| 1 | Demolition of cement concrete in ground floors and pavings n.exc 15cm thickness (below or above ground level). |
| 2 | M&L 75mm thick Cement concrete type B- 2, 1:2:4 (40mm graded aggregate)complete as in level course with finishing in cement concrete surface even and roughto receive screed bed complete |
| 3 | M&L 75mm thick PCC 1:3:6 type C2 using 40 mm graded crushed stone aggregate as in plinth protection incl finishing even and smooth w/o using extra cement. |
| 4 | M&L for providing PCC 1:2:4 type B-0 as in roof kerbs or mud stops rouded or chamfered on edges (using 12.5mm graded stone aggregate) complete all as specifed and directed. |
| 5 | M&L for Mirror polished Kota Stone slab flooring 20-25 mm thick over cement screed bed 15mm thick 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-Charge. |
| 6 | M&L for mirror polished Kota Stone slab 20-25 mm thick in riser of steps, skirting, dado and, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishingover screed bed of 15 mm thick 1:6 and pointed in white or coloured cement to match complete all as specified. |
| 7 | Demolition of brick work built in cement mortar all as specified |
| 8 | M&L for brick work with sub class `B’ bricks, straight on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed. |
| 9 | M&L for 15mm thick cement plaster in CM (1:4) on fair faces of brick or concrete surfaces using WPC where ever requiredas per manufacturerer\"s instructions and finishing the surface even and smooth (without using extra cement) etc. incl finishing even and faircomplete all as specified NOTE -WPC shall be measured and paid separetely. |
| 10 | Supply only WPC complete all as specified and directed. |
| 11 | M&L for rendering 15mm thick on fair faces of brick work in CM 1:6 finished even and fair without using extra cement complete all as specified and directed. |
| 12 | M&L for preparation of newly plastered surfaces of wall applying a layer of wall care putty 2mm thick (averaging) , finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed. |
| 13 | Preparing new plastered or unplastered surfaces of walls and applying 2mm thick wall care, putty and two coats of distemper oil emulsion, white or tinted over a coat of primer, complete all as specified and directed. |
| 14 | Dismantling plain or corrugated steel sheeting, any gauge, thickness as in roof etc., coverings complete all as specified and directed. |
| 15 | DismantlingAsbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed. |
| 16 | S&F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet0.50mmthick of any colour having tensile strength of 550 MPAas in roof covering /cladding to wall, fixed with self tapping screws as specified complete all as specified |
| 17 | S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as inroof covering/cladding to wall, fixed with self tapping screws as specified. |
| 18 | Dismantling wrought iron or mild steel work of any description not otherwiseprovided for |
| 19 | S&F framed work such as grills,gratings, etc with ends of bars shouldered and / or riveted or forged into spikes; framed guard ; barred iron doors; ladders ; framed balusters; walk ways; railing and simillar work Con-forming to Fe 290 Gde E-165. |
| 20 | Dismantling framed work timber scantlings 40 sq. cm and over in section, in any position |
| 21 | S&F rolled mild steel sections channel angle Tee section and in tubular sectionas in main and cross beams, hip and jack rafters; purlins,post where connected to common rafters and running rails fixed with angle cleat or other connecting plates conforming to Fe 410-W Gde-E-250, quality A complete all as specified and directed. |
| 22 | M&L for two coats of synthetic enamel painting over a coat of red oxide zinc chrome primer on steel surfaces over 10cm width or girth including preparation of surface complete. |
| 23 | Taking down chowkats or frames exc 1.50 sqm but n.exc 4.00sqm incl iron mongry each. |
| 24 | S&F Factory made single extruded WPC (wood polymer Composite) solid door/ window/ Ceosetory window & other Frames/ Chowkhat of size 45 x 70 mm comprising ofPVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wwod powder/ rick husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms ) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded stat headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N / mm 2 and resistance to spread of flame of Class A catogory with property of being termite/ borer proof, water / moisture proof and fire retardant and fixed in position with MS hold fast/lugs / SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. |
| 25 | S&F Factory made single extruded WPC (wood polymer Composite) solid plain flush door shutter of 35 mm thickcomprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/ cum and screw withdrwal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N mm2 modulus of elasticity 850 N / mm2 and resistance to spread of flame of Class A catogary with property of being termite/ borer proof, water/ moisture proof and fire retardanat and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, all as per direction of Engineer-In-Charge (Note:- stainless steel butt hingesshall be paid separately complete all as specified and directed. |
| 26 | S & F aluminium handle, cast type anodized 150mm size. |
| 27 | S & F 150 mm long aluminium anodized barrel tower bolts of extruded section lcomplete all as specified and as directed. |
| 28 | Supply & fixing butt hinges medium weight cold rolled mild steel of 100mm long complete all as specified and directed. |
| 29 | Taking down chowkats or frames n.exc 1.50 sqm each with shutters (without taking off shutters from the frames) complete. |
| 30 | S&Fpowder coated Anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete shall as specified. |
| 31 | S&F 3MM Sheet glass, selected quality and glazing with oil putty in squares n exc 0.5 sq. m in each pane. |
| 32 | S&F in repair Stainles steel wire cloth, 0.45 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with alluminium staple and around all beading complete all as specified and as directed |
| 33 | M&L 100 mm thick PCC (1:4:8 ) type D-2 as in sub base finished even and roughcomplete all as specified and as directed. |
| 34 | M&L Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete.; complete all as specified and as directed. |
| 35 | Taking down carefullyaluminium/copper wiring of any size (for light, fan, socket or power etc complete) including fixture and fittings such as switches, sockets, ceiling roses, pendent holders regulators, tube lights etc and making good disturbed surfaces of wall, roof etc to match with existing surface. |
| 36 | Supply & Fixing point wiring for one light point/ fan point controlled by one, one way switch with 1.5Sqmm size, PVC insulated and unsheathed 1100volts grade, single core stranded (multistrand) copper conductor (FRLS)PVC cable drawn into & including medium grade PVC conduit (not less than 20mmouter dia ) with all fittings and accessories fixed concealed(including chase cutting in brick/ stone masonry walls for fixing conduit and plastering and whitewash/colouring the external surface and matching the same with existing surface) andsunk cast iron or pressed steel terminal boxes for mounting fittings like switches, sockets & fan regulators etc with 3 mm thick plastic laminated sheet covers fixed with brass screws and cup washersincluding one continuous run of PVC insulated (green colour) 1.5 Sqmm multistrandedcopper conductor cable earth wire and connected to earth dolly complete all as specified and directed (Note:- wiring shall be done in colour coding as directed by Engineer in charge. |
| 37 | All as per item No. 2 herein before but one socket outlet 5 Amps on the same board. |
| 38 | All as per item No.2 herein before butone 3 pin socket outlet 5 Amps independent. |
| 39 | All as per item No. 2 above but with 2.5 Sq mm two single core and 2.5 Sq mm one single core as earth wire for 5/15 Amps socket. |
| 40 | supply & Fixing lamp holder PVC insulated body with back plate for angle/battern fitting complete all as specified and directed |
| 41 | Suppy & Fixing switch piano flush type single pole, one way 5 Amp complete all as specified and directed. |
| 42 | Supply & Fixing switch piano, flush type single pole 15 Amp complete all as specified and directed. |
| 43 | Supply & Fixing socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type complete all as specified and directed. |
| 44 | Supply & Fixing socket outlet 2 in 1, 3 pin, 5 Amp flush type complete all as specified and directed. |
| 45 | Supply & Fixing ceiling rose, PVC/ Poly carbonate, isolated body three terminal complete all as specified and directed. |
| 46 | Supply & Fixingsheet metal enclosure for DBs(double door type)single pole and neutral 8 way including blanking plate as required with 200 Amps rated bus bar, 240 volts fixed complete all as specified and directed . |
| 47 | Supply & Fixing 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of SPN 40 to 63 Amp and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed . |
| 48 | Supply & Fixing 240V, 10KA \"B\" curve miniature circuit breaker (MCB) of single pole 5 to 32 Amp and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed . |
| 49 | Supply and fixing LED lights fitting 1x 20W (warm/milky white as required on site), 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and life of tube light not less than 50,000 hours.completeall as specified and directed..Make Havells cat pat LUMILINEBS20WLED865SPCWH or equivalent of phillips/wippro/Bajaj/Surya complete Note:- LED tube light shall be purches to get minimum 2 year warrenty of material from manufracturer. |
| 50 | S & F LED light fitting 1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. Make : Havells cat pat HEXAFT10WLED857SSYMBOPC or equivalent cat part in makephillips/wippro/Bajaj & C&S .Note:- Contractor shall submit 2 year warrenty of material from manufracturer alongwith purchase voucher. |
| 51 | M&L for Earthingcomplete with galvanized sheet earthplate electrodes 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2. 25mtr deep below ground level) with top edge of plat not less than 1.5 mtr below normal ground level connected to galvanized iron strip 25 x 4 mm as earthing lead by means of bolts, nuts , check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3and including excavation and earth work, GI pipe light grade 15 mm bore for protection of GI wire from earth electrode to and incl the earth test point of galvanized Iron/steel of size 75x75x 25mm,supplying and laying charcoal dust, common salt, PCC 1:2:4 typeB1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6 mm dia TMT bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh,20 mm dia GI pipe light grade for wateringand connected to earth test point including brazing at all joints except at test point and testing complete all as specified and directed by Engr-in-Charge. |
| 52 | M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade, cross section area 16 Sqmm 4core laid in trenches or passing through pipes/ducts and incl the disturbence surface of road making good with using PCC complete all as specified and directed. Including taking down old LT U/G Cable from trenches/protection pipe etc complete. |
| 53 | Excavation in trenches not exceeding 1.5 mtr wide, depth exceeding 1.5 mtr and getting out in hard/dense soil complete all as specified and directed by Engineer-in-charge |
| 54 | Returning, fillingincl spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil all as specified and directed. |
| 55 | Removing excavated material (soil) not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above thestarting point complete all as specified and directed. |
| 56 | M&L for dry clean sand filling in trenches below and around under ground cable cushioning complete all as specified and directed.. Note :-Thickness of sand cushioning shall be measured after punning. |
| 57 | M&L for brick sub class \"B\" for protection of cable comlete all as specified and directed. |
| 58 | Supply and Fixing steel tube Light grade galvanised 50 mm bore with all fittings for protection of UG cable under road/culvert and fixing on wall with saddle, screw complete all as specified and directed. |