| 1 | Taking down Black board / writing board / notice board of any description, any size etc complete all as directed. |
| 2 | S&F in repairs2nd class hardwoodPlain/moulded fillets. square, rectangular or triangular in section , clean sawn, secured with nails or brads fixed in repairs. exc 3 sq cm & n exc 6 sqcm etc complete all as secified and as directed |
| 3 | S&F in repairs 2nd class hardwoodPlain/ moulded fillets. square,rectangular or triangular in section , clean sawn, secured with nails or brads fixed in repairs. exc 6 sq cm & n exc 13 sqcm etc complete all as specified and as directed |
| 4 | M&L for fillets, bullnosed, splayed, chamfered or rounded on one edge or face clean sawn, secured with secret screws or brads exc 13 sq cm & n exc 25 sqcm etc complete all as sped and as directed |
| 5 | M&L for 12mm thick Plywood, grade BWP, type BB fixed with screws to timber frame work on wall etc complete all as specified and as directed. |
| 6 | Supplied and fixed 8 to 10mm thick Super decorative Charcoal panel for Interior wall décor, 3D wall panel, one side & edges tongued and grooved or rebated and fixed with adhesive to the dados / wall etc complete all as specified and as directed. |
| 7 | M&L for preparing the old wooden surfaces of any description,with mechanical wall sander (having mechanical vacuummechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7\"/9\" to make the surface free from dust, loose paint etc or flaming polish which ever is suitable for site and fill the gap or crack with wood filler, POP or putty etc by removing latches / sliding door bolt and refixing the same in the door and apply one or more coats of french polishing till the desired finish is obtained complete all as specified and directed. |
| 8 | M&L for preparation of old treated wooden Surfaces of any description, over 10cm in width or girth, fill the gap or crack, hole with wood filler or POP, putty etc including cleaning andmake the surface smooth and applying Woodkeeper 1 K PU by Berger or equivalent etc till the surface became fine glosy finish complete all as specified and directed. |
| 9 | M&L for 16 to 18 mm thick granite (of any type any colour) work (table rubbed 7 polished ) in window door cills/jambs, platformlike in cement morter (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shed with granite etc complete all as specified and directed. |
| 10 | Dismantling offloor, hearth or wall tilinng incl cement mortar bedding (but not backing) and rubbish offincluding rubbish off outside of MOD land complete all as specified and as directed. |
| 11 | M&L for coloured joint free homogeneous glazed dark shade full body vitrified tiles as per IS 15622: 201, water absorption <0.05%, MOH hardness > 6, breaking strength >1500, high abrasion and stain resistant PEI III-V (Gloss PEI II-III) dark shade 9-10 mm thick (square/ rectangular) area of each tiles exceeding0.70 sqm but not exceeding 1.00 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with spacer 3-5 mm thick and grouting with epoxy grout including wastage on tiles i.e. raking, circular cutting or notching etc over 20mm thick screed bed in CM (1:4) etc complete all as specified and as directed.Note: Curve floor surface hence no extra measurement to be given to the contractor for wastage. |
| 12 | M&L for Glazeddark shade full body Vitrifiedtiles dark shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.70 sqm but not exceeding 1.00 sqm, in skirting / wall tile etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with Raking, cutting and waste on glazed tiles over 10mm thick backing coat in CM (1:3) complete all as specified and as directed. |
| 13 | M&L for complete removal of existing treatment form wall to make the surface free from dust, loose paint and loose plaster by scrapping manually / mechanically as directed by engr-in-charge (nails, screws if any to be removed properly before scraping) complete all as specified and directed. |
| 14 | Ditto all as per item No 13 abovebut for Ceiling surface complete all as specified and as directed. |
| 15 | M&L for providing and applying water proof cement base putty of 1mm thick over prepared old plastered / old painted wall surface to prepare the surface even and smooth upto desired finishes by manually / mechanical means etc complete all as specified and directed. |
| 16 | Ditto all as per item No 15 above but for Ceiling surface complete all as specified and as directed. |
| 17 | M&L for one coat of acrylic water based interior grade primer @ 0.8 ltr (undiluted)/10 sq mtrs diluted with water in 1:1 ratio to be applied on wall with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface for painting of subbsequent coats complete all as specified and directed. |
| 18 | Ditto all as per item No 17 above but for Ceiling surface complete all as specified and as directed. |
| 19 | M&L for applying two coats of oil bound distemper on wall using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper shall be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed. |
| 20 | Ditto all as per item No 19 above but for Ceiling surface complete all as specified and as directed. |
| 21 | S&F powder coated (wooden finished colour) aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom andsideswithrequired EPDM rubber/ neoprene gasket etc., aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/ paneling, chromium plated brass/ stainless steel screws complete as per architectural drawings all as specified and as directed. |
| 22 | S&F 4mm thick frosted sheet glass / glass strip area n.exc. 0.5 sqm ordinary quality andglazing fixed to aluminium and wooden window / ventilator shutters / steel windows with glazing cllips and putty etc all as specified and as directed. |
| 23 | S&F, Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturs etc complete all as specified & directed |
| 24 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples etc complete all as specified & directed |
| 25 | S&F including hacking out from wooden surfaces 4mm thick frosted sheet glass / glass strip area n.exc. 0.5 sqm ordinary quality andglazing fixed to aluminium and wooden window / ventilator shutters / steel windows with glazing cllips and putty etc all as specified and as directed. |
| 26 | S&F in repairs antique / ornamental Stainless steel hevy duty Hinges, Aldrop, tower bolt, handles, latches, window / door stopper, sliding door bolt etc match to existing for doors, windows, ventilators & banister all as specified and as directed Make : M/S J Errana, Shri Laxmi Industries (P) Ltd, Classic or equivalent |
| 27 | M&L for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along internal wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete all as specified and directed |
| 28 | Taking down exiting copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed. |
| 29 | M&L for concealed point wiring in and including new PVC conduit medium grade with the help of multi-strandedunsheathed FRLSH copper cable 1.5 sqmm 650/1100Vconforming IS:3419 -1988 adhereing to colour codeincluding earth wire of the size 1.5 Sqmm green colored with modular steel or cast iron terminal boxes and modular cover plates as required at site including making good the distrubed surfaces and matching it with existing surface for the following :-(a)One light/Fan point controlled by one way switch 6 Amps 240 volts One light/Fan point controlled by one way switch 6 Amps 240 volts |
| 30 | (b) Ditto all as per item No. 29 above but One 3 pin socket outlet, 5/6 Amps on the same board with other switches |
| 31 | (c)Ditto all as per item No. 29 above but One 3 pin socket outlet, 5/6 Amps, independent |
| 32 | M&L concealed point wiring with 4 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unseathed cable in and including PVC conduit not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unseathed FRLS cable size 4 sq mm copper conductor as earth wire to common earth dolly all as specified and directed |
| 33 | S&F modular switch 1 way 6 A 1 module all as specified and directed |
| 34 | S&F Modular socket 6 A 2/3 Pin2 module all as specified and directed |
| 35 | S&F modular switch 1 way 16 A 1 with indicator module, 240 volts all as specified and directed |
| 36 | S&F Modular socket 6 A/16A 2/3 Pin2 module, 240 volts all as specified and directed |
| 37 | S&F modular BLDC fan regulator, 2 module, suitable for ceiling fan of 1200/1400mm sweep all as specified and directed |
| 38 | S &F for LAN RJ-45 Jack With Cat 6 socket UTP Catwith transparent shutter 1 module alongwith flush metal box 1 module and front cover plate 1 module all as specified and directed |
| 39 | S &F for HDMI socket with transparent shutter 1 module alongwith flush metal box 1 module and front cover plate 1 module all as specified and directed |
| 40 | S&F in replacement for ceiling rose, 3 terminals /PVC/Polycarbonate, isolated body all as specified and directed. |
| 41 | M&L for Provn ofPVC conduit for Telephone/TV/LAN/ CCTV/PAnot less than 25 mm with Cutting chases for concealed for Telephone/TV/LAN/ CCTV/PA wire, pinning in and making good to surface where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., cutting not exc 10 cm girth including 3 mm thick wall care putty on wall, making surface matching to adjacent surface all as specified and directed.Note: a). Rate quoted shall deemed to include cost oftaking down existing Telephone/ TV/LAN/ CCTV/PA wire. .b)Rate quoted shall deemed to include cost ofrelaying existing Telephone/TV/LAN/CCTV/PA wire through PVC conduit. |
| 42 | S&F in repalcement recess mounted 2\" x 2\" LED Panel lights 40 W LED 5700K, 240Volts and glare free symmetrical illumination suitable for Armstrong/Grid ceiling, Environmental friendly, new generation, energy saving,high power LED as a light source with clear diffuser and separate replaceable electronic driver including connecting with twin core wire and also matching to the adjacent ceiling surfaces carefully all as specified and directed. Note: The quoted price shall include the cost of Light and its driver. |
| 43 | M&L for repalcing the down rod of ceiling fans with 5 feet GI ceiling fan hanging down rod with necessary clamp accessories all as directed. |
| 44 | Taking down ceiling fan/Exhaust Fan, sealing cable end,dismantling blades and removing fan and blades to AGE E/M store as directed |
| 45 | S&F ceiling fan complete with blades, down rods and other accessories, 230 V, 1200 mm sweep with Minimum air delivery of 210 CMM BEE Five star rated with brushless direct current motor (BLDC), white/Ivory in colour complete all as specified and directed |
| 46 | S&F of high speed wall mounted fan withof sweep 400 mm,,Full copper motor,auto thermal overload protection,compact style and powder coated gurads & pull cord switch for speed regulation and oscillation control including connectng up the power cord to the socket and necessary fixing accessories all as specified and directed. |
| 47 | M&L for cutting chases for concealed conduit wiring, pinning in and making good to surface where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., cutting not exc 10 cm girth including 3 mm thick wall care putty on wall, making surface matching to adjacent surface complete all as specified and directed. |
| 48 | Taking down exiting copper/aluminium sub main wiring complete for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc as directed |
| 49 | M&L forconcealed sub main wiring with two single core PVC insulated FRLScables with stranded copper conductors 2.5 Sqmm , 1100 Volts grade in and including PVC conduit medium grade with all fitting & other accessories and copper cable 2.5 sqmm continuous earth wirecomplete all as specified and directed. Note: Two runs of 2.5 Sqmm cable with 01run of 2.5 Sqmm earth wire along with PVC conduit medium grade shall be measured as one RM |
| 50 | M&L forconcealed sub main wiring with two single core PVC insulated FRLScables with stranded copper conductors 4 Sqmm , 1100 Volts grade in and including PVC conduit medium grade with all fitting & other accessories and copper cable 4 sqmm continuous earth wirecomplete all as specified and directed by Engr-in-charge. Note: Two runs of 04 Sqmm cable with 01run of 4 Sqmm earth wire along with PVC conduit medium grade shall be measured as one RM |
| 51 | M&L forconcealed sub main wiring with Two single core PVC insulated FRLScables with stranded copper conductors 10 Sqmm , 1100 Volts grade in and including PVC conduit medium grade with all fitting & other accessories and copper cable 10 sqmm continuous earth wirecomplete all as specified and directed by Engr-in-charge. Note: Two runs of 10 Sqmm cable with 01 run of 10 Sqmm earth wire along withPVC conduit medium grade shall be measured as one RM |
| 52 | S&F in replacement sheet metal enclosures double pole MCB 20 Amps with a two pin and earth plug and socket complete with all accessaries etc all as specified and directed |
| 53 | S&F in replacement MCCB with rating of 125 Amps, 415 Volts 3 pole with 16 kA breaking capacity,thermal magnetic asdjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capcity(Icu). MCCBshould be with suitable spreaders and phase barriers for each terminals complete all as specified and directed |
| 54 | S&F in replacement factory made epoxy powder coated Distribution Board TP & N 4way double door (VTPN MCCB DB) MCCB as In comer, with metal door (IP-43 protection) fabricated from CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout flush to wall and making good disturbed surface and touch up with the same finishescomplete all as specified and directed Note:MCBs/ MCCBs will be measured and paid seperately under respective Sch A item in the schedule |
| 55 | S&F in replacement MCB SP 6 to 32 Amps 240V,10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing complete all as specified and directed |
| 56 | S&F in replacement of MiniC Curve MCB SP 32 Amps working on 240 volts, 50 HZ,10 KAall as specified and directed. |
| 57 | M&L for Earthing complete with galvanised iron earth plate electrode 600 x 600 x 6mm as earthing lead buried directly in ground vertically to depth not less than 2.25 mtr below GL with the top edge of the plate not less than 1.5 mtr from GL, connected to GI earth lead of 4.0mm dia, by means of bolts & nuts, to GI and connected to earthing test point all as shown in elecrical plate No. 3 of SSR Part-I of 2009* specified or indicated and testing on completion including excavation / earth work in any type of starta, PCC (1:3:6) type C1 earthing chamber pre cast slab 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric (XPM) weight not less than 4 KG/sqm cast iron frame, funnel with wire mesh GI watering pipe of 20 mm bore medium grade and lugs with and including GI earth wire 4 mm dia with GI protection pipe of 15 mm medium grade 7.5 meter long etc complete tested on completion all as specified and directed.Note: a). Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. b). GI wire above 7.5m will be measured and paid seperately. |
| 58 | M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe orfixed to poles or any other indicated situation for loop earthing etc. asrequired 4 mm dia galvanised iron or steel wire ll as specified and directed |
| 59 | Supply, install, commissioning and testing of commercial Air curtain unit of size 40\" x 78\" for prevention of dust and conditioned air losses, single phase, 220 V, 50 HZ, made out of MS/CRCA sheet of minimum thickness 18 gauge finished with two coats of red oxide primer and final coat of synthetic enamel paintor powder coated (oven baked) with MS - CRC 18 gauge square perforated suction grills, Aluminium alloy fans and single phase electric motor, nozzles etc, complete with fittings and accessories so as to produce 1 - 1.5 m/sec air velocity at floor level for door opening as specified and directed. |
| 60 | All as per Item Ser No. 1 but size 52\" x 78\" of Air Curtain unit. |
| 61 | All as per Item Ser No. 1 but size 70\" x 78\" of Air Curtain unit. |
| 62 | M&L for Point wiring (in new concealed conduits to surfaces), modular type, for 3/6-pin, 15 Amps,socket outlet on independent board with 4.0 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLSH, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications all as directed and including FRLSH PVC green insulated unsheathed 4.0 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed |
| 63 | Supply and fixing modular cover plate with frame (matching colour with wall/ wall panelling) for 4 module complete all as specified and directed. |
| 64 | Supply and fixing modular metal flush box of 4 module complete all as specified and directed. |
| 65 | Supply and fixing Modular switch 1 way 16A, 1 module, 240 volts complete all as specified. |
| 66 | Supply and fixing Modular Socket 6A/16A - 2/3 pin combined 2 module, 240 volts complete all as specified and directed. |