| 1 | Taking down carefully old/unsv copper/alluminium any type of point wiring for one light, socket, fan, bell or power etc incl all fittings such as switches sockets, holders, light fittings, fan requlators, call bell etc and making good the disturbed surface of wall ceiling complete all as specified and directed. |
| 2 | M&L for concealed type Point wiring with 1.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core multi stranded copper FRLS cable working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in including PVC conduit of adequate size having a wall thickness not less than 1.5 mm with allaccessories (including cutting chases & making good the disturbed surface to its original specification)including 1.5 sq mm (nominal cross sectional area) PVC insulated unsheathed single core multistranded copper conductor FRLS cable as earth continuity conductor connected to main switches/DB\"s or common earth dolly complete all as specified and directed for the following :- |
| 3 | One light point controlled by one way switch 5/6 amps. |
| 4 | One ceiling fan/Exhaust fan point controlled by one way switch 5/6 amps. |
| 5 | One socket out let 5/6 amps point on the independent board |
| 6 | All as per BOQ srl item No 2 above but wiring with 2.5 sq mm single coremultistranded copper conductor for one socket out let 15/16 amps point on the independent board complete all as specified and directed |
| 7 | S&F switch piano flush type 5/6 amps single pole one way complete all as specified and directed. |
| 8 | S&F Switch socket combination2 and 3 Pin, 5/6 amps, multipurpose flush non shutter, non inter locking type white ivory finish complete all as specified and directed. |
| 9 | S&F switch socket combination 2 in 1, 6 pin 5/6 amps and 15/16 amps multipurpose, white/ivory finish flush non shutter non inter locking type complete all as specified and directed. |
| 10 | S&F ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and directed. |
| 11 | S & F deluxe fan Electronic regulator 120/280 volts AC 50 Hzs rotary stepwhite/ivory finish complete all as specified and directed. |
| 12 | S&F LED lightfittings 1 x 18/20watts230 Volt6500K, IP-20, white poly carbonate body, in built surge protection 4KV, zero mercury content, complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable up to cealing rose complete all as specified and directed. |
| 13 | Disconnecting and removing U/S street light fitting of any type from bldg and Supply andfixingLED street light luminaire with high power LED and unique peanut lens to ensure uniform light distribution ,higher spacing between poles and maintence free system of not less than 35 Watts IP 66 type incl standard fittings pressure die cast aluminium housing, heat reistant toughened glass, epoxy powder coated finsh complete with Electronic driver, Surge protector not less than 5 KV and all accessories duly prewired complete all as specified and directed. |
| 14 | Taking down unsv switches/regulators/ceiling rose/lamp holder complete all as specified and as directed. |
| 15 | Taking down unsv FTL/sketch fitting of any type and capacity complete all as specified and as directed. |
| 16 | M&L for sub main wiring with 2 run of 4.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core FRLS cable of working voltage 1100 volts gradewith stranded copper conductor includingone run of 4.00 Sqmm (nominal cross sectional area) PVC insulated unsheathed cable with stranded copper conductor as continuous earth wire connected to common earth dolly drawn in PVC rigid non- metallic conduit with and including taking down unsv sub main, complete all as specified and as directed.NOTE :(i) Two run of 4 sqmm cable alongwith one run of earth wire with one length of PVC conduit of appropriate size shall be measured as one length.. |
| 17 | Taking down old MCB DBs with MCBs/Main switches/wooden boards etc complete all specified and directed. |
| 18 | S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB\"S/lsolators complete all as specified and directed. |
| 19 | S&F Sheet metal enclosure for 4/6 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB\"S/lsolators complete all as specified and directed. |
| 20 | S&F in repair MCB, triple pole 40 to 63 amps, 415 volts, ‘C’ curve, 10 KA all complete as specified and asdirected. |
| 21 | S&F in repair MCB, Single pole & neutral,5 to 32 amps, 240 volts, ‘C’ curve, 10KA allcomplete as specified and as directed. |
| 22 | S&F in repair MCB, Single pole, 5 to32 amps, 240 volts, ‘C’ curve, 10 KAall complete as specified and as directed. |
| 23 | S&F in repair Stop valves15mm diacast copper alloy, screwed down,high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer in Charge. |
| 24 | S&F in repair Stop valves25mm diacast copper alloy, screwed down,high pressure,with crutch or butterfly handle, screwed bothends for iron pipe or for unions and fixed complete all as specified and directed by Engineer in Charge. |
| 25 | S&F in repair Bib taps,15mm dia cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed by Engineer in Charge. |
| 26 | S&F in replacement of existing tank of any cap with doublelayer ISI marked rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position of Capacity 5000 liters complete all as specified and as directed. |
| 27 | S&F in replacement of existing tank of any cap with doublelayer ISI marked rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position of Capacity 2000 liters complete all as specified and as directed. |
| 28 | S&F in replacement of existing tank of any cap with doublelayer ISI marked rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position of Capacity 1000 liters complete all as specified and as directed. |
| 29 | S&F in replacement of existing tank of any cap with doublelayer ISI marked rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position of Capacity 500 liters complete all as specified and as directed. |
| 30 | S&F in replacement ofElectrical insulating rubber mat of size ( 2 mtr X 1 mtr X 2 mm ) tested for LT voltage 1100 volts complete all as specified and directed by Engr-in-charge. |
| 31 | S&F in replacement of MCCB, adjustablethermal and adjustable magnetic setting of capacity 250Amp, 415Volt, four pole, 36 KAcomplete all as specified & directed |
| 32 | S&F in replacement of MCCB, adjustablethermal and adjustable magnetic setting of capacity 200 Amps, 415Volt, four pole, 36 KA complete all as specified & directed |
| 33 | S&F in replacement of MCCB, adjustablethermal and adjustable magnetic setting of capacity 160 Amps, 415Volt, four pole, 36 KA complete all as specified & directed |
| 34 | S&F in replacement of MCCB, adjustablethermal and adjustable magnetic setting of capacity 125 Amps, 415Volt, four pole, 16 KA complete all as specified & directed |
| 35 | S&F in replacement of MCCB, adjustablethermal and adjustable magnetic setting of capacity 100 Amps, 415Volt, four pole, 16 KA complete all as specified & directed |
| 36 | Supply, connecting & passing through pipe/duct, 660 volts grade, PVC insulated, flexible wire with multistranded copper conductor of cross sectional area 16 sqmm 3 core complete with & including all fixing & connecting accessories such as Copper lugs, nut, bolts, washer etc complete with and including taking down unsv wire all as specified and as directed. |
| 37 | M&L for Earthing complete with galvanised steel earth plate electrode 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below the ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth strip 32x6mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or of steel all as shown in electrical plate No 3 of SSR part-I2009 connected to LT Panel/Transformer all as specified and testing on completion including. Necessary excavation, earthwork, PCC works and CI earth pit cover with watering pipe 20mm dia GI pipe medium grade, funnel with wire mesh and lugs and GI pipe 40 mm dia of light grade,for protection of earth stripcomplete all as specified and directed. Note: Excavation/PCC/Earth work/Charcoal/ Salt shall be deemed to be include in this unit rate.Note :- If desired earth resistance is not found then entire earthing shall be re-done by contractor without accruing any extra cost to the Govt. |
| 38 | S & F in replacement of Gun Metal gate valve ISI marked including cutting / threading and welding of existing GI pipe of size 50 mm dia complete all as specified and directed. |
| 39 | S & F in replacement of Gun Metal gate valve ISI marked including cutting / threading and welding of existing GI pipe of size 40 mm dia complete all as specified and directed. |
| 40 | S & F in replacement of Gun Metal gate valve ISI marked including cutting / threading and welding of existing GI pipe of size 25 mm dia complete all as specified and directed. |
| 41 | S & F in replacement of Gun Metal gate valve ISI marked including cutting / threading and welding of existing GI pipe of size 20 mm dia complete all as specified and directed. |
| 42 | Supply and laying in repair PVC insulated cable submersible flat copper 3 core 16Sqmm1100 volt grade, complete all as specified and directed. |
| 43 | S&F in repairs Motor Protection Circuit Breaker (MPCB), 3 pole, 415 volts, 25/34 KW, 50 KA breaking capacity with instantaneous trip-rotary type complete all as specified and directed |
| 44 | S&F in repair Post top latern of capacity 25watt LED type, IP65, spun aluminium luminaire complete with and all connected accessories (Electronic Driver/connector block/prewired) all as specified and directed. |
| 45 | Demolition of PCC of any type not exceeding 150mm and disposal of the same at a distance not exceeding 50mtr complete all as specified and directed by Engr in charge. |
| 46 | M & L for cement concrete (1:4:8) type C-2 (using 40mm graded mechanically crushed stone aggregate) 75mm thick as in sub base for floor, hard standing/paving etc complete all as specified and directed. |
| 47 | M & L for cement concrete (1:2:4) type C-2 (using 20mm graded mechanically crushed stone aggregate) 75mm thick as in paving/hardstandings/layingpanels including joints etc for floor finishing complete all as specified and directed. |
| 48 | supply, installation, testing and commissinoning LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC, 50Hz indoortype, floor mounted, free standing, dust and vermin proof, air ventilation factory fabricated made out of 2 mm thick CRCA sheet duly powder coated and shall be CPRI approved .The Panel shall have front and rear opening, locking arrangement, cable alleys, bus bar chamber and switch gear compartment, hinged door with rubber gasket, cable gland, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, aluminium bus bar duly covered with heat shrink sleeves colour coded duly fixed on DMC/SMC insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length, incoming and outgoing MCCBs shall have extended bus bar links and mounted on MS angle iron frame of suitable size duly painted including PCC 1:2:4 Type B1 (using 20 mm graded mechanically crushed stone aggregate) in foundation as the site requirement complete all as specified and directed by Engr-in-charged including comprising of following :-(a) MCCB 415 V 4 Pole 200 Amps 35/36 kA with adjustible thermal and adjustible magnetic setting- 01Nos(incommer) (b) MCCB 415 V 4 Pole 160 Amps 25kA with adjustible thermal and adjustible magnetic setting- 01Nos (Outgoing)(c) MCCB 415 V 4 Pole 63 Amps 16 kA with adjustible thermal and adjustible magnetic setting- 01Nos (Outgoing)(d) MCB 63 Amps, FP,10 KA, 415 volts, 50Hz-1 Nos (Outgoing)(e) Fully Automatic Star Delta Starter MU-G50 FASD, capacity 50HP (With Wideband Coil). Make& L&T Cat Pt No CS96009COJO- 01Nos (f) On-load change over switch 200 Amps, 4Pole, 415 V, 50Hz front handle operated type -01 No. Make :- L&T/ABB/Havells(g) Digital Ammeter, with CTs & ASS-01 set(h) Digital voltmeter, with VSS-01 set(j) LED phase indication lamps RYB-01 set(k) CTs 3 Nos of current ratio 100/5A - Set of 3 (l) Aluminium bus bar TPN 300 Amps rating |
| 49 | supply, installation, testing and commissinoning LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC, 50Hz indoortype, floor mounted, free standing, dust and vermin proof, air ventilation factory fabricated made out of 2 mm thick CRCA sheet duly powder coated and shall be CPRI approved and as approved by GE. The Panel shall have front and rear opening, locking arrangement, cable alleys, bus bar chamber and switch gear compartment, hinged door with rubber gasket, cable gland, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, aluminium bus bar duly covered with heat shrink sleeves colour coaded duly fixed on DMC/SMC insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length, incoming and outgoing MCCBs shall have extended bus bar links and mounted on MS angle iron frame of suitable size duly painted including PCC 1:2:4 Type B1 (using 20 mm graded mechanically crushed stone aggregate) in foundation as the site requirement complete all as specified and directed by Engr-in-charged including comprising of following :-(a) MCCB 415 V 4 Pole 200 Amps 35/36 kA with adjustible thermal and adjustible magnetic setting- 01Nos(incommer) (b) MCCB 415 V 4 Pole 100 Amps 16 kA with adjustible thermal and adjustible magnetic setting- 03Nos (Outgoing)(c) MCCB 415 V 4 Pole 63 Amps 16 kA with adjustible thermal and adjustible magnetic setting- 01Nos (Outgoing)(d) Fully Automatic Star Delta Starter MU-G30 FASD,Capacity 30HP (With Wideband Coil). Make& L&T Cat Pt No CS96009COJO- 03Nos (f) On-load change over switch 200 Amps, 4Pole, 415 V, 50Hz front handle operated type -01 No Make :- L&T/ABB/Havells(g) Digital Ammeter, with CTs & ASS-01 set(h) Digital voltmeter, with VSS-01 set(j) LED phase indication lamps RYB-01 set(k) CTs 3 Nos of current ratio 100/5A - Set of 3 (l) Aluminium bus bar TPN 300 Amps rating |
| 50 | M&L for Cleaning the vegetation including grass, bushes, small trees and all vegetation growth complete including digging out the root of bushes,small trees around the installations/sump/OH reservoir, valve chamber, including chamber etc fillingthe rough holes with earth, levelling the surfaces by removing all debristo a distance not exceeding 50m complete all as specified and directed. |
| 51 | S&F in replacement of powder coated metal First aid Kit box, cabinate type, water proof, wall mountable type, multi compartment of minimum size 38(W)X32(H)X15(D) cm, suitable for 10 persons complete with all first aid medical kit accessories as per factory act 1948 complete all as specified and as directed by Engineer-In-Charge. |
| 52 | Supply, testing and commissioning of rechargeable LED Torch 230Volts, body material: plastic,Battery type: Min.4000mAh, Li-ion, wattage: 5watt complete with all connected accessories all as specified and as directed by Engineer-In-Charge. Make: Havells of Model No: LHEXTGP1CN1G005 or of equivalent in Wipro/Everday. |
| 53 | Supply, testing and commissioning of Portable, compact and multipurpose step Aluminium foldable Telescopic ladder 18feet, 14steps, can support upto 150kg complete all as specified and as directed by Engineer-In-Charge. |
| 54 | Supply, fixing, testing and commissioning in replacement of Electronic Over current relay of current range 5.0 - 80Amps, built in display, bottom hole, G/F protection for protection of Submersible pump 35-40HP, against protection from over&under current, phase loss, phase unbalance, phase Reversal, locked rotor and ground fault, complete with and including connection with suitable size stranded copper conductor cable all as specified and directed. Make: BCH of Model No: BOCR 3EZ 80 or of equivalent in L&T/Legrand/schineider as approved by GE.Note: Any accessories/spares required for effective functioning of Over Current relay shall be deemed to be included in the unit rate. |