| 1 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including M&L for taking out embedded portion of posts from any position and making good the disturbed surface on natural ground complete all as specified and directed. |
| 2 | Demolition of reinforced cement concrete/jafri wall of any descritption and in any position not otherwise speccifically provided for complete all as specified and directed. |
| 3 | M&L for providing, cement concrete Type B1 1:2:4 using 20mm graded stone aggregate in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates (Bed Block), watertroughs and the like including weathering, slightly rounded or chamfered angles and throating, directed complete all as specified and directed. |
| 4 | M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions (Square, rectangular or polygonal) with and including fair finished complete all as specified and directed. |
| 5 | Dismantling fencing wire mesh, any type complete all as specified and directed. |
| 6 | Supply only chain link MS galvanisd fencing, any size or type complete all as specified and directed. |
| 7 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed. |
| 8 | S&F in repairs galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. (each line wire to be measured) complete all as specified and directed. |
| 9 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 10 | S&F mild steel framed work of any reqd shape such as ornamental grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, door chowkats of angle or iron safety door, fabrication to decorative type main entrance door upto 3.00mtr height of each leaf, other section and similar works complete of Gde Fe-290 Gde E-165 including welding etc complete all as specified and directed.(Note : Rates to be included in this items of all decorative type desgin fabrication materials (factory made arrows of reeqd size) handles, heavy duty pintle hinges, necessary locking system for iron gate as approved by the Engr-in-Charge). All materials to be measured in kg. |
| 11 | S&F mild steel posts and struts in fencing including cutting tops to shape directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 12 | S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe-410-W Gde E-250 Quality-A with and including including power drilling, cleaning of holes by air pressure then fastner/nut & bolts should be inserted in holes that should be filled with epoxy to ensure the bond as per manufacturer recommendation complete all as specified and directed.(Note : Work will be carried out upto 8 mtr height as per direction of Engr-in-Charge and all fabrication materials including fastner/nuts & bolts to be measured in kg). |
| 13 | M&L for preparation of new or previously untreated steel surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primercomplete all as specified and directed. |
| 14 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, any description and in any position on slope roof complete all as specified and directed. |
| 15 | S&F pre painted crimp curved galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 16 | S&F 1mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 fixed with self tapping screws complete all as specified and directed.. |
| 17 | S&F in repair 4.5mm thick hollow polycarbonate wall sheets in required shape, size and colour fixed with coach screw/self tapping screw and washer with iron frame work of fencing etc.complete all as specified and directed. |
| 18 | S&F in repairs Stainless steel (SS) letter (powder coating 50 micron of any approved colour) fixed on granite/ACP cladding or steel sheet with ornamental and intricate design in English and Hindi complete all as specified and directed. (Size of letter : Height not less than 200mm and upto 300mm) (Note : Work will be carried out upto 6 mtr height as per direction of Engr-in-Charge. |
| 19 | S&F in repairs 3mm thick PVDF coating aluminium composite for wall cladding/ceiling on Facia, column and other decorative faces in required shape and size such as rounding in circular/semi circular, square/rectangular/flat including appropriate aluminium section frame work and gap filling materials by using high-performance weatherproof silicone as per manufacturer\"s instructions and as approved by Engr-in-Charge at any description and in any position with and including scaffolding/shuttering any type required to execute the work complete all as specified and directed. Make : Eurobond or in equivalent. (Note : Work will be carried out upto 6 mtr height as per direction of Engr-in-Charge). |
| 20 | Demolition (ordered in part demolition) to brickwork or stone/boulder masonry, but built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 21 | M&L for brick work with flyash bricks straight or curved on plan exc 6 m mean raidus built in old size bricks cm 1:4 complete all as specified and directed. |
| 22 | Taking down cement or cement lime plaster, any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 23 | M&L for rendering 15 mm thick in CM 1:4 in two layers, 5mm thick in CM (1:4) over a coat of 10mm thick in CM (1:4) when surface of green and finishing with and including mixing of liquid WPC of approved make @ 200ml per bag of cement/manufacturer\"s instructions on brick/concrete wall surfaces of any description, and finishing the surfaces even and fair complete all as specified and directed. |
| 24 | M&L for preparing surfaces newly plastered or unplastered surfaces of walls and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces complete all as specified and directed. |
| 25 | M&L for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces wwith and including complete removal of existing treatment of any layer of wall and preparing complete all as specified and directed. |
| 26 | Demolition of stone slab/tiles of any description or thickness laid, bedded and pointed in cement mortar/in floor, skirting, hard standing, Apron etc complete all as specified and directed. |
| 27 | M&L for 18-20mm thick granite (of any type and shade of Z Black ) work table rubbed and pre polished as used in dado and vertical suface of pillar and post of gate and similar work in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixtures of pigment to match with shade of granite with including 15mm thick backing coat in CM (1:4) including triangular filleting in CM 1:6 on top of tiles and ensure best adhesion to surface complete all as specified and directed. |
| 28 | S&F galvanised 600mm dia concertina coil with mechanically crimped punched blades include the core wire diameter and material (e.g. 2.5mm or 3.5mm high carbon steel), the punched tape width (e.g. 19mm) and blade spacing (e.g. 35mm) etc having approx 50 nos rounds per 6 metre length for security fencing complete all as specified and directed. |