| 1 | M & L forServicing and repair ofvoltage stabilizer of capacity upto 20 KVA after disconnecting all electrical connections of stabilizer and check the auto/manual function of stabilizer, to check the oil level, oil seal leakage if any, check voltmeter and Amp meter working condition or not. Taking out top cover of stabilizer for replacing defective spares/ items, cleaning the dust by air blower, check the neutral and earthing connections properly to check all nuts, bolts tightining and refixing the same in existing position and reconnect all the incoming/ outgoing cables properly including testing and commissioning, complete all as specified and as directed. Note :- (i) Replacement of defective spares for making the voltage stabilizer units in satisfactory working condition shall be measured & paid separately under relevant items as \"Supply only\" (ii) Labour charges for taking out old spares & refixing of new spares shall deemed to be included in unit quoted rate. |
| 2 | All as per item No. 1.00 here in above but 100 KVA, complete all as specified and as directed. |
| 3 | All as per item No. 1.00 here in above but150 KVA complete all as specified and as directed. |
| 4 | Supply only electronic servo circuit card (PCB), complete all as specified and as directed. (Make:- AE/ APLEB/ ANDREWYULE /SINETRAC/ VOLINA/ VINITEC/ IECO/ V-GUARD/ INDIAN TRANSFORMER & ELECTRICALS PVT LTD. |
| 5 | Supply only servo control panel, complete all as specified and as directed. (Make:- AE/ APLEB/ ANDREWYULE /SINETRAC/ VOLINA/ VINITEC/ IECO/ V-GUARD/ INDIAN TRANSFORMER & ELECTRICALS PVT LTD. |
| 6 | Supply only trigger (control) transformer 9V/18V, complete all as specified and as directed.(Make:- AE/ APLEB/ ANDREWYULE /SINETRAC/ VOLINA/ VINITEC/ IECO/ V-GUARD/ INDIAN TRANSFORMER & ELECTRICALS PVT. LTD.(GURGAON) |
| 7 | Supply only carbon brush , complete all as specified and as directed.(Make:- AE/MECO/ L & T (RISHABH)/AMTL/SECURE/ C & S ELECTRIC/ DUCATI/ RAAS CONCORD) |
| 8 | Supply only dimmer 8 Amps, complete all as specified and as directed.(Make:- AE/MECO/ L & T (RISHABH)/AMTL/SECURE/ C & S ELECTRIC/ DUCATI/ RAAS CONCORD) |
| 9 | Supply only dimmer 40 Amps, complete all as specified and as directed.(Make:- AE/MECO/ L & T (RISHABH)/AMTL/SECURE/ C & S ELECTRIC/ DUCATI/ RAAS CONCORD) |
| 10 | Supply only dimmer 60 Amps, complete all as specified and as directed.(Make:- AE/MECO/ L & T (RISHABH)/AMTL/SECURE/ C & S ELECTRIC/ DUCATI/ RAAS CONCORD) |
| 11 | Supply only dimmer 125 Amps, complete all as specified and as directed.(Make:- AE/MECO/ L & T (RISHABH)/AMTL/SECURE/ C & S ELECTRIC/ DUCATI/ RAAS CONCORD) |
| 12 | Supply only servo motor 3 K.G torque single phase with RC, complete all as specified and as directed. (Make:- AE/ APLEB/ ANDREWYULE /SINETRAC/ VOLINA/ VINITEC/ IECO/ V-GUARD/ INDIAN TRANSFORMER & ELECTRICALS PVT. LTD.(GURGAON) |
| 13 | Supply only servo motor 10 K.G torque single phase with RC, complete all as specified and as directed. (Make:- AE/ APLEB/ ANDREWYULE /SINETRAC/ VOLINA/ VINITEC/V-GUARD/ INDIAN TRANSFORMER & ELECTRICALS PVT. LTD.(GURGAON) |
| 14 | Supply only rotary switch 5 Amp for R.Y.B phase, complete all as specified and as directed. (Make:- AE/ L & T (RISHABH)/SECURE/ C & S ELECTRIC/HAVELLS/ ANCHOR) |
| 15 | Supply only PCB holder, complete all as specified and as directed. (Make:- AE/ APLEB/ ANDREWYULE /SINETRAC/ VOLINA/ VINITEC/ IECO/ V-GUARD/ INDIAN TRANSFORMER & ELECTRICALS PVT. LTD.(GURGAON) |
| 16 | M & L for refilling/topping up/replacement of stabilizer oil with new dehydrated stabilizer oil. Open lid cover of stabilizer including changing of gasket set if required complete and re-fixing of top lid cover without any damage to stabilizer suitable for working voltage 440 volts grade including necessary dehydration to achieve dielectric strength min 40 KV including internal/external connection and testing on load of stabilizer, complete all as specified and as directed. (Make:- HPCL(SEETAL)/ HP (SEETAL)/ SERVO/GULF/ CASTROL) |
| 17 | Supply and fix in replacement 4 pole power contactors Type MCX of rating up to50 Amp with suitable coil voltage as per site requirement /make /Base size as match with existing complete all as per Make : L &K /C & S / Siemens. |
| 18 | Supply and fix in replacement 4 pole power contactors Type MCX of rating200 Amp with suitable coil voltageas per site requirement /make /Base size as match with existing complete all as per Make : L &K /C & S / Siemens. |
| 19 | Supply,install,test and commissioning of out door typedouble doorLTpanel made out of 3.0 mm thick CRCA sheet , made out from CPRI Approved firm, totally enclosed weather dust and vermin proof as per ISwith frontopening suitablelocking arrangement having copper bus bar of 600 Amp capacity for RYB andneutral and insulated with insulators,including connecting incoming and outgoing cables, with necessary PCC 1:3:6 in foundation and made out of 50 X 50 X 6 mm angle iron grouted at groundand30 cm above from ground level Comprising the followingall as specified and as directed by the engineer - in-charge. Note: Cost includes necessary internal wiringfor meters , CT\"s as required for operation of AMF panel / ATS ,indication lamps,etc and Rigid copper bus bar connections from bus bar to MCCB terminalsand suitable size copper wire for control wiring and Indicating lamps complete all asdirected. Make: CPRI approved manufacturer(a) MCCB 320 Amp, 36 KA -02 Nos(b) ATS 400 Amp with necessary power pack suitable rating ,necessary Auxillary contactors as required site for smooth operation of ATS- 01 Nos(c) Indicating lamp , RYB forMain andstand bySupply - 01 Set (d) Indicating lamp for Load onLoad on Main/Load on Stand By supply- 01 Set (e) Led type Dual SourceMulti Function Meter- 01 Nos (f)Control wiringwith suitable rating copper conductor multi standed from ATS to Main Supply /Stand BY Supplyfor Operation of Automatic Transfer operation of Power supply , - 01 Job Note: Rate include necessary control wiring from DG set to to AMF panel/ATS forAuto manual operation |
| 20 | M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick burried directly in gorund (earth pit not less than 2.25 Mtr normal ground level),and top edge of earth plate not less than 1.5 mtr below normal ground level,using galvanised iron strip 25×4mm as earthing lead with bolts, nuts & check nuts, and washers of galvanised iron protection pipe light grade of 40 mm dia and watering pipe medium grade of 20 mm dia and filled with alternate layer of charcoal and common salt, watering funnel with wire mesh, earth pit chamber and cover CI frame PCC 1:3:6 type C-2 all as shown in electrical plate No-3 of SSR part-I of 2009 connected to earthing test point all as specified and indicated including all earth work excavation, returning filling and disposal of surplus soil and testing on completion. |
| 21 | S & F in replacementtest point terminal block made of phosphorus bronze size 75 x 75 x 25 mm thick drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screws fixed to copper strip bracket fixed in MS box of of suitable sizeon wallascomplete all as specified and directed |
| 22 | Supply and fixingreplacement porcelain vitreous white/brown/green spacers insulator of size 75mmx35mmx40mm height complete with one number galvanized iron stud bolts 6mm dia x 40mm long including nut & washers and two number galvanized iron fixing bolts of size 6mm dia and 50 mm long including washers and drilling holes for holding /foxomg aluminium strip/roof conductor as required including taking down the broken insulator complete all as specified and as directed by the Engineer-in-Charge. |
| 23 | M&L in replacement Tubes,lightgrade\" galvanised, with all fitting and fixed complete to walls and ceilings by flat iron clamp nuts bolts etc complete or laid in floors 40 mm dia complete all as specified and directed. |
| 24 | Supply and fix inreplacementVolt meter 0-500 Volt , three phaseDigital type of size 96 X 96 Sq mm flush mounted casein existing panelincludingwiring from bus bar to volt meter terminals so as to match with the existing control wiring complete all as specified and as directed by the engineer - in-charge [Make: Neptune/ AEI/ Meco/ HPL/L & T] |
| 25 | Supply and fix inreplacementDigital Ammeter three phaseof size 96 X 96 Sq mm flush Mounted of following rangein existing panel with necessary wiring from CT to Ammeter and so as to match with existing control wiringcomplete all as specified and as directed by the engineer - in-charge.[Make: Neptune/ AEI/ Meco/ HPL/L & T] |
| 26 | Supply and fixinreplacementcurrent Transformer of50 /5 CT ratio,Indoor tape INsulated Ring typein existing panel in cludintg taking down old unserviceble CT\"s of any make /Ratingcomplete all as specified and as directed by the engineer - in-charge . [Make :Neptune /AE / Kappa] |
| 27 | Allas per the item no 26above but for CT ratio 100 /5 Amps . |
| 28 | Allas per the item no 26above but for CT ratio 150 /5 Amps . |
| 29 | Supply and fixing in replacement MCCB in of followng ratingsin existing board connecting with proper sizelink set at incomming and out going cable connections and making necessary modification in existing panel as required complete allas specified and directed by EIC . Note: cost in clude taking downthe existing MCCB from panel board and incoming / outgoingcable and fix the new MCCB inposition atpanel board / incoming / outgoingcable connections of any size/ rating. |
| 30 | MCCB 63 to 100 Amp 4 pole 16 KA ; Make: Legrand / L & k /Havell\"s/C & S |
| 31 | MCCB 125Amp 4 pole 16 KA ; Make: Legrand / L & k /Havell\"s/C & S |
| 32 | MCCB 200Amp 4 pole 25KA Make: Legrand / L & k /Havell\"s/C & S |
| 33 | MCCB 250 Amp 4 pole 25KA Make: Legrand / L & k /Havell\"s/C & S |
| 34 | Supply only copper winding wire with supper enamelled copper wire of suitable gauge as per capacity/Rating of Voltage stabilizer /LT transformerwindingcomplete all as specified and directed by Engr - in - charge. |
| 35 | M & L for Maintenance of LT ACB of rating from 630 Amp to2500 Amp 415 Volt 50 HZof any make installed at LT panel boards at NPOL complete by taking the shut down with prior intimation and cleaning the ACBby usingair blower tightning of connection of control circuit and complete checking ofall fuses, checking relayand control circuit for smooth functioning by employing one skilled tradesmanas andwhen requiredand also to carry outfollowing works.Note: Unit rate include forpreventive maintenance / attending break down as and when required. Check and clean incomming and out going terminals / compartmentChecking the servicebility of close and trip coil condition and taking out for repalcement.Checking the servicebilty of control circuit , relays ,fuses and Electrical /Mechanical interlocks,Replacing the spares such as Shunt release , UV release ,tripping/Closing coil shall be measured andpaid seperately under respective item. Note : (a) Rate Quoted deemed to be including cost ofreplacing small piece of control circuit wires up to 1.00 Mtrs , LT fuses and Push buttons for ON/Offif required . |
| 36 | Supply and fix in replacement shunt release for LT ACB 415/240 Volt AC up to 2500 Amp as per existing. Make : L & T( L & K)GE/Havell\"s/English Electric |
| 37 | Supply and fix in replacement under voltagerelease 415/230 Voltsuitable forLT ACB of rating up to 630 Ampas per existing Make : L & T ( L & K)/ GE/Havell\"s/ English Electric |
| 38 | Supply and fix in replacementearth fault release 415/230 Voltsuitable forLT ACB of rating up to 630 Ampas per existing Make : L & T ( L & K) / GE/Havell\"s/ English Electric |
| 39 | Supply and fix in replacementbreaker control modulesuitable forLT ACB of rating up to 630 Ampas per existing Make : L & T ( L & K) / GE/Havell\"s/ English Electric |
| 40 | Supply, install, test and commission of Automatic power factor improvement panel of50 KVAR capacity including APFC relay, capacitor of type heavy duty cylindrical , contactors and control wiring with copper wire in out door type panel board made out of 3.0 mm thick CRCA sheet, CPRI approved , including cooling fan,copperbus bar of 200 Amp capacity ,(independent cabin including locking arrangementforeach, bus bar chamber etc with all necessary protection etcand 125Amp capacity MCCB TPN rup capacity 16 KA as incomercomplete all as specified and as directed . The panel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm, bolted in ground /fllor mountedand comprising the following. Make: CPRI Approved Maufacturer |
| 41 | 100 Amp MCCB TPNRup capacity 25KA-01 No, Make: L&T /Havell\"s/Legrand/Indo Asian/C & SDigital V-A -Fmeter - 1 No. [Make: Neptune/ AEI/ Meco/ HPL ] CT\"s for ratio as required- 3 Nos[Make :AE / Kappa/PGR]R -Y -B phase Idicator lamps LED type - 1 set [Make : Neptune / L&T / Vaisnavo/C &S/HPL]MCB 6 Amp SP 10 KA - 6 Nos, Make: L&T /Havell\"s/Legrand/Indo Asian/C & S MCB6 to 32Amp TP 10 KA - 6 NosMake: L&T /Havell\"s/Legrand/Indo Asian/C & S6 - tage APFC relay with built in P.F Meter - 1 Set [Make :C & S Cat NO. RG-8T/ Equivalent in L & T/C & S ]LED type piolet lamp - 08 Nos [Make : Neptune / L&T / Vaisnavo/C &S/HPL]20 KVAR Capacitor banks, Cylindrcal type Heavy duty- 01- Nos (Make : EPCOS/ C & S/ L & T/)10 KVAR Capacitor banks, Cylindrcal type Heavy duty - 02 - Nos ( Make : EPCOS/ C & S/ L & T/)5 KVAR Capacitor banks, Cylindrcal type Heavy duty - 02 - Nos ( Make : EPCOS/ C & S/ L & T/)3- position selector switch centre off for auto Manual operation - 6 No. [Make : C & S /L & K ]Start /Stop Push button for mannual operation of Capacitor Banks - 06 Set ( 12 Nos) Capacitor duty contactorswith auxiliary contacts for KVA rating up to 20 KVAR -01 Nos Make: C & S/ L &k Capacitor duty contactorswith auxiliary contacts for KVA rating up to 10 KVAR -02 Nos Make: C & S/ L & T Capacitor duty contactorswith auxiliary contacts for KVA rating up to 05 KVAR -02 Nos Make: C & S/ L & T |
| 42 | Supply and fix in replacement Capacitor duty contactors with auxiliary contactsof following capacity including dismatling the existing duty contators of any rating/make and making connection to fuse links /MCB and capacitor bank complete alllas specified and as directed.Make: C & S/ L & K /Epcos |
| 43 | Capacitor duty contactor suitable for 50 KVAR |
| 44 | Capacitor duty contactor suitable for 25 KVAR |
| 45 | Capacitor duty contactor suitable for 20KVAR |
| 46 | Capacitor duty contactor suitable for 15KVAR |
| 47 | Capacitor duty contactor suitable for 12.5 KVAR |
| 48 | Capacitor duty contactor suitable for 5/8.5 KVAR |
| 49 | Supply and fix in replacement 8- tage APFC relay suitable for Single CT input ( CT Ratio 1A/5 A as per site)with built in P.F Meter after dismatling the existing meter from APFC unit and programme the newly installed relay unitas per OEM instructions or in presence of OEM representative to match with existing arragement of capacitor banks complete all as specified and as directed by engineer in charge. [Make :C & S /L & K ]/ Siemens |
| 50 | Supply and fix in replacementCapacitor banks, in existing APFC panel ,Cylindrcal type Heavy duty Suitable for Voltage rating up to 480 Volt,rating as required at site as specified and directed by EIC.(Make : EPCOS/ C & S/ L & T/)Note: Contractor has to replacethe capacitor banks as the same rating /Rating as directed as per site requirement with multiple unit ofCpacitor bank of5 KVAR to 50 KVAr as per site requirement. |
| 51 | Supply and ix in replacement LED type piolet lampsuitable for working voltage range up to 240 VoltAC . [Make : Neptune / L&K / Vaisnavo C &S/HPL] |
| 52 | Supply and ix in replacement Push button suitable for working voltage range up to 240 VoltAC . [Make : Neptune / L&K / Vaisnavo C &S/HPL] |
| 53 | Supply and fixing 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning |
| 54 | Supply and fix MCB 40 to63Amp 4 Pole ,10 KA complete all as specified and as directed |
| 55 | Supply and fix MCB 6 to 32 Amp 4 Pole ,10 KA complete all as specified and as directed |
| 56 | S& L sand cushioning for cableduct inside the HT/LT substaion to fill the duct all as specified and as directed . |
| 57 | Supply and fix in replacement 2KVA Inverter ,Pure Sine Wave 2000VA/ 24V; Peak Load: 1680W having Comprehensive protection against short-circuit, reverse polarity, battery over-charge, deep-discharge , Bypass switch for supplying output directly from grid in case ofUPS fault,with Battery Compatibility of2X (12V) battery of Capacity Between 80 Ah-220 Ah Battery ,Supports wide range of Batteries Like A Flat Plate, Tubular type , |
| 58 | S & F partical board one side laminated 18 mm thickwith aluminium channel at all side and mounting wall with necessary bracket fixed towallfor fixing the drawings / Chartsall as specified and as directed byEngr-in Charge |
| 59 | M & L for paste flexboard/ Printed sheeton partical board dully print of single line diagram of HT and LT cables / Installation details / equipment details /installation notice boards /shoke treatment charts etc in multi colour all as specified and all as directed by Engr-in ChargeNote: (i) Rough drawing /Details (Hard copy) of equipment and plantwill begiven by Department. The contractor has to develop the same with legends/ signs asper the standards on computer in multicolour and same get it approved from engineer in charge .(ii) Installation / equipment details including the details of all equipments in plant like switch gear units , pumps, compressor and valves, contractor has to develop the drawing in multi colour using proper legends as per standards |
| 60 | M & L for laying grade stone aggregate of size 40 mm in E/M installation all as directed by EIC. |
| 61 | M & L for laying graded stone aggregate of size 20 mm in E/M installationall as directed by EIC. |
| 62 | M & L for laying graded stone aggregate of size 12.5mm in E/M installationall as directed by EIC. |
| 63 | M& L for surface excavation at E/Minstallations andstore yardsnot exceeding 30 cm deep and averaging 15 cm deep and getting out soft / loose soilremovingshrubs, small trees height up to 1.0 Mtrs , removing the grass from route as directed , Note : (i) Rate includesremoving all waste material and grass not excceding 50 Mtrs distance from installation ,depositing where directed at a level not exceeding 1.5 Mtrs above the starting pointand cleaning of yard , Complete all as specified and directed by EIC. (ii) Cleaning should repeated in same installation in every three months |
| 64 | Supply and fix Non-Magneticsmooth and clear surfaced boards, White Boardswith aluminium channel at all side includingtwo numbers of regularer erasablemarker pens and one dusterwith necessary fixing arrangments to fix in wall/ stand as directed by Engineer in charge |
| 65 | Supply and fix Pin-Up Board, , with aluminium channel at all side includingtwo numbers of regularer erasablemarker pens and one dusterwith necessary fixing arrangments to fix in wall/ stand as directed by Engineer in charge |
| 66 | M&L for cross arm ,bracings,support,clamps and back plates fabricated from structural steel section including nuts, bolts,washer, welding ,drilling hole for bolts ,bending in any shape or size as indicated or directed and inclusive of one coat of aluminium primer,one under coat and one finishing coat of aluminium paint for for repair /repalcement of portion of existing ladderat OHT as per existing specification / frame /cover for valve chamber etc complete all as specified and as directed |
| 67 | M & L forDismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m |
| 68 | M&L for PCC 1:3:6 type C120 mm graded aggregate in coping of pole completeincluding demolition of existing PCC copping complete all as specified and as directed |
| 69 | S & F in replacement out door typeWeatherproofLED display board /LED scrolling display boardfully customized as per the Applications for displaying the notice /Alarmwith necessary fixing arrangement on wall complete of following specificationall as specified and as directed Note: Number of boards as per site requirementsModule Resolution : not less than 16 x 32 pixelConnectivity : Pen Drive, Wi-Fi, RS232, RS485, EthernetDisplay Function : notice / Graphics, AnimationPixel Pitch : not less than 10mm |
| 70 | Supply, fabricating, installation, in replacementself illumnatedacrylic LED Sig Board factory made withfixed on wall /iron frame as directedLetter Length30 cm max up to 40 cm Letter Thickness5 cm max up to6 cmCustomized Design of letters back-lit signage including embedding the signage baord firmly with the wall/ MS Angle frame/as per approved Art work and nomenclature as given below :- Note: Nomenclatureof sign board include letters/Logos etc complete as directed. |
| 71 | Box with frame :- 25 x 25 mm square pipe (18 G) frame with cross supports @ spacing not exceeding 1.0 m on the box length including 20 mm x 20 mm MS Square pipe (18 G) stifferenrs duly white enamel painted in 2 coats over a coat of zinc oxide iron primer, depth of box should not be less than 165 mm,Side, Top, Back and bottom Panels :- Made out of 24 gauge chemically treated GI Sheets duly precoated / powder coated with white MATT finish coating on both inner and outer surface. Top panel to have 24 guage precoated drip cap (fixed with pop rivet or machine moulded to shape) of 25 mm on front and side to prevent damages due to rain etc.The bottom panel should be provided with access door fixed with ss screws and suitable housing for LED drivers.LED Module :-LED 12V Module beam angle >=150 degrees with IP rating >= 64, 0.72 W/70 Lumens per module of 3 LEDs with 7000 to 8000 K colour temperature, Make : Tridonic/ Osram / Cree / GELED configuration :- 29 LED Modules per Sq mt (Equal division on spacing based on height of box) and one module every 0.20 m on running length of box.LED power supply :-Input 230 V AC, power supply should be CPCC (Constant power constant current) of 30W/60W/120 W each. Graphics :-Graphics shall be computer plotter cut with translucent cast vinyl matching the colour specification of the installation. |
| 72 | S & F junction box made from SMC/FRP sheet ready made of size Junction boxof size295x195x100 mm with aluminium bus bar of 100Amp capacity for RYB andhalf for neutral made in suitablesize fixed inside the junction box with necessary supporting insulators fixed on hylem sheet ,MS sheet steel fixed inside the bottom portion of box to connect the cable gland complete , entire assemblyfixed to pole /Wall with MS clamp 25 X 5 mm and nuts & bolts,including MCB SP 6 Amp 10 KA 240 V - 1 No, with necessary sizecopper lugs for connecting cables from junction box to fittings complete all as directed by Engineer-in-Charge . Make: Sintex (right hinged) |
| 73 | M & L forMild steel plates, plain or chequered, 5mm thick or over in thicknessFe 410-W (Gde-E- 250) quality-Acomplete all as directed |
| 74 | M & L forpaitingon newMild steel plates, plain or chequered along with two coat ofpriming with red oxide and one finishing coat of synthetivc enamal paintt by using Spray painting /Mannually applying complete all as directed |
| 75 | M & L for preperation of old painted surface of on Mild steel plates, plain or chequered plate cable protection cover /stell surfaces of cross arm / support frameand apply new coating along with two coat ofpriming with red oxide and one finishing coat of synthetivc enamal paint by using Spray painting /Mannually applying complete all as directed |
| 76 | S & F cable 3 corePVC insulated unsheathed multistranded copper conductor of sie 2.5 Sq mm in replacementpassing through PVC conduit from junction box to fitting complete all as directed by Engineer-in-Charge. (Note: PVC conduit is measured and paid seperately) Make: Finolex/Poly Cab/Havell\"s/KEI |
| 77 | S & F cable 3 corePVC insulated unsheathed multistranded copper conductor of sie 4.0 Sq mm in replacementpassing through PVC conduit from junction box to fitting complete all as directed byEngineer-in-Charge. (for street lights/ flood ligts) Make: Finolex/Poly Cab/Havell\"s/KEINote: PVC conduit is measured and paid seperately. |
| 78 | S & F rigid PVC non metalic conduit 20mm diaonpole with ,polesclamps ,nuts & bolts, / wall with saddleswith necessary bend Elbow ,couplers ,check nutsconnected to junction box to fitting etc in replacement complete all as directed by Engineer-in-Charge including painting to clamps. Make: Precision Finolex/Prestoplast/Modi. |
| 79 | Excavation in trenches not exceeding 1.5 metre wide and not exc 1.5 metre in depth for foundation of pole / stay, or cable trenches and getting out in hand / soft disintegratedrock complete all as specified and as directed by the Engineer in charge |
| 80 | Returning filling in incl spreading, leveling watering and well ramming in layers not exceeding 25 cm in soft loose soil complete all as specified and as directed by the Engineer in charge |
| 81 | Removing excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point all as specified and as directed by the engineer –in- charge. |
| 82 | Supply and laying double walled corrugated (DWC) HDPE duct pipe of size 50 mmOuter Dia conformingto IS, approved colour complete with fittings for cable protection.Note: Theinner /Outer dia of Pipes may varies asper Make Approval /Market availabilitycontractor has to supply the size of pipe not less than menstioned below) |
| 83 | M & L XLPE insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 Volts grade, in trenches/fixed on wall for following size complete. |
| 84 | 25 Sq mm 3.5 Core |
| 85 | 16 Sq mm 4.0 Core |
| 86 | 10 Sq mm 4.0 Core |
| 87 | M & L for lifting , and Relaying the existing PVC insulated, armoured, heavy duty electric cable with aluminimum conductor, 1100 Volts grade, in in trenches/fixed on wall of following cross- sectional areaNote- (i) Earth work /DWC pipe for cable protection shall be measured & paid seprately.ii) Rate include the cost of lugs of suitable size ,andcable gland irespective of length of cable etc . |
| 88 | Cable of size from35sq mm to 70sq mm 3.5 / 4 core |
| 89 | Cable of size from 10sq mm to 25sq mm 2/3.5 / 4 core |
| 90 | Supply and fixfire retardant insulated syntheticmatforLT , 1100 Voltof 2.0 mm thick+/- 10% conforming to IS , tested for breakdown strength, ageing properties, insulation resistance, effect of acid,Alkaline, Diesel & transformer oil ,leakage current test,fire testetchaving the width of 1000mm +/-20mm complete as required sutable and using adhasive and alied chemical and scaling of all part s of all joints and border ends and fixingtape making good as paste near LT panel boards complete all as specified and as directed.Make: Vardhaman/Jyothi/Cease fire/Qquivalent |
| 91 | Note: An amount of Rs 29880.00 on account of Credit Schedule for Schedule A Part II shall be deducted from the total amount of BOQ to arrive at Contract Sum. |