| 1 | Supply only liquid water proofing compound, as approved, complete all as specified & directed. |
| 2 | M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends complete all as specified and directed. |
| 3 | Excavating in trenches, not exceeding 1.5 mtr wide and not exceeding deep for foundation but additional or part thereof in depth and wide beyond the first 1.5 m and getting out in soft/loose soil complete all as specified & directed. |
| 4 | M&L for cement concrete in foundation filling and mass concrete type D2 1:4:8 (40 mm graded stone aggregate) complete all as specfied & directed. |
| 5 | M&L brickwork with subclass \"B\" bricks, straight or curved on plan exceeding 6m mean radius built in CM 1:4 complete all as specfied & directed. |
| 6 | M & L for Precast Cement Concrete 1:2:4 type B1 (20 mm graded aggregate) in lintels upto 1.5 m clear span, cills, steps, seismic and other similar gands, plinth courses, string courses, facing courses, parapets and railing upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed. |
| 7 | M&L Rendering 15 mm cement mortar (1:4) & finished the surface even and smooth without using extra cement complete all as specified and as directed. |
| 8 | M&L for preparing surfaces plastered or unplastered new surfaces with one coat of alkali resistant primer and two coats of cement base paint complete all as specified and directed. |
| 9 | M&L for Mild steel angle, flat work as in posts and struts in fencing including cutting tops to shape as directed, drillingholes, notching for wireetc, flat rion fillets (for securing wiremesh etc) including all necessary drilling, bolting or riveting etc conforming to FE 290-gde E-165 complete all as specified & as directed. |
| 10 | M&L Preparation of steel surfaces of any description over 10 cm in width or girth not otherwise described and two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 11 | S&Ffor galvanised 2 strandsteel barbed wire 2.24mm diabarbed with 2mm dia barbs at 75mm spacingsand straining and fixingto any type of standard railsstraining bolts, including securingor tyingat crossing with and provision of galvanised mild steel wire, staples or steel pins etc complete all as specified & directed Note : Each line wire to be measured. |
| 12 | Returning, filling in, including spreading, levelling & watering & well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified & directed |
| 13 | Removing excavated material not exceeding 50 m & depositing where directed at a level not exceeding 1.5 m above the starting point in soil complete all as specified & directed |
| 14 | M&L for RCC M-25 Design Mix using 20mm graded aggregate in fundamental incl rafts, footings fundamental beams plinth beams bases for columns etc basement slabs, under-reamed piles and mass concrete complete all as specified & directed |
| 15 | M&L for RCC M-25 Design Mix using 20 mm graded aggregate in columns, pillars, piers, posts and struts etc complete all as specified and directed. |
| 16 | Formwork to sides of flat concrete foundations, footings, bases of column fair finished surface of concrete complete all as specified & directed |
| 17 | Formwork to sides of piller, column fair finished surface of concrete complete all as specified & directed |
| 18 | M & L for MS Bar 10mm dia and over cut to length bent to shape requiredincluding cranking , bending bindingspirally for hooping forcolomns hooking ends and binding with andincluding mild steel wire (annealed) not less than 0.9mm dia, TMT Bar complete all as specified & directed |
| 19 | M&Lfor mild steel bars 8 mm diaand over upto 10mm dia in stirrups and binders etc including cutting, bindingbending, hooking ends and binding withand including mild steel wire (annealed) not less than 0.9mm dia quality conforming to TMT Bars complete all as specified & directed |
| 20 | M & L for framed work as in steel gate incl drilled for fixing of steel sheeting and to be prepared for hanging or sliding incl either hooks or hinges exclusive of steel sheeting complete all as specified & directed |
| 21 | M&L for 20 mm thick Granite work in steps jambs pillars window cills cooking platforms and like in cement mortar 1:4 incl pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite complete all as specified & directed |
| 22 | M & L for preparation of new or previously untreatedsteel surface and applying two coats of synthetic enamel paint over a coat of red oxide of surfaces exceeding 10cm width or girth complete all as specified & directed |
| 23 | Supply and fixing ,testing A Grade acrylic 3D letters onACP sheet ,each Letter size/height 0.45mtr(18 inch) including 2 Nos of Logos (design and colour approved by Engr-in-charge) with Samsung LED stip light(module type) including FRLSH copper cable 1.50 Sqmm to electric supply as per requirement with 5 Amp switch socket & includinginstallation etc complete all as specified & directed(Note:-Drawings and Specifications are held this office pl) |
| 24 | Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ.(ii) Make of material shall be as per mentioned in Particular specifications or Appendix \"B\" to Particular specifications as approved by AGE (I) AF manauri |