| 1 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.. In cement mortar. DSR 2023 Item No.-15.7.4 |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge. DSR 2023 Item No.-2.6.1 |
| 3 | Banking excavated earth by mechanical / manual means in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with 1/2 tonne roller, or wooden or steel rammers, and roiling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc, lead upto 50 m and for all lift: DSR 2023 Item No.-2.3.1 |
| 4 | Providing, laying spreading & compacting of granular sub base (GSB) by providing close graded (Fr-1) materials, sprading in uniform layers with Mortor Graded on prepared surface, mixing by mix I n placed method with Rotovater at OMC and compacting with in layers with smooth wheeled Vibratory Roller to achieve the desired density, complete as per MoR &H clause 401& as directed by Engineer Incharge including all machine charges & including all labour, T& P etc req for proper completion of work. Analysis rate |
| 5 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources). DSR 2023 Item No.- 4.1.8 |
| 6 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). DSR 2023 Item No.-5.1.2 |
| 7 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). DSR 2023 Item No.-5.3 |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete DSR 2023 Item No.-5.9.1 |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform DSR 2023 Item No.-5.9.3 |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers DSR 2023 Item No.-5.9.5 |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts DSR 2023 Item No.-5.9.6 |
| 12 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) DSR 2023 I.NO 6.1.1 |
| 13 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) DSR 2023 Item No.-6.4.1 |
| 14 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) dsr 2023 i.no 13.4.1 |
| 15 | 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) dsr i.no 4.1.3 |
| 16 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 17 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats. dsr 2023 i.no 13.83.2 |
| 18 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work. dsr 2023 i.no 13.61.1 |
| 19 | Cartage of dismentled material 5km distance UPPWDSOR 2023-24 S.NO 3 page .no. 16A |
| 20 | Neat cement punning dsr 2023 i.no 13.18 |
| 21 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. DSR 2023-24 I.NO 5.22A.6 |
| 22 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). DSR 2023 Item No.-10.28 |
| 23 | Stone tile work for wall lining upto 10 m height with special adhesive over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement with an admixture of pigment to match the stone shade. Granite stone of any colour and shade. DSR 2023 Item No.-7.38.1.1 |
| 24 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. DSR 2023 Item No.-11.55.1 |
| 25 | Providing and fixing carbon steel galvanised (minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 10 x 80 mm DSR 2023 Item No.-10.27.1 |
| 26 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. DSR 2023 Item No.-10.18 |
| 27 | S/F ceiling fan all complte as directer by e/I. Sanction Rate |
| 28 | Suppy and instalation of Swing 2 seater item Code No SW-02 (make by royal Amusements) or equivalent quality as directed by E/I . MR |
| 29 | Supply and fixing R.C.C. sleeper/batton moulded bench, required as per direction of Engg I/C. Including fixing with necessary nuts and bolts in proper possition. (Analysis rate) (park 1=5no.)park 2=4no. chair |
| 30 | Supply of Solar AIO Single piece High pressure Die cast (LM6 Alloy) 17W Aluminium housing appearance of Solar AIO shall be traditional Street Light, IP65 & IK08, suitable for OD 50/60mm bracket, having Min 3000 lumens, suitable for 24hrs (2 Nights) Autonomy and its backup calculation sheet shall be approved by Consultant Dimming Profile :• From Dusk – First 05hours sensor enabled with 30% brightness level• Next 05Hours sensor disabled and fixed at 30% Brightness level• Next 2hours/dawn- Sensor enabled with 30% brightness levelLithium pherrophosphate Battery capacity min [email protected] or 256 watt hour & shall be of fresh manufactured battery (Not re-used cells) Battery Temp range -20-+60℃ and panel capacity min 35Wp, CRI >=70, Efficacy Min >175lm/W is MUST, system wattage should not be more than 17W ± 5%, if wattages increases then the size of battery & panel shall also be increased in similar percentage to maintain equal autonomy of the system. Life class of LED System 50000hrs@L70, LED Make - CREE/ NICHIA/ LUMILEDS /OSRAM. CE Certified, charger efficiency >90% and standards IEC62109-1, IEC61547, CISPR15, IEC62093, IEC61347-2-13, EN50530, IEC62384 The PV module should be made up of crystalline silicon solar cells \"Mono-Crystalline\" and must have a certificate of testing conforming to IEC 61215 Edition II / BIS 14286 & IEC 61730-1,2 IEC60598, Operating temp 0 Degree C to 50 Degree C, certifying above given prameters all reports shall be from In-house NABL or IECQ or any international accredited Laboratory, Complete luminaire /battery/panel/charge controller must be BIS accredited (If applicable) and as per UPPWD Approved Product List. With five yeart warrenty |
| 31 | Supply & fixing of 10m GI Octagonal Pole of approved make (top dia 100mm, bottom dia 200mm and base plate 16mm thick) having 3mm thickness with single arm bracket (1m length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and required T&P complete in all respect.pwd sor is no 650 |
| 32 | Supply and fixing of factory wired integral LED flood light luminaries with die cast aluminium housing built with dirver set suitable for 120 watt. Confirming to IP-66 protection complete in all repect. PWD SOR 2017-18 S.I. No. 1453 CAT-AAA |
| 33 | Supply and fixing of 4 sqmm 2 core flat twin \"AL\" cable Mtr complete with labour T&P an dall taxes as per direction by E/I. |
| 34 | Making grooves 10 to 12 mm wide x 8mm deep in plaster of the walls or in ceiling vertically orhorizontally as required. |
| 35 | Providing and fixing PVC pipe conforming to IS make working pressure 6 Kg/SqCm incuding testing labour T&P and all complete fittings110mm dia. |
| 36 | Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside,GP Box, piano type switch & ceiling rose/angle/batten holder on 3mm thick phenolic laminated backalite sheet etc complete in all respect as directed including matching colour wash. SI No. 138 C |
| 37 | Wiring point for fan / fresh air fan (light duty exhaust fan) with 1.5 sq.mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside,GP Box , piano type switch & ceiling rose on 3 mm. thick backelite sheet etc., complete in all respect includingmatching colour wash. SI No. 140 C |
| 38 | Add for light / fan points with modular type switch in place of piano type switch. SI No. 187 A |
| 39 | Wiring point for plug with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit. and piano type switch and socket etc., complete in all respect including matching colour wash. SI No. 141 C |
| 40 | Supply and fixing of power plug with 20 Amp./250 volt flush type modular switch and 5 pin 20 A/250 volt flush type universal modular socket switch on concealed M.S box including supply ofall material, labour T&P etc. required for proper completion of work. SI No. 1139 A |
| 41 | Supply and fixing of electronic fan regulator( Modular) 120-280 V. ISI marked, on the existing switch board including making connections, required material, labour T&P etc. for proper completion of work to the satisfaction of Engineer in charge of work. SI No. 1203 C |
| 42 | Supply and fixing of LED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light onsurface complete in all respect. SI No. 1413 A Cat AAA |
| 43 | Supply and wiring of submain with two number 2.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2mm thick) PVC conduit partly laid in slab alongwith reinforcement before concreting and partly concealed in wall, with 1 nos. 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable as earth continuity wire drawn inside the conduit etc, complete in all respects includingmatching colour wash. SI No. 1307 C |
| 44 | Supply and wiring of submain with two number 4 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2 mm thick) PVC conduit partly concealed in wall and partly laid in slab alongwith reinforcement before concreting, with one no. 2.5 sq. mm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit. including matching colour wash etc. complete in all respect. SINo. 221 C |
| 45 | Supply and laying of 10 sqmm 2 core aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer- Incharge, complete in all respect. The armouring of the cable shall be properly connected with theearth conductor by clamps etc. . SI No. 501 b |
| 46 | S & F surface/Flush mounting 12 ways SPN distribution board with additional metal door withoutMCB complete in all respect, as Direct by Engineer in Charge. SI No. 1025 A Cat A |
| 47 | S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve SI No. 1002 Cat A |
| 48 | S&F of 6 Amp. to 32 Amp. DP MCB (10 KA) C Curve. SI No. 1009 Cat A |
| 49 | S/F exsust fan 300mm all complte as directer by e/i Please Enable Macros to View BoQ information |