Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 24-12-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 31-12-2025 |
| Sl. No. | Item Description |
| 1 | Schedule-A (B/R Work) |
| 2 | S&F in repair anodised aluminium glazed wall partition with anodised aluminium frame of section 1.1x44x2mm including with all necessary suitable screw, rubber packing, aluminium snap beading complete all as specified and directed by Engr-in-charge. (sizes of each panel of partition - approx 0.9mx0.75m) |
| 3 | M&L for 5 mm thick aluminium composite sheet, exterior grade fixed between aluminium section wth and including snap fittings aluminium clips of polyster powdeer coated alongwith rubber gasket, complete all as specified and directed by Engr-in-Charge. |
| 4 | M&L for suspended false ceiling consisting of suitable GI sections of \"T\" angle & FI as per standard engineering practices with \"E\" board classic ceiling boards 4mm thick in grid of 0.60x1.2 mtr including cutting holes and making good holes for main joints, suspending with 4 mm dia GI wire to roof slab, roof trusses, purlins & rafters etc and all as per approved and dirtected by Engr-in-charge. |
| 5 | Dismantling ofwall/ floor tile including backing coat any description or any thickness led beded and pointed in any cement motar and removal to out of MD land.completeall as specified and as directed by Engineer-in-Charge. |
| 6 | M&L for glazed ceramic coloured tilesin vertical surface 450 x 350 x 7mm thick set in walls set and jointed in neat cementslurry over and including 15 mm thick backing coat in cement mortar (1:4) and pointed in coloured cement to match for work on vertical surface such as skirting, dado etc completeall as specified and as directed by Engineer-in-Charge. |
| 7 | M&L non skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular ) area of each tile exceedng0.11 sqm but not exceeding 0.18 sqmin floors etcset and jointed in neat cement slurry andpointed in white/coloured cement to match over and including15 mm thick screed bed in cement mortarin(1:6) completeall as specified and as directed by Engineer-in-Charge. |
| 8 | S & F vitrified tiles light shade 10mm thick (square/rectangular) polished, area of each tile n.exc. 0.36 sqm,in floor etc.,set and jointed in neat cement slurry over 15mm thick screed bed in CM 1:4 and pointed in white or coloured cement with pigment to matchfor laying floor fineshes including patch work etc all as specified by Engineer-in-Charge. |
| 9 | All as per Ser item No 07here-in-before but add to above for work on vertical surfaces such as skirtings,dados and risers to step etc over 10mm thick cement plaster in 1:4. complete all as specified and directed by Engr-in-Charge. |
| 10 | M&L for Machine cut kota stone slab flooring20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete to over & including 20 mm thic screed bed in CM 1:6 complete all as specified and directed by Engineer in Charge. |
| 11 | M&L Cement concrete 50 mm thick type C-1 (1:3:6) using 20 mm graded stone aggregate as in floor etc finished even and smooth without using extra cement completed all as specified and directed by Engineer-in-Charge. |
| 12 | Taking down door frame/ window frame with shutter of area n exc 1.50 sqm (upto 4 storey bldg), each and removing to store, complete all as specified and directed by Engr-in-Charge. |
| 13 | Taking down door frame/ window frame with shutter of area exc 1.50 but n exc 4.0 Sqm (upto 4 storey bldg), each and removing to store, complete in all respect as specified and directed by Engr-in-Charge |
| 14 | Taking down shutters only of size exc 1.00 Sqm but not exceeding 2.00 Sqm and removing to store complete all as specified and as directed by Engineer-in-Charge. |
| 15 | S&F aluminium colour powder coated door Frame and shutter single or double leaf glazed/pre laminated particle board interior panels fabricated including aluminium powder coated beading rubber Gasket and packing materials and shall be drilling in existing wall and thrust bolt suitable size with section as per TD-116/2013 sheet (2/2 to 4/4) comprising the following:complete comprising the following:- (a) Door frame section 101.60x44.45x1.93 mm fixed as per spd (b) Door Shutter Vertical Style of Size 85x44.45x2 mm as per spd. (c) Door Shutter Top style section 95.25x44.45x2.00 mm as per spd.(d) Aluminium coloured powder coated middle lock rail/bottom rail section 150x44.45x1.93mm cat No.20002.(e) Aluminium coloured powder coated Tower Bolt 02 Nos in each shutter 200 mm long as spd. (f) Aluminium coloured powder coated handle 02 Nos in each shutter 150 mm long as per spd.(g) Door Floor spring ISI Marked Make-Sandhu, Amar or equivalent.(h) Six lever mortice lock brass on in each door.(j) 12 mm thick partical board (pre laminated both face) exterior grade ISI Marked(k) Tinted glass5mm to 6mm thick. |
| 16 | S&Faluminium colouredpower coated (shade or tint as directed by GE) Side Hung window/ventilator frame and Shutter with section as per TD-109/2012 sheet (1/4 to 4/4) comprising the following:-(a) Al coloured powder coated window frame section 101.60x44.45x1.93 mm fixed as per (b) Aluminium colouredpower coated double shutter (Glass and Wire Mesh shutter) 44x44x1.50mm top/bottom/sides style. (c) Aluminium colouredpower coated butt hinges 8 Nos in each window 100 mm sizes as per spd. (d) Aluminium colouredpower coated tower bolt 3 Nos in each window 150 mm long as per spd.(e) Aluminium colouredpower coated handle 2 Nos in each window 100 mm long as per spd.(f) Tinted/coloured glass 5 mm thick fixed to window with rubber gasket & Al Powder coated beading.(g) Aluminium colouredpower coated grill make deco grill DG-104 fixed with \"H\" Section.Note : If groundrequirement for sliding window/AC windowcontractor should provide as per direction of Engineer-in-Charge without any price adjustment.including taking down complete all as specified and directed by Engr-In Charge. |
| 17 | S&FFloor door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring fixed to door shutter of size 140mm. |
| 18 | S & F Aluminium alloywire cloth 0.45mm nominal dia of wireand average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified as directed. |
| 19 | S&F door closer hydraulically regulated, (Alminium die cast body) designation No. 3, universal type, suitable for door shutters of 851 to 1000mm in width and of weightbetween 61 to 80 Kg and fixed |
| 20 | S&F in repairs Double actionfloor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloysheet foundation box,main body with stainless steel cover, governing pivot made of brass,other parts made of mild steel heavy duty and fixed make-Godrej |
| 21 | S&F 250 mm long Aluminium alloy, Anodised, sliding door bolt with hasp, staple ( bolt type) and fixing clips of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed. by Engineer-in-Charge. |
| 22 | Supply and fixing PVC insulation panels 10 mm thk with EPS stuck to 1mm plain PVC sheet Suitably placed plain PVC sheet false ceiling etc by Engineer-in-Charge. |
| 23 | Dismantling of wall and ceiling boards (Fibre, pulp, insulation etc.) or insulation board / slabs any description , anythickness incl cover fillets. by Engineer-in-Charge. |
| 24 | M&L for providing and fixing false ceiling at all heights with fully perforated 12mm thick microtegular edged or 10mm thick square edged glass fibre reinforced Gypsum false ceiling tiles ofsize 595x595mm of approved texture,designand pattern having moisture content less than 2% humidity resistance of 99% ,NRCO 0.50 to0.75 as per IS 8225:1987,Noncombustible as per BS 476(part-4)-1970 and light reflectance of 85%(minimum) to laid in true horizontal level suspendedon locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick(galvanised @120mm grams per sqm including both sides ) comprising of main T runners of size 15x32mm of length 3000mm,cross-T of size 15x32 of length 1200mm and secondary intermediate cross T of size 15x32mm of lenght 600mmto from grid module of size 600x600mm, suspended from ceiling using galvanised mild steel items(galvanised@ 80 grams per sqm)ie 50mm long,8mm outerdiameter M-6 dash fasteners,6mm dia fully threaded hanger rod upto 1000mm lenght and L shape level adjuster of size 85x25x2mm galvanised iron perimeterwall angle of size 24x24x0.40mm of length 3000mm to be fixed on periphery wall/partition with the help of plastic rawl plugs at 450mm centre to centre and 40mm long dry wall wood screws.The work shall be carried out as per specifications,drawing and as per directionsof the Engineer-in-charge. |
| 25 | Taking down Cement Plaster from wall and ceiling of any description from Brick/concrete surfaces including raking out Joints, hacking for Key, scrubbing down with Water, etc., and removing same from the Site(s), complete all as specified and as directed. (Note :- Rate included for four storey building including scaffolding and all safety measures) |
| 26 | M&L for 15mm thick rendering in patches in CM 1:4 on fair faces of brick or concrete surfaces including finishing even and smooth without using extra cement all as specified and as directed by Engineer in Charge. |
| 27 | M&L for 15mm thick rendering in patches in CM 1:6 on fair faces of brick or concrete surfaces including finishing even and smooth without using extra cement all as specified and as directed by Engineer in Charge. |
| 28 | M&L for 5mm thick rendering in CM 1:3 on concrete/gunniting surface as in ceiling finished even and smooth w/o using extra complete all as specified and directed by Engr-in-charge |
| 29 | M&L for prepration of new wall surfces and applying two coats distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour including a coat of primer over 1 to 2 mm thick birla putty punning by Sanding machine and auto roller complete, as per manufacturer\"s specification. Two or more coats on new work |
| 30 | M&L preparation of new plaster surface and applying two coats ofOBDof celing over a coat of primeronwall surfaces complete all as specified and directed by EIC. |
| 31 | M&L for prepration of new plaster surface of wall and applying Two or more coats of 100% Premiumexterior Acrylicall weather emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed by Engr-in-Charge. (Note:- work be carried out includig necessary scaffolding upto G+3 floor bldgs). complete all as specified and directed by Engr-in-charge |
| 32 | M&L for complete removal of existing treatment of old wallplaster surface and applying Two or more coats of 100% Premium exterior Acrylicall weather emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed by Engr-in-Charge. (Note:- work be carried out includig necessary scaffolding upto G+3 floor bldgs).by Engineer-in-Charge. |
| 33 | M&L for Complete removal of existing treatment of wall surfaces and applying two coats distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour including a coat of primer over 1 to 2 mm thick birla putty punning by Sanding machine and auto roller complete, as per manufacturer\"s specification. Two or more coats on new work |
| 34 | Providing and injecting chemical emulsion for Post Constructional Anti-termite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete |
| 35 | M&L for ATT Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron. complete all as specified and directed by Engr-in-charge |
| 36 | S&F PVC Solid moulded Architrave DoorFrame of Size 50X47mm & more made out ofmin 5.0mmColoured with Plastic Trim decoratedPVC Sheet Reinforced with Mild Steel Square Tube as specified Manufacture’s Instructionscomplete all as specified and as directed by Engr-in-charge |
| 37 | S&F Factory Made PVC Solid moulded DoorShutter 28 to 30mm thick (Stiles) with 2,4 of 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face specified Manufacture’s Instructionscomplete all as specified and as directed by Engr-in-charge |
| 38 | S&F for 30 mm thick flush shutters, solid core construction, with block board and both faces are covered with 0.90 mm thick decorative face veneer with lipping/ frame to match, complete, fixed to chowkatsall as specified and directed by Engineer-in-Charge. |
| 39 | M&L Second class hard wood plain solid straight chowkat &frame wrought rebated on solid rounded, complete all as specified and directed by Engineer-in-Charge. |
| 40 | S&F Mild steel works Fe-290, Gde -165 as in framed works such as door frame using box section/ grills/ guard bar and railing with ends of bars shoulders and or riveted or forged into spiked complete.by Engineer-in-Charge. |
| 41 | S&F Mild Steel Butt Hinges 100mm, Medium Weight, Cold Rolled ISI Marked and fixed, complete all as specified and as directed by Engineer-in-Charge. |
| 42 | S&F 250 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (Bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed by Engr-in-Charge. |
| 43 | S&F 200 mm long aluminium anodized barrel tower bolt of extruded section complete.all as specified and directed by Engr-in-Charge. |
| 44 | S&F 150 mm long Aluminium anodised handles, cast type, complete .complete all as specified and directed by Engr-in-Charge. |
| 45 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup complete all as specified and directed by Engr-in-Charge.MAKE: GOLDPLUS/MODI GUARD/SWASTIK. |
| 46 | M&L for preparation new or previously surfaces of steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 47 | M&L for preparation old decorated surfaces of steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed. by Engr-in-Charge. |
| 48 | M&L for preparation of new surfaces of wood or wood based materials over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of zink primer complete all as specified. by Engr-in-Charge. |
| 49 | S&F dismantling water tanks and removing to store,capacity in500 ltrs rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed including 20 or 25 mm dia float volve etc necessary fittingsin position includingcomplete all as specified and directed by Engr-in-charge . |
| 50 | S&F Galvanised Steel Water Tubing 15mm Bore (dia), ‘Medium Grade’ with all Fittings, fixed to concealed or onWalls, Ceiling or laid in Floors or any other Situ-ation including Taking up down unserviceable Steel Water Tubing with Fittings and Connections, etc. complete all as specified and as directed. by Engr-in-charge |
| 51 | S&F Galvanised Steel Water Tubing 20mm Bore (dia), ‘Medium Grade’ with all Fittings, fixed to concealed or onWalls, Ceiling or laid in Floors or any other Situ-ation including Taking up or down unserviceable Steel Water Tubing with Fittings and Connections, etc. complete all as specified and as directed. by Engr-in-charge |
| 52 | S&F for 20mm dia CPVC SDR 11 pipefixed to concealed/wall, ceilling,laid in floor etc incl all fittings with solvant anf brass threaded fittings for fixing taps etc including Taking down unserviceable 15 mm Steel Water Tubing 20mm with Fittings and Connections, including water tighteness test etc., complete all as specified and as directed. by Engr-in-Charge. |
| 53 | S&F for 25mm dia CPVC SDR 11 pipe fixed to concealed/wall, ceilling, laid in floor etc incl all fittings with solvant and brass threaded fittings for fixing taps etc including Takingdown unserviceable 20 mm Steel Water Tubing with Fittings and Connections, etc., including water tightness test complete all as specified and as directed. |
| 54 | S&F 15 mm dia fancy type Bib taps, Cromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or forbrass ferrule and fixed, complete all as specified and as directed by Engr-in-Charge. |
| 55 | S&F15 mm dia concealed Stop valves, cast copper alloy, screwed down,high pressure,with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. |
| 56 | S&F in repairs 15 mm dia Stop valves/ angle cock, cast copper alloy, screwed down,high pressure,with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. |
| 57 | S&F in repairs, 20 mm Bore gun metalGate/Globe half turn valves with iron wheel/Lever fixed-in-repairs complete all asspecified and directed byEngineer in charge. |
| 58 | S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 m long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified, complete as all specified and directed. by Engr-in-Charge. |
| 59 | S&F in repair Vitreous China Wash down Water Closet Pan (Pedestal Pattern) White including fixing Bolts (Excluding Flushing Cistern and Flushing Pipe) with Plastic Water Closet Seat, White, Closed Pattern with Recessed Bottom and Cover including SS Steel Chromium Plated Hanging Device, including Making Good disturbed Surfaces with Cement Mortar 1:3, complete all as specified and as directed by Engr-in-charge |
| 60 | S&F in repair PVC Flushing Cistern 10 LITRE capacity, Low Level Valve Less, Symphonic Action type, White, with Inlet, Ball Valve, Float and Handle including a Pair of Cast Iron Brackets duly Painted/Erecting Stand and PVC connection pipe 15mm size, PVC Flush Pipe of polythene 32mm dia for Low Level Flushing Cistern including Cutting and Pinning in Ends, Making Good Disturbed Surfaces in Cement Mortar 1:3 and fixed including Taking down/out Unserviceable Flushing Cistern and connected Items, complete all as specified and as directed by Engr-in-charge |
| 61 | S&Fin repair Vitreous China Wash Hand Basin 630X450mm in size, White (Flat Back Type) with 32mm dia Brass Chromium Plated Waste Fitting, Chromium plated pillar tap, UPVC’ 32mm bore Waste Pipe, a Pair of Cast Iron Brackets duly Painted/ Erecting Stand including Cutting and Pinning in Ends, Making Good Disturbed Surfaces in Cement Mortar 1:3 and fixed including Taking down Unserviceable Wash Hand Basin and connected Items, complete all as specified and as directed. |
| 62 | Supply & Fixing vitreous china urinal half stall type with CP spreader white incl CP waste coupling with grating and union fordischarge pipe, including providing and fixing plug, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement fixing with brackets, flush pipe, grating and union for discharge pipe complete all as specified and directed. |
| 63 | S&F in repair Chromium plated shower roses with Stainless Steel extension rod with swivel joints, of 125 mm size,including fixing to steel pipe or union complete all as specified and as directed by Engr-in-Charge. |
| 64 | S&Fin repair for high pressure PVC connection pipe 15mm dia with Brass CP Check nut and rubber washer complete with 600 mm length complete all as specified and as directed by Engr-in-Charge. |
| 65 | S&F in repairs Brass CP Towel Rail 600mm Long, as Approved, fixed complete as all specified and directed by Engr-in-Charge. |
| 66 | S&F in repair cut or full Gratings, 75 to 100 mm dia including CM 1:3by Engr-in-charge |
| 67 | S&F Fency type Glass shelf of size 600 x 120mm x 5.5mm thick glass with CP railling complete all as specified by Engr-in-charge |
| 68 | Dismantling of old existing Cast Iron pipes of any description, jointed in cement mortarup to 100 mm dia and removing to store. by Engr-in-charge |
| 69 | Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and not exceeding 1.5m deep in Soft / Loose soil complete all as specified and as directed by Engineer -in Charge.. |
| 70 | M & L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) in foundations, filling and mass concrete complete.by Engr-in-charge |
| 71 | Returning filling in the soil including spreading, levelling, watering and well ramming in layer n.exc 25cm thick each layer complete all as specified and directed by Engineer-in-Charge |
| 72 | Demolation of brick work built in cement mortar or cement lime mortar as cutting, opening of exsiting wall complete all as specified and direced. by Engr-in-Charge. |
| 73 | M&L brick work with sub class \"B\" bricks straight curved on plan exc 6 mean radius built in CM 1:6 by Engr-in-charge |
| 74 | All as per Srl item No 72 above but except bricks (old dismantled serviceable bricks obtained from Srl item No 69 shall be reused after necessary cleaning of mortar). by Engr-in-charge |
| 75 | Extra for forming fair finised drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds mitred/stopped ends etc complete all as specified by Engr-in-Charge. |
| 76 | Material and Labour for PCC 1:2:4 type B0 using 12.5 mm graded crushed stone aggregate as in surface channels and drain complete all as specified |
| 77 | M&L forbrick work with sub class \"B\" bricks (old size) straight or curved on plan exc 6 m mean radius, in half brick thick walls and built in CM1:4 complete all as specified and directed. by Engr-in-charge |
| 78 | Demolition/Breaking up Drain Pipes (SGSW),AC/RCC 150 mm to 200 mm dia, Jointed in Cement Mortar of any description including demolition of PCC bed/haunching of the Pipes,complete all as specified and asa directed by the Engineer-in-Charge. |
| 79 | M&L for reinforced cement concrete pipe 150 mm dia class NP2 laid and jointed complete with collars as in sewar lines and jointed complete all as specified and as directed by Engr-in-charge. |
| 80 | M&L for Cement Concrete (1:3:6) Type C1 (20mm Graded Stone Aggregate) Bed for Drain Pipes of Bore 150mm including Packing under and Haunching against the Sides of Pipes after they are laid in Foul Condition and Testing, complete all as specified and as directed. by Engr-in-charge |
| 81 | M&L in repair of 75mm outlet CI floor/nahani trap with steel grating including jointing and breaking/ dismantling any type of floor and making good cement concrete to the B-1 (1:2:4) and testing after repairs and taking down existing trap etc complete all as specified and directed by Engr-in-Charge |
| 82 | S&F stack clamp out of 50 mm by 5 mm flat GI angle and 16 mm dia round iron stays/ U bolt and nut with washer for 75 and 100 mm dia pipe, complete in all respect as speicifed and directed by Engr-in-Charge. |
| 83 | S&F in repair 110 mm bore (dia) of PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete in all respect as specified and directed by Engr-in-Charge. |
| 84 | S&F in repair75 mm bore (dia) PVC (SWR) Pipes , Single Socketed, in any length with Rubber Ring Joints fixed to Walls or Laid in Floors, etc, including Taking down /up unserviceable Pipe, complete all as specified and as directed. by Engr-in-charge |
| 85 | S&F 110 mm bore of PVC (SWR) bends any radius, complete all as specified and directed by Engr-in-Charge. |
| 86 | S&F 75 mm dia (bore) PVC (SWR) Bend with access door, jointing with Solvent Cement, complete all as specified and as directed by Engr-in-Charge. |
| 87 | S&F in repair Stainless Steel Kitchen Sink with Drainage Board of Overall Size 915X460mm and Bowl Size 410X330X160mm, made of Stainless Steel 1.0mm thick Sheet with Plugs, Chromium Plated Waste Coupling and Washer including Bedding in Cement Mortar 1:4 to Dwarf Wall or fixing Cantilever Brackets and Connection to Pipe including Taking down unserviceable Sink and Connected Items complete all as specified and as directed by Engr-in-Charge. |
| 88 | S&F in repair,Stainless steel Plate rack of size 24\"x36\"x10\"(all dimensions in inches) complete all as specified and directed by Engr in charge Cat Part No-KR-572 of Make-Shakti or equivalent out of makes specified in list of makes. by Engr-in-Charge. |
| 89 | Demolition of cement concrete in ground floor & paving n.exc 15cm above ground level complete all as specified an directed by Engr-in-Charge. |
| 90 | M&L for 75mm thick cement cocnrete type C-1 (1:3:6) (20mm graded aggregate) as in plinth protection finishing the surface even and faircomplete all as specified and directed by EIC. |
| 91 | M&L for 100 mm thick cement concrete 1:2:4 type B-2 using (40mm graded stone aggregate ) as in sub base of floor path and hard standing complete all as specified and directed by Engineer in Charge. |
| 92 | DemolitionReinforcement Concrete wall beamin suspended works all as specified and directedby Engr-in-charge |
| 93 | S&F rolled mild steelas in joist channel,angle,or tee section, fixed independently,without cooecting plates etcGde Fe-410-W etc.all as specified and as directed by Engineer in Charge. |
| 94 | M&L for reinforced Cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregates) as in chajjas, facia and the like complete all as specified and directed by Engr-in-charge |
| 95 | Use and waste of formwork to Chullah hoods, chajjas,slab, weather shades, corbels, water troughs and similar items including edges rough finished surfaces of concrete complete all as specified and directedby Engr-in-charge |
| 96 | S&F mild steel TMT bars 10 mm dia., cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire ( annealed) not less than 0.90 mm dia. Or securing with clips complete all as specified and directed |
| 97 | Demolition of Stone slab and tiles laid dry of any description or thickness in floors,apronsby Engr-in-charge |
| 98 | M&L for 60mm thick Machine pressed precast concrete Glazed inter locking paver block M-35 Gde any shape and size with white cement andpigment conforming to IS 15658-2006 over sand cushioning, including patch work etc as specified and as directed by Engr-in-charge |
| 99 | Dismantling Plain or corrugated steel/ sheeting any guage, thickness, including removing to store etc all as specified and as directed by Engineer in Charge. |
| 100 | S&F Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified by Engr-in-charge. |
| 101 | S&F Pre-painted galvatume aluminum zinc coating GI based Plan steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified by Engr-in-charge. |
| 102 | M&L for Excavating in post holes( or similar holes) in soft/loose soil each n exc 0.5 cu.m. getting out, returning,filling in and ramming earth of broken rubble mixed with earth around , in layers not exceeding 25 cm, watering all as specified and as directed by Engineer in Charge. |
| 103 | M&L for black bituminous paint with two coat of surfaces of any description wood, steel, iron, concrete ,brick, stone etc exceeding 10 cm in width or girth all as specified and as directed by Engineer in Charge. |
| 104 | M&L for PCC (1:3:6) type C2 using 40mm graded aggregate for foundation filling and mass concrete etc complete all as specified and as directed by Engineer in Charge. |
| 105 | Dismantling wrought iron or mild steel / structural steel work of any description not otherwise provided for, complete in all respect as specified and directed by Engr-in-charge. |
| 106 | S&F mild steel Gde Fe-410-W as in roof trusses, (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee,angle,channel or flat sections) including distance pieces , cleats etc.all as specified and as directed by Engineer in Charge. |
| 107 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S 1161-1979 grade St. 240 etc all as specified and as directed by Engineer in Charge. |
| 108 | M&L two coats of synthetic enamel painting on steel surfaces of any description over 10 cm in width or girth not otherwise described above priming coat of red oxide including prepration of previously untreated surfaces etc all as specified and as directed by Engineer in Charge. |
| 109 | Removing of old debris obtained from excavation/demolition building material to a distance exc 10 Km but n exc 15 Km and deposited out side the MD land as per NGT norms. Note :- Searching of Place of Disposal out side the MD Land will be the responsibility of Contractor and rate of any distance shall be included in quoted unit rate all as specified and as directed by Engineer in Charge. |
| 110 | M & L for Granite 20mm thick (of any type )(table rubbed and polished) in steps, jambs , pillars, window-cills, coocking platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified & directed by Engineer-in-Charge. |
| 111 | M & L for Providing edge moulding to18-20mm thick stone (granite) of counters vanities, stepsetc including machine polishing to edge to give high gloss finish complete all as specified & directed by Engineer-in-Charge. |
| 112 | M & L for providing epoxy stone adhesive to join 20mm thick granite by preparing granite surface & Mixing and applyings epoxy as in layer of 3mm as per manufacturer instructions given, complete all as specified & directed by Engineer-in-Charge. |
| 113 | All as per Srl item No 76 above but except bricks (old dismantled serviceable bricks obtained from Srl item No 01 shall be reused after necessary cleaning of mortar). by Engr-in-charge |
| 114 | M&L forRCC Nominal Mix type B0 1:2:4(using 12.5 mm graded crushed stone aggregateas in Lintel Band,Beams, cantilevers, lintelsover1.5mspancompleteall as specified and directed.by Engr-in-Charge. |
| 115 | Material and Labour for PCC 1:2:4 type B0 using 12.5 mm graded crushed stone aggregate as in in roof kerbs rounded on edges coping like including weathering ,slightly rounded or chamfered angle and throating as complete all as specified |
| 116 | M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers,lintels,cantilevers,shelvesincluding supports, overhangs,etc. also splays between floors and beams, etc. for roughfinishedcompleteall as specified and directed. by the Engineer-in-Charge. |
| 117 | M&L for mild steel TMTbars 5 mm dia bars and over, uptoandincluding10mmdiaasinstirrupscutto length,benttoshaperequired,includingcranking, bendingspirallyforhoopingforcolumns,hookingends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. by the Engineer-in-Charge. |
| 118 | Material & labour for Rolled mild steel work Fe 410 -W (Grade E- 250) quality A, as in fencing posts with or withoutY/U/Swan Neck made of angle or other section, made to shape complete, welding, drilled for fixing or holding of barbed wire or chain link mesh , etc. or for fixing or holding of fibre glass sheet ; to be prepared for hanging or steel hangingfittings; also fastening and fixing complete all as specified & directed by the Engineer-in-Charge. |
| 119 | Supply & fixing in repairs Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified & directed by the Engineer-in-Charge.Note :- Each line wire to be measured separately. |
| 120 | S& F of concertina coil/wire fencing with razor wire 600 mm internal dia and straining & Fixing to rcc/Steel/Angle posts nibs including securing or tying at crossings with and provisions of galvanised MS wire stapes or steel etc.complete all as specified.and direced. by Engr-in-Charge.( Not ;- Weight range of1.20 to 2.2 kg Per Rm) |
| 121 | Schedule-A (E/M Work) |
| 122 | Taking down carefully copper/aluminium point wiring (light, Fan, Socket or power) fitting such as switches, ceiling roses, pendents, regulators, sockets etc complete removing material to store for keeping in safe custody and making good disturbed surfaces of walls, floors etc all as specified as directed. |
| 123 | Taking down carefully by unscrewing from theboards/outlets boxes fittings and fixturessuch as switches, sockets ceiling, rose, lamp holders, tube light fittings, regulators etc and making good of disturbedsurfaces |
| 124 | Taking down ofexisting old unserviceable submain wiringcomplete all as specified and as directed. |
| 125 | Taking down ofexisting old unserviceable MCB of any ratingcomplete all as specified and as directed. |
| 126 | Taking down ofexisting old unserviceable distribution boardof any type complete all as specified and as directed. |
| 127 | Taking down of LED T/L/Ceilling light/Round light/Bulkhed light of any type and capacity complete all as specified and as directed. |
| 128 | Material & Labour for concealed point wiring with single core PVC insulated and unsheathed 1100 volts grade cable with multistranded copper conductor of size 1.5 Sqmm nominal area drawn through & including non metallic rigid PVC conduit (circular/flat pvc conduit), medium duty not less than 20 mm dia concealed in wall/fixed on wall/ceiling with GI saddles , GI screws , rawl plugs with all fittings including tees , junction boxes & provision for modular box and modular cover of suitable size for mounting modular switches , sockets & regulators & drawing through continuous earth wire of PVC insulated unsheathed 1100 volts grade cable with copper conductor solid conductor of size 1.5 sqmmcomplete all as specified & directed by Engineer -In-Charge.Note: Cost for cutting chases and making good to match the existing surface shall be deemed to be included in the quoted rate. |
| 129 | For one light point controlled by one single pole switch & socket. |
| 130 | For one fan/exhaust/wall mounted point controlled by one single pole switch. |
| 131 | For one 3 pin sockets outlet 5 Amps on the same board with other switches with cable of size 1.5 sqmm |
| 132 | For 3 pin socket outlet 5Amps independent with cable 1.5 Sqmm size |
| 133 | For one 3 pin sockets outlet 15 Amps idependent with cables 2.5sqmm size |
| 134 | Supply and Fixing of modular switches 1 way, 6 Amp 1 module complete all as specified & directed by Engineer - In-Charge. |
| 135 | Supply and Fixingmodular Socket, 6A - 2/3 pin combined 2 module, complete all as specified & directed by EIC. |
| 136 | Supply and Fixing of modular switches 1 way, 16 Amp 1 module complete all as specified & directed by Engineer - In-Charge. |
| 137 | Supply and Fixingmodular Socket 6A/16A - 2/3 pin combined 2 module, complete all as specified & directed by EIC. |
| 138 | S&FGI Modular gang sunk-in pressedterminal boxes of required size not less than 1.2 mm thick factory made for following module complete all specified and directed.Note: Flushing of module box in wall with cement and repairing the wall as before is deemed to be included in quoted rate. |
| 139 | Metal flush box 3 module |
| 140 | Metal flush box 6 module |
| 141 | Metal flush box8 module |
| 142 | Metal flush box12 module |
| 143 | S&F white cover plate with frame of following module complete all specified and directed. |
| 144 | White cover plate with frame 3 module |
| 145 | White cover plate with frame 6 module |
| 146 | White cover plate with frame 8 module |
| 147 | White cover plate with frame 12 module |
| 148 | Supply & Fixing of Ceiling Rose, 3 phase polycarbonate isolated body complete all as specified & directed by Engineer - In-Charge. |
| 149 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light completewith driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable sizecomplete. |
| 150 | S&F submain wiring withunsheathed multi-stranded FR Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 20mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 6 Sqmm single core HR Grade and one run of 6 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB/ AC plug points complete all as specified and as directed.Note :- Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete.Note: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit. |
| 151 | Ditto as above item but sub main wiring 2x1.5 sq.mm +1x1.5 sq. mm earth wire . |
| 152 | Ditto as above item but sub main wiring 2x2.5 sq. mm + 1x2.5 sq. mm earth wire. |
| 153 | Supply , Laying , testing and commissioning in replacement of XLPE insulated and PVC Sheathed , galvanized steel strip or wire armoured , heavy duty electric cable with multi stranded aluminium conductor, 1100 volts grade of size 70 sqmm 3.5 core complete all as specified & directed by Engineer - In - Charge. |
| 154 | M&L for dry clean sand filling in trenches below and around under ground cable cushioning complete all as specified and directed. Note :-Thickness of sand cushioning shall be measured after punning. |
| 155 | M&L for brick protection with sub class \"B\" Designation 75 old bricks laid dry flat 23cm in width over sand cushioning in trenches as perpendicular to the direction of underground cable complete all as specified and as directed. |
| 156 | S&F in repair GI pipe light grade 50mm bore in trenches/wall/poles for protection of cable complete all as specified and as directed. |
| 157 | M&L Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and as directed. |
| 158 | S&F in repalcement of MCB SP 6-32 Amps ,10 KA 230 Volts ,50 HZ complete all as specified and as directed by Engineer -in -charge .Make : Make: Legrand /Siemens/Schneider. |
| 159 | Supply and fix in replacement of factory made epoxy polyster powder coated VTPN distribution boardTriple pole MCB4 way 415V fabricated from minimum 1.6 mm thick CRCA sheet with double door (IP-43 protection) fixed flush to wall and standard DIN rail, earth bar and cable ties for cable management, provision for 125 Amps MCCB as one incommerand 12 outgoings single pole MCB with 2 Neutral bar, 2 Earthbar, Fully insulated busbar rated capacity above 160Amp, shrouded Neutral bars and cable ties for cable management complete all as specified and confirming to IEC 61439-3,Reversible door IP 43 & IP 54. Make: Legrand /Siemens/Schneider. Note: Cutting on wall and taking out old one and then flushing new DB and making all the connection as before and any accessories required to fix the DB including making good the disturbed surface is deemed to be included in quoted rate. |
| 160 | Supply & Fixing MCCB 125 Amps4 Pole, 415 V, fixed thermal & fixed magnetic setting electromechanical type with Ics=75 % of Icu , with breaking capacity 16 KA conforming to IS: 13947-II complete all as specified and as directed. |
| 161 | Supply and fix in replacement of factory made epoxy polyster powder coated distribution board double doorSP&N 8 way 240V fabricated from minimum 1.6 mm thick CRCA sheet with double door (IP-43 protection) fixed flush to wall and standard DIN rail, earth bar and cable ties for cable management, suitable for one incomingand 6 outgoings complete all as specified and confirming to IS: 8623 (Make: Legrand /Siemens). Note: Cutting on wall and taking out old one and then flushing new DB and making all the connection as before and any accessories required to fix the DB including making good the disturbed surface is deemed to be included in quoted rate. Make: Legrand /Siemens/Schneider. |
| 162 | S&F Fan modular fan regulator 4 step, 1 module, complete all as specified & directed by EIC. |
| 163 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete all as specified and as directed. |
| 164 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed. |
| 165 | Supply & fix Air Circulator wallmounted fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting completeall as specified and asdirected.Note -appropriate nut bolts for fixing of wallmounted Fan will be deemed to be included by rate quoted by contractor. Make: Crompton model : ACVORTEX18WM or equivalent another make. |
| 166 | Note:- The amount of Rs 69336/- against Schedule of Crediton Srl Page 153 to 154 shall be deducted from the total amount quoted against Sch \"A\" |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy