| Sl. No. | Item Description |
| 1 | Admin Block |
| 2 | Scraping Cement plaster |
| 3 | Scraping White wash and colour wash |
| 4 | 12.5 mm thick cement plaster 1:4 |
| 5 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wallputty by applying two or more coats to get required finish |
| 6 | Finishing walls with Premium Acrylic smooth exterior paint with of required shade with two or more coats applied @ 1.67litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 7 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give aneven shade |
| 8 | Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint. |
| 9 | Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. Doors of area 3 sqm and below. |
| 10 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standarddesign latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to thesatisfaction of Engineer-in-charge. Door and window frame of size 113mmx60mmxwith 35mm wide single rebate |
| 11 | Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code S 2202-1 (1999): Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges 35mm thick |
| 12 | Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt)For shutter area above 0.50 sqm |
| 13 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete 300mm x 16mm |
| 14 | Providing & fixing 6\" stainless steel handles ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge. |
| 15 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. |
| 16 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. |
| 17 | Regrading terracing of mud plaster covered with tiles or bricks in cement by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud plaster to proper, slope, relaying mud plaster Gobri leaping and tiles or bricks grouted in cement mortar 1:3 (1 cement and 3 fine sand) including replacing unserviceable tiles, or bricks with new over and disposal of unserviceable material to the dumping ground within 50 m lead (The cost of new tiles or bricks excluded). |
| 18 | Supply of New Tile at site complete in all respects |
| 19 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 20 | CEO Block |
| 21 | Scraping Cement plaster |
| 22 | 10mm thick Cement Plaster 1:4 |
| 23 | 12.5 mm thick cement plaster 1:4 |
| 24 | 20mm thick cement plaster 1:5 in two coat work |
| 25 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wallputty by applying two or more coats to get required finish |
| 26 | Finishing walls with Premium Acrylic smooth exterior paint with of required shade with two or more coats applied @ 1.67litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 27 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give aneven shade |
| 28 | Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint. |
| 29 | Regrading terracing of mud plaster covered with tiles or bricks in cement by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud plaster to proper, slope, relaying mud plaster Gobri leaping and tiles or bricks grouted in cement mortar 1:3 (1 cement and 3 fine sand) including replacing unserviceable tiles, or bricks with new over and disposal of unserviceable material to the dumping ground within 50 m lead (The cost of new tiles or bricks excluded). |
| 30 | Supply of New Tile at site complete in all respects |
| 31 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 32 | Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect. Glazing area above 0.09 sqm (5.0mm thick Plate glass (INDIAN)) |
| 33 | Bathroom/ Toilet Repair |
| 34 | Dismantling glazed tiles (to be carefully removed). |
| 35 | Scraping Cement plaster |
| 36 | 20mm thick cement plaster 1:5 in two coat work |
| 37 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wallputty by applying two or more coats to get required finish |
| 38 | Finishing walls with Premium Acrylic smooth exterior paint required shade with two or more coats applied @ 1.67litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 39 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give aneven shade |
| 40 | 115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement mortar in superstructure |
| 41 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 250 x 330 mm & 300x300mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 42 | Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading. |
| 43 | Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. Doors of area 3 sqm and below. |
| 44 | Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. Windows of area 3 sqm and below |
| 45 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standarddesign latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to thesatisfaction of Engineer-in-charge. Door and window frame of size 113mmx60mmxwith 35mm wide single rebate |
| 46 | Supplying and fixing of GI sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter. |
| 47 | Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code S 2202-1 (1999): Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges 35mm thick |
| 48 | Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt)For shutter area above 0.50 sqm |
| 49 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete 300mm x 16mm |
| 50 | Wire gauge fixed on chowkats with 25mm thick Hollock wood cover molding of full width. |
| 51 | Providing & fixing 6\" stainless steel handles ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge. |
| 52 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. |
| 53 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. |
| 54 | Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint. |
| 55 | Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. Doors of area 3 sqm and below. |
| 56 | Supplying and fixing of GI sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Door and window frame of size 113mmx60mmx with 35mm wide single rebate |
| 57 | Workshop No. 1 |
| 58 | Ddismantling Cement concrete plain1:2:4 mix |
| 59 | Cement concrete 1:2:4 With stone ballast or shingle mixing by mechanical means using concrete mixer volumetric type |
| 60 | Scraping Cement plaster |
| 61 | 12.5 mm thick cement plaster 1:4 |
| 62 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wallputty by applying two or more coats to get required finish |
| 63 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give aneven shade |
| 64 | Scraping Cement plaster |
| 65 | 20mm thick cement plaster 1:5 in two coat work |
| 66 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wallputty by applying two or more coats to get required finish |
| 67 | Scraping White wash and colour wash |
| 68 | Finishing walls with Premium Acrylic smooth exterior paint required shade with two or more coats applied @ 1.67litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 69 | Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint. |
| 70 | Providing & Fixing of 10 gauge welded mesh of 25mm x 25mm size fixed on steel glazing with MS flat 20mm x 6mm beeding complete in all respect including painting two coats with Synthetic Enamel Paint and Priming Coat |
| 71 | Corrugated asbestos Sheet roofing 6 mm thick sheets fixed with G.I. hooks and bolts, limpet and bitumen washers complete fixed in position excluding the cost of perlins, rafters and trusses. |
| 72 | Scraping Cement plaster |
| 73 | Damp proof course 4cm thick of cement concrete 1:2:4 with 2 coats of bitumen 20/30 penetration at 1.65 Kg per sqm laid hot and sanded |
| 74 | First class burnt brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level. |
| 75 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 76 | 20mm thick cement plaster 1:5 in two coat work |
| 77 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 78 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 79 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 80 | Providing and Fixing of Copper Sheet 16 Gauge 350mm wide on expansion joint including covering with C. Concrete complete in all respect as per specifications. |
| 81 | Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect. Glazing area above 0.09 sqm (5.0mm thick Plate glass (INDIAN)) |
| 82 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item) Float glass panes of 5 mm thickness |
| 83 | Supplying and fixing rolling shutters, of approved make, made of 80mmx1.25mm, M.S. Laths, interlocked together through their entire length and jointed together, at the end, by end locks, mounted on specially designed pipe shaft, with brackets, side guides, 27.5cm long wire spring grade No. 2 and arrangement for inside and outside locking with push and pull operation complete, including top cover 0.80mm thick (payment is to be made for the exact size of opening where rolling shutter is to be fixed) |
| 84 | Providing and fixing ball bearing for push and pull type rolling shutters, from 9.20 to 12 sqm area |
| 85 | Bathroom/ Toilet Repair |
| 86 | Dismantling glazed tiles (to be carefully removed). |
| 87 | Scraping Cement plaster |
| 88 | 20mm thick cement plaster 1:5 in two coat work |
| 89 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wallputty by applying two or more coats to get required finish |
| 90 | Finishing walls with Premium Acrylic smooth exterior paint with required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 91 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give aneven shade |
| 92 | 115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement mortar in superstructure |
| 93 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 250 x 330 mm & 300x300mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 94 | Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading. |
| 95 | Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. Doors of area 3 sqm and below. |
| 96 | Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. Windows of area 3 sqm and below |
| 97 | Supplying and fixing of GI sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Door and window frame of size 113mmx60mmx with 35mm wide single rebate |
| 98 | Supplying and fixing of GI sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter. |
| 99 | Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code S 2202-1 (1999): Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges 35mm thick |
| 100 | Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt)For shutter area above 0.50 sqm |
| 101 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete 300mm x 16mm |
| 102 | Wire gauge fixed on chowkats with 25mm thick Hollock wood cover molding of full width. |
| 103 | Providing & fixing 6\" stainless steel handles ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge. |
| 104 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. |
| 105 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. |
| 106 | Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint. |
| 107 | Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. Doors of area 3 sqm and below. |
| 108 | Supplying and fixing of GI sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Door and window frame of size 113mmx60mmx with 35mm wide single rebate |
| 109 | Workshop No. 2 |
| 110 | Ddismantling Cement concrete plain1:2:4 mix |
| 111 | Cement concrete 1:2:4 With stone ballast or shingle mixing by mechanical means using concrete mixer volumetric type |
| 112 | Scraping Cement plaster |
| 113 | 12.5 mm thick cement plaster 1:4 |
| 114 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wallputty by applying two or more coats to get required finish |
| 115 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) one coat over one priming coat on olddistempered surface |
| 116 | Scraping Cement plaster |
| 117 | 20mm thick cement plaster 1:5 in two coat work |
| 118 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wallputty by applying two or more coats to get required finish |
| 119 | Scraping White wash and colour wash |
| 120 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 121 | Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint. |
| 122 | Providing & Fixing of 10 gauge welded mesh of 25mm x 25mm size fixed on steel glazing with MS flat 20mm x 6mm beeding complete in all respect including painting two coats with Synthetic Enamel Paint and Priming Coat |
| 123 | Corrugated asbestos Sheet roofing 6 mm thick sheets fixed with G.I. hooks and bolts, limpet and bitumen washers complete fixed in position excluding the cost of perlins, rafters and trusses. |
| 124 | Scraping Cement plaster |
| 125 | Damp proof course 4cm thick of cement concrete 1:2:4 with 2 coats of bitumen 20/30 penetration at 1.65 Kg per sqm laid hot and sanded |
| 126 | First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth |
| 127 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 128 | 20mm thick cement plaster 1:5 in two coat work |
| 129 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 130 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 131 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 132 | Providing and Fixing of Copper Sheet 16 Gauge 350mm wide on expansion joint including covering with C. Concrete complete in all respect as per specifications. |
| 133 | Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect. Glazing area above 0.09 sqm (5.0mm thick Plate glass (INDIAN)) |
| 134 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item) Float glass panes of 5 mm thickness |
| 135 | Supplying and fixing rolling shutters, of approved make, made of 80mmx1.25mm, M.S. Laths, interlocked together through their entire length and jointed together, at the end, by end locks, mounted on specially designed pipe shaft, with brackets, side guides, 27.5cm long wire spring grade No. 2 and arrangement for inside and outside locking with push and pull operation complete, including top cover 0.80mm thick (payment is to be made for the exact size of opening where rolling shutter is to be fixed) |
| 136 | Providing and fixing ball bearing for push and pull type rolling shutters, from 9.20 to 12 sqm area |
| 137 | Boundary wall |
| 138 | Scraping Cement plaster |
| 139 | Dismantling dry brick work |
| 140 | First class burnt brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level. |
| 141 | 12.5 mm thick cement plaster 1:4 |
| 142 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wallputty by applying two or more coats to get required finish |
| 143 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 144 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. |
| 145 | Cement concrete 1:5:10 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 146 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 147 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth |
| 148 | First class burnt brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level. |
| 149 | 12.5 mm thick cement plaster 1:4 |
| 150 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wallputty by applying two or more coats to get required finish |
| 151 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 152 | Iron grated doors, including pintle hinges & arrangements. |
| 153 | Providing Polyester Powder coating 60 to 70 micron any coloured specified to M.S Grill section of various sizes including carriage of material from market to workshop & workshop to site of work. |
| 154 | Credit of brick bats |
| 155 | Credit of bricks |
| 156 | Parking Shed |
| 157 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. |
| 158 | Cement concrete 1:5:10 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 159 | Cement concrete 1:2:4 With stone ballast or shingle mixing by mechanical means using concrete mixer volumetric type |
| 160 | Steel work in built up tubular pipes (round, square or rectangular hollow tubes etc. ISI Marked) for flat shed (ie.Where no truss work is involved) including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 161 | Providing and fixing ( PPGL) precoated painted galvalume sheet roofing (size, shape and pitch of corrugation as approved by Engineer-in-charge)The end rib shall have anti cappillary groove and return leg. The steel sheet must be having yield strength of 550 MPa ( Fy= 550 MPa) metalliccoated with Zinc- Aluminium alloy ( i.e. 55% Al, 43.4%Zinc, 1.6% Si Zincalume) AZ150 ( Min. 150 bm/mm2 total on both sides), pre painted withsuper Durable Polyster XRW quality paint includes inorganic infrared reflective pigment. The sheet confirms to general requirement of AS/NZS2728 type 4/ IS 15965 class 3 durability and gloss value of 25% -40%. should be supplied in single length upto 12 metre or as desired by Engineer-incharge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.50 mm (+ 0.05 %) thick |
| 162 | Providing and laying of Brick on end edging 6.83cm wide, 11.11cm long and 22.86cm high half brick deep including excavation, refilling and disposal of surplus earth up to 50mtr complete as per Punjab PWD specifications |
| 163 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibrohydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge. IS Code:15658 (2006) |
| 164 | Total of Civil Works |
| 165 | Public Heath Works |
| 166 | SUB HEAD:-1- REPAIR OF SEWERAGE DISPOSAL- |
| 167 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction Including disposal of all surplus soil as directed within lead of 30 metres. |
| 168 | Dismantling concrete or precast concrete |
| 169 | Reinforced Cement Concrete |
| 170 | Centring and shuttering for flat surfaces such assuspended floors, roofs, landings, chajjas,shelves etc.(for dismantling) |
| 171 | Cement Concrete 1:8:16 with stone aggregate 40 mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 172 | Reinforced Cement Concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS: 1791 and vibrated by needle vibrator but excluding steel reinforcement centering and shuttering in foundation and plinth |
| 173 | first class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth |
| 174 | first class burnt brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level |
| 175 | Finishing walls with cement based water soluble exterior paint such as snowecem, robbiacem etc. on old work one coat to give an even shade |
| 176 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 177 | Painting two or more coats with synthetic anamel paints in all shades on old wood work or metallic or plastered or concrete surface togive an even shade including rubbing down old paint. |
| 178 | Cold twisted deformed(ribbed/tor steel) Bars Fe 415 grade as per IS 1786-1985 for RCC works, where not including in the complete rate of RCC including bending, binding, and placing in position complete. |
| 179 | Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make |
| 180 | Glass panes 3mm or 8.44 kg per sqm upto 0.4 sqm area |
| 181 | Earth work in excavation for storage and sedimentation tanks, high level tanks, filter beds, clear water reservoirs, pump houses, sumps, screening chambers and other similar works having straight or open cuttings in foundations trenches etc. with 3D Excavator/ JCB including manually dressing of bed, trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineerin- charge, including dressing of bottom and sides of trenches, stacking the excavated soil clear from the excavation anubsequent filling around plinth/structures includingwatering dressing and disposal of surplus soils as directed upto 15 metre complete in all respects. |
| 182 | Depth upto 1.5 mtr BGL |
| 183 | for all kinds of soil except rocky |
| 184 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge). |
| 185 | Class PN-1.6 as per ISI |
| 186 | 100 mm i/d Sluice valves flanged |
| 187 | Providing and fixing RCC manhole covers only 560mm i/d RCC man hole cover only as per ISI |
| 188 | Extra heavy duty |
| 189 | Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex,Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness andmaking good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. |
| 190 | 110mm o/d pipe |
| 191 | Making soak pit 2.5 m outer Diametre 3.0 metre deep 230 mm thick 1:5 brick work honey comb with bricks of 1st Class and S.W. drain pipe 100 mm Diametre, 1.8 m long complete as per standard design. With F.P.S. bricks |
| 192 | Disilting all types of main sewers 760 mm and onwards internal dia by silt clearing machines addopting all safety measures and disposal of silt upto 5km complete in all respects. |
| 193 | Disilting of manhole including all safety measures, cost of container T & P and disposal of silt upto 5km complete in all respects. |
| 194 | Depth upto 3 m. |
| 195 | Grassing of grounds with doob grass including uprooting rank vegetation and weeds by digging the area to a depth of 15 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, mixing fertilizer, rough dressing and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts, planting grass roots in rows 10 cm apart in both directions, watering, weeding and maintenance till turf is formed. |
| 196 | Planting Rose beds including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, triangular planting of sapling at 60cm distance from plant to plant and row to row. |
| 197 | Providing & fixing MS Sign Board. |
| 198 | Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects |
| 199 | Providing & fixing angle iron pickets with angle 40mm x40mm x 6mm including cost of concrete block & painting complete in all respects |
| 200 | Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects. |
| 201 | Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm. |
| 202 | Construction of masonry gate pillar including cost of MS Steel Gate size 1.22mtr x 1.37 mtr complete in all respect. |
| 203 | SUB HEAD:-2- RENOVATION OF PUBLIC HEALTH SERVICES IN VARIOUS TOILET BLOCKS AND PROVIDING & INSTALLING WATER COOLER ALONG WITH RO- |
| 204 | Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. |
| 205 | Doors of area 3 sqm and below. |
| 206 | Providing and fixing 10mm thick acid and/or alkali resistant tiles 300 mm x 300 mm of approved make and colour using acid and/or alkali resisting mortar bedding and joints filled with acid and/or alkali resisting cement as per IS : 4457 complete as per the direction of Engineer-in- Charge, in flooring or in dado / skirting on a bed of 12 mm thick mortar 1 : 4 (1 acid proof cement: 4 coarse sand). |
| 207 | Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle &Teflon seats, on G.I. Pipe lines including all carriages complete. |
| 208 | 20mm i/d Brass Ball valves |
| 209 | Providing ,laying, jointing, fixing and testing ISI Marked G.I. Pipe (as per IS 1239) BClass including cost of specials (such as tees, bends, sockets, elbows etc.) ,painting with anti corrosive bitumastic paint, testing, cutting, threading Inside building complete. |
| 210 | 15 mm i/d |
| 211 | 20 mm i/d |
| 212 | 25 mm i/d |
| 213 | Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 214 | Extra for providing and fixing C.P. Brass short flush bend 32mm instead of PVC short bend. |
| 215 | Providing and fixing jet spray with 2\"-6\" long PVC pipe. |
| 216 | With C.P. Brass nut |
| 217 | Extra for providing and fixing 10 litres capacity Chinaware low level flushing cistern with PVC internal fitting, instead of 10 litres capacity PVC flushing cistern. |
| 218 | Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete. |
| 219 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. |
| 220 | Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect. |
| 221 | Water Cooler Semi Steel Body 80/120 ltr without Stablizer |
| 222 | Providing & fixing in position UV filter having flow rate 200 ltr/hr with 3 stage purification process having 16 watt UV lamp and 35 Watt power rating of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect. |
| 223 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect. |
| 224 | Size 550 mm x 400 mm x 815 mm (Labour only) |
| 225 | Providing and fixing vitreous chinaware pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect. |
| 226 | Vitreous chinaware standard white pedestal for wash hand basin. |
| 227 | Providing & fixing in position 15 mm i/d C.P brass wall mixer of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 228 | C.P brass wall mixer with Telephonic Shower |
| 229 | Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect. |
| 230 | Rectangular Sink with Deluxe Border Single Bowl Overall Size 700 mm x 555 mm x 230 mm (Labour Only) |
| 231 | Providing and fixing in position towel rails /ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. |
| 232 | C.P. brass towel Rails size 15mm dia 610mm long |
| 233 | Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect.) fixed in with rawl plugs and C.P brassscrews complete in all respect. |
| 234 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) |
| 235 | Size 600mmx450mm |
| 236 | Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge) under various fixtures complete in all respect. |
| 237 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-in-charge)with various fixtures complete in all respect. |
| 238 | C.P. Brass extension piece, 25mm long to 50mm long |
| 239 | Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge) complete in all respect. |
| 240 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 241 | C.P. brass Bib cock long nose/ long body foam flow without flange |
| 242 | Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect |
| 243 | PVC tube connection of size 15 mm x 450 mm with C.P. Brass nut. |
| 244 | Providing & fixing in position C.P. copper tube connection of approved make (to the approval of Engineer-in-charge) complete in all respect |
| 245 | C.P. copper tube connection of size 15 mm x 600 mm with C.P. Brass nut |
| 246 | Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects. |
| 247 | Dismantling Sanitary fixtures such as eurpoean/Indian/Orissa W.C., PVC / China ware cistern, Wash Hand Basin, Urinal Pot, Sinks and CP Fittings and disposal of dismantled material within a distance of 100 Mtr. complete in all respect as required by Engineer-in-Charge. |
| 248 | Wash Hand Basin / Urinal Pot |
| 249 | Stainless Steel Sink /Mosaic Sink |
| 250 | CP Bib Cock/Angle Cock/Stop Cock/Shower/Bottle Trap |
| 251 | Providing and fixing in position automatic brass Ball Cock in tanks. |
| 252 | Brass Ball Cock with rod and Plastic Ball |
| 253 | 20mm i/d |
| 254 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable lockingarrangement and making necessary holes for inlet, outlet and over flo pipes but withoutfittings and base support for tank. |
| 255 | Triple Layer Tanks (4x2000 Litre) |
| 256 | Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect. |
| 257 | G.I. tank nipple 20mm i/d |
| 258 | Providing & Fixing aluminium doors including material and labour complete in all respects. |
| 259 | Door Size = 2\"-6\" |
| 260 | Door Size = 3\"-0\" |
| 261 | Construction of platform for placing 2000 Litre PVC water storage tank complete in all respects. |
| 262 | Carriage of Malba from site of work to dumping ground. |
| 263 | Providing and installing Automatic Voltage Stabilizer copper winding and having suitable range for input and output of 4 KVA capacity of reputed make along with Ampere Meter, Volt Meter & 3 core wire of 1½ metre length complete in all respect make V-Guard, Liv Guard, Luminous and any other equivalent make. |
| 264 | SUB HEAD:-3- PROVIDING RAIN WATER HARVESTING INCLUDING BORE HOLES, RECHARGE WELLS, PIPE WORK & HAUDIES ETC.- |
| 265 | 3 No. Bore Hole:- |
| 266 | Boring with casing pipe for tubewell in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested , equipment as requried such as hand boring machine and its accessory, transportation to site and vice versa etc. complete in all respect. |
| 267 | Boring with 250mm id Housing Pipe Upto 150 m depth BGL. |
| 268 | Providing, Stringing out PVC pipes as per ISI-4985 (ISI marked with prior approval of Engineer in charge )casting along the Trenches and laying the same in Trenches To correct alignment and gradients, cutting. Jointing and testing complete as per specifications |
| 269 | (160 mm ) o/d pipe of 6kg. /sqcm |
| 270 | Providing & lowering PVC strainer etc. Complete. |
| 271 | Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect. |
| 272 | 150mm internal diameter |
| 273 | Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect. |
| 274 | Supplying of gravel of 1/16\" to 1/8\" sizes including pouring and packing in the annular space between the pipes assembly and the bore. The gravel should be free from, dust, dirt or the vegetable manner as per IS 4097/1967 with latest amendments (to be paid as per actual length of pipe) |
| 275 | 2 No. Recharge Well dia 3mtr x 3mtr:- |
| 276 | Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. |
| 277 | Cement concrete 1:8:16 |
| 278 | With stone aggregates 40mm gauge |
| 279 | mixing by mechanical means using concrete mixer volumetric type |
| 280 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth |
| 281 | 10mm thick Cement Plaster 1:3 |
| 282 | Foot Rest for Manhole- |
| 283 | Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer\"s permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design. |
| 284 | Providing and fixing PVC Mesh Filter Slot size 3 mm |
| 285 | Providing and placing in horizontal layers filtering media screened, washed and cleaned as described below:- |
| 286 | Second Layer :----- Coarse sand screened, cleaned and washed and graded from 3mm to 6mm-Size 3.60mm |
| 287 | Third Layer :----- Bajri screened, cleaned and washed and graded from 6mm to 20mm. Size 6.20mm |
| 288 | Fourth Layer :----- Bajri (Coarse) screened, cleaned and washed and graded from 20mm to 25mm.Size 2.60mm |
| 289 | Providing and fixing MS Angle Iron / MS Sheet Cover for protection of bore hole pit. |
| 290 | 1 No. Recharge Well dia 4mtr x 5m |
| 291 | Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. |
| 292 | Cement concrete 1:8:16 |
| 293 | With stone aggregates 40mm gauge |
| 294 | mixing by mechanical means using concrete mixer volumetric type |
| 295 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth |
| 296 | 10mm thick Cement Plaster 1:3 |
| 297 | Foot Rest for Manhole- |
| 298 | Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer\"s permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design. |
| 299 | Providing and fixing PVC Mesh Filter Slot size 3 mm |
| 300 | Providing and placing in horizontal layers filtering media screened, washed and cleaned as described below:- |
| 301 | Second Layer :----- Coarse sand screened, cleaned and washed and graded from 3mm to 6mm.Size 3.60mm |
| 302 | Third Layer :----- Bajri screened, cleaned and washed and graded from 6mm to 20mm.Size 6.20mm |
| 303 | Fourth Layer :----- Bajri (Coarse) screened, cleaned and washed and graded from 20mm to 25mm.Size 2.60mm |
| 304 | Providing and fixing MS Angle Iron / MS Sheet Cover for protection of bore hole pit. |
| 305 | Detail of Pipe Work:- |
| 306 | Supply of materials: |
| 307 | Providing, Stringing out PVC pipes as per ISI-4985 (ISI marked with prior approval of Engineer in charge )casting along the Trenches and laying the same in Trenches To correct alignment and gradients, cutting. Jointing and testing complete as per specifications (MANUAL) |
| 308 | 90 mm o/d PVC pipe of 4 kgf./ = |
| 309 | 160 mm o/d PVC pipe of 4 kgf./ = |
| 310 | 200 mm o/d PVC pipe of 4 kgf./ = |
| 311 | Construction Work:- |
| 312 | Excavation manually in trenches for pipe lines with straight or open cutting in streets and lanes in built up area where width of street / lane from wall to wall is less than 3 meter including trimming and dressing sides leveling of beds of trenches to correct grade , cutting joint holes, refilling consolidation, watering, including the cost of dewatering of rain water, diversion for traffic, night signals, Providing & fixing caution boards, watching, fencing, etc. and removal of surplus soil from the site upto 15 meter distance complete in all respects.(a)Earth work upto 1.5 m depth (i) All classes of soil except rocky. |
| 313 | 82 Nos. Haudi 0.45m x 0.45:- |
| 314 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. |
| 315 | Cement concrete 1:8:16 |
| 316 | With stone aggregates 40mm gauge |
| 317 | mixing by mechanical means using concrete mixer volumetric type |
| 318 | Cement concrete 1:2:4 |
| 319 | With stone ballast or shingle |
| 320 | mixing by manual means |
| 321 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth |
| 322 | 12.5 mm thick cement plaster 1:2 + Cement rendering on plaster 1mm thick |
| 323 | Providing and fixing RCC MH Cover light duty rectangular single / double seal pattern 450mm x 450mm clear inside opening. |
| 324 | 27 No.Haudi 0.90m x 0.90:- |
| 325 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. |
| 326 | Cement concrete 1:8:16 |
| 327 | With stone aggregates 40mm gauge |
| 328 | mixing by mechanical means using concrete mixer volumetric type |
| 329 | Cement concrete 1:2:4 |
| 330 | With stone ballast or shingle |
| 331 | mixing by manual means |
| 332 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth |
| 333 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. |
| 334 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008), for R.C.C. works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 335 | 12.5 mm thick cement plaster 1:2 + Cement rendering on plaster 1mm thick |
| 336 | Providing and fixing RCC MH Cover light duty rectangular single / double seal pattern 450mm x 450mm clear inside opening. |
| 337 | Electrical Works |
| 338 | RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): |
| 339 | Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 340 | Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. |
| 341 | RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): |
| 342 | Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting andfilling up of chases (with finishing the surface):- |
| 343 | Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories). |
| 344 | RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): |
| 345 | Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 346 | Wiring Networking socket point RJ45 (one module) |
| 347 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: |
| 348 | Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\" deep for walls and CI 3\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 349 | Wiring fan point (With fan box) |
| 350 | Wiring light point |
| 351 | Wiring call-bell point |
| 352 | Wiring 6Amp. wall socket point |
| 353 | Wiring 6Amp. Plug control comprising wall socket point |
| 354 | Wiring 16/20Amp. power plug control point |
| 355 | SURFACE PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: |
| 356 | Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia (ISI Marked) installed on surface etc., complete with PVC boxes (Plastic on surface boxes) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), MS saddle clamp, PVC Circular junction Boxes (Four way 1½\" deep for walls), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material and painting as required:- |
| 357 | Wiring fan point (Without fan box) |
| 358 | Wiring light point |
| 359 | Wiring 6Amp. wall socket point |
| 360 | Wiring 6Amp. Plug control comprising wall socket point |
| 361 | Wiring 16/20Amp. power plug control point |
| 362 | REPLACEMENT OF WIRES, COVER FRAMES, MODULAR SWITCHES, CONCEALED METAL BOXES AND OTHER ACCESSORIES IN THE EXISTING RECESSED CONDUIT PIPE WIRING SYSTEM (WITH MODULAR TYPEACCESSORIES) Derived from 34.01: |
| 363 | Replacement of PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in existing heavy gauge welded conduit pipe 20 mm/25 mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- (Derived From CSR 34.01) |
| 364 | Wiring fan point (Without fan box) |
| 365 | Wiring light point |
| 366 | Wiring 6Amp. wall socket point |
| 367 | Wiring 6Amp. Plug control comprising wall socket point |
| 368 | Wiring 16/20Amp. power plug control point |
| 369 | PVC INSULATED FR COPPER CONDUCTOR CABLES: |
| 370 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 371 | Overall size 1.5sq.mm (Un-sheathed) |
| 372 | Overall size 2.5sq.mm (Un-sheathed) |
| 373 | Overall size 4sq.mm (Un-sheathed) |
| 374 | Overall size 10sq.mm (Un-sheathed) |
| 375 | COPPER CONDICTOR CABLES FOR SPECIAL ELECTRICAL SERVICS: |
| 376 | Supply and erection of CAT 6 with 23AWG solid bare copper conductor, special grade PE insulation with star separator, 4pair unshielded twisted pair (UTP) industrial cable, FR PVC sheathed, class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to Gbps (10GBASE-T) for distance up to apporximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 class E standards left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 377 | Cat 6 Lan Cable |
| 378 | XLPE INSULATED LT CABLES: |
| 379 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE): |
| 380 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 381 | Overall size 10sq.mm (2Core) Un-armoured (Loose) |
| 382 | Overall size 35sq.mm (3½ Core) Un- armoured (Loose) |
| 383 | Overall size 50sq.mm (3½ Core) Un- armoured (Loose) |
| 384 | Overall size 150sq.mm (3½ Core) Un- armoured (Loose) |
| 385 | Overall size 185sq.mm (3½ Core) Un- armoured (Loose) |
| 386 | Overall size 16sq.mm (4Core) Un-armoured (Loose) |
| 387 | HEAVY GAUGE WELDED CONDUIT PIPES: |
| 388 | Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- |
| 389 | Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), White painted suspension rod for ceiling fan. |
| 390 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES: |
| 391 | Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 392 | Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface) |
| 393 | Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) |
| 394 | Heavy Gauge PVC Conduit Pipe 32mm dia. (Flushed) |
| 395 | Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:- |
| 396 | PVC Flexible Pipe 25mm dia. |
| 397 | PVC Flexible Pipe 32mm dia. |
| 398 | GALVANIZED IRON PIPES AND G.I. EARTHING |
| 399 | Supply & erection of G.I. pipe (A-Class) as per IS:1239 (Part-I) 2004 including sockets, bends, inspection boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- |
| 400 | Galvanized Iron Pipe 50mm dia. (A-class) On surface |
| 401 | Earthing earth rod 20 mm dia for providing earth connections upto line earth with G.I. Wire 8 S.W.G. (4mm dia.). The rod shall be tapered at one end and flatted on other end. The hole size 10mm dia shall be drilled on the flatened side for facilitating connection with G.I. wire and thimble etc. The rod shall be erected in ground upto complete length vertically:- |
| 402 | GI Earth rod 20 mm dia., 3 mtr. Long |
| 403 | G.I. EARTHING WIRE/ ROPE (AS ADDITIONAL LENGTH): |
| 404 | Fixing additional length of earthing withG.I. wire/ rope in G.I. pipe (Flushed in wall and floor) with sockets, elbows and Steel hooks including the cost of cutting and filling up of chases (with finishing the surface):- |
| 405 | Additional length G.I. wire 8 S.W.G. (4mm dia.) in 15mm dia. G.I. pipe (Flushed) |
| 406 | COPPER EARTHING: |
| 407 | 8 SWG COPPER EARTHING : |
| 408 | Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 409 | Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long |
| 410 | COPPER EARTHING (Upto 8 metre in Length): |
| 411 | Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 4.50 metre (14.76 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 8metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 3metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 412 | Earthing with 20mm x 3mm Copper Tape (upto 8Metre in Length) |
| 413 | Earthing with 25mm x 3mm Copper Tape (upto 8Metre in Length) |
| 414 | COPPER EARTHING STRIP (AsAdditional Length): |
| 415 | Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:- |
| 416 | Additional Length 20mm x 3mm thick Copper Tape |
| 417 | Additional Length 25mm x 3mm thick Copper Tape |
| 418 | Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:- |
| 419 | Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (On Surface) |
| 420 | Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed) |
| 421 | SUPPLY AND ERECTION OF WIRING ACCESSORIES: |
| 422 | Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame includingfixing & connections and petty material etc.,:- |
| 423 | Modular Blanking Plate (One Module) |
| 424 | Ceiling Rose (Flush Piano type) |
| 425 | Call Bell 220/230 volts AC Ding Dong |
| 426 | BAKELITE SHEET: |
| 427 | Supply and erection of brown bakelite sheet white glazed translucent backside painted 3mm thick (thickness not less than 3mm) on the existing metal box including cutting, fixing and connection of existing switches and sockets and other petty material etc. |
| 428 | Supply and erection of Plastic surface boxes of various sizes (1/2M, 3M, 4M, 6M, 8M, 12M) on surface on wall for mounting modular accessories including fixing and other petty material etc.:- |
| 429 | Plastic Surface Box for Modular Accessories Twelve Module |
| 430 | MINIATURE CIRCUIT BREAKERS/ RCBO\"s/ RCCB\"s: |
| 431 | MINIATURE CIRCUIT BREAKERS: |
| 432 | Supply and erection of Miniature Circuit Breaker MCB\"s for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications includingconnections with suitable size of thimbles/lugs:- |
| 433 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 434 | MCB Double Pole 40amp. (10kA, Curve-C) |
| 435 | MCB Four Pole 40amp. (10kA, Curve-C) |
| 436 | MCB Four Pole 50, 63amp. (10kA, Curve-C) |
| 437 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB\"s/ RCBO\"s/ RCCB\"s: |
| 438 | Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color- coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO\"s/ RCCB\"s in the distribution board (For SP&N distribution board with provision DP MCB\"s/ RCCB\"s/ RCBO\"s as incomer and SP MCB\"s as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB\"s/ RCCB\"s/ RCBO\"s as incomer and SP MCB\"s as outgoings) as per PWD General specifications including connectionswith suitable size of thimbles and bonding to existing earth etc:- |
| 439 | SP&N Double Door Distribution Board 4 way each |
| 440 | SP&N Double Door Distribution Board 8 way each |
| 441 | TP&N Horizontal Double Door Distribution Board 6 way each |
| 442 | TP&N Horizontal Double Door Distribution Board 8 way each |
| 443 | Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:- |
| 444 | Cable End Box for SPN 4Way |
| 445 | Cable End Box for SPN 8 Way |
| 446 | Cable End Box for TPN 6 Way |
| 447 | Cable End Box for TPN 8 Way |
| 448 | SHEET METAL IRON CLAD CHANGEOVER SWITCHES: |
| 449 | Supply and erection of sheet metal Iron Clad Changeover Switch on existing surface with G.I. bolts & nuts/rag bolts and nuts etc., according to the size of holes in the body of the switch including connections with suitable size of thimbles and bonding to the existing earth as per PWD General Specifications: |
| 450 | IC Four Pole Changeover Switch 63amp., 415volts |
| 451 | IC Four Pole Changeover Switch 100amp., 415volts |
| 452 | IC Four Pole Changeover Switch 400amp., 415volts |
| 453 | SHEET METAL BUS BAR CHAMBERS (COPPER STRIPS): |
| 454 | Supply and erection of sheet metal bus- bar chamber (factory fabricated) duly powder coated on existing surface with required 4Nos. of tin plated copper bus- bar strips of suitable length and cross- sectional area mounted on DMC/ SMC moulds at sufficient distance, enclosure made of M.S. sheet 1.6mm thick with hinged cover and lock, fitted with dust excluding gaskets and secured with sufficient no. of cadmium plated iron screws and of given overall dimensions and to be fixed with G.I. bolts and nuts/ rag bolts and nuts etc. complete with all accessories including connections with suitable size of thimbles, bonding to the existing earth and painting etc. as desired by the Engineer-in-charge at site: |
| 455 | Bus Bar Chamber 63amp., 415volts Overall Dimensions (350mm x 450mm x 150mm) nominal |
| 456 | Bus Bar Chamber 100amp., 415volts Overall Dimensions (350mm x 450mm x 150mm) nominal |
| 457 | Bus Bar Chamber 200amp., 415volts Overall Dimensions (780mm x 510mm x 215mm) nominal |
| 458 | LT PANELS & MCCB\"s (MOULDED CASE CIRCUIT BREAKERS): |
| 459 | LT PANELS: |
| 460 | Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55).Fabrication:- Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel. |
| 461 | The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc. |
| 462 | The fabrication should be such that all the memberi.e. vertical/horizontal should be detachable typei.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition. |
| 463 | Painting:- The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work .Busbars:-The panel shall be provided with TPN aluminium busbar of suitable size according to the size of MCCB\"s. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium (1A/Sq.mm). All Busbar will be air insulated with codified in Red, Yellow, Blue & Black as per standard for cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports. |
| 464 | Metering:-The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT\"s & L.E.D. type indicator etc.Manufacturer of Panel should be CPRI Approved (Approval not older then 5 years)& ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard) The Concerned contractor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site.Detail of capacities of MCCB\"s to be installed in the cubical panel Enclosure (Excluding the cost of MCCB\"s) as per following:- |
| 465 | LT Panel enclosure having space for 1No. Incomer MCCB 400Amp. and 4Nos. outgoing MCCB\"s 100amp. to 160amp. according to the requirement at site (Approx. size 2025 x 1100 x 400mm) |
| 466 | MCCB\"s (FOR PANELS & SHEET ENCLOSURE): |
| 467 | Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- |
| 468 | MCCB Four Pole 63/80/100amp., 415volts,≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 469 | MCCB Four Pole 125amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 470 | MCCB Four Pole 200amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 471 | MCCB Four Pole 400amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting |
| 472 | MCCB\"s (MOULDED CASE CIRCUIT BREAKER): |
| 473 | Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- |
| 474 | MCCB Four Pole 63/80/100amp., 415volts,≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 475 | MCCB Four Pole 200amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 476 | MS SHEET ENCLOSURE FOR MCCB\"s: |
| 477 | Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:- |
| 478 | MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm) |
| 479 | MS Sheet Enclosure having provision for MCCB 200-630Amp.with extended rotary handle (Approx. Size 750mm x 300mm x 250mm) |
| 480 | SINGLE ARM BRACKETS FOR GI PIPE POLE: |
| 481 | Supply and erection of G.I. Pipe 40mm dia. (A-class) Single arm bracket of suitable length give a total overhang at a tentative angle of 100/105º, the bracket should be fixed on the top of the GI pipe pole having top outer dia. 80mm/100mm with GI reducer of suitable size with two coats of an approved aluminium paint complete in all respect as approved by the Engineer-in-charge at site:- |
| 482 | Single Arm Bracket 1.5 metre Long with G.I. Reducer 80mm x 40mm |
| 483 | 3-STEPPED STEEL TUBULAR POLE: |
| 484 | Supply and erection of 3-Stepped steel tubular swaged and welded pole (410-SP Mpa) of suitable length confirming to IS: 2713- (PART-II)-1980 (Steel tubesconfirming to IS: 1161-1979, UTS 42 kgf/ Sq.mm) to fix up to a required planting depth below ground level in a hole of excavation about 45 cm dia. and suitable depth to fill up to 15 cm below G/L with 1:2:4 cement concrete mixture including painting of pole with two coats of approved aluminium paint as required:- |
| 485 | Overall length 7 metre, with planting depth1.25 metre, length of sections 4 metre, 1.5 metre and 1.5 metre (Bottom, Middle and Top respectively), Outer dia and thickness of sections 114.3mm x 4.5mm, 88.9mm x 4.05mm and 76.1mm x 3.25mm (Bottom, Middle and Top respectively) with approximate weight 73 kg. (410 SP-2) and base Plate weight 7.5 kg. of size 12mm thick about 30 cm dia. |
| 486 | CEMENT CONCRETE MUFFS: |
| 487 | Making of Cement Concrete muff of suitable size and length with 1:2:4 cement concrete mixture. The muff is to be made around the steel tubular pole sufficient to completely flush a SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirming to IS:14772, inner dimensions 250mm x 200mm x 100mm with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB\"s). The SMC junction box is to be fixed with the pole by a MS flat clamp of size 20mm x 2mm thick. PVC pipe 40mm dia. (2No.x0.60m) should be provided for incoming and outgoing cables. The outer surface of the muff shall be finished with pure cement& two coats of white snowcem complete in all respect as approved and desired by the Engineer In-Charge at site:- |
| 488 | Cement Concrete Muff of Overall Size 450mm dia., 80cm Long |
| 489 | Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals& 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB\"s) complete in all respect as approved and desired by the Engineer In-Charge at site:- |
| 490 | SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 140mm x 140mm x 95mm with hinged water tight cover with locking arrangement |
| 491 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: |
| 492 | Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 493 | Double Walled Corrugated HDPE Pipe 50/38mm (Outer/ Inner dia.) |
| 494 | Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.) |
| 495 | Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:- |
| 496 | Aluminium thimble cable Core size 50sq.mm |
| 497 | Aluminium thimble cable Core size150sq.mm |
| 498 | Aluminium thimble cable Core size185sq.mm |
| 499 | Supply and erection of Heavy duty Exhust Fans 300mm sweep 900RPM complete with aluminium louver shutter Canon Make, double ball bearing, longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. |
| 500 | Supply and erection of LED batten 20 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/ IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary. |
| 501 | Supply and erection of LED batten 40 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/ IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 502 | Supply and erection of 3-Star rating AC Ceiling Fan 1200mm (48\") suitable for single phase ACsupply with double ball bearing, copper wound,anti corrosive 3Nos. of blades and body, white in colour. Down rod mounting type. The product should posses a minimum air delivery of 210CMM. The product should have a manufacture\"s guarantee/warranty of minimum 2 years.The product should be complete in all aspects with fan motor, conopy set, shackle kit, etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site. |
| 503 | Supply and erection of LED Street Light Luminaire 45 watt, Supply voltage 140-270 volts AC supply, 50Hz ± 35 (including BIS Certified potted single driver with screen or laser printing logo LED driver) with pressure die cast or extruded alumininum housing with control gear (IP 66 protection) THD<10%, CRI minimum 70, High power LED (with wattage 1 to 5 Watt) with mandatory secondary lenses, toughened glass fitting, Min IK07, 4 KV SPD within driver and 10KV external SPD, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site . LED Fitting as per Specifications approved by Hon. Tech. Advisor to Punjab Govt. vide Letter ION no:- AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary. |
| 504 | Supply and Erection of LED Post top 40/45 watt Clear Acrylic Cover opal diffuser Supply Voltage140-270 volts AC supply 50Hz ± 3 % (including LED driver) with IP 65 protection CCT 5700K, High power LED with wattage 1 to 5 watt, Resistant to impact and corrosion with symmetrical light distribution, 5year warranty including their drivers complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary. |
| 505 | Supply and erection of LED Flood Light 80watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon\"ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab. |
| 506 | SITC of 8 Port 10/100/1000 Mbps L2 Managed Smart Data switch having IEEE 802.3 10BASE-T Ethernet, IEEE 802.3u 100BASE-TX Fast Ethernet, IEEE 802.3ab 1000BASE-T Gigabit Ethernet, IEEE 802.3z Gigabit Ethernet, IEEE 802.3x Flow Control, 802.1p priority, Energy Efficient Ethernet, Switching capacity 36 Gbps, HOL blocking prevention, 802.1p priority based, hardware queues, priority queuing and Weighted Round-Robin (WRR) Jumbo frame 2 No. SFP/Copper UPLINK 1GBPS Each |
| 507 | Less Dismantle Please Enable Macros to View BoQ information |