Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | SCHEDULE \"A\" B/R |
| 2 | Demolition of cement concrete in any position and any description not otherwise specifically provided, complete all as specified and directed by Engineer-in-Charge.Note: The rate includes disposal off Unserviceable items/debris/spoil obtained from demolition, breaking & dismantling by the contractor outside MoD defence land as directed. |
| 3 | Material & Labour for 40mm thick Plain cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in flooring/ correction layer, complete all as specified and directed by Engr-in-Charge. |
| 4 | Material & Labour for 25mm thick sand layer watering and ramming, complete all as specified and directed by Engineer-in-Charge. |
| 5 | Material & Labour for dismantling and re-fixing of machine pressed precast concrete interlocking reflective coloured pavers block any shape and size confirming, complete all as specified and directed by Engineer-in-Charge. |
| 6 | Taking down cement plaster on brick/stone surface of wall built in cement mortar including racking out joints, hacking for key, scrubbing down with water etc., complete all as specified and directed by Engineer-in-Charge.Note: The rate includes disposal off Unserviceable items/debris/ spoil obtained from demolition, breaking & dismantling by the contractor outside MoD defence land as directed. |
| 7 | Material & Labour for 10mm thick rendering on fair faces of stone work or concrete surfaces in Cement Mortar 1:6, finished even and smooth w/o using extra cement, complete all as specified and directed by Engineer-in-Charge. |
| 8 | Material & Labour for 15mm thick rendering on fair faces of stone work or concrete surfaces in Cement Mortar 1:4, finished even and smooth w/o using extra cement, complete all as specified and directed by Engineer-in-Charge. |
| 9 | Material & Labour for preparation of new plastered surfaces of wall and applying two coats of OBD over a coat of wall putty, complete all as specified and directed by Engineer-in-Charge. |
| 10 | Material & Labour for preparation of new plastered surfaces of wall and applying two coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/ltrs and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm all as per the manufacturer’s instructions, complete all as specified and directed by Engineer-in-Charge. |
| 11 | Material & Labour for preparation of old plastered surfaces and applying one coat of white wash on ceiling, complete all as specified and directed by Engineer-in-Charge. |
| 12 | Material & Labour for preparation of old plastered surfaces and applying one coat of oil bound distemper on internal walls, complete all as specified and directed by Engineer-in-Charge. |
| 13 | Material & Labour for preparation of old plastered surfaces of wall and applying two coats of OBD over a coat of wall putty, complete all as specified and directed by Engineer-in-Charge. |
| 14 | Material & Labour for preparation of old plastered surfaces of ceiling and applying one coats of OBD, complete all as specified and directed by Engineer-in-Charge. |
| 15 | Material & Labour for preparation of old plastered surfaces and applying one coat of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance, Alkali & fungal resistance, dirt resistance of required shade on wall surfaces, complete all as specified and directed by Engineer-in-Charge. |
| 16 | Material & Labour for preparation of old plastered surfaces and applying two coat of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance, Alkali & fungal resistance, dirt resistance of required shade on wall surfaces, complete all as specified and directed by Engineer-in-Charge. |
| 17 | Material & Labour for preparation of old wooden surfaces over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed by Engineer-in-Charge. |
| 18 | Taking down chowkhat with shutter (without taking off shutter from frames) not exceeding 1.5 Sqm, complete all as specified and directed by Engineer-in-Charge. |
| 19 | Taking down aluminium sliding window shutters of any description not exceeding 1.0 sqm each, complete all as specified and directed by Engineer-in-Charge. |
| 20 | Taking down chowkhat with shutter (without taking off shutter from frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each, complete all as specified and directed by Engineer-in-Charge. |
| 21 | Taking down shutters for any description exceeding 1.0 Sqm but not exceeding 2.0 Sqm each, complete all as specified and directed by Engineer-in-Charge. |
| 22 | Supply and fixing fibre Glass Reinforced plastic (FRP) Door Frames of cross section 90mm x 45mm having single rebate of 32mm x 15mm to receive shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fibre glass from all sides. M.S. stay shall be provided at the bottom to steady the frame, complete as specified by the manufacturer and as per directions of Engineer-in-charge. |
| 23 | Supply and fixing to existing door frames 30mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames, complete as specified by the manufacturer and as per directions of Engineer- in-charge |
| 24 | Material & Labour for Second class hard wood for chowkhat etc., complete all as specified and directed by Engineer-in-Charge. |
| 25 | Material & Labour for 40mm Flush shutters, solid core construction, with block board core and one face is covered with decorative face veneer with lipping/frame to match, complete all as specified and directed by Engineer-in-Charge. |
| 26 | Material & Labour for 35mm thick Glazed and Skelton shutters in second class hard wood, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing chamfered plain, or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhat, complete all as specified and directed by Engineer-in-Charge. |
| 27 | Material & Labour for 12mm Plywood, grade BWR, Type BB, fixed with screw to timber frame, complete all as specified and directed by Engineer-in-Charge. |
| 28 | Material & Labour for 0.9mm thick Decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer\"s instruction, complete all as specified and directed by Engineer-in-Charge. |
| 29 | Supply & Fixing in repair Continuous (piano) hinges, mild steel, bright finish or electro galvanised, complete all as specified and directed by Engineer-in-Charge. |
| 30 | Supply & Fixing 100mm Butt hinges, Extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed, type B-21, complete all as specified and directed by Engineer-in-Charge. |
| 31 | Supply & Fixing in repair 100mm Butt hinges, heavy weight, cold rolled mild steel, and fixed, type B-22, complete all as specified and directed by Engineer-in-Charge. |
| 32 | Supply & Fixing powder coated Anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc., complete all as specified and directed by Engineer-in-Charge. |
| 33 | Supply & Fixing powder coated Anodised aluminium door shutters, aluminium section weighing not less than 0.55 kg/m including 5.5mm thick tinted glass necessary joining cleats, glazing clips, rubber neoprene packing, fancy handles 2 Nos, Mortice lock 4 lever in each door, snap beading, screws, double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover governing pivot made of brass other parts made of heavy duty and fixed, complete all as specified and directed by Engineer-in-Charge. |
| 34 | Supply & Fixing powder coated aluminium anodised three track sliding window shutter and frame including jointing cleat for fixing frame/chowkhat of window as per JINDAL section code (frame 20831), shutter (20846) including glazing with 4mm thick tinted glass (02 shutters) & SS wire mesh (01 Shutter) necessary fittings, rubber packing, suitable handles, rollers for shutters and locking arrangement etc., complete all as specified and directed by Engineer-in-Charge. |
| 35 | Supply & Fixing anodised aluminium Powder coating ventilator shutters, fixed type without sash bars aluminium section weighing 0.55 Kg/m including glazing with 4mm thick tinted glass necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading screws, complete all as specified and directed by Engineer-in-Charge. |
| 36 | Supply & Fixing in repair Anodized aluminium grills of any type aluminium section of any size and fixing with necessary channels and clips, complete all as specified and directed by Engineer-in-Charge. |
| 37 | Taking up or down CPVC Pipe 20mm bore and connections including cleaning for re-fixing or removal to store, complete all as specified and directed by Engineer-in-Charge. |
| 38 | Taking up or down CPVC 25-32mm bore and connections including cleaning for re-fixing or removal to store, complete all as specified and directed by Engineer-in-Charge. |
| 39 | Taking up or down CPVC 40-50mm bore and connections including cleaning for re-fixing or removal to store, complete all as specified and directed by Engineer-in-Charge. |
| 40 | Supplying and laying of 20mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 Fitting on wall /ceiling of laying in floors, complete all as specified and directed by Engineer-in-Charge. |
| 41 | Supplying and laying of 25mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 Fitting on wall /ceiling of laying in floors, complete all as specified and directed by Engineer-in-Charge. |
| 42 | Supplying and laying of 32mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 Fitting on wall /ceiling of laying in floors, complete all as specified and directed by Engineer-in-Charge. |
| 43 | Supplying and laying of 40mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 Fitting on wall /ceiling of laying in floors, complete all as specified and directed by Engineer-in-Charge. |
| 44 | Material & Labour for CPVC Brass elbow 20mm dia., complete all as specified and directed by Engineer-in-Charge. |
| 45 | Material & Labour for CPVC Brass elbow 25mm dia., complete all as specified and directed by Engineer-in-Charge. |
| 46 | Material & Labour for CPVC Brass elbow 32mm dia., complete all as specified and directed by Engineer-in-Charge. |
| 47 | Material & Labour for CPVC Brass elbow 40mm dia., complete all as specified and directed by Engineer-in-Charge. |
| 48 | Material & Labour for CPVC Brass Tee 20mm dia., complete all as specified and directed by Engineer-in-Charge. |
| 49 | Material & Labour for CPVC Brass Tee 25mm dia., complete all as specified and directed by Engineer-in-Charge. |
| 50 | Material & Labour for CPVC Brass Tee 32mm dia., complete all as specified and directed by Engineer-in-Charge. |
| 51 | Material & Labour for CPVC Brass Tee 40mm dia., complete all as specified and directed by Engineer-in-Charge. |
| 52 | Material & Labour for CPVC Male brass threaded adopter 20mm dia., complete all as specified and directed by Engineer-in-Charge. |
| 53 | Material & Labour for CPVC Male brass threaded adopter 25mm dia., complete all as specified and directed by Engineer-in-Charge. |
| 54 | Material & Labour for CPVC Male brass threaded adopter 32mm dia., complete all as specified and directed by Engineer-in-Charge. |
| 55 | Material & Labour for CPVC Male brass threaded adopter 40mm dia., complete all as specified and directed by Engineer-in-Charge. |
| 56 | Material & Labour for CPVC Male brass threaded adopter 40mm dia., complete all as specified and directed by Engineer-in-Charge. |
| 57 | Material & Labour for CPVC Female brass threaded adopter 25mm dia., complete all as specified and directed by Engineer-in-Charge. |
| 58 | Material & Labour for CPVC Female brass threaded adopter 32mm dia., complete all as specified and directed by Engineer-in-Charge. |
| 59 | Material & Labour for CPVC Female brass threaded adopter 40mm dia., complete all as specified and directed by Engineer-in-Charge. |
| 60 | Material & Labour for CPVC Female brass threaded adopter 40mm dia., complete all as specified and directed by Engineer-in-Charge. |
| 61 | Material & Labour for CPVC Brass elbow (3/4x1/2) 20mm dia., complete all as specified and directed by Engineer-in-Charge. |
| 62 | Supply & Fixing Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) 300 mm long and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed as in repairs, complete all as specified and directed by Engineer-in-Charge. |
| 63 | Supply & Fixing in repair, 450mm long PVC connecting pipe with brass union on both ends, complete all as specified and directed by Engineer-in-Charge. |
| 64 | Supply & fixing 15mm bore pillar tap long neck, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"hot\" or \"cold\" with long screwed shanks and fly nuts, screwed for iron pipe, fixed as in repair, complete all as specified and directed by Engineer-in-Charge. |
| 65 | Supply & Fixing in repairs, 15mm bore stop valves (concealed type), chromium plated cast copper alloy, screwed down, high pressure, fancy type, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed by Engineer-in-Charge. |
| 66 | Supply & Fixing in repairs, 600mm x 450mm bevelled edge looking mirror of selected quality glass of any size as directed, mounted on 6mm thick AC building board or commercial ply wood and fixed to wooden plugs with chromium plated, brass screws and cup washers, complete all as specified and directed by Engineer-in-Charge. |
| 67 | Supply & Fixing in repairs, Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed by Engineer-in-Charge. |
| 68 | Supply & Fixing in repairs PVC (SWR) floor trap of 75mm outlet dia, plain with grating including jointing with solvent cement, complete all as specified and directed by Engineer-in-Charge. |
| 69 | Material & Labour for 20mm Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms, vertical partition, skirting and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, as in repair, complete all as specified and directed by Engineer-in-Charge. |
| 70 | Supply & Fixing in repair, Health faucet (ABS body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position, complete all as specified and directed by Engineer-in-Charge. |
| 71 | Supply & Fixing in repair, Vitreous China wash hand basin, white, Counter top oval shape any size as approved including cutting for and pinning in ends of brackets or erecting stand including 300mm long waste pipe, complete all as specified and directed by Engineer-in-Charge. |
| 72 | Supply & Fixing for Brass chromium plated 32mmm dia bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed as in repair, complete all as specified and directed by Engineer-in-Charge. |
| 73 | SCHEDULE \"A\" E/M |
| 74 | Taking down carefully burnt out aluminium/copper point wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendent, regulators, sockets, fluorescent tube light fittings etc., to be measured and paid for separately) removing materials to store for schedule of credit and making good to the disturbed surfaces of walls ceilings and floors etc., complete all as specified and directed by Engineer-in-Charge. |
| 75 | Disconnecting of unserviceable sub main wiring of any size and including steel conduit and accessories & removing from site and making good the disturbed surfaces including painting, complete all as specified and directed by Engineer-in-Charge. |
| 76 | Material & Labour for point wiring using ISI marked 1.1 kV grade single core FR-LSH flexible cable, conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors in existing conduit/ Provision of PVC cassing capping as per site requirement sizeconforming to IS: 8130- 1984 and insulation conforming to IS: 5831- 1984, for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25mm size PVC medium grade surface/recessed cassing capping, modular cover-plates and framecomplete all as specified in IS: 732- 1989 and directed. NOTE: Circuit wire from DB to switch boards shall be included in quoted rate. Note (i) Existing Modular sheet metal box should not be removed (ii) Mounting plate and cover plate of existing size is to be replace and rate are deemed to be included in quoted rate.(iii) PVC cassing capping measured and paid under relevant Item. |
| 77 | One light / Bulb Holder / fan / exhaust point / bell point controlled by one, one way switch |
| 78 | One light point controlled by 2, Two way switch |
| 79 | One 5 pin socket outlet 5/6 amps on the same board. |
| 80 | One 5 pin socket outlet 5/6 amps on independent board.. |
| 81 | Material & Labour for point wiring using ISI marked 1.1 kV grade single core FR-LSH flexible cable, conforming to IS: 694- 1990, having multi drawn thin strands of electrolytic copper conductors, conforming to IS: 8130- 1984 and insulation conforming to IS: 5831- 1984, for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25mm size PVC medium grade surface/recessed cassing capping conforming to IS: 537 (Part 3)- 1983, colour-coded as specified in IS: 11353- 1985, and including modular cover plates complete all as specified in IS: 732- 1989 and directed.Note:- (i) Existing Modular sheet metal box should not be removed (ii) Mounting plate and cover plate of existing size is to be replace and rate are deemed to be included in quoted rate. |
| 82 | One 16 A socket outlet, independent, with cables 2.5 mm² size |
| 83 | Supply & Fixing in replacement of modular type 6 Amp one-way SP switch, conforming to IS: 3854-1997 with finger proof terminal, complete all as specified and directed by Engineer-in-Charge. |
| 84 | Supply & Fixing in replacement of modular type 16 Amp one-way SP switch, conforming to IS: 3854- 1997 with finger proof terminal, complete all as specified and directed by Engineer-in-Charge. |
| 85 | Supply & Fixing in replacement of modular type 2/3 pin combined shuttered type 6 Amp socket conforming to IS: 1293- 2005, complete all as specified and directed by Engineer-in-Charge. |
| 86 | Supply & Fixing in replacement of modular type 2/3 pin combined shuttered type 6/16 Amp socket conforming to IS: 1293- 2005, complete all as specified and directed by Engineer-in-Charge. |
| 87 | Supply & Fixing in replacement of modular type 6 Amp bell-push conforming to IS: 8884-1978 with finger proof terminal, complete all as specified and directed by Engineer-in-Charge. |
| 88 | Supply & Fixing in replacement of Bell multi music type 230 Volt, complete all as specified and directed by Engineer-in-Charge. |
| 89 | Supply & Fixing in replacement of modular type 120 W step fan regulator of 2 module size, conforming to IS: 11037-1984, complete all as specified and directed by Engineer-in-Charge. |
| 90 | Supply & Fixing in replacement of 6 Amp, 250 V high quality robust surface/flush type polycarbonate / PVC ceiling rose, conforming to IS: 371-1979, having 2/3 terminals and outside diameter not less than 63.5mm, complete all as specified and directed by Engineer-in-Charge. |
| 91 | Supply & Fixing in replacement of Modular switch 2 way 6 Amp, 1 module, complete all as specified and directed by Engineer-in-Charge. |
| 92 | Supply and fixing in replacement of Modular Flush box, complete all as specified and directed by Engineer-in-Charge. of following size:- |
| 93 | 1 or 2 Module Metal flush box |
| 94 | 3 Module Metal flush box |
| 95 | 4 Module Metal flush box |
| 96 | 6 Module Metal flush box |
| 97 | Supply and fixing in replacement of Modular cover plate with frame, complete all as specified and directed by Engineer-in-Charge. Of following size:- |
| 98 | 1 or 2 ModuleModular cover plate with frame of size 85mm x 85mm |
| 99 | 3 Module Modular cover plate with frame of size 85mm x 115mm |
| 100 | 4 Module Modular cover plate with frame of size 85mm x 145mm |
| 101 | 6 Module Modular cover plate with frame of size 132mm x 135mm |
| 102 | Supply & Fixing Lamp holder plug for Batten fitting, complete all as specified and directed by Engineer-in-Charge. |
| 103 | Supply & Fixing 2.5/4 mfd Capacitor, complete all as specified and directed by Engineer-in-Charge. |
| 104 | Supply & Fixing Top plug 5 Amp, complete all as specified and directed by Engineer-in-Charge. |
| 105 | Supply & Fixing Top plug 15 Amp, complete all as specified and directed by Engineer-in-Charge. |
| 106 | Supply & Fixing in replacement of MCB DB sheet enclosure double door type, single pole and neutral 240 V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 12 way type, complete all as specified and directed by Engineer-in-Charge. |
| 107 | Supply & Fixing in replacement of MCB DB sheet enclosure double door type, single pole and neutral 240 V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 4 way type, complete all as specified and directed by Engineer-in-Charge. |
| 108 | Supply & Fixing in replacement of MCB DB sheet enclosure double door type, triple pole and neutral 415V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 4 way type, complete all as specified and directed by Engineer-in-Charge. |
| 109 | Material & Labour for sub main wiring using ISI marked 1.1 kV grade single core FRLS flexible cable, conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831- 1984, type C, HR 85° C + FR for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25mm size in existing conduits / PVC Cassing capping surface/recessed conforming to IS: 9537 Part- 3, colour-coded as specified in IS: 732- 1989, including making good of disturbed surfaces of wall/ceiling/floor with painting, complete all as specified and directed by Engineer-in-Charge. NOTE: 01 run of phase conductor, 01 run of neutral conductor, 01 run of earth continuity conductor and 01 run of PVC Cassing capping shall be measured as one length. |
| 110 | 2 x 6.0 Sqmm + 1 x 6.0 Sqmm earth wire |
| 111 | 2 x 4.0 Sqmm + 1 x 4.0 Sqmm earth wire |
| 112 | 2x 2.5 Sqmm + 1 x 2.5 Sqmm earth wire |
| 113 | Supply and fixing in replacement ofamp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and directed by Engineer-in-Charge. |
| 114 | MCB 6 to 32Amps, single pole |
| 115 | MCB 32Amps, double Pole / SPN |
| 116 | MCB 40 to 63Amps, double Pole / SPN |
| 117 | Supply and fixing in replacement of 415V 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning, complete all as specified and directed by Engineer-in-Charge. |
| 118 | MCB, TP 25 to 63 Amps |
| 119 | MCB, TPN/FP 16 to 32 Amps |
| 120 | Supply and fixing in replacement of casing capping of 25x 12 mm size, complete all as specified and directed by Engineer-in-Charge. |
| 121 | Supply and fixing in replacement of casing capping of 32x16 mm size, complete all as specified and directed by Engineer-in-Charge. |
| 122 | Taking down ceiling fan 1200mm/1400mm sweep and Exhaust fan upto 250mm sweep complete servicing, painting, repair of fan motor and replacement of worn out parts such as bearing and hanging of ceiling fan/Exhaust fan in situ, complete all as specified and directed by Engineer-in-Charge. Note: (i) Rewinding of fan motor will be measured and paid separately. |
| 123 | Dismantling of fan (1200mm sweep) motor, cutting of burnt winding of rotor and rewinding with same gauge copper wire winding with insulated material and reassembling, complete all as specified and directed by Engineer-in-Charge. |
| 124 | Dismantling of Exhaust fan 250/300mm sweep motor, cutting of burnt winding of rotor and rewinding with same gauge copper winding wire with insulated material and reassembling, complete all as specified and directed by Engineer-in-Charge. |
| 125 | Dismantling of Exhaust fan Plastic Body 250/300mm motor, and replace with new motor and reassembling, complete all as specified and directed by Engineer-in-Charge. |
| 126 | Supply & Fixing in repair of wall mounted LED Tube light fitting 1 x 10W LED (6500K), 2 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting, complete all as specified and directed by Engineer-in-Charge. |
| 127 | Supply & Fixing in repair of wall mounted LED Tube light fitting 1 x 20W LED (6500K), 4 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting, complete all as specified and directed by Engineer-in-Charge. |
| 128 | Supply & Fixing in replacement of LED Luminaires recessed mounted down lighter 18 watt 5700K system efficiency not less than 100lm/watt, thd<10% single phase including connecting cable from ceiling rose to terminal block of luminaires, complete all as specified and directed by Engineer-in-Charge. |
| 129 | Supply & Fixing in replacement of square shape slim recessed mounted LED down light of capacity 36 Watt (2ft x 2ft)with die cast housing finished in white powder coating, complete all as specified and directed by Engineer-in-Charge. |
| 130 | Supply and Fixing of Single Phase Two Wire Direct connected Meter Type SARAL, 230/240 V (L-N), Rating 5-30 A, CL.1, 50 Hz ± 5%, IP 54, Protective class II, with Advanced anti-tamper capability– prevention, detection and deterrence, complete with protection cover Meter must comply following points :Standards IS 13779, IEC 62052-11, IEC 62053-21, IS 15959, DLMS Indian Companion Standard Dimensions (W x H x D) 95 x 130 x 60mm (approx.) Data storage :Midnight energy 35 days for 2 parameters Load survey More than 150 days (30min. IP) upto 5 parameters, Events Up to 300 events, compartment wise History 12 billing periods.Communication: IEC 62056-21 physical port for local communication, Optional RS 232 port over micro USB for remote communication. Note: Rates are inclusive of polycarbonate Protection cover. Make: Secure/HPL/Elmeasure |
| 131 | Supply & Fixing in repair wall/surface mounted LED Bulk head of capacity 10 Watt IP 65 Protection, complete all as specified and directed by Engineer-in-Charge. Make: Wipro Cat No:LW07-141-XXX-57-G1 or in Philips or equivalent make mentioned in Appendix \"B\". |
| 132 | Material and labour for maintenance of solar water heating system flat plate type including all water and electric connections of capcity 100 Ltrs per day and re-fixing the same in existing position after the following repairs and testingcomplete :- Location : ICGE Pipavav (a) Replacement of the worn out/missing nuts bolts, washers, unions, sockets flanges and screw etc complete.(b) Descaling/desludging the hot water pipes and normal water by using appropriate chemicals/Anti corrosive/Anti scaling agent solution, cleaningand washing all copper tube & water circulated pipes of heat convector sets thoroughly cleaning the complete solar pannel of making the tube scale free andre-assembling the pannel.(c) Cleaning hot and cold water tanks, removing sludge and scale from the tank manually using suitable chemicals complete.(d) Repair of collector fins including required welding works etc complete.(e) Testing on completion after Repair work and making the Solar Water Heater functional in each aspect.(Note : Cost of dismantling and re-fixing and minor repairs deemed to be included in quoted rate. |
| 133 | All as per item No. 110 here in before but of capacity 200 ltrs per day, complete all as specified and directed by Engineer-in-Charge. |
| 134 | Material and Labour for painting the MS supporting structure of solar water heating system completeas per original shade with two coats of synthetic enamel paint over one coat of primer by spray gun after scrapping the existing paint, denting, filling depression with putty etc., complete all as specified and directed by Engineer-in-Charge. |
| 135 | Supply & Fixing building securityLED Light fitting 35 watt, system efficiency not less than 100 lumen / watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting including taking down old light fitting of any description, complete all as specified and directed by Engineer-in-Charge. Make :- Wipro, Cat part No LR02-291-XXX-57-XX or in Philips or equivalent make mentioned in Appendix \"B\". |
| 136 | Supply only solar panel water heater element 2/3 KW with thermostat cut off electric water geyser temperature controlling sensor suitable for 230 V ac, complete all as specified and directed by Engineer-in-Charge. |
| 137 | Material & Labour for annual servicing of Split Air conditioner cap 1.5/2.0 ton by disconnecting electric connection from its stabilizer or its electric board and remove the front cover or indoor AC unit and cleaning it with pressurized water and nylon brush, re-fixing the front cover of indoor unit .Remove the outer cover of outdoor unit and covered the condensing unit with ploythene/plastic cover so that water shall not be entered in the motor while cleaning the unit and filter with pressurized water then apply one coat of descaling solution and clean with wire mesh bursh /nylon brush to the condensing coil of outdoor unit and greasing of all moving parts. Cleaning of Cooling and condenser coil of indoor and outdoor unit shall be properly carried out without damaging other parts. Checking and making serviceable electrical connection of DBs, Stabilizer, wiring of ACs as per site condition and tightening all electrical connection, complete all as specified and directed by Engineer-in-Charge.Note- Replacement ofdefective parts with new parts shall be measured and paid separately under respective items in the schedule. |
| 138 | Material & Labour for detecting the cause of leakage in any type/capacity of 1.5/2ton inverter / non inverter AC and ensuring the complete system leak proof and charging of refrigerant gas with appropriate quantity including testing for smooth functioning, complete all as specified and directed by Engineer-in-Charge. Notes :-(i) Dismantling of unserviceable compressor, cost of refrigerant gas and re-installation of serviceable compressor after repairing are deemed to be included in the quoted rates. |
| 139 | Material and labour for maintenance of air conditioner 1.5/2.0 ton capacity, Split type unit with replacement of old/unserviceable spare parts mentioned as under or as per manufacturer instructions including testing on load, complete all as specified and directed by Engineer-in-Charge. |
| 140 | Supply & Fixing in repair Running capacitor of 36/45/50/60 + 5/6 mfd suitable for 240 volts 50 HZ AC Supply. |
| 141 | Supply & Fixing in repair capacitor of 2.5 mfd suitable for blower fan motor of 1.5/2.0 ton AC. |
| 142 | Supply & Fixing in repair thermostat switch of suitable for 1.5/2.0 ton AC |
| 143 | Supply & Fixing in repairs Pre-air filter made up of PVC for indoor unit of split AC suitable for any make and description complete |
| 144 | Supply & Fixing in repairs PVC fan blower assembly for 1.5 /2TR split AC\"s any make |
| 145 | Supply & Fixing in repairs Printed circuit board(PCB) with suitable for non-inverter type Split AC1.5/2.0 TR of any capacity, model and make as per existing complete with necessary electrical connection. |
| 146 | Material & Labour for replacement of defective cut open compressor/Uncut compressor suitable for air conditioner with new compressor filled with capila D and charging of refrigerant gas up to required capacity after flushing the complete refrigerant system including repair to leakage if any in refrigerant piping and replacement of filter complete for split type AC\"s of the following capacity complete all as specified and directed by Engr-in-charge. |
| 147 | 1.5 ton capacity |
| 148 | 2.0 ton capacity |
| 149 | Supply & Fixing in repairs Condenser Fan motor for outdoor unit suitable for inverter type split AC 1.5/2.0 TR of existing make, complete all as specified and directed by Engineer-in-Charge. |
| 150 | Supply & Fixing in repairs Blower motor for indoor unit suitable for inverter type split AC 1.5/2.0 TR of existing make, complete all as specified and directed by Engineer-in-Charge. |
| 151 | Supply & Fixing in replacement of Printed circuit board(PCB) with hand set of indoor, outdoor and display unit suitable for Inverter type Split AC 1.5/2.0 TR of any capacity, model and make as per existing complete with necessary electrical connection, complete all as specified and directed by Engineer-in-Charge. |
| 152 | Material & Labour for replacement of outdoor condenser unit of copper with 2 run of copper pipe of outdoor unit of split type AC 1.5/2.0 TR, complete all as specified and directed by Engineer-in-Charge. . |
| 153 | Material & Labour for replacement of swing motor 230 Volt for 1.5/2.0 Ton indoor unit of split ac, complete all as specified and directed by Engineer-in-Charge. |
| 154 | Supply & Fixing in repairs Blade set of fan motor of outdoor unit, made out of Aluminium sheet Suitable for shaft bore dia 1/2\" and fan dia 16\"/ 18\" in existing air conditioner split type, complete all as specified and directed by Engineer-in-Charge. |
| 155 | Supply & Fixing in repairs Blade set of fan motor of outdoor unit, made out of PVC Suitable for shaft bore dia 1/2\" and fan dia 16\"/ 18\" in existing air conditioner split type, complete all as specified and directed by Engineer-in-Charge. |
| 156 | Supply & Fixing in repairs copper tubing of size 3/8\" suitable for split AC with nitrile self-adhesive foam wrapped with PVC insulation all around the pipe line, complete all as specified and directed by Engineer-in-Charge. |
| 157 | Supply & Fixing in repairs copper tubing of size 5/8\" suitable for split AC with nitrile self-adhesive foam wrapped with PVC insulation all around the pipe line, complete all as specified and directed by Engineer-in-Charge. |
| 158 | Supply and fix in repair flexible PVC pipe for condense water outlet for Split AC as per existing, complete all as specified and directed by Engineer-in-Charge. |
| 159 | Material & Labour for charging of refrigerant R-410/R-22/R-32 gas to air conditioner or as per existing /manufacturer instructions suitable for split air conditioner cap 1.5 ton after flushing out the entire refrigerant, vacuum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas, as per manufacturer instructions, as mentioned above, complete all as specified and directed by Engineer-in-Charge. |
| 160 | All as per item no.129 above but for 2.0 ton capacity complete as per manufacturer instructions complete all as specified and directed by Engineer-in-Charge. |
| 161 | Material and labour for servicing/cleaning of water cooler of storage capacity/ nominal cooling capacity(Ltrs/hr) 80/40 & 120/60 litres with the use of ant scaling agent for internal steel water tank , outer body and condenser coil of water cooler, Removal of dust and other deposited material for the various functional equipment using smooth nylon brush ,cleaning of drainage for speedy water removal and checking of electrical connection to compressor and other electrically operated equipment’s, cleaning of fins and tubes of condenser, repair/replacement of PUF thermal insulation, checking of refrigerant leakage and functionality of water tap, complete all as specified and directed by Engineer-in-Charge. |
| 162 | Supply and fixing hermetically sealed compressor of water cooler of capacity 40 ltr/hr suitable for R134a gas, single phase alongwith capacitor and relay, including gas charging in the system and testing of water cooler, complete all as specified and directed by Engineer-in-Charge. Make : Copeland/Tecumseh.Note : Cost of cutting of existing worn out compressor will be deemed to be included in unit rate. |
| 163 | Taking out burnt unserviceable condenser fan motor, and replacement with new electric motor, single phase 230V of water cooler 40ltrs/hrs with condenser fan blade, complete all as specified and directed by Engineer-in-Charge. |
| 164 | Supply and fixing in replacement of of following items of water cooler |
| 165 | Thermostat for water cooler capacity 40/80 ltr/hrs. |
| 166 | Push type Bib tap Cast copper alloy 15mm Push type chromium plated. |
| 167 | PVC Connection with brass unions at both ends with brass nuts, suitable for fixing to 15mm dia GI Pipe. |
| 168 | Material and labour for carrying out repair /maintenance/ servicing of Refrigerator of any capacity by periodic cleaning of internal and external parts, cleaning of water collection area and checking of electrical circuit repair/ replacement of unserviceable/worn out spares and accessories to make the Refrigerator in good working condition, complete all as specified and directed by Engineer-in-Charge. Note: Defective spares required for replacement shall be measured and paid separately under respective items. |
| 169 | Material and labourfor maintenance of Refrigerator / deep freezer any capacity with replacement of old/unsv spare parts as underincluding testing on load complete all as specified and as directed by Engr-in-charge |
| 170 | Supply & Fixing in repair condenser suitable for Refrigerator of 185/ 250/ 300 ltr cap |
| 171 | Supply & Fixing in repair cooling effect transmitting fanmotor suitable for Refrigerator of 185/ 250 / 300 ltr cap |
| 172 | Supply & Fixing in repair Compressor Relay suitable for Refrigerator of 185/250 / 300 ltr cap or as per existingMake:- KCL / Rentrol / Indofos |
| 173 | Supply & Fixing in repair thermostat suitable for Refrigerator of 185/250 / 300 ltr cap |
| 174 | Supply & Fixing in repair Compressor suitable for Refrigerator of upto 300 ltr cap or as per existing |
| 175 | Material & Labour for charging of refrigerant R-134a gas to Refrigerator for the following capacities as per existing /manufacturer instructions after flushing out the entire refrigerant , vacuum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas, as per manufacturer instructions, as mentioned above, complete all as specified and directed by Engineer-in-Charge. |
| 176 | Refrigerator cap 185/310 Ltrs |
| 177 | Deployment of manpower, instrument, tools, and all connected accessories for testing of earth resistance of existing Earthing at provided earth test point for each earth set by competent calibrated digital earth test meter electronic type along with accessories (earth rod set with Cu wire with clips) and recording the result dully signed with date by MES representative and contractor, complete all as specified and directed by Engineer-in-Charge. NOTE:- (a) Testing of each Earthing shall be carried out at the interval of 3 months and measurement shall be done each time separately and test result shall be maintained dully signed with date by MES representative and contractor. (b) Pouring of water in each earth pit is deemed to be included in the rate quoted.(c) Necessary arrangement to be made by the contractor for pouring the water in earth pits.Vehicle reqd for carrying/storage of water (upto to the site) with helper will be arranged by contractor and deemed to be included in the rate quoted.(d) Cost of Maintenance of carrying vehicle (if any) and cost of fuel reqd for veh is deemed to be included in the rate quoted. |
| 178 | Material & Labour for PCC Earthing pit in PCC 1:2:4 type B-1 of internal size 300mm x 300mm x 300mm with 120mm thick wall and 700mm x 700mm x 150mm thick bed concrete and 50mm thick precast chamber cover of RCC 1:2:4, type B-1 for, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), complete all as shown in the electrical plate No 3 of SSR part –I including demolition of old pit, complete all as specified and directed by Engineer-in-Charge. |
| 179 | Supply and fixing in repair mild steel galvanised earth strip of size 25 x 4 mm with epoxy insulators and fixing screws etc for earth continuity conductors to test point terminal including taking down old strip, complete all as specified and directed by Engineer-in-Charge. |
| 180 | Material & Labour for marking of Earthing pit (GI earth / Copper earth / Chemical earth) with two or more coat synthetic enamel paint, colour & pattern as approved by the Engr-in-Charge, Letter size shall not be less than 50mm, complete all as specified and directed by Engineer-in-Charge. |
| 181 | Material & Labour for bore Earthing 150mm bore for Earthing with galvanised steel pipe electrode, 40mm bore, medium grade, 3 metres length, top edge of GI pipe not less than 1.25 metres below ground level, connected with Earthing lead of 25x4 mm GI strip to the Earthing test point and filling of charcoal dust, salt etc., and testing on completion, complete all as specified and directed by Engineer-in-Charge. Note: IR Value should be less than 5 Ohms.Note: GI earth strip of size 25 x 4 including installation 7.5 Mtr is deemed to be included in the unit rate. |
| 182 | (d) PCC Earthing pit in PCC 1:2:4 type B-1 of internal size 300mm x 300mm x 300mm with 120mm thick wall and 700mm x 700mm x 150mm thick bed concrete and 50mm thick precast chamber cover of RCC 1:2:4, type B1 for, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm),complete all as shown in the electrical plate No 3 of SSR part –I complete.(e) Contractor must visit the site before quoting the tender to understand the difficulty and cost for carrying out the job in the station. It is important that contactor ascertain the quantum of work.(f) Contractor must produce the certificate from the manufacturer that chemical Earthing has been carried out by manufacturer. The manufacturer must also mention the warranty for chemical Earthing (f) Contractor must produce the certificate from the manufacturer that chemical Earthing has been carried out by manufacturer. The manufacturer must also mention the warranty for chemical Earthing.(g) Extension strip from electrode strip up to 0.15 m height from GL to be deemed included in quoted rate including brazing(h) The Earthing result will be obtained for each electrode must be less than 3Ω.Otherwise contractor is liable to do chemical Earthing to meet the result.Make :- Powertrac / PRAGATI / McML\"s Earthing Solution (MES) / Ashlock |
| 183 | Note :- (i) Quoted rates shall be deemed to including boring hole up to 5 meter deep from ground level.(ii) In case additional depth of boring is required and directed by Engineer-in-Charge same shall be carried out by the contractor and will be measured & paid separately under respective of this BOQ.(iii) Additional length of copper strip (50mm x 6mm) required due to increase in depth of boring will also be measured & paid separately under respective of this BOQ.(iv) Deployment of manpower, tools / machinery etc, and all connected accessories for drilling bore of 175mm dia and depth exceeding 5 metre but not exceeding 10 metre below ground level in any kind of soil / strata including hard stone / boulder etc complete all as specified and directed by Engr -in -charge |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail