| 1 | Supply only RGB/RGBW surface mounted Narrow (10°/20°) beam Flood luminairewith suitable driverfor outdoor applications of Facade Lighting, depending on Client and site requirement. Luminaires should be enabled with high/mid power LEDs, should consists of anti-aging and anti-UV high optical efficiency temperature resistant lenses, suitable for architectural lighting as per site requirement.Power consumption should be40W to 50W atsteady state full intensity, Luminaire luminous flux range of 1800- 2000 Lm. Power factor of complete luminaire 0.95 at full intensity. Luminaire should be compatible for DC24v/48V power supply with suitable integral/non- integral power supply unit. Luminaire should be compatible to DMX512 control protocol. The luminaire should have powder coating aluminium housing. Ingress Protection IP 66Impact resistance level IK 07. Operating Temperature: -10°C to +50°C,Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. Manufacturer should submit >> Design Simulation, Technical Data Sheets , LM79, LM80 Reports , Fixture IP Testing Report as Separate all technical Parameters should comply IS 10332 Standards Approved complete all as specified and directed. |
| 2 | Supply only Warm White ( 2700 K ) surface mounted wide beam Flood luminairewith suitable driver for outdoor applications of Facade Lighting, depending on Client and site requirement. Luminaires should be enabled with high/mid power LEDs, should consists of anti-aging and anti-UV high optical efficiency temperature resistant lenses, suitable for architectural lighting as per site requirement. Power consumption should be 40 W to50W at steady state full intensity, Luminaire luminous flux range of 1800- 4000 Lm. Power factor of complete luminaire 0.95 at full intensity. Luminaire should be compatible for DC24v/48V power supply with suitable integral/non- integral power supply unit. Luminaire should be compatible to DMX512 control protocol. The luminaire should have powder coating aluminium housing. Ingress Protection IP 66 Impact resistance level IK 07. Operating Temperature: -10°C to +50°C, Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. Manufacturer should submit >> Design Simulation, Technical Data Sheets , LM79, LM80 Reports , Fixture IP Testing Report as Separateall technical Parameters should comply IS 10332 Standards complete all as specified and directed.. |
| 3 | Supply only RGB/RGBW surface mounted Narrow / Medium (25°/30°) beam linear wall Grazer luminaire (1000 mm)with suitable driverfor outdoor applications of Facade Lighting, depending on Client and site requirement. Luminaires should be enabled with high/mid power LEDs, should consists of anti-aging and anti-UV high optical efficiency temperature resistant lenses, suitable for architectural lighting as per site requirement. Power consumption should be 40W to 55 W at steady state full intensity, Luminaire luminous flux range of 2000- 4000 Lm. Power factor of complete luminaire 0.90, at full intensity. Luminaire should be compatible for DC24v/48V power supply with suitable integral/non- integral power supply unit. Luminaire should be compatible to DMX512 control protocol. The luminaire should have powder coating aluminium housing. Ingress Protection IP 66 and above. Impact resistance level IK 06. Operating Temperature: -10°C to +50°C, Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. Manufacturer should submit >> Design Simulation, Technical Data Sheets , LM79, LM80 Reports , Fixture IP Testing Report as Separateall technical Parameters should comply IS 10332 Standards Approved complete all as specified and directed. |
| 4 | Supply only RGB/RGBW surface mounted Narrow / Medium (25°/30°) beam linear wall Grazer luminaire (1000 mm)with suitabledriver for outdoor applications of Facade Lighting, depending on Client and site requirement. Luminaires should be enabled with high/mid power LEDs, should consists of anti-aging and anti-UV high optical efficiency temperature resistant lenses, suitable for architectural lighting as per site requirement. Power consumption should be 18W to 25W at steady state full intensity, Luminaire luminous flux range of 700- 900 Lm. Power factor of complete luminaire 0.90, at full intensity. Luminaire should be compatible for DC24v/48V power supply with suitable integral/non- integral power supply unit. Luminaire should be compatible to DMX512 control protocol. The luminaire should have powder coating aluminium housing. Ingress Protection IP 66 and above. Impact resistance level IK 06. Operating Temperature: -10°C to +50°C, Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. Manufacturer should submit >> Design Simulation, Technical Data Sheets , LM79, LM80 Reports , Fixture IP Testing Report as Separateall technical Parameters should comply IS 10332 complete all as specified and directed. . |
| 5 | Supply only RGBW Neon Flex strip Light for outdoor facade lighting .Luminaires should be enabled with high/mid power LEDs, should consists of anti-aging and anti-UV high optical efficiency temperature resistant lenses, suitable for architectural lighting as per site requirement. Power consumption should be 14 W/ mtr to15w/m at steady state full intensity complete all as specified and directed. . |
| 6 | Supply only Aluminium Profile for Neob Flex Light high Grade complete with all accessories Complete all as specified and directed |
| 7 | Supply and Fix BollardLuminiare System Wattage should be10W to 15W , Pf > 0.9 at full load. Input voltage 240V AC. Luminaire CCT to be 3000K + 255K. Product should be IP65. Made of 2.8mm thick MS material.Luminaire base 150mmX150mm and height 600mm Lumens ,Output 700 to 900 Lumens . Manufacturer should submit >> Design Simulation, Technical Data Sheets , LM79, LM80 Reports , Fixture IP Testing Report as Separate complete with all accessories Complete all as specified and directed |
| 8 | Supply only DMX controller DMX 512 x 2 (1024 channels), with Clock & Calender Triggering, 4N output Ports, USB and Ethernet connectivity port for programming / control,and Power Supply included micro SD card.complete with all accessories Complete all as specified and directed |
| 9 | Supply only DMX Splitter / Booster - Individual optical isolation per port. Housing types: Box. Min. 08 Port DMX Outputs per universe DMX line termination complete all as specified and directed. |
| 10 | Supply only DMX cable of (Two pair) having one 22/24AWG pair stranded (7x30) tinned copper conductors, twisted pairs, overall Beldfoil shield (100% coverage) plus tinned copper braid, PVC jacket Cable.complete with all accessories Complete all as specified and directed |
| 11 | Supply only water proof (IP 67 rating) Male-Female Connector set (Same as Light Connectors) for connecting DMX cables complete all as specified and directed.. |
| 12 | Supply only water proof (IP 67 rating) XLR connector cable Male to Femaleset for connecting DMX cables complete all as specified and directed.. |
| 13 | Supply only 1.1 kV grade 3C x 1.5 sq.mm., stranded copper conductor, PVC insulated cable for AC source complete all as specified and directed.. |
| 14 | Supply only 1.1 kV grade 3C x 2.5 sq.mm., stranded copper conductor, PVC insulated cable for AC source complete all as specified and directed. |
| 15 | Supply only 2C x 2.5 sq.mm., stranded copper conductor, PVC insulated cable for DC Supply complete all as specified and directed |
| 16 | Supply only 2C x 4 sq.mm., stranded copper conductor, PVC insulated cable for DC Supply complete all as specified and directed |
| 17 | Supply only water proof DC POWER SUPPLY UNIT(Driver). 200 to 250 wattcomplete with all accessories Complete all as specified and directed |
| 18 | Supply only Distribution Box VTPN 4 way with MCCB 160 Amps 16 KAwith 12 Nos of SP MCBs 6 to 32 Amps complete with all accessories Complete all as specified and directed |
| 19 | Provision for Programming of software with 08 no of themes by qualified rep of OEM complete testing and trail run of themes as per site requirement upto satisfaction and approved by GE for DMX control system complete with all accessories Complete all as specified and directed |
| 20 | Installation Charges incluiding supply of accessories like-screws, fastner, angles, JB. Fixing of Panel, Conduiting, Cabling, luminary fittings, controller ,Distribution Box,DMX Splitter / Booster,DMX controller,Aluminium Profile,digital timer switch distribution board,MCB etc.complete all as specified and directedNote: (i) Items like Conduiting, Cabling, luminary fittings, controller ,Distribution Box,DMX Splitter / Booster,DMX controller,Aluminium Profile,digital timer switch, DBs, MCB etc., shall be measured and paid separately under respective supply only item of thisBOQ. (ii) Miscellanious items required during installation expect supply only items under this BOQ shall deemed to be included in unit rate quoted under this item |
| 21 | M&L XLPE insulated, armoured heavy duty electric cable with aluminium multistrand conductor, 1100 volts grade, cross sectinal area 6 sqmm 4 core complete all as specified and directed |
| 22 | Excavation in trenches in hard/dense soil n.exc 1.5 M wide and not exceeding 1.5 mts in depth in wide for laying of cables and n exc 1.5 mtr in depth and getting out incl dressing/trimming sides and levelling/grading and ramming of bottom of excavation complete all as specified and directed. |
| 23 | Returning and filling in, including spreading and well ramming in layers n exc 25 cm all as specified and directed. |
| 24 | Removing excavated surplus soilto a distance n exc 50 m anddepositing where directed at a level n exc 1.5 mtr above starting point complete all as specified and directed. |
| 25 | M&L PCC 1:3:6 type C-2 (using 40 mm size graded stone aggregate) as in foundations, filling and mass concrete for bollard lights complete all as specified and directed |
| 26 | M&L for PCC 1:2:4 type B-2 (sing 40 mm size graded stone aggregate)as in coping of bollard lights including necessary form work as required complete all as specified and directed |
| 27 | M & L for road surface reinstatement for a 40mm diameter GI medium grade pipe road crossing. This includes cutting, installing, and all associated labor, materials, tools, and plant (T&P) as specified, including all required Plain Cement Concrete (PCC) work complete all as specified and directed.Note: The quoted rate must be inclusive of:1.The cost of the 40mm diameter GI medium grade pipe.2.All costs associated with restoring the disturbed road surface to match the existing.3.All costs associated with the required Plain Cement Concrete (PCC) work.\" |
| 28 | Supply only distribution box 2 Module 230V, 5 HZ, IP-65 & IK-09 Class-II, weatherproof cabinets, door and cabinet fully reversible, removable chassis and faceplates, including weatherproof glands, rails qty-1 Nos, coppper fork type 100 A busbars as short link including end caps,complete all as specified and directed Make: Legrand Catpart No 601932 or equvaleint make as mentioned at list of makes in PS |
| 29 | Supply only C Curve MCB SPN 10 Amps working on 240 volts, 50 HZ,10 KAall as specified and directed |
| 30 | Supply and laying 40 mm outer dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection complete all as specified and directed |
| 31 | Supply only digital timer switch distribution board, factory assembled in powder coated sheet steel enclosure, comprising of 40 Amps 3 Pole MCB, power contactor and 230V digital time switch for controlling LED/SV etc street lights ,including earth work for fixing Timer switch distribution Board and shall be provided 4 Nos 35x35x4mm thick angle iron supports of not less than each 0.6 mt height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement complete all as specified and directed |
| 32 | Supply only DMX signal decoder for LED strips complete all as specified and directedNote for srl item No.1 to6, 8 to 18, 28, 29, 31 &32:installation/fixing for supply only items shall be measured and paid under srl item No..20 |