| 1 | Earthing complete with galvanized steelearth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge o the plate not less1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts nuts, check nuts and washers of galvanized iron of steel all as shown in electrical plate No.3 connected to earthing test point incl necessary earth work, excavation PCC 1:3:6 type CI using 20mm graded stone aggregate for earth chamber provn of PCC cover 40 mm thick 1:2:4 mm type B1 funnel with water Pipe, GI pipe, 15mm dia medium grade protection pipe, GI earth lead complete all as specified and directed by the Engr-in-charge. |
| 2 | Taking down carefully existing point wiring of any description for (light, fan ,sockets bells etc) complete including fittings such as sunken boxes, switches, sockets, ceiling rose, lamp holders, brackets ,fittings, pendants, fan regulartors etc and making good the disturbed surface of walls, floors etc. all as specified and directed. |
| 3 | Taking downexisting sub main wiring /Service wire of any description and size including earth wire, batten, conduits and making good the disturbed surfaces ofwalls, floors etc. |
| 4 | M&L Point wiring for one light point/fan point/bell point controlled by one switch with 1.5 sqmm multistrand copper conductor cable PVC (FRLSH) insulatedunsheathed copper conductor single core multi stand flexible cable and 1.50 sqmm PVC (FRLSH) insulated unsheathed copper conductor single core cable( green colour) as earth lead in and including PVC rigid conduit with all fittings for concealed/surface type on stone / brick, masonary walls, roof etc including new CI/MS sunken box of required size and all as directed by Engineer-in-Charge & 3 mm thick plastic laminated sheet for housing switches sockets, regulators etc. including making good the disturbed surfaces during cutting/running chases, pinning in to match with the existing specification, complete all as specified and directed at site.Note : Cutting/running chases, pinning in shall be measured seperately for concealed point wiring ( One Concealed Point wiring shall be measured as 2.5 RM Cutting/running chases, pinning in. |
| 5 | All as per item no.04 but One 3 pin 5/6 Amps switch socket outlet on independent board complete all as specified and directed by the Engr-in-charge. |
| 6 | All as per item no.04 but One 3 pin 5/6 Amps switch socket outlet on sameboardcomplete all as specified and directed by the Engr-in-charge. |
| 7 | All as per item no.04 but for One 3 pin 15 / 16 Amps switch socket outlet point on independent board with 2.5 sqmmPVC (FRLSH) insulatedunsheathed copper conductor single core multi stand flexible cable and 2.5 sqmm PVC (FRLSH) insulated unsheathed copper conductor single core cable (green colour) as earth lead complete all as specified and directed by the Engr-in-charge. |
| 8 | M & L for providing point wiring with 1.5 sq. mm (nominal area) single core PVC insulated FRLSH unsheathed multi-stranded copper conductor cable (maintaining colour code), 1100 volts grade in and includingnon metalic rigid PVC conduit medium grade with appropriate size with all fittings (ISI Marked) suitable for concealed wiringon stone/brick, masonary walls, roof etcincluding modular sunken box of adequate size with suitable modular plate cover for mounting modular switches, sockets, regulators, light fittings etc. complete with all fittings and accessories fixed to wall/ ceiling for one light/ fan /bell point controlled by one oneway modular switches including one run 1.5 sqmm (nominal area) PVC insulated FRLSH unsheathed multi-stranded copper conductor cable green in colour for earth continuity conductor connected to common earth dolly including cutting/running chases, pinning in and making good the disturbed surfaces to match with the existing specification, complete all as specified & directed at site. |
| 9 | All as per Item No.8 abovebut one 5 Amps 3/5 pin modular socket outlet on independent board complete all as specified and as directed at site. |
| 10 | All as per Item No.8 above but for one 3/5 pin 5/6 Amps modular socket outlet point on same board with other switches complete all as specified and as directed at site. |
| 11 | All as per item no:8 but for One 3 pin 15 / 16 Amps modular switch socket outlet point on independent board with 2.5 sqmmPVC (FRLSH) insulatedunsheathed copper conductor single core multi stand flexible cable and 2.5 sqmm PVC (FRLSH) insulated unsheathed copper conductor single core cable (green colour) as earth lead complete all as specified and directed at site. |
| 12 | S&F in repair switch piano flush type single pole one way 5/6 Amps complete all as specified and directed at site. |
| 13 | S&F in repair switch socket combination flush type 5/6 Amps Multipurpose 2 in 1, 3 pin/5 pin with porcelain base complete all as specified and directed at site. |
| 14 | S&F in repair switch socket combination 2 in 1 flush type universal 3 pin 5 & 15 Amps complete all as specified and directed at site. |
| 15 | S&F in repair lamp holder insulated body with back plate suitable for battern fittings complete all as specified and directed at site. |
| 16 | S&F in repair Ceiling rose surface bakelite 65 x 50 mm 2/3 terminals complete all as specified and directed at site. |
| 17 | S&F in repair Fan Regulator (Rotary step type, Switch/Socket type Dimmer) 230/240V, AC complete all as specified and directed at site. |
| 18 | S&F in repair Bell push, flush type, 5 Amps complete all as specified and directed at site. |
| 19 | S&F in repair Modular switch, single pole, one way, 6Amps one module complete all as specified and as directed. |
| 20 | S&F in repair Modular 6A 3 pin universal socket outlet, 2 module complete all as specified and as directed. |
| 21 | S&F in repair Modular switch, single pole, one way, 16Amps one module complete all as specified and as directed. |
| 22 | S&F in repair Modular socket outlet 2-in-1, 6/16 Amps, 2 module complete all as specified and as directed. |
| 23 | S&F in repair modular stepped type electronic fan regulator 220 volts, 100Wattcomplete all as specified and as directed. |
| 24 | S&F in repair modular bell push 6 Amps 1 module complete all as specified and as directed. |
| 25 | S&F in repair Factory made Prewired TPN 4 ways distribution board in sheet steel enclosure vertical double door with suitable ratedbus bar, 240 Volts suitable for housing TPN MCBs as incomer and SP MCBs as outgoing complete all as specified and as directed. |
| 26 | S&F in repair Factory made SPN 8 ways distribution board in sheet steel enclosure vertical double door with suitable ratedbus bar, 240 Volts suitable for housing SPN MCBs as incomer and SP MCBsas outgoing complete all as specified and as directed. |
| 27 | S&F in repair Factory made SPN 4 ways distribution board in sheet steel enclosure vertical double door with suitable ratedbus bar, 240 Volts suitable for housing SPN MCBs as incomer and SP MCBsas outgoing complete all as specified and as directed. |
| 28 | S&F in repair MCB,Four pole,240 volts, 63 Amps 10 KA C curve complete all as specified and as directed. |
| 29 | Supply and fix RCBOs SPN 32 Amp, 240 volts 50Hz AC supply, complete all specified and directed. |
| 30 | S&F in repair 240V, 10 KA \"C\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed at site. |
| 31 | M&L for Submain wiring with two single core PVC (FRLS) insulated flexible copper conductor cable of size 6 Sqmm and one single core PVC (FRLS) insulated unsheathed flexible copper conductor cable green colour of size 6.0 Sqmm as earth lead in and including PVC conduit medium grade/casing caping with all fittings suitable for concealed/surface type and making good the disturbed wall surfaces to match with existing specification all as required at site complete all as specified and directed at site. |
| 32 | Supply and fix in repair 35W energy saving and environmental friendly long life LED building security street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08, 10KV surge protection and having 130 lumen/watt including connection with twin twisted unsheathed PVC copper cable of suitable size alongwith suitable brackets with clamps, nuts and bolts complete all as specified and directed.Make : Havells Cat No. ENDURASUNDOWNSL35WLED 765PASYBOPC or approved equivalent make. |
| 33 | Supply and fix in repair LED lights fitting 1x 20W, 220V, AC decorative box type with powdered coated aluminium housing & integrated electronic driver with THD<10%, 4KV surge protection and 130 lumen/watt including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.Make : Havells Cat No. LUMILINEPLUSNEOBS20WLED865SPCSSIND or approved equivalent make. |
| 34 | Supply and fix in repair LED lights fitting 1x 10W, 220V, AC decorative box type with powdered coated aluminium housing & integrated electronic driver with THD<10%, 4KV surge protection and 130 lumen/watt including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.Make : Havells Cat No. LUMILINE+BS10WLED865SPCSS or approved equivalent make. |
| 35 | S&F in repair CITY 3 Decorative wall light fixture made up of Polycarbonate, suitable for and including 9 W retrofit LED Lamp B22 base. complete all as specified and directed at site.Make : Havells / Bajaj / Crompton Greaves. |
| 36 | S&F in repair 15W surface mounted LED slim round downlighter with high efficient LEDs & glare free opal diffuser, IP20 with integrated electronic driver including necessary connection all as specified and directed at site.Make : Havells Cat No. INTEGRANXTRDDLRSURD15WLED840S or approved equivalent make. |
| 37 | Supply & fix in repair LED down lighter 2\"x2\" , 34 Wenvironmental friendly, new generation,aesthetically designed, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source, suitable for Armstrong/Grid ceiling complete all as specified and directed.Make : Havells Cat No. PLANO2X2PLR34WLED865S or approved equivalent make. |
| 38 | S&F in repair 15W Coral LED Post Top gate light, IP 65 suitable for pole dia 50mm Eenergy saving enviromental friendly ,long life aesthetically design with symattetrically distrubution of light ,spun aluminiam land scape luminaire with high power LED s complete all as specified and directed at site. Make- RUMYMINIPT15w LED OF HAVELLS AND EQUILLENT |
| 39 | S&F in repair LED light fittings, 1x10 watts bulk head luminaires, IP66 complete with all accessories and including connecting up with twin core twisted flexible PVC copper conduct cabe of 23/0.0076 from ceiling rose all as specified. |
| 40 | S&F in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 Amps MCB complete all as specifed and directed at site. |
| 41 | S&F in repair bell ding dong AC single pole 230 volts complete all as specified and as directed at site. |
| 42 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor of size 10 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspen- ded by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and directed at site. |
| 43 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor of size 16 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspen- ded by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and directed at site. |
| 44 | M&L for Submain wiring with two single core PVC (FRLS) insulated flexible copper conductor cable of size 4 Sqmm and one single core PVC (FRLS) insulated unsheathed flexible copper conductor cable green colour of size 4.0 Sqmm as earth lead in and including PVC conduit medium grade/casing caping with all fittings suitable for concealed/surface type and making good the disturbed wall surfaces to match with existing specification all as required at site complete all as specified and directed at site. |
| 45 | Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings steps, cills, sunshades, shelves, lintels,etc, and cutting chases for concealed water tubing or concealed conduit wiring etc and making good cutting not exc 10 cm grith complete all as specified and directed at site. |
| 46 | Disconnecting and removingceiling fan fromany height from electrical connection bringing down, dismantling, cleaning internally and externally thoroughly examine & replacement of split pins, cotter pins and check nuts etc overhauling, lubricating with approved lubricants, reassembling, includingreplacement of wornout/defective parts, refixing in original position includingminor repairs for the smooth functioning and provision of new flexible wire of size 23/0.0076 multistranded copper conductor cable from ceiling rose to fan including testing complete all as specified. NOTE:- (1)Necessaryreplacement of unserviceable parts/winding shall be measured and paid seperately.(2)Labour element for replacing of unserviceable parts deemed to be included in rate quoted. |
| 47 | Supply only oil filled Capacitor, 2.5 mfd suitable for ceiling fan |
| 48 | Supply only Ball bearing suitable for ceiling fans including necessary greasing. Make: NBC/SKF/TATA |
| 49 | Supply only bushing suitable for ceiling fans /wall mounting fan/ exhaust fan. |
| 50 | Supply only Rubber bush with clamp, nuts and bolts for ceiling fan . |
| 51 | Supply only shaft made out of carbon steel including necessary lathe work for ceiling fan. |
| 52 | Taking out defective winding andrewinding of the ceiling fan of any sweep complete with equivalent new super enamelled copper wire as per existing gauge and weight as per manufacturer\"s design and instructions including varnishing of ceiling fan of any make and any sweep complete all as specified and directed |
| 53 | Supply and fix 1.5 Sqmm Copper wire single core with complete all as specified and directed at site. |
| 54 | Supply and fix 2.5 Sqmm Copper wire single core with complete all as specified and directed at site. |
| 55 | Supply and fix 4 Sqmm Copper wire single core with complete all as specified and directed at site. |
| 56 | Supply and Fix 40W, decorative, wall mounted, ultra slim, polycarbonate, LED lighting fixture, (1205 x 66 x 76)mm, 6500K, with high lumen output, environmental friendly, energy efficient with electronic driver complete all as per Cat No. STOUTPLUS600BS40WLLED840SPCWHof Havells or techno-commercially equivalent of other specified makes with all fixing arrangement etc., complete all as specified and as directed. |
| 57 | S & F Mild steel rod for ceiling fans of 3 feet long duly screwed threads with check nuts & pin for celing fan complete all as specified and directed |
| 58 | S & F Mild steel rod for ceiling fans of 5 feet long duly screwed threads with check nuts & pin for celing fan complete all as specified and directed |
| 59 | S & F hanging hooks for fixing the fansNote : (a) For Item No.12 to 44, and 57 to 59Contractor\"s supervisor / elect has to collect complaint slip/Job card from complaint cell, attened the complaint and complaint should be rectified on same day after receiving the complaint.(b)For Item No. 46 to 53 repair/rewinding of ceiling fans shall be done at AGE E/M Subdivison only. |