| 1 | M & L cement concrete (1:2:4)type B-0 using 12.5mm graded stone aggregate as in kerbs or mud stops, rounded or chamfered on edges and similar work etc. including cleaning and removing all dust from existing roof surface before placing of concrete all as specified and directed by Engineer - in - Charge. |
| 2 | Supply only liquid integral water proofing compound, complete all as specified. |
| 3 | M & L for 75mm thick cement concrete type D-2 (1:4:8) using 40mm graded stone aggregate as in sub floors, sub bases etc all as specified and directed by Engineer - in - Charge. |
| 4 | M & L 15mm thick rendering in Cement Mortar 1:3 to roof surfaces, bearing plaster, sunken portion etc. finished even and smooth without using extra cement complete all as specified and directed by Engineer - in - Charge. Note:- The rates do not include for the supply of integral water proofing compound, which shall be paid for in addition at “supplied only rates separately, as applicable. |
| 5 | M & L applying evenly a tack coat of industrial bituman 85/25 @ 1.2 Kg / Sqm on plaster surface including cleaning of surfaces all as specified and directed by Engineer – in – Charge |
| 6 | M&L for APP based polymeric membrane minimum weight 3kg per sqm and minimum 3mm thick reinforced with polyster non woven fabric (weight not less than 150 gm per Sqm) laid over primed surface by force application and APP membrane shall be covered with bituminious based aluminium paint @ 0.2 Kg per Sqm in two coats complete all as specified and directed. |
| 7 | M & L for Cement concrete tiles 25cm x 25cm x 22mm thick, with grey cement and no pigment, machine pressed;set, jointed and pointed in neat cement slurry in floors,cut and polished as in floors over and including 15mm thick screed bed of cement mortar 1:4 complete all as specified and directed by Engineer - in - Charge . |
| 8 | M & L for chequered cement concrete designer prepolished glossy finished tiles 20cm x 20cm x 25mm thick with grey cement and pigments set, heavy duty, jointed and pointed in neat cement slurry and pigments as in floors over and including 15mm thick screed bed of cement mortar 1:4 complete all as specified and directed by Engineer - in – Charge. |
| 9 | Demolition of brick work built in cement mortarall as specified and directed by Engineer - in - Charge. |
| 10 | M&L Brick work with sub class \"B\" old size burnt bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 all as specified and directed by Engineer - in - Charge . |
| 11 | S & F mild steel as in stairs (framed) including stringers, treads, landing, balusters, hand rails etc.including cleats, brackets etc. complete of and similar work conforming to Fe 410-W (Gde E- 250 ), quality-A,all as specified and directed by Engineer - in - Charge. |
| 12 | M & L providing two coats of synthetic enamel paint over a coat ofred oxide primer on new steel surfaces including preparation of surface of any description over 10 cm width or girth all as specified and directed by Engineer - in - Charge . |
| 13 | M & L rendering 15mm thick on fair facesof brick work or concrete surfacesin CM 1:4 finished even & fair without using extra cement all as specified and directed by Engineer - in - Charge .Note:- The rates quoted by the contractor shall include welded mesh, scaffolding and necessary formwork upto G+5 storey building. |
| 14 | M & L applying two coat of cement base paint on new plastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engineer - in – Charge |
| 15 | Taking down steel tubing 15mm bore and connections including cleaning for refixing/ removal completeall as specified and directed by Engineer - in – Charge. |
| 16 | Taking down steel tubing 20mm bore and connections including cleaning for refixing/ removal completeall as specified and directed by Engineer - in – Charge. |
| 17 | S & F 15mm bore medium grade steel tubes galvanised with all fittings and fixed complete to walls & ceiling or laid in floor all as specified and directed by Engineer - in – Charge . |
| 18 | S & F 20mm bore medium grade steel tubes galvanised with all fittings and fixed complete to walls & ceiling or laid in floor all as specified and directed by Engineer - in – Charge . |
| 19 | S & F as in repairs ball brass valve 20mm bore dia high pressure with polythene float and fly nuts complete screwed with iron pipe and fixed all as specified and directed by Engineer - in - Charge . |
| 20 | S&F PVC (SWR), single socketed, 110mm dia bore in any length withrubber ring joints, fixed to walls complete all as specified and directed |
| 21 | S&F PVC (SWR) bends any radius bore of 75 mm with access doorall as specified and directed by Engineer - in - Charge |
| 22 | S&F PVC (SWR) bends any radius bore of 110 mm with access doorall as specified and directed by Engineer - in - Charge |
| 23 | S & F PVC (SWR) 110 mm bore Tee complete all as specified and as directed. |
| 24 | S & F PVC (SWR) 75 mm bore Tee complete all as specified and as directed. |
| 25 | S&F PVC (SWR) 110mm bore elbow all as specified and directed by Engineer - in - Charge |
| 26 | S&F PVC (SWR) 75mm bore elbow all as specified and directed by Engineer - in - Charge |
| 27 | S & F PVC (SWR) 150 x 110 mm Tee reducer complete all as specified and as directed. |
| 28 | S & F PVC (SWR) 100 x 75 mm Tee reducer complete all as specified and as directed. |
| 29 | S & F as in repairs rotational moulded polythene water storage tanks, white colour (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I of capacity 1000 Litres all as specified and directed by Engineer - in - Charge . |
| 30 | Disconnecting existing tanks, exceeding 500 litres and not exceeding 1000 litres capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position all as specified and directed by Engineer - in - Charge. |
| 31 | Factory made SFRC Pre-cast RCC manholes covers EHD-35 of size 300mm X 300mm X 100 mm thick, conforming to IS-12592 duly fixed on manhole /gully trap opening complete all as specified. |
| 32 | Factory made SFRC Pre-cast RCC manholes covers EHD-35 of size 450mm X 450mm X 100 mm thick, conforming to IS-12592 duly fixed on manhole /gully trap opening complete all as specified. |
| 33 | Factory made SFRC Pre-cast RCC manholes covers EHD-35 of size 600mm X 600mm X 100 mm thick, conforming to IS-12592 duly fixed on manhole /gully trap opening complete all as specified. |
| 34 | Factory made SFRC Pre-cast RCC manholes covers EHD-35 of size 900mm X 450mm X 100 mm thick, conforming to IS-12592 duly fixed on manhole /gully trap opening complete all as specified. |
| 35 | Dismantling wrought iron or mild steel work of any description all as specified and directed by Engineer - in - Charge . |
| 36 | Taking down cement plaster/ terrazo finish on brick wall including racking out joints, hacking for keys scrubbing down with water all as specified and directed by Engineer - in - Charge. |
| 37 | Demolition and breaking upto 100mm bore drain pipes (salt glazed ware or AC pipe set) in cement mortar and taking out from walls all as specified and directed by Engineer - in – Charge. |
| 38 | Demolition of cement concrete (un-reinforced) in floors / pavings, (below or above ground level) and of any description and in any position not otherwise specifically provided for all as specified and directed by Engineer - in - Charge . |
| 39 | Dismantling brick tiles or terracing tiles, single layer on roofs all as specified and directed by Engineer - in - Charge. |
| 40 | Demolition of mud in roof, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) all as specified and directed by Engineer - in - Charge. |