plated with long screwed shanks and fly nuts, flange and bedded in red lead cement and other end fixed, screwed for iron pipe and fixed, completeall as specified. Make: Cat Part No. S2030104of Cera or equivalent in makes mentioned in Appx \"C\" |
| 70 | Vitreous china urinal, half stall type,white, including fixing bolts, flush pipe, PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, capacity 7.0 litre, PVC waste pipeincluding providing and fixing plugs,including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe, complete all as specified and as directed. |
| 71 | Stop/Angle valves, cast copper alloy, chromium plated, fancy type, screwed down,high pressure ,screwed both ends for 15mm bore iron pipe or for unions irs complete, all as specified. |
| 72 | Stop valves cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unionsfor 15mm bore iron pipe or for unions, complete all as specified. |
| 73 | Bib tap, cast copper alloy ,chromium plated, fancy type , screwed for iron pipe or for brass ferrule of 15 mm bore complete all as specified and directed. |
| 74 | Gun metal globe orgate valve with iron wheel head, screwed both ends for iron pipe and fixedbore dia of pipe 15mm complete all as specified and directed. |
| 75 | Gun metal globe orgate valve with iron wheel head, screwed both ends for iron pipe and fixedbore dia of pipe 20 mm complete all as specified and directed. |
| 76 | Gun metal globe orgate valve with iron wheel head, screwed both ends for iron pipe and fixedbore dia of pipe 25mm complete all as specified and directed. |
| 77 | Gun metal globe orgate valve with iron wheel head, screwed both ends for iron pipe and fixedbore dia of pipe 40mm complete all as specified and directed. |
| 78 | Ball brass valves, 20mm bore high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed, complete all as specified. |
| 79 | PVC connections 15 mm size with PTMT nutsof length 450mm ,complete all as specified and directed. |
| 80 | Vitreous China wash down water closet (pedestal pattern), white including traps, connection to drain or outgoing pipe, flushing pipe, anti-syphonage pipe complete including fittings, including PVC connection, fixedcomplete and provision of plain cement concrete M-15, type B-I, using 20mm graded crushed stone aggregate, all as specified. Make: Cat Part No. 2008 for EWC, 2308 for seat cover, 2201/B for internal fittings of\"Cera\" or equivalent in makes mentioned in Appx \"C\" |
| 81 | PVC valve less, crystal white, syphonic action type flushing cistern 10 litre capacity, superior quality, plunger type, low level, with inlet, ball valve, float and handle, 32 mm dia PVC long bend flush pipe 90cm long and 15 mm dia 600 mm long PVC connection with CP brass coupling nuts and PVC washers at both ends fixed, in repairs, all as specified. Make: Cat Part No. 2602 ofCera or equivalent in makes mentioned in Appx \"C\". |
| 82 | 600x450 mm bevelled edge mirror of slected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plug with chromium plated brass screwed and cup washers, complete all as specified. |
| 83 | Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 84 | 110mm dia PVC(SWR)pipe single socketed with rubber ringjoints, laid in trenches or in floor complete all as specified and directed. |
| 85 | 75mm dia PVC(SWR)pipe single socketed with rubber ringjoints, laid/fixed to trenches or in floor, complete all as specified and directed. |
| 86 | 75mm dia PVC(SWR)pipe single socketed with rubber ringjoints, fixed to walls, complete all as specified and directed. |
| 87 | 110 mm dia PVC(SWR) bend, any radius complete all as specified and directed. |
| 88 | 75 mm dia PVC(SWR) bend, any radius complete all as specified and directed. |
| 89 | 75 mm dia PVC(SWR) bend, any radius fixed with oval access door complete all as specified and directed. |
| 90 | 75 mm dia PVC(SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 91 | PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement, complete all as specified. |
| 92 | 75 mm dia PVC(SWR) vent cowl complete all as specified and directed. |
| 93 | 110 mm dia PVC(SWR) vent cowl complete all as specified and directed. |
| 94 | 75mm dia PVC (SWR) junction single, (single T) equal or unequal provided with oval access door complete all as specified and directed. |
| 95 | 110mm dia PVC (SWR) junction double, (double T) equal or unequal provided with oval access door complete all as specified and directed. |
| 96 | 75mm dia PVC (SWR) junction double, (double T) equal or unequal provided with oval access door complete all as specified and directed. |
| 97 | Rotational moulded polyethylene water storage tank 1000 Ltrs capacity four layered (ISI Marked) cylinderical vertical with closed top, hoisted and fixed in position with ball brass valve, high pressure with PVC float valve 25mm dia with polythene float and fly nut, tank nipples with check nuts and washers complete and making connections with existing water supply line complete all as specified. |
| 98 | Rotational moulded polyethylene water storage tank 500 Ltrs capacity four layered (ISI Marked) cylinderical vertical with closed top, hoisted and fixed in position with ball brass valve, high pressure with PVC float valve 25mm dia with polythene float and fly nut, tank nipples with check nuts and washers complete and making connections with existing water supply line complete all as specified. |
| 99 | Point wiring for one light/fan/call bell point controlled by one 5/6 Amp switch with 1.5 Sqmm two single core multistranded copper conductor FRLSH, PVC insulated (unsheathed) heavy duty cable 1100 volts including continuous earth wire of size 1.5 Sqmm copper conductor multistrand FRLSH, PVC insulated (unsheathed) drawn into concealed rigid non-metallic PVC conduit Medium Grade ISI marked not less than 20mm wide of 1.8mm wall thickness ISI marked including modular GI sunken flush box (Pressed steel powder coated Modular GI sunken flush boxese of any way i.e. 1 to 12 way as per site requirement suitable for modular switch/socket) for mounting switches,sockets, fan regulators etc & making good to disturbed surfaces as well as matching with existing whitewash colour/surface complete all as specified and as directed for the following:- (a)Wiring shall be done by using proper colour coding(b)Earth wire shall be of green colour(c)On RCC roof/ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed. |
| 100 | All as per serial item No \"99\" above, but for one 3 pin 5 Ampssocket outlet on the same board all as specified and directed. |
| 101 | All as per serial item No \"99\" above, but for one 3 pin 5 Ampssocket outlet, independent all as specified and directed. |
| 102 | All as per serial item No. \"99\" above but for 3 pin 15 Amps socket out letindependentwith 4 Sqmm PVC copper conductor cable and and PVC insulated, unsheathed 4 Sqmm stranded copper conductor cable as continuous earth wire, all as specified. |
| 103 | Modular White cover plate with frame, 8 module, complete all as specified. |
| 104 | Modular White cover plate with frame,3 module, complete all as specified. |
| 105 | Modular switch 1 way 6A, 1 module complete all as specified and directed. |
| 106 | Modular socket, 6A-2/3 pin combined 2 module complete all as specified and directed. |
| 107 | Modular socket, 6A and 16A, 2/3 pin combined 2 module complete all as specified and directed. |
| 108 | Modular switch 1 way 16A, 1 module complete all as specified and directed. |
| 109 | Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings , all as specified. |
| 110 | Ceiling rose, 65 mm to 50 mm, two to three terminals, PVC/ Polycarbonate, insulated body fixed on PVC block, all as specified. |
| 111 | Sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 8 way, double door, 240 volts with 200 Amp rated bus barall as specified. |
| 112 | Sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 4 way, double door, 240 volts with 200 Amp rated bus barall as specified. |
| 113 | LED lamps, 15 watts, CDL , B-22 cap (pin type) , PF not less than 0.85 (min),all as specified and directed. |
| 114 | Wall Mounted mirror light LED fitting , 10/11/14 watt, 2 feet long including integrated electronic driver , complete all as specified. |
| 115 | Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack , 10 watt LED,6500k, two feet long, with all acessoreis internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable sizeincluding dismantling of unserviceable tube light all as specified and directed.Make: Havell\"s Cat Part No. LHEXACP7IN1W010 of\"Havells\" or equivalent in makes mentioned in Appendix |
| 116 | LED type tube light, 1x20 watt 230 volts wall mounted Inverter LED batten with square profile and polycarbonate channel. Lithium Ion battery with charging time 8hours-10 hours and back up time upto 4 hours,internely pre wired and including connecting up with three core twisted flexible copper conductor cable of suitable size. Make: Havells cat part No. LHEXACP7FN1W020 or equivalent in Appx |
| 117 | MCB SPN 40 to 63 Amp, 240 Volts, 10 KA , C Curve all as specified. |
| 118 | MCB SP 6 to 32 Amp, 240 Volts, 10 KA, C Curve, all as specified. |
| 119 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece including 02 Nos PVC connection , heavey duty 15mm bore ,3 core copper cable with plug top 15 Amp, fixed in poistion with 04 Nos bolts of suitable size etc. all as specified and directed. |
| 120 | Exhaust fan, steel body heavey duty,AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers including connecting up complete with 3 core flexible cord cable of size 27/0.183 from ceiling rose to connector of fan complete including cutting hole and fixing arrangement on wallall as specified and directed. |
| 121 | Exhaust fan, steel body heavey duty,AC single Phase. 230V of size 200mm sweep with, blades, and frame and louvers including connecting up complete with 3 core flexible cord cable of size 27/0.183 from ceiling rose to connector of fan complete including cutting hole and fixing arrangement on wallall as specified and directed. |
| 122 | Sand cushioning to under ground cables provided with a layer of sand 8 cms thick before laying the cable and 15 cms thick after laying the cable complete all as specified and directed. |
| 123 | Sub class \"B\" bricks for covering to cable laid dry flat, with width equal to length of bricks all as specified and directed. |
| 124 | GI pipe light grade of size 40 mm dia laid in trenches/ walls including clamps, screws etc, complete all as specified and directed. |
| 125 | XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100volts grade, cross-sectional area 16 sq. mm, 2 core, complete all as specified. |
| 126 | XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100volts grade, cross-sectional area 10 sq. mm, 2 core, complete all as specified. |
| 127 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension GI wire, one twin core cable flat or circular, 6 Sqmm Stranded conductor, complete all as specified. |
| 128 | Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC M-15, type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC M-15, type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixingarrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electricalplate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. |
| 129 | Construction of Brick Masonry Valve Pit of sizes 900 x 900 x 900mm , one Brick thick wall in cement mortar 1:4 on 100mm thick PCC 1:4:8 (40mm graded aggregate) in Foundation, Rendering 15mm thick internally and externally upto 150mm below GL, providing 3.15mm thick MS Sheet Valve Pit Cover, welded with 40X5mm Flat Iron Frame alround including provision of Hinges, Handle and Locking Arrangement and 40 x 40 x 6mm Angle Iron Frame fixed on Top of Valve Pit by means of Holdfast 150mm long, embedded in PCC 1:2:4 (20mm graded aggregate) Block of size 230 x 200 x 100 mm, applying two coats of Anti-corrosive Paint over a coat of Red Oxide Zinc Chrome Primer after preparation of all exposed to Steel Surfaces including necessary Earth Work in Soft/Loose Soil ,complete all as specified and asdirected. |
| 130 | Construction of Brick Masonry Valve Pit of sizes 600 x 600 x 600mm , one Brick thick wall in cement mortar 1:4 on 100mm thick PCC 1:4:8 (40mm graded aggregate) in Foundation, Rendering 15mm thick internally and externally upto 150mm below GL, providing 3.15mm thick MS Sheet Valve Pit Cover, welded with 40X5mm Flat Iron Frame alround including provision of Hinges, Handle and Locking Arrangement and 40 x 40 x 6mm Angle Iron Frame fixed on Top of Valve Pit by means of Holdfast 150mm long, embedded in PCC 1:2:4 (20mm graded aggregate) Block of size 230 x 200 x 100 mm, applying two coats of Anti-corrosive Paint over a coat of Red Oxide Zinc Chrome Primer after preparation of all exposed to Steel Surfaces including necessary Earth Work in Soft/Loose Soil ,complete all as specified and asdirected. |