| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 12-12-2025 | corrigendum 01 | BOQ | 23-12-2025 |
| Sl. No. | Item Description |
| 1 | Attending complaints for checking of existing electrical points wiringin any Buildings/Pole for continuity ,no light including carrying out minor repairs etc as required to make the item functional and replacing burnt wire ends, small pieces of wire, tightning of loose connections etc all as specified. Note - Contractor has to deploy Qualified Electrician and Helper with all necessary tools on all days to the complaint cell and complaints will be attended on the same day itself. Recovery for non attending complaints will be three times rate quoted by the Contractor. |
| 2 | Dismantling and taking down the existing defective street light/security light fitting of any type and any capacity fixed at any height by replacing UNSV part including perpex cover checking loose connection etc, restroration of electric supply, detecting and repair of UG cable fault whenever required round the clock all as directed at site on daily complaint basis. |
| 3 | S&Fin repairs 45 watt of new street light/security light incl making electric connection using two run of 1.5 sqmm single core unarmoured wire from junction boxcomplete all as specified and directed by Engr-in-Charge. |
| 4 | S&Fin repairs 60 watt of new street light/security light incl making electric connection using two run of 1.5 sqmm single core unarmoured wire from junction boxcomplete all as specified and directed by Engr-in-Charge. |
| 5 | S&Fin repairs 100 watt of new street light/security light incl making electric connection using two run of 2.5 sqmm single core unarmoured wire from junction boxcomplete all as specified and directed by Engr-in-Charge. |
| 6 | S&FIndus series Powder coated pressure die cast alluminium compact high power LED floodlight/security lightfittings with heat resistant toughned glass with lense having90 Watt including making electric connections using two run of 2.5 sqmm single core unarmoured wire from junction box, fixed in repairs,CA No also engaved on street light complete all as specified and as directed by Engr-in-Charge. |
| 7 | Material and labour for repair to existing LED street light fitting 45 Watt to 60Watt of any make including supply and replacement of driver and other minor allied items required at site to make the light fitting serviceable complete all as specified and directed by Engineer-in-Charge. |
| 8 | Material and labour for repair to existing LED street light fitting 90 Watt to 100Watt of any make including supply and replacement of driver and other minor allied items required at site to make the light fitting serviceable complete all as specified and directed by Engineer-in-Charge. |
| 9 | Material and labour for repair to existing LED Floodlight fitting 100 Watt of any make including supply and replacement of driver and other minor allied items required at site to make the light fitting serviceable complete all as specified and directed by Engineer-in-Charge. |
| 10 | S&FSub main wiring with two single core PVC insulated unshesthed cable copper conductor(FRLS-H) of size 2.5 sqmm multistrandedand one run of 2.5 sqmm PVC insulated unsheathed copper conductor(FRLSH) as earth continuty conductor drawing in and including non-metalic PVC rigid conduit 25mm dia ISI marked with all conduit accessories concealed in wall, cutting of chases in walls, floors, ceilings, beams etc and making good the disturbed surfaces as directed including taking down old unservicable wiring complete all as specified and directed. (Two run of single core cable and one run of earthing cableand one run of PVC conduit shall be measured as one length.) |
| 11 | Supply and fixing in repairs Rigid non-metallic PVC conduit 25mm dia (Heavy duty)in concealed exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. including taking out old conduit complete all as specified and directed. |
| 12 | S&F PVC insulated sheathed service wiretwin core 6 Sqmm aluminium solid conductor 1100 volts grade incl taking down old unserviceable one. |
| 13 | S&F PVC insulated sheathed service wiretwin core 10 Sqmm aluminium solid conductor 1100 volts grade incl taking down old unserviceable one. |
| 14 | Supply and fixing in repairs MCCB 320amps 4 pole 36 KA with adjustablethermal and fixed magnetic setting, including taking down old UNSV one complete all as specified and directed. |
| 15 | Supply and fixing in repairs MCCB 200amps 4 pole 25 KA with adjustablethermal and fixed magnetic setting, including taking down old UNSV one complete all as specified and directed. |
| 16 | Supply and fixingMCCB 160amps 4 pole 25 KAadjustablethermal and fixed magnetic setting,complete all as specified and directed. |
| 17 | Supply and fixingMCCB 40 Amp to 100 ampsfour pole C curve 25 KA including taking dwon old UNSV one complete all as specified and directed. |
| 18 | Supply and fixingMCB single pole 06 amp to 32amps C curve25 KA with sheet metal encloser, including taking dwon old UNSV one complete all as specified and directed. |
| 19 | Preparation of old painted surface of 9 m steel tubular poles above the top of PCC coping.Painting of pole from top of coping to a height of 1.5m (bottom portion of pole) with two coats of synthetic enamel paint in black and yellow alternate strip and painting the rest portion of pole of (approx length 7 m)including painting of cross arms/clamps/GI pipe breaket etc complete with two coats of synthetic enamel aluminium paint and to the entiresatisfaction of Engineer-in-Charge complete all as specified and directed |
| 20 | M & L for preparation of old cement based painted surfaces of RCC pole 9 m by cleaning of depositedmaterials,and painting withone coat of exterior emulsion weather coat paint of approved make and colour including painting of cross arms/clamps/GI pipe breaket etc complete all as specified and directed byEngineer-in-Charge |
| 21 | S & F in repairs LT cable joining kitstraight through heat shrinkable complete with jointing materials suitable for LT armoured cable 4 core of size 16 to 35 Sqmm all as directed |
| 22 | S &F in repairs LT cable joining kitstraight through heat shrinkable complete with jointing materials suitable for LT armoured cable 4 core of size 50 to 95 Sqmm all as directed |
| 23 | M&L for repair any size of LT panel of panel door, hinged, nut-bolts clamp and welding and fabrication work as required including Painting of paneletc complete with two coats existing paint complete all as specified and directed |
| 24 | Disconnecting / taking down carefully existing unserviceable LT panel board / feeder pillar boxany type and capacity including all control switches, fitting and fixtures from different location as directed by the Engr-in-Charge. |
| 25 | Supply, installation , commissioning and testing LT feeder pillar boxin replacement of suitable size,outdoor cubical type floor mounted factory madeof CPRI approved factory, totally enclosed vermin proof with front and rear opening with IP-54 protection as per IS - 8623 duly powder coated , fabricated out of 2.0 mm thick mild steel sheet mounted on frame of mild steel angle iron 60 cm x 60 cm x 6mm and , 45 cm aboveground level duly supported with mild steel angle iron struts 60 cm x 60 cm x 6mm thick and embedded in PCC foundation inPCC 1:2:4, type B-1 , using 20 mm graded crushed stone aggregate , with suitable 415 Volt, 3 phase, four wirecopper bus bar of rating capacity 400 Amps duly drilled holes for connections, R-Y-B-N insulated with different colour code and sleeved mounted on insulators complete prewired and cable connection with copper conductor wire upto Aluminium bus bars including all incoming and outgoing cable connections with suitable size of copper lugs/ glandincluding supply and fixing of MCCB four pole, 415V,I/C- 250 Amp. 25KA-01No Outgoing 63 Amp 4 pole- 02 Nos, 32 Amp SPN-02 Nos. including taking out old unserviceable, complete all as specified and directed by Engr - in- Charge. |
| 26 | Supply, installation, testing and commissioning of LT panel outdoor type, CPRI approved, suitable forLT 440 volts, 50 Hz, 3 Phase 4 wire supply system, double door type factory fabricated having independant cabin including locking arrangement for each MCCB , weather and vermin proof (Protection class IP-55), made out of 3.15 mm thick MS CRCA sheet with front and back opening doors duly hinged upto full door height with special steel hinges, rubber lining, bakelite sheet, locking arrangements, on both side of the doors, powder coated internally and externally, CRCA sheet for panel shall be mounted on 50 mm x 50 mm x 5 mm angle iron frame and shall have channel base of appropriate size and mounted on PCC foundation built in PCC 1:3:6 type C-2 be using 40 mm graded crushed stone aggregate including earhwork complete , as recommended by manufacturer but height not less than 30 cm above ground level, suitable for and comprising the following , complete all as specified and directed by Engr - in - charge. (Location : Sashithar Near Power House) |
| 27 | Incoming :(a) Bus bar chamber comprising 4 Nos copper strip bus bars PVC insulated made of copper strip of size (50 x 5) mm, PVC sheathed with colour coding.(b) MCCB having current rating 400 Amps with rupturing cap 36 KA, AC 415 Volts four pole, Ics = 100% of Icu with adjustable thermal and Magnetic Release complete with spreader links. (Qty -01 No)Make : L&T D-sine (CM9840300Q00G) or equivalent of make Legrand / ABB / Havells.(c) Onload Change over of rating 315 Amp 4 pole , 415 volts. - (01 Nos) Make : L&T cat pt No C0331500000 or equivalent of make Havells/ Schnider.(d) Multifunctional digital panel meter with LCD display flush mounting type of size 96X96 mm, accuracy class 1, suitable for CTs with secondary current 5A having provision of display parameters such as voltage, Amp, Frequency, Power factor, KW, KV etc. (Qty - 01 No)Make : L&T (Cat Pt No WL440511OOOO) or equivalent of make Schneider / AE.(e) Current transformer of ratio 400 / 5 amps,current rating primaryup to 400 amps and secondary5 amps , accuracy class 1, VA burden 10 VA including necessary wiring using PVC insulated copper conductor cable of appropriate size as per standard engineering practice.(Qty - 1 No Set of three)Make:L&T or equivalent of make Schneider / AE. (f) LED Phase Indicator Lamp(Qty - 01 Set of Three).Make : L&T or equivalent of make Schneider / AE. |
| 28 | Outgoing:(a) MCCB having current carring rating 100 Amp with rupturing capacity 25 KA , AC 415 Volts three pole, Ics = 100% of Icu with adjustable thermal magnetic release complete with spreader links. (Qty- 02 Nos.)Make : L&T D-sine (CM9161200K00G) or equivalent of make Legrand / ABB / Havells.(b) MCCB having current carring rating 32 Amp with rupturing capacity 25 KA , AC 415 Volts three pole, Ics = 100% of Icu with adjustable thermal magnetic release complete with spreader links. (Qty- 10 Nos.)Make : L&T D-sine (CM9161200E00G) or equivalent of make Legrand / ABB / Havells. |
| 29 | Note :-(i)The quoted rate shall includes minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc.(ii) All internal wiring shall be done with suitable size of PVC insulated solid Aluminium conductor FRLS cable conforming toIS-694.(iii) Panel drawing shall be got approved before placing of orderfrom Engr-in-Charge/GE.(iv)The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated.(vi) The Panel shall be surrounded with 9 inch brick wall upto 0.5 mtr height all around the panel and blank portion between panel and wall shall be filled with PCC 1:2:4incl masonary work leaving ducts for cables complete all as directed.(vii) All MCCBs have Ics= 100% Icu. |
| 30 | Supplying, installing, testing & commissioning out door type cubical panel board outer shell made out of3.15 mm thick MS sheet including door and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm aboveand 45 cm below the ground level,frame factory fabricated with front & back openable, double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able by Keyshaving chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricatedhaving modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 comprising of the following :- |
| 31 | a) Aluminium bus bar 300 Amps cap 4 wire fixed on insulator not less than 1.0 mtr long bus bar -1 set(b) Incoming MCCB 160 Amps 4 pole 415 Volts AC with thermal magnetic 36 KA, Ics=100%, Icu class-2 front face isolation with positive break indication with double break contacts with spreader and phase barrier complete all as directed. - 1 Nos.Make - Schneider/Legrand/Siemens/ABB/HAGER(c) Outgoing MCCB 63 Amps 4 pole 415 Volts AC with thermal magnetic 25 KA,with double break contacts with spreader and phase barrier complete all as directed. -3 Nos Make - Schneider/Legrand/Siemens/ABB/HAGER(d) Outgoing MCB 32 Amps 2 poleAC with thermal magnetic 10 KA,with double break contacts with spreader and phase barrier complete all as directed. - 3 NosMake - Schneider/Legrand/Siemens/ABB/HAGERe) Digital Ammeter 0-500 A of size 96sqmm with selector switch-01 No.Make Schneider/Legrand/ABBf) Digital Volt meter 0-500 V of size 96sqmm with selector switch-01 NoMake Schneider/Legrand/ABBg) Indicator Lamp RYB 22.5mm dia LED type 240 volts AC with incoming includin back up protection by 2 Amp MCB RYB with holder-01 set of three.Make -Schneider/Legrand/ABBh) CT Coils of suitable ratio-01 Set. Make- AE |
| 32 | Note :-(i)The quoted rate shall includes minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc.(ii) All internal wiring shall be done with suitable size of PVC insulated solid Aluminium conductor FRLS cable conforming toIS-694.(iii) Panel drawing shall be got approved before placing of orderfrom Engr-in-Charge/GE.(iv)The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated.(vi) The Panel shall be surrounded with 9 inch brick wall upto 0.5 mtr height all around the panel and blank portion between panel and wall shall be filled with PCC 1:2:4incl masonary work leaving ducts for cables complete all as directed.(vii) All MCCBs have Ics= 100% Icu. |
| 33 | Supply, installation , commissioning and testing LT bus bar feeder pillar boxin replacement of suitable size,outdoor cubical type floor mounted factory madeof CPRI approved factory, totally enclosed vermin proof with front and rear opening with IP-54 protection as per IS - 8623 duly powder coated , fabricated out of 2.0 mm thick mild steel sheet mounted on frame of mild steel angle iron 60 cm x 60 cm x 6mm and , 45 cm aboveground level duly supported with mild steel angle iron struts 60 cm x 60 cm x 6mm thick and embedded in PCC foundation inPCC 1:2:4, type B-1 , using 20 mm graded crushed stone aggregate , with suitable 415 Volt, 3 phase, four wirecopper bus bar of rating capacity 400 Amps duly drilled holes for connections, R-Y-B-N insulated with different colour code and sleeved mounted on insulators complete prewired and cable connection with copper conductor wire upto Aluminium bus bars including all incoming and outgoing cable connections with suitable size of copper lugs/ glandincluding supply and fixing of MCCB four pole, 415V,I/C- 160 Amp. 25KA-01 No including taking out old unserviceable, complete all as specified and directed by Engr - in- Charge. Make-Hensel/ABB/Emitter/Schneider/Siemens. |
| 34 | Supply, installation , commissioning and testing LT bus bar feeder pillar boxin replacement of suitable size,outdoor cubical type floor mounted factory madeof CPRI approved factory, totally enclosed vermin proof with front and rear opening with IP-54 protection as per IS - 8623 duly powder coated , fabricated out of 2.0 mm thick mild steel sheet mounted on frame of mild steel angle iron 60 cm x 60 cm x 6mm and , 45 cm aboveground level duly supported with mild steel angle iron struts 60 cm x 60 cm x 6mm thick and embedded in PCC foundation inPCC 1:2:4, type B-1 , using 20 mm graded crushed stone aggregate , with suitable 415 Volt, 3 phase, four wirecopper bus bar of rating capacity 400 Amps duly drilled holes for connections, R-Y-B-N insulated with different colour code and sleeved mounted on insulators complete prewired and cable connection with copper conductor wire upto Aluminium bus bars including all incoming and outgoing cable connections with suitable size of copper lugs/ glandincluding supply and fixing of MCCB four pole, 415V,I/C- 100 Amp. 16KA-01 No including taking out old unserviceable, complete all as specified and directed by Engr - in- Charge. Make-Hensel/ABB/Emitter/Schneider/Siemens. |
| 35 | S&F in repairs change over switchs off-load400amps 4 polesheet metal enclosure including taking down old UNSV one complete all as specified and directed. |
| 36 | S&Fin repairs change over switchs off-load315amps 4 polesheet metal encloser including taking down old UNSV one complete all as specified and directed. |
| 37 | S&F change over switchs off-load200amps 4 poleincl sheet metal enclosure including taking down old UNSV one complete all as specified and directed. |
| 38 | S&F in repairs cable Junction Boxes with terminals` IP 66 \"halogen free and weather proof” for outdoor installation (with metric knockouts for cable entry - Black Colour) Cable Size 16/25 Sqmm, Box Dimensions-200 x160 x 98, Catalog No-KF 9255(hensel) complete taking out of loop of cable from ground by neccessary earth work all as spcefied and directed by Engr-in- charge. Make- Hensel/Dowells/Sintex |
| 39 | Supply , laying , testing & CommissioningUG cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm, 4 core including taking down old cable with suitable thimbles complete all as specified and directed by Engr-in-Charge. |
| 40 | Description all as per item No-34 butsize 25sq mm, 3.5 core complete all as specified and directed by Engr-in-Charge. |
| 41 | Description all as per item No-34 butsize 35sq mm, 3.5 core complete all as specified and directed by Engr-in-Charge. |
| 42 | Description all as per item No-34 butsize 50 sq mm, 3.5 core complete all as specified and directed by Engr-in-Charge. |
| 43 | M & L for Cutting through existing road surfaces i.e. surfacing PCC soling etc, and making trench of minimum 500mm wide 100cm in depth along the cross section of road for laying of pipes or UG cables, including returning filing in, well ramming & removal of surplus spoil to a distance not exc. 50 m & repairs to road surfaces to match with existing specification after laying the pipes/cable etc. all as specified & directed. |
| 44 | Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paintall as specified. |
| 45 | Supply and fixing aluminium thimbles in replacement suitable for under ground LTcables of sizes 16 Sqmm including cutting of exsting burn/damaged cable after disconnecting from existing position complete all as specified and as directed by Engr-in-Charge. |
| 46 | All as per Item No. 40 but size25 Sqmm complete all as specified and as directed by Engr-in-Charge. |
| 47 | All as per Item No. 40 but size50 Sqmm complete all as specified and as directed by Engr-in-Charge. |
| 48 | S&Fin replacement of Integral LED Bollards complete with copper dust finish cylindrical shaped unique design, integral decorative bollard wth clear/opal acrylic for LED lampcomplete all as specified and directed, capacity 12Watt LED Lamp. |
| 49 | S&Fin replacement of integralpost top lanterns complete with Black ABC plastic spigot, spun aluminium funnel shape with clear acrylic cover light opening on canopy with baffles and accessories and suitable for LED 10 Watt lampcomplete all as specified and directed. Make- Crompton/Bajaj/C&S/Havells |
| 50 | S&Fof timer controll panel consisting of following :- (a) Timer switch anloge type - 01 (b) contactor 2 pole 32 Amp , 240 volts- 01, (c) Indicator red and green-01 Nos (d) MCB SPN 40 Amps- 01 Nos (e) Control fuse 6 A - 01 No (f) Auto /Mannual selector switch - 01 (g) Controll wiring - 01 setinstalled inthermoplastic polycarbonets enclosure of suitable size 300x600x170 mm weather/vermin proof hindge door type with locking arrangement duly provided with neoprene rubber gasket along the doors with counter shunk hole at bottom for base mounting bracket and grouted in ground by using angle iron frame of size 50x50x6mm in PCC (1:2:4) type C1 with 20mm graded stone aggregate etc complete all as specified & directed.Make of timer switch : Legrand/Hager/Schneider Elect.Make of enclosure : Rittal/Hensel/BCH. |
| 51 | M & L for fixingnew street light bracket made out of GI pipe light grade 32/40 mm bore approx length not less than 120 cm bent to shape including new clamps made of MS flat of size 40x5 mm thick including cutting ,welding ,drilling holes ,nut,bolts washers etc including two coat of aluminium paint over one coat of red oxide primer on MS work complete all as specified and as directed.Make of pipe : Jindal (Hisar), Tata , Prakash Surya/Elecrosteel (Location : Sashithar- 20, Salyarchatta-30 approx) |
| 52 | Re-Laying only of serviceable LT UG cable of any sizeand type in trenches, floors, across road crossing, or fixed on poles, walls with clam, or passing through pipe, complete all as specified and as directed.Note:-i). Handling of UG cable to working site as ordered shall be carried out by the firm and rate for the same shall deem to be included in the unit rate . |
| 53 | Supply and laying of DWC (Double Wall Corrugated) HDPE Pipe, ISI Marked IS 16205 Part-II, of outer dia of 63 mm and inner dia 50 mm with smooth internal and profiled external surface for non pressure under ground cable including all connected accessories like coupler, \"O\" Ring etc, for protection of cablecomplete all as specified and as directed. |
| 54 | Ditto all as per items No 48 but of size 77mm outer dia and 63mm inner dia |
| 55 | Supply and fixing ACSR conductor of size mink complete all as specified and as directed by Engineer-in-Charge. |
| 56 | Supply and Fixing GI tubing light grade 50mm dia along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles including taking out old broken GI pipes, complete all as specified and as directed by Engr-in-Charge. |
| 57 | Dismantling steel or concrete poles/struts any size complete. |
| 58 | Supply, install and erect in true vertical position (or to be fixed in an inclined position as strut pole) steel tubular swaged poles complete with MS base plate of 6 mm thick of size 300 mm x 300 mm, finial taper plug, pole cap, bolts, nuts and washers and screwed pole made out of FRW MS tubing conforming to IS-2713 (Part-II) 1980 type 410-SP-31 ( 9 meters long ) pole including drilling of holes of required size and Nos for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embeded in concrete, etc complete all as specified and directed |
| 59 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in any type ofsoil for laying of LT UG cablescomplete all as specified and as directed by Engr in charge. Note:- The Ratequoted deemed to including cutting and removal of PSP Sheets wherever occured during excavation and the same shall be staged at desired location as directed at site |
| 60 | Returning, filling in,including spreading levelling, watering and well ramming in layers not exceeding 25 cm thickin hard dense soil complete all as specified and as directed by Engr in charge. |
| 61 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by Engr in charge. |
| 62 | M&L for PCC 1:4:8 type D-2 using 40mm graded aggregate, mechanically crushed stone for mass filling in polepit and foundation etc including provision of necessary form work to achieve fair finished surfaces complete all as specified and as directed. |
| 63 | M&L for PCC 1:3:6 type C-2 using 20mm graded crushed stone aggregate as in pole pole foundation, coping, stay pits etc including provision of necessary form work i.e road cuttingto aachieve fair finishes surfaces, complete alal as specified and directed. |
| 64 | Taking down UNSV fuel pump and repair/replacement /overhauling and calibration of fuel pump complete with replacement of burn out part such as bearing ,plunger,impeller and oil seal ring etc including calibration of 32.5 KVA to 160 KVA DG Set ,complete all as specified and directed by Engr-in-charge. |
| 65 | Taking down injectors assembly for repair/replacement/overhaulingand calibration of injectors assembly complete by replacing of burn out partsuitable for 32.5 to 160 KVA DG SET ,complete all as specifiedand directed by Engr-in-charge. |
| 66 | M&L for asbestos rope of suitable size andsuperier qualityfor heat insulation including rapping arround the exhaust pipe and winding with wire mess and plastering with plaster of peris /white cement for smooth finishing all as specified and directed by Engr-in-charge. |
| 67 | Servicing of diesel engine generating setcapacityupto 160 KVA repair/replacement of the following defective parts through authorised service engineer/mechanic . (a) Drain out the lubricanting oil from sump and refilling after proper cleaning. (b) Replace Engine Oil filter cartidge with same size.(c) Renew Fuel filter cartridge with same size. (d) Check tightness of all nuts and bolts.(e)Check adjustment of V belt for driving engine water pump and alternator.(f) Assembling complete old serviceable parts and replacement of old unserviceable parts by new one as per direction of Engr-in-Charge. (g) Testing of DG set after servicing as per Engr-in-Charge.(h) Cleaning of air cleaner filter after period of hrs run as specified by manufactures in manual.(Note : (i) Any minor parts such as screw, washers , split pin , circlip etc shall be supplied by the firm , rate for the same shall be deemed to be included in the unit rate quoted. (ii) The job shall be carried out after two, hundred hrs run/ as when required directed by Engr-in-Charge of DG set and shall be measured and paid separately, no of times carried out during entire period of contract . (iii) During servicing of engine oil shall be issued by Department. |
| 68 | Fuel filter |
| 69 | Engine oil filter |
| 70 | Airfilter |
| 71 | Draining out old engine oil and refilling by multigrade engine oil 15W-40 (Servo) |
| 72 | Battery terminal |
| 73 | Fuel pipe |
| 74 | Hose pipe |
| 75 | Self starter repair |
| 76 | Oil seal and timing set |
| 77 | Control KVAR 3U2 Part No KVAR3U200000 |
| 78 | Radiator cleaning with acid and fins repair |
| 79 | Coolant |
| 80 | Battery leads |
| 81 | Fan belt |
| 82 | Fan belt for alternator |
| 83 | Taking out UNSV and supply and installing as in replacement of 12 volt 150 AH lead acid wet maintenance free battery including initial charging with necessary material connecting with battery lead of DG Set at site complete. |
| 84 | Taking out UNSV andS&Fnew alternator 12/24 V DC Make:-Lucas.TVS,all including dismantling of defectivealternator and replacement of burn outs, bolts, mountingclamp etcall as specified and directed by Engr-in-Charge |
| 85 | Repair/replacement of relay for capacity DG set 40 KVA to 160 KVA all as specified and directed by Engr-in-Charge. |
| 86 | Rewinding ofAlternator Complete IncludingAndSupply and replacement of copper Wire including suitable winding material rewinding the stator windingwith exsting size,guage &wieght of super enamelled copper wire of approved make including replacement of all insulating material varneshing with approved grade and quality of insulating varnish during up,and heating the stator windingin the heat chamber ,insulating , assembling the alternatorComplete.all as specified and directed by Engr-in-charge. |
| 87 | Taking out UNSV andSupply and FixingMS Pipe of Size 100 mm Diafor DG Set Silencer Including Welding And Painting complete all as specified |
| 88 | Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4 mm dia galvanised earth lead wire by means of bolts, nuts, check nuts and washers of galvanised standard iron or steel all as specified or indicated in electrical plate no 3 of MES Part-I, including testing on completion including the material and labour of the following :- (a) Excavation and earth work for drilling hole for electrodein any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1 .c) Precast RCC coverwith suitablehandle 40 mm thickinPCC1:2:4type B-1,reinforced with welded steel wirefabric weighing notless than 1.87 Kg/Sqm.(d) Funnelwithwatering pipe of GI20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 15 mm nominal bore light grade GI protection pipe 5 mtrlongforprotectionof earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing.Note : (a) On testing after completionof earthing, ifthe desired earth resistanceisnotobtained,theearthingwill bere-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.(b) The contractor shall quote his rate considering taking down cost of existing unserviceable earthing. |
| 89 | Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 25 x 4 mm galvanised earth strip by means of bolts, nuts, check nuts and washers of galvanised standard iron or steel all as specified or indicated in electrical plate no 3 of MES Part-I, including testing on completion including the material and labour of the following :a) Excavation and earth work for drilling hole for electrodein any type of soil.(b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC coverwith suitablehandle 40 mm thickinPCC1:2:4type B-1,reinforced with welded steel wirefabric weighing notless than 1.87 Kg/Sqm(.d) Funnelwithwatering pipe of GI20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 40 mm nominal bore light grade GI protection pipe 5 mtrlongforprotectionof earthing lead from mechanical injury or tempering. ( f) Requisite quantity of common salt and charcoal.(g) Testing of earthing.Note : (a) On testing after completionof earthing, ifthe desired earth resistanceisnotobtained,theearthingwill bere-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.(b) The contractor shall quote his rate considering taking down cost of existing unserviceable earthing. |
| 90 | Earthing of machinery/equipment Installed at power house/substation complete with copper earth plate electrode 60×60cm.× 3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth lead 20x3 mm Copper stripby means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion. |
| 91 | Repair/replacement of industrial RO CPVC pipe 15mm complete with accessories complete all as specified and directed by Engr-in-Charge. |
| 92 | Supply and fixing PVC clamps for CPVC including aasy complete all as specified and directed by Engr-in-Charge. |
| 93 | Servicing of industrial RO at Shashithar and Salyarchatta 23 Wing AF including carrying out maintenance and check alongwithfollowing repairs (a) Drain out the pipe and Replace new pipe and fixing the same.(c) Cartridge (d) Check tightness of all fitting Note:-Any minor/major parts such as screws,fillet,membrane, washers,PVC fitting etc shall be supplied by the firm, rate for the same shall be deemed to be excluded in the unit rate quoted. |
| 94 | Supply membrane for industrial RO complete all as specified and as directed by Engr-in-Charge. |
| 95 | Supply UV for industrial RO complete all as specified and as directed by Engr-in-Charge. |
| 96 | Supply and Fixing in repair of dimmer stat 60 amps oil cooled single phase complete all as specified and as directed by Engr-in-Charge. |
| 97 | S&Fin repair controller control module panel for diesel generator DSE7320 with manual /autoelectronicssuitable for 40 to 160 KVA DG Set complete all as specified and as directed by Engr-in-Charge. |
| 98 | Supply and laying of 40 mm CPVC pipe SDR 11 & plain CPVC SDR 11 fitting including making connection with existing line including all accessories and fixing on wall and ground/ceilingor laying in floor completeincluding taking out old rusted/broken GI pipes, complete all as specified and as directed by Engr-in-Charge. |
| 99 | Supply and laying of 25 mm CPVC pipe SDR 11 & plain CPVC SDR 11 fitting including making connection with existing line including all accessories and fixing on wall and ground/ceilingor laying in floor completeincluding taking out old rusted/broken GI pipes, complete all as specified and as directed by Engr-in-Charge. |
| 100 | Supply and laying of 15 mm CPVC pipe SDR 11 & plain CPVC SDR 11 fitting including making connection with existing line including all accessories and fixing on wall and ground/ceilingor laying in floor completeincluding taking out old rusted/broken GI pipes, complete all as specified and as directed by Engr-in-Charge. |
| 101 | Supply and fixing Hot water pipe duly insulated with glass wool and aluminium cladding up to 25 mm bore including joints, bend, tee,including taking out old rusted/broken pipes, complete all as specified and as directed. |
| 102 | Material and labour for servicing solar manifold and tank by removing all the tubes in the monifold, cleaning the tubes internally, removing the blockages in the tubes and cleaning the tank and removing all the impurities, assembling and testing for satisfactory function complete all as specified and directed by Engr-in-Charge. |
| 103 | S&F in repairs heating element for solar water heateing plant with rubber washer (O ring) cap 3 KW tringler/round type complete all as specified and as directed by Engr in charge. |
| 104 | S&F in repairs thermostat for solar water heateing plant sutable size and rating etc complete all as specified and as directed by Engr in charge. |
| 105 | S&Fin replacement outdoor type Tiranga LED Rope light suitable for 9/11 mtr electric PCC/SteelPole decorative, Operting Voltage 140-270 Volts 240V AC Supply 50Hz supply connection from down side Jn box including driver and two run of 1.5 sqmm single core unarmoured wire from Junction boxcomplete all as specified and directed by Engr-in-Charge. |
| 106 | S&F in repairs copper wire 1.5 Sqmm FRLS green/red colour single core complete all as specified and as directed by Engineer-in-Charge.Anchor/Havells/Polycab (Note;- PVC Conduit will be Measureand paid seperatly as relevent item.) |
| 107 | S&F in repairs copper wire 2.5 Sqmm FRLS green/red/black colour single core complete all as specified and as directed by Engineer-in-Charge.Anchor/Havells/Polycab (Note;- PVC Conduit will be Measureand paid seperatly as relevent item.) |
| 108 | S&F ceiling fan complete with aluminium blades, down rods, 230V, 1200 mm sweep.Min air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) all as specified and as directed by Engineer-in-Charge. |
| 109 | M & L for sub main wiring with two single core FRLS, PVC insulated, stranded, unsheathed cable copper conductor with size 04 Sqmm and drawing through& including Non metallic PVC conduit concealed in wall including earth continuity conductor of size 04 Sqmm PVC insulated unsheathed stranded copper conductor cable and connected to earth dolly to be drawn in concealed PVC conduit including connecting to main board complete all as specified and directed by Engineer-in-Charge. |
| 110 | S&F in repairs capacitor of 2.5 Mfd. AC 230/240 volts, 50 Hzcomplete all as specified and directed by the Engineer-in-Charge. |
| 111 | M & L forindustrial type metal socket enclosure with 240 volt MCB 20 Amps, withmetal plug top complete all as specified incl taking down old unserviceable one. |
| 112 | Repair to motor and pump capacity upto 20 HP involving the following operations. (a) Dismanting (opening) of motor pump complete in MES installation/workshop part by of all the stationary parts, cleaning the covers and part as applicable. (b) Servicing, cleaning of motor pump accessoried and part by part all the as applicable such as inner motor, water inlet, stunner, etc replacement of unserviceable parts, like bearing, bushes, wires, copper winding & including it in serviceable condition & refixing in its original position all is specified by Engr-in Charge. |
| 113 | Supply and fixing Three Pin 15 Amp plug top 240 Volts complete all as specified and directed by Engr-in-Charge. |
| 114 | SCHEDULE \"A\" PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch \"A\" Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail