| 1 | B/R Portion Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles |
| 2 | Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing derviceable tiles to store and rubbish of the premises |
| 3 | Demolition of cement concrete (Reinforced) in shelves/ manhole cover not exceeding 15 cm thickness (below or above ground floor) |
| 4 | Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground GL) as in plinth protection/ hard standing/ floors/ path etc |
| 5 | Taking down chowkat or frames with shutter (without taking off shutters from the frame) exc 1.5 sqm but n.exc 4 Sqm |
| 6 | Taking down chowkat or frames with shutter (without taking off shutters from the frame) not exc 1.5 sqm |
| 7 | Dismantling unservicable /cracked water tanks and removing from sitecapacity exc 500 ltr n.exc 1000 ltr all as spd |
| 8 | Taking up or down steel tubing for 25mm dia pipe and connections including cleaning for re-fixing or removal to store.all as spd and directed by Engg-in-Charge |
| 9 | Taking up or down steel tubing for 20mm dia pipe and connections including cleaning for re-fixing or removal to store.all as spd and directed by Engg-in-Charge |
| 10 | Taking down cement plaster on brick or stone walls etc, incl raking out joints, hacking for key scrubbing down with water, etc. |
| 11 | M & L forroof surface must be pressure-washed with water with, is to be used to and/ or remove all dirt, dust, chalking and waste products. Remove algae, mold by using bleach solution. 2 tiles joint repair all visible and joint more than 0.50mm and not giving hollow sound, on the tiles roof or at the junctions of flat roof & vertical parapet wall, pipe joints, should be cut and widen v shape with mechanical cutter in the size (6mm W x 6mm D) and fill with Dr. Fixit PMM methodology.Glass fiber apply Dr Fixit URP or Primeseal A on the well prepared groove, allow to cure tack free. Followed by filling all the joints covering the entire area uniformly with suitable chemical. Allow chemical to cure a minimum 24 hours. Apply minimum 50mm-100mm width 45 GMS glass Fibre mesh/ non-woven geo testile fleece with the coat of Dr Fixit Roofseal classic along the length of crack when the 1st coat is still in wet condition. Apply the second coat with an interval if 4-6 hours. Waterproofing: Apply a coat of Dr Fixit Roofseal classic (diluted with water in the ratio 2:1) as Self Priming 14.0-18.0 Sq. mt/litre.Allow coating to dry for 3-4 hours. Applt two coats of Dr Fixit Roofseal classic/litre/coat, without, the rate of application being the same for both the coats. This would ensure correct consumption of material that will deliver a total of DFT of microns. Allow the system to air cure for 5 days minimum. Check to see no void surface is left untreated/uncoated. The material having following technical specification as per ASTM D 6083 M- type II, Attains a Tensile strength of 2.5 N/mm2confirming to ASTM D 2370: Elongation at break > 300% confirming ASTM D 2370, Adhesion to Concrete 2.0N/mm2 Confirming ASTM D 4541 and crack bridging ability up to 2mm, air cure the coating for 7 days before water pound test for 48 Hrs. The system comes with 7 year waterproofing warranty from service provider. For vertical surface : Apply 2 coat of Dr Fixit Roofseal classic with forced coverage of /litre/coat. Entire terrace should be coated with roofseal classic alongwith parapet walls needs to be enveloped with roofseal classic/Raincoat system. The total 3 coats treatment |
| 12 | M&L for brick work using sub class ‘B’ old size bricks, straight or curved on plan exceeding6m mean radius, built in CM (1:6) complete al as specified |
| 13 | M&L for brick work using sub class ‘B’ old size bricks, straight or curved on plan to any radius in half brick thick wall built in CM (1:6) complete al as specified |
| 14 | M&L for rendering 15 mm thickreadymade plaster on inner/outer walls by adding 17-19% of potable water by weight of material for thickness above 15mm it is recommended to be applied in multiple layers. ready mix plaster shall complies with IS 1661-1972, IS 2250-1965, IS 2402-1963 and confirms the compressive strength @ 28 days 10-12 Mpa/Bulk density 1500-1600 Kg/m3. (Note : The rate quoted by contractor shall include cleaning of surface, application as per instruction and scaffolding upto 20 Mtr ht all as specified and directed) |
| 15 | M&L rendering 5 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:3 as in ceiling incl finished even and smooth (without using extra cement). |
| 16 | M&L 300x450x7mm thick glazed ceramic digital tilescoloured incl ,design and pattern as approved fixed as in vertical surface etc, set and jointed in neat cement slurry and pointed with white cement with colour pigment to match incl rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 complete all as specified and directed. |
| 17 | M&Lcolour non skid ceramic tiles 7 to 8 mm thick ( square/ rectangular) area of each tiles exc. 0.11 sqm but n.exc. 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white cement with colour pigment incl 15mm thick screed bed in CM 1:6 complete all as spd |
| 18 | M & L for 20mm thick granite (of any type) machine cut as in skirting , dado, urinal partition etc and jointed with grey cement slurry and pointedwith white cement with admixture of pigments to match the shade of granite incl grinding and polishing complete |
| 19 | M&L for 75 mm thick, PCC 1:3:6 type C2 finished even and smooth without using extra cement.as in plinth protection incl joints filling complete all as specified. |
| 20 | Factory made single extruded WPC (wood polymer Composite) solid door/ window/ Ceosetory window & other Frames/ Chowkhat of size 45 x 70 mm comprising ofPVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wwod powder/ rick husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms ) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded stat headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N / mm 2 and resistance to spread of flame of Class A catogory with property of being termite/ borer proof, water / moisture proof and fire retardant and fixed in position with MS hold fast/lugs / SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). |
| 21 | Factory made single extruded WPC (wood polymer Composite) solid plain flush door shutter of 35 mm thickcomprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/ cum and screw withdrwal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N mm2 modulus of elasticity 850 N / mm2 and resistance to spread of flame of Class A catogary with property of being termite/ borer proof, water/ moisture proof and fire retardanat and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, all as per direction of Engineer-In-Charge (Note:- stainless steel butt hinges and necessary SS screws shall be paid separately. |
| 22 | S&F Butt hinges 100mm mild steel cold rolled, medium weight. |
| 23 | S&F 150mm long aluminium, anodized barrel tower bolts of extruded section |
| 24 | S&F 100mm long aluminium anodized handles of extruded section |
| 25 | S&F 300mm aluminium alloy, anodized, sliding door bolts with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy |
| 26 | S& Fin repair vitreous China squatting pan, ‘Orissa’pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) including P or S trap complete all as specified |
| 27 | S&F in repairs 10 ltr capacity PVC Low level flushing cistern including 32mm dia PVC flush pipe, fixing in position with PVC connection pipe of 15mm x 600mm long etc complete. |
| 28 | Supply and fixingin repair wash hand basin vitreous Chinatable top type any sizeincluding cutting hole and pinning in ends of brackets or erecting stand with fixing 32mm dia waste coupling brass chromium plated suitable for wash basinand PVC waste pipe all as spd and directed . |
| 29 | S & F in repairs Vitreous China urinal half stallwhite (minimum), with grating and union for discharge pipe, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistren with brackets brackets flush pipe, grating and union for discharge pipe in repairs complete all as specified and as directed. |
| 30 | Supply and fixingin repair 15mm dia long body bib tap fancy type chromium plsted with crutch or butter fly handle screwed down screwed for Iron pipe or brass ferrule and fixed. |
| 31 | S & F in repairs 15mm bore fancy type pillar taps cast copper alloy with capstan head chromuim plated screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipecomplete all as specified |
| 32 | Supply and fixingin repair Angle valve cast copper alloy cromium Plated (CP)15mm dia screwed down high pressure with crutch or butter fly handles screwed both and iron pipe or forunions and fixed |
| 33 | Cutting chases, forwater tubing or concealed , etc, and making good to facings where required and plastering in cement mortar (1:3)cutting not exceeding 10cm girth in brick walls complete all as specified and directed. |
| 34 | S&F GI water tubing of 15mm dia ,medium grade conforming to IS-1239(Part -1) including all fittings such as bends,tees, short pieces, connectors, elbows, reducers, union dockets etc & fixed to walls,ceilings, & laid on floors complete all as specified and directed. |
| 35 | Fixing onlyGI water tubing of 15mm dia ,medium grade conforming to IS-1239 (Part -1) including all fittings such as bends,tees,short pieces, connectors, elbows, reducers,union dockets etc & fixed to walls,ceilings, & laid on floors complete all as specified and directed. |
| 36 | S&F GI water tubing of 20 mm dia ,medium grade conforming to IS-1239(Part -1) including all fittings such as bends,tees,short pieces, connectors, elbows, reducers, union dockets etc & fixed to walls,ceilings, & laid on floors complete all as specified and directed. |
| 37 | Fixing onlyGI water tubing of 20 mm dia ,medium grade conforming to IS-1239 (Part -1) including all fittings such as bends,tees,short pieces, connectors, elbows, reducers, union dockets etc & fixed to walls,ceilings, & laid on floors complete all as specified and directed. |
| 38 | S&F in repair 5.8 mm thickbeveled edges mirror of selected quality glass of modi guard, Atul, mounted on 6mm thick AC building board or commercial plywood including PVC frame |
| 39 | S&F in repairs aluminium anodisedtubular towel rail, 20mm dia ‘D’ type, 60CM long between flanges. |
| 40 | Supply and fixing in repair 15mm dia 600mm long PVC connection with PTMT nut and washer complete |
| 41 | S&F in repairs CP Soap dish 150mm, fixed to wall with chromium plated brass screws complete all as specified |
| 42 | S & F 12mm thicktempered glassurinal partition with steel frame including all cuts & holes for fixing in size & design as approved by GE complete all as specified |
| 43 | S & F stainless towel ring complete all as specified & directed |
| 44 | M & L Type B11:2:4 (20mm graded aggregate)for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the likecomplete all as specified and directed |
| 45 | S&F mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (anealed) not less than 0.9 mm dia or securing with clips. |
| 46 | Formwork to rough finished surface of concrete soffits and sides of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) |
| 47 | Supply and fixingRotational moulded polythene water storage tanks (cylindered vertical closed top ) hoisted and fixed in position all as spd in SSR Part –I of capacity of tanks 1000 ltr |
| 48 | S&F 20 mm bore ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe of brass ferrule and fixed. |
| 49 | S & F 20mm gun metal globe or gate valve wirh iron wheels head screwed both ends for iron pipe |
| 50 | S&F in repair 110mm dia PVC (SWR) pipes single socketed in any length with rubber joints laid in trenches or floor complete. |
| 51 | S&F in repair 110mm dia PVC (SWR) pipes single socketed in any length with rubber joints fixed to walls etc complete. |
| 52 | S&F in repair 75mm dia PVC (SWR) pipes single socketed in any length with rubber joints fixed to walls etc complete. |
| 53 | S&F in repair 75mm dia PVC (SWR) pipes single socketed in any length with rubber joints laid in trenches or floor etc complete. |
| 54 | M&L PVC (SWR) floor trap 75mm dia plain with grating including jointing with solvent cement etc complete, fixed in repair. |
| 55 | S&F in repair PVC (SWR) bends 110mm dia any radius |
| 56 | S&F PVC in repair (SWR) bends 75 mm dia any radius |
| 57 | S&F PVC in repair (SWR) junction single,(Single T) 110mm dia equal or unequalwith access door |
| 58 | S&F PVC in repair (SWR) junction single,(Single T) 75mm dia equal or unequalwith access door |
| 59 | S&F PVC in repair(SWR)vent cowl 110mm bore |
| 60 | M & L complete removal of existing treatment and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal resistance dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new or old surfaces complete all as specified. |
| 61 | M & L for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal resistance dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new or old surfaces complete all as specified. |
| 62 | M&L preparation of newly plastered surfaces of wall and applying two coats ofdistemper oil bound over 1 to 2mm thick birla wall care putty over a coat of alkali resitant primer coat on plastered surface complete all as specified. |
| 63 | M & L for complete removal of existing treatmentof wall and applying two coats of distemper oil bound over 1 to 2mm thick of birla wall care putty including preparation of surfaces complete all as specified |
| 64 | M & L for preparing old surfaces of ceiling and applying two coats of white wash complete all as specified |
| 65 | M & L for preparing new plasteredsurfaces of ceiling and three coats of white wash complete all as specified |
| 66 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in Hard/ Dense soil complete all as specified and directed. |
| 67 | Demolition and breaking up drain pipes 150 mm (salts glazed ware ,AC or Reinforced concrete) set in cement mortar all as specified |
| 68 | M & L 150 mm dia Salt Glazed stone ware drain pipes laid in trenches and jointed as specified complete all as specified and directed. |
| 69 | M & L for PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150mm bore complete all as specified and directed. |
| 70 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and directed. |
| 71 | Removing Excavated soil exceeding 250 M but not exceeding 500 M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed. |
| 72 | M&L for brick work using sub class ‘B’ old size bricks, straight or curved on plan exceeding6m mean radius, built in CM (1:6) complete al as specified |
| 73 | M&L for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed |
| 74 | M & L for providing plain cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate) as in coping, bed block for embedding hold fasts, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed. |
| 75 | M&L for providing precast cement concrete 1:2:4 type B1 (20mm graded aggregate) as in cover slab for manholes complete all as sp[ecified and directed |
| 76 | M/LCement concrete 1:3:6 type C-1 using 20mm graded stone aggregate in surface channels and drains complete. |
| 77 | M/L Cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate in cills, seismic and other similar bands, plinth courses, copings, bed plates, bond stones, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete. |
| 78 | Extra for forming fair finished drain or channel 30 cm inner girth in cement complete all as specified and directed. concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc.All as specified and directed. |
| 79 | M&L 75 mmthick cement concrete 1:4:8 type D-2 finished fair and even as in sub base Complete all as specified and directed. |
| 80 | M & L for 15 mm thick screed bed or bedding layer in CM 1:6 to receive floor finishes complete all as specified and directed. |
| 81 | M&L for chequred cement concrete tiles of size 300x300x25 mm thick coloured rubber pressed glossy finish, set and jointed in neat cement slurry and pointed in white or colour cement and match the surace of tiles as foor/staps, complete as all specified and directed. |
| 82 | Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and directed. |
| 83 | Removing excavated material (soil) to a distance n.exc. 50mtr and depositing where directed at a level n.exc. 1.5m above the starting point complete all as specified and directed. |
| 84 | M&L hardcore of gauge n exc 63mm deposited spread and levelled in layers n exc 15cm thick watered and rammed to a true surface colmplete all as specified and directed. |
| 85 | M&L for cement concrete 1:4:8 (100mm thick) type D-2 (using 40mm graded stone aggregate) as in foundation, filling, mass concrete, sub-base & apron etc complete all as specified and directed. |
| 86 | M&L interlockingtiles 80 mmcoloured rubber pressed glossy finish thickof approved pattern & shadeISI Marked orapproved by GEset jointed over 40 mm th fine sand cushion including sides are tappered 75 mm in width by PCC 1:3:6 type C1 (using 20mm graded crushed stone agg.) complete all as specified and directed. |
| 87 | Excavation over areas n exc 1.5 mtr deep and getting out in hard & densetype of soil complete all as specified and directed. |
| 88 | All as per item No 87but depth exceeding 1.5 mtr and n.exc. 3.00 mtr -ditto- |
| 89 | M&L for cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation, filling & mass concrete complete all as specified and directed. |
| 90 | M&L forRCC M-25 design mix as in footing, foundation beams, plinth beams, bases of columns complete all as specified and directed. |
| 91 | M&L for RCC M-25 design mixas in walls, retaining walls, basement walls, ballast walls and the like of any thickness above top of footing including attached pilasters and buttresses complete all as specified and directed. |
| 92 | Use and waste of form work to sides of concrete foundation, footing, bases of columns, raft and raft beams, sides and soffits of foundation and plinth beams and similar work vertical or to batter, flat, rough finish surface of concrete complete all as specified and directed. |
| 93 | Use and waste of form work to walls, retaining walls, basement walls, ballast walls and the like including attached pilasters and buttresses and similar work vertical or to batter, flat, fair finished surface of concrete complete all as specified and directed. |
| 94 | Removing excavated soil to a distance not exc 50 M, depositing where directed at a level not exc 1.5 metre above the starting point complete all as specified and directed. |
| 95 | Hand packing of broken stone ( any thickness) at back of the retaining wall etc and raising andlowering to required level complete all as specified and directed.Note:- Stone obtained from srl item No 4 shall be used. |
| 96 | Demolition of reinforced cement conc. of any description and in any position including reinforcement cut as required to facilitate demolition complete all as specified and directed. |
| 97 | Dismantling structural steel work including doors, gates but excluding framed truss etc |
| 98 | M&L For Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete |
| 99 | M&L for PCC 1:3:6 type C-2as in foundation, and mass concrete using 40 mm graded stone aggcomplete all as specified.. |
| 100 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete. |
| 101 | M&L for 100 mm thick PCC 1:4:8 Type D-2 using 40mm graded stone agg.complete all as specified |
| 102 | M&L for sand filling under floors or in foundations including watering and consolidation complete all as spd. |
| 103 | M& L For Machine pressed precast concrete interlocking paver block any shape ,size& any Colourconfirming to IS 15658-2006 of 80mm thickness M-40Grade |
| 104 | M&L PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in coppingall as specified and directed. |
| 105 | M & L Pre-cast cement concrete block masonry with solid blocks Type C1 1:3:6 (20mm graded aggregate) exc 10 cm in width and setting in cement mortar 1:4 complete all as specfied. |
| 106 | M&L rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 incuding addition thickness is provided as floating/settng coat complete all as specified ad and directed. |
| 107 | M & L two coat of Synthetic enamel painting on any surface brick, stone, concrete, asbestos cement or plaster surfaces over Priming paints plaster coats incl preparation of New or previously Untreated Surfaces of any description over 10cm girth or width, not otherwise described,complete all as specified & directed. |
| 108 | E/M Portion Taking down carefullyAluminium/copper wiring of any size (for light, fan, socket or power etc complete) ( fittings such as switches, sockets, ceiling roses, pendent holders regulators, tube lights etc to be measured and paid separately) and making good disturbed surfaces of wall, roof etc to match with existing surface complete all as specified and directed. |
| 109 | S & F point wiring for one light point / fan point / bell point / 5 Ampere socket outlet point (independent point), controlled by one, one way switch with 1.50 sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FR-LSH) drawn into and including medium grade PVC conduit concealed (not less than 20 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing suface)and sunk cast ironor pressed steel terminal boxes for mounting fittinglike switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.50 sqmm sizecopper conductor cable as in earth wire and connected to common earth dolly complete all as specified and directed, are as follows :-(a)One light/one fan/one bell point controlled by one, one way switch. |
| 110 | (b)One socket outlet 5 pin 5 Amp controlled by one, one way switch on same board. |
| 111 | (c)One socket outlet 5 pin 5 Amp controlled by one, one way switch on independent board. |
| 112 | S&F switch piano flush type single pole, one way 5 Amp complete all as specified and directed. |
| 113 | S&F socket out letmulti 5 pin, 5 Amps, flush type complete all as specified and directed. |
| 114 | S&F ceiling rose, PVC/ Poly carbonate,isolated body three terminal complete all as specified and directed. |
| 115 | S & F lamp holder angle type PVC/Poly carbonate type insulated body with back plate suitable for batten/wall fitting complete all as specified and directed. |
| 116 | Supply and fix in replacement High quility LED T8 indoor batten tube light 20 Watt with aluminium extrusion in D shaped have large diameter for increased convection heat transferincl one LED PC tube rod and driver,internaly pre wired of 1.5 sqmm twin twisted flexible cableall as specified & directed.NOTE: The contractor must submit 5 years warranty for LED fitiings. |
| 117 | Taking down unservicable MCB and S&FMCB SP,240 volts,AC C curve, 10 KA 6 to 32 Amps . |
| 118 | Taking down unservicable MCB and S&FMCB SPN , 240 volts,AC B curve, 10 KA 40 Amps. |
| 119 | Supply and fixing in replacement LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete. all as specified and directed .NOTE : The contractor must submit 5 years warranty for LED fittings |
| 120 | Taking down unservicable DB and S&F sheet metal enclusure for DBs(double door type)single pole and neutral 8 way including blanking platge as required with 200 Amps rated bus bar, 240 volts fixed complete all as specified and directed . |
| 121 | Supply and fixing in replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with two core flexible copper conductor cable of suitable size complete all as specified and directed. NOTE: The contractor must submit 5 years warranty for LED fittings |
| 122 | S & F in replacement LED bulk head fitting, 1 x 10 watt with PDC aluminium housing and milky diffuser including LED light driver holder, complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230 Volts, 50 Hz complete all as specified and directed. Note: The contractor must submit 5 years warranty for LED fittings |
| 123 | M&L for earthing complete with galvanised steel,earth plate electrode 600x600mm x 6mm thick burried directly in ground verticaly (earth pit not less than 2.25 mtrs belowground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handleto cover, GI protection pipe 15mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed.Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 15mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost. |
| 124 | S& F LED Bulb of 9 watt as specified .NOTE: The contractor must submit 5 years warranty for LED fittings |
| 125 | S&F Exhaustfan metallic bady ISI mark, 300 mm size with louvers including cutting openings, through brick/ stone wall , making of holes and grouting of suitable size of nuts and bolts for 300 mm exhaust fan and making good dismantled portion and making connection with wire of suitable size and connecting accesssories complete all as specified and directed. |
| 126 | Supply, laying and testing in replacement cable XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core. |
| 127 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying ofunderground cable and getting out in any type of soil complete all as directed by the Engineer-in-Charge |
| 128 | Returning, filling in, including spreading,leveling watering and well ramming in layers n.exc 25 cms. thick in soft / loose soil complete all as specified and directed by Engr -in -charge . |
| 129 | Removal of surplus soil not exceeding 50 Mtr and depositing where directs at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed by Engr-in-Charge. |
| 130 | M&L for sand cushioning in trenches spreading and consolidation 8cm thick before laying the cable & 15 cm of sand after laying the cable complete all as specified |
| 131 | M & L galvanised steel water tubing \"light grade\"25 mm bore with all fittings laid under the roads, drains, culverts and fixed on poles etc complete all as specified and directed . |
| 132 | M&L for laying of bricks well burnt sub class \"B\" (old pattern) laid flat for cable protection width equal to the length of brick complete all as specified. |