| 1 | Taking down old exhaust fan of any size/ make from existing location, sealing cable end, and removing fan and deposited to MES store yard with and including arrangment of suitable transportation complete all as specified and as directed by Engineer-in-Charge.Note:-(i) Exhaust fan to be deposited in good condition i.e. without any external damage. (ii) Penalty @ Rs. 500 per fan shall be imposed if external damage found on exhaust fan. |
| 2 | Supply and fixing anti-bacterial type modular Switch, one way, 6 Amps, one module, 230 volts, single pole complete all as specified and as directed. |
| 3 | Supply and fixing anti-bacterial modular Socket outlet, 2 in 1, 2/3 pin, 6 Amps, two module, 230 volts complete all as specified and as directed. |
| 4 | Material & labour for Sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor FRLSH cable of size 1.50 sqmm, 1100V grade, down through and including adequate sizes PVC non-metallic conduit of 20 mm/ appropriate dia with accessories and fittings and one run of 1.50 sqmm single core, multi stranded copper conductor FRLSH cable as earth continuity conductor complete all as specified and directed by Engineer-in-Charge. |
| 5 | M&L for Sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor FRLSH cable of size 10.0 sqmm, 1100V grade, down through and including adequate sizes PVC non-metallic conduit of 25 mm/ appropriate dia with accessories and fittings and one run of 10.0 sqmm single core, multi stranded copper conductor FRLSH cable as earth continuity conductor complete all as specified and directed by Engineer-in-Charge. |
| 6 | Notefor Srl item No. 4.00 & 5.00(a)Two runs of cable, one run of earth wire and one run of PVC non-metallic conduit shall be measured as one unit length.(b) Cable required for connection to DBs shall deemed to be incl and shall not be measured separately.(c) Earth wire shall run inside the conduit pipe complete all as specified.(d) Cutting chases and making good surfaces to match with existing to be measured paid and separately in relevant item of this schedule. |
| 7 | S&F powder coated sheet metal encloser for MCB distribution board, SPN, 8 Way, Double door, phosphatised with rated bus-bar 200 Amp, neutral link, earth bar and din rail, cable ties for cable management, 240 V, complete all as specified and as directed by Engineer-in-Charge. |
| 8 | Supply & fixing MCB, 32 Amps, SPN, \"C\" series, breaking capacity 10 kA, 240V complete all as specified and as directed by Engineer-in-Charge. |
| 9 | Supply & fixing MCB, 6 to 32 Amps, SP, \"B\" series, breaking capacity 10 kA complete all as specified and as directed by Engineer-in-Charge. |
| 10 | Supply & fixing In line duct fan made of ABS plastic body connected to the duct and installing the fan unit, fan size 100 mm, rated voltage 230V, frequency 50 Hz, air flow 450 m3/h, 2450 RPM complete all as specified and asdirected by Engineer-in-Charge. |
| 11 | Supply & fixing In line duct fanmade of ABS plastic body connected to the duct and installing the fan unit, fan size 150 mm, rated voltage 230V, frequency 50 Hz, air flow 500 m3/h, 2600 RPM complete all as specified and directed by Engineer-in-Charge. |
| 12 | Supply & fixing In line duct fanmade of ABS plastic body connected to the duct and installing the fan unit, fan size 200 mm, rated voltage 230V, frequency 50 Hz, air flow 850 m3/h, 2500 RPM complete all as specified and directed by Engineer-in-Charge. |
| 13 | Supply and fixing Disc Diffuser with protection grill of size 100 mm complete with necessary fittings/ fixtures complete all as specified and as directed by Engineer-in-Charge. |
| 14 | Supply and fixing Disc Diffuser with protection grill of size 150 mm complete with necessary fittings/ fixtures complete all as specified and as directed by Engineer-in-Charge. |
| 15 | Supply and fixing Disc Diffuser with protection grill of size 200 mm complete with necessary fittings/ fixtures complete all as specified and as directed by Engineer-in-Charge. |
| 16 | Supply & Fixing of in line PVC duct pipe of size 100 mm bore with with all accessories such as Tees, Bends, Elbows, junction, reducers, connector, clamps etc., complete all as specified and as directed by Engineer-in-Charge. |
| 17 | Supply & Fixing of in line PVC duct pipe of size 150 mm bore with with all accessories such as Tees, Bends, Elbows, junction, reducers, connector, clamps etc., complete all as specified and as directed by Engineer-in-Charge. |
| 18 | Supply & Fixing of in line PVC duct pipe of size 200 mm bore with with all accessories such as Tees, Bends, Elbows, junction, reducers, connector, clamps etc., complete all as specified and as directed by Engineer-in-Charge. |
| 19 | Material and Labour for Cutting hole for air ducting of exhaust system in circle/ square shape as per site requirement, into or through bricks/ concrete walls built in cement mortar of superficial area suitable for 100 to 200 mm vent exhaust fan including making good of disturbed surface area in cement mortar 1:3 or cement concrete 1:2:4, type B-l and cover hole as required complete all as specified and as directed by Engineer-in-Charge. |
| 20 | M&L for Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; forconcealed conduit wiring etc., and making good, cutting not exceeding 10 cm girth etc., complete all as specified and as directed by Engineer-in-Charge. |