| 1 | SCHEDULE \"A\" PART-I : BOQ OF WORKS FOR B/R WORKS. |
| 2 | Taking up or down steel tubing of 15mm bore pipe an connection, including cleaning for re-fixing or removal to store, complete all as specified and as directed. |
| 3 | Supplying and laying of CPVC pipes SDR 11 and Plain CPVC SDR 11, having outer dia 16mm, including fittings and fixing on walls/ ceiling or laying in floors, along with required cutting/ chasing grooves in wall, complete all as specified and as specified. |
| 4 | Old tubes, \"any grade\" galvanised, 15mm bore, ISI markedwith all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and as directed.Note: Cost of cutting/ chasing for pipe line making concealed in surfaces shall be deemed included in quoted rates. |
| 5 | Taking up or down steel tubing of 20mm bore pipe an connection, including cleaning for re-fixing or removal to store, complete all as specified and as directed. |
| 6 | Supplying and laying of CPVC pipes SDR 11 and Plain CPVC SDR 11, having outer dia 20mm, including fittings and fixing on walls/ ceiling or laying in floors, along with required cutting/ chasing grooves in wall, complete all as specified and as specified. |
| 7 | Old tubes, \"any grade\" galvanised, 20mm bore, ISI markedwith all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and as directed.Note: Cost of cutting/ chasing for pipe line making concealed in surfaces shall be deemed included in quoted rates. |
| 8 | Rotational moulded polyethylene water storage tanks of 500 liters capacity, (cylindrical vertical with closed top) with lid, hoisted and fixed in position all as specified in SSR Part-I including ball valves high pressure of PTMT with epoxy coated aluminium rod and highdensity plastic ball screwed for iron pipe and fixed for 20mm bore pipe, fixing in repairs, complete all as specified and as directed. |
| 9 | Rotational moulded polyethylene water storage tanks of 1000 liters capacity, (cylindrical vertical with closed top) with lid, hoisted and fixed in position all as specified in SSR Part-I including ball valves high pressure of PTMT with epoxy coated aluminium rod and highdensity plastic ball screwed for iron pipe and fixed for 20mm bore pipe, fixing in repairs, complete all as specified and as directed. |
| 10 | Bib taps, cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore pipe, fixing in repairs, complete all as specified and as directed. |
| 11 | Dismantaling of PCC block walling/ brickwork or stone/ boulder masonry, including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles built in cement mortar or cement lime mortar of any description, complete all as specified and as directed. |
| 12 | Hacking out old broken glass (any thickness, size, quality or description) from wooden/ steel frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads, complete all as specified and as directed. |
| 13 | Sheet glass, 3.0mm thick, ordinary quality and glazing with oil putty or with wooden beadings, fixing in square not exceeding 0.50Sqm in each pane, complete all as specified and as directed. |
| 14 | Pre-cast cement concrete block masonry M-10(1:3:6), type C-1 (using 20mm graded crushed stone aggregate) with solid blocks, exceeding 10cm in width and incluing setting in cement mortar 1:6, complete all as specified and as directed. |
| 15 | Rendering 15mm thick on fair faces of on brick work or concrete surfaces, in cement mortar 1:4, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed. |
| 16 | Preparation of new plastered surfaces of walls and applying two coats of cement paint over one coat of priming plastered and other surfaces with alkali resistant priming paintlime wash, complete all as specified and as directed. |
| 17 | Demolition ofstone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar, complete all as specified and as directed. |
| 18 | Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level), ncluding cleaning,removal and disposal of rubbish/ waste materials from premises, complete all as specified and as directed. |
| 19 | Machine pressed precast concrete interlocking paver block 60mm thick, M-35 Grade any shape and size casted in plastic moulds and compacted on vibratory table confirming to IS: 15658-2006 with grey cement and pigment, laid over 25mm thick sand cushioning, complete all as specified and directed. |
| 20 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc, complete all as specified and as directed. |
| 21 | Rendering 15mm thick on fair faces of on brick work or concrete surfaces, in cement mortar 1:6, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed. |
| 22 | Preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over one coat of chalk whiting, preparatory to distempering, complete all as specified and as directed. |
| 23 | Preparation of old/ decorated plastered or unplastered surfaces of walls including washing, rubbing down and stopping of distempered and painted surfaces and applying one coat of distemper oil emulsion, complete all as specified and as directed. |
| 24 | Preparation of old/ decorated plastered or unplastered surfaces of walls and applying one coat of white washing, complete all as specified and as directed. |
| 25 | Preparation of old/ decorated plastered or unplastered surfaces of ceiling and applying one coat of white washing, complete all as specified and as directed. |
| 26 | Plain cement concrete M-15(1:2:4), type B-2 (using 40mm graded crushed stone aggregate), as mass concrete in foundation, complete all as specified and as directed. |
| 27 | Plain cement concrete M-7.50(1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as mass concrete in foundation, complete all as specified and as directed. |
| 28 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and as directed. |
| 29 | Galvanised, corrugated mild steel sheeting 0.63mm thick, with two corrugations side lap, fixed with L-type or J-type or cranked hook bolts in lieu of screws, in roofs, walls etc. with grade of zinc coating 275, complete all as specified and as directed. |
| 30 | Plain, galvanised, mild steel sheeting, 0.80mm thick, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275, complete all as specified and as directed. |
| 31 | Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 32 | Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 33 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and as directed. |
| 34 | Rolled mild Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS: 1161-1979 grade St.-240, complete all as specified and as directed. |
| 35 | Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed. |
| 36 | Preparation of old painted steel surfaces of any description, not otherwise described, over 10cm width or girth including and applying one coat of synthetic enamel paint, complete all as specified and as directed. |
| 37 | Preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10cm width or girth including and applying two coats of synthetic enamel paint over one coat of zinc chrome/ red oxide primer, complete all as specified and as directed. |
| 38 | Chequered cement concrete coloured tiles, pre-polished, size 300mmx300mmx25mm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over 20mm thick screed bed or bedding layer in cement mortar 1:6, complete all as specified and as directed. |
| 39 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed. |
| 40 | Non-skid, coloured, ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.11 Per Square Metre but not exceeding 0.18 Per Square Metre, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including laid over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6, complete all as specified and as directed. |
| 41 | SCHEDULE \"A\" PART-II : BOQ OF WORKS FOR E/M WORKS. |
| 42 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc, complete all as specified and as directed. |
| 43 | Point wiring in PVC (in existing casing and caping to surfaces)or in new casing and caping for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 Volts, using colour coding, drawn in existing or new casing/ caping, of any size including all accessories concealed/ exposed, in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti-corrosive paint and with Bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed.Note: Concealed conduits will be provided where ever required and cost of cutting, chasing and making good to surfaces shall be included in quoted rate |
| 44 | Description all as per serial item No- 2.02 here-in-before but for one 3-pin socket outlet 5/6 -Amps on the independent board. |
| 45 | Description all as serial item No- 2.02 here-in-before but for one 3- pin, 5/ 6-Amps, socket outlet on same board. |
| 46 | Point wiring (in existing casing and caping to surfaces)or in new casing and caping for 3-pin, 15/ 16 Amps, switch socket combination on independent board with 4.0 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in and including any type of casing/ caping of any size including all accessories concealed by chasing/ cutting or fixed with PVC plug and mild steel screws on the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 4.0 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed. |
| 47 | Point wiring in PVC conduits for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 Volts, using colour coding, drawn in existing or new conduit of any size including all accessories concealed/ exposed, in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti-corrosive paint and with Bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed.Note: Concealed conduits will be provided where ever required and cost of cutting, chasing and making good to surfaces shall be included in quoted rate. |
| 48 | Description all as per serial item No- 2.06 here-in-before but for one 3-pin socket outlet 5/6 -Amps on the independent board. |
| 49 | Description all as serial item No- 2.06 here-in-before but for one 3- pin, 5/ 6-Amps, socket outlet on same board. |
| 50 | Point wiring in PVC conduits for one light/ fan/ bell point controlled by one switch with 4.0 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 Volts, using colour coding, drawn in existing or new conduit, of any size including all accessories concealed/ exposed, in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti-corrosive paint and with Bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 4.0 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed.Note: Concealed conduits will be provided where ever required and cost of cutting, chasing and making good to surfaces shall be included in quoted rate. |
| 51 | Switch piano, flush type, single pole, one way, 5/ 6 Amps, complete all as specified and as directed. |
| 52 | Switch piano, flush type, single pole, one way, 15/ 16 Amps, complete all as specified and as directed. |
| 53 | Socket outlet, 2-in-1, 3-pin, 5/ 6-Amps, flush type, complete all as specified and as directed. |
| 54 | Socket outlet, 2-in-1, 3-pin, 5/ 6 and 15/ 16 Amps, combined, flush type, complete all as specified and as directed. |
| 55 | Ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body, size 65mmx25mm dia, complete all as specified and as directed. |
| 56 | Lamp holder, PVC Polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed. |
| 57 | LED lamp, capacity 10 Watt, B-22 holder base with ploycarbonate body and aluminium heat sink, warm/ white light, fixing in repairs, complete all as specified and as directed.Make: Havells ordering code-LHLDDEBNL5R10 and cat part No-LED PLUS 10 W B22 CDL 1S LAMP V7 or equivalent in Philips/ Bajaj/ Crompton. |
| 58 | LED light fitting mirror type with high out put diffuser, 20 watt 220 Volt, AC, decorative type with driver holder including and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed.Make: Havells ordering code- LHEBFOPNIA7W020 or equivalent in Philips/ Bajaj/ Crompton. |
| 59 | LED lights fitting wall surface mounted, 18 Watt, 220 Volt, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed.Make: Havells cat part No-LUMILINEPLUSNEOBS18WLED830SPCSSIND or equivalent in Philips/ Bajaj/ Crompton. |
| 60 | LED street light fitting 30 Watt 230 Volt, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, connecting up with three core flexible copper conductor cable of suitable size, and including house service bracket for mounting light fittings House service bracket any type complete with 1.50mtr long galvanised iron pipe 40mm dia medium grade, bent to required shape including mild steel clamps of flat iron 40x6mm, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed.Make: Havells cat part No- Superb Street Light 30 W 6500 K IP65 or equivalent in Phillips/ Bajaj/ Crompton. |
| 61 | Earthing complete with galvanised iron earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with galvanised iron wire, size 4.0mm dia as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 20mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test pointetc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed by Engineer-In-Charge.Note: Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces. |
| 62 | Sheet metal enclosures for Single Pole and Neutral distribution boxes with single door for incorporating MCBs, IP-65, 2-way with 200 amps rated busbar, 240 volts, as per IS-8623, fixing in repairs, complete all as specified and as directed. |
| 63 | Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-65, 4-way with 200 amps rated busbar, 240 volts, as per IS-8623, fixing in repairs, complete all as specified and as directed. |
| 64 | MCB, single pole, 6 to 32 Amps, 240 Volts, 50 Hz, \"C\" curve including necessary incoming and out going electric connection with suitable size of copper lugs, fixing in repairs, complete all as specified and as directed. |
| 65 | MCB, single pole and neutral, 32 Amps, 240 Volts, 50 Hz, \"C\" curve including necessary incoming and out going electric connection with suitable size of copper lugs, fixing in repairs, complete all as specified and as directed. |
| 66 | MCB, single pole and neutral, 40 Amps, 240 Volts, 50 Hz, \"C\" curve including necessary incoming and out going electric connection with suitable size of copper lugs, fixing in repairs, complete all as specified and as directed. |
| 67 | Switch socket combination of 6 Amps including gang box of PVC Box with 4-fixing Hole, complete all as specified and as directed.Make: Anchor/ Havells/ Legrand. |
| 68 | MCB, single pole and neutral, 63 Amps, 240 Volts, 50 Hz, \"C\" curve including necessary incoming and out going electric connection with suitable size of copper lugs, fixing in repairs, complete all as specified and as directed. |
| 69 | Replacement of old unserviceable sub main wiring with new sub main wiring in PVC casing/ caping of required size as per site for circuits/ submain wiring along with earth wire with two run of 1.50 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 1.50 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, using colour coding, drawn in and including any type of conduit/ new casing and caping, any size including all accessories concealed by chasing/ cutting or fixed with PVC plug and mild steel screws on the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed.Note: Cost of all three run of wire and one run of casing/ caping of required size will be included in quoted rate. |
| 70 | Description as serial item No- 2.28 here-in-before but sub main wiring with two run of 2.50 Sqmm, FRLS PVC insulated multi-stranded copper wire, single core, ISI marked suitable for 1100 Volts and one run of 2.50 Sqmm, FRLS PVC insulated multi-stranded copper wire, single core, ISI marked suitable for 1100 Volts as earth wire. |
| 71 | Description as serial item No- 2.28 here-in-before but sub main wiring with two run of 4.00 Sqmm, FRLS PVC insulated multi-stranded copper wire, single core, ISI marked suitable for 1100 Volts and one run of 4.00 Sqmm, FRLS PVC insulated multi-stranded copper wire, single core, ISI marked suitable for 1100 Volts as earth wire. |
| 72 | Description as serial item No- 2.28 here-in-before but sub main wiring with two run of 6.00 Sqmm, FRLS PVC insulated multi-stranded copper wire, single core, ISI marked suitable for 1100 Volts and one run of 6.00 Sqmm, FRLS PVC insulated multi-stranded copper wire, single core, ISI marked suitable for 1100 Volts as earth wire. |
| 73 | Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor of 6.0 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1.0metre apart including 4.0mm suspension wire, one twin core cable flat or circular, complete all as specified and directed. |
| 74 | Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor of 10.0 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1.0metre apart including 4.0mm suspension wire, one twin core cable flat or circular, complete all as specified and directed. |
| 75 | Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor of 16.0 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1.0metre apart including 4.0mm suspension wire, one twin core cable flat or circular, complete all as specified and directed. |
| 76 | Switch socket combination of 6Amp/16Amp including gang box of PVC Box with 4-fixing Hole, complete all as specified and as directed.Make: Anchor/ Havells/ Legrand. |
| 77 | Amount of Schedule of credit as mentioned here-in-after shall be deducted from quoted amount. |