| 1 | SUPPLY- GIS: 400KV, 63KA FOR 3S, DOUBLE BUS SCHEME GAS INSULATED SWITCHGEAR (GIS) AS PER TS (For item sl. No. 1.01-1.13):400KV, 2000A, 63KA FOR 3S, SF6 GIS GENERATOR TRANSFORMER FEEDER BAY MODULE |
| 2 | 400KV, 2000A, 63KA FOR 3S, SF6 GIS ICT FEEDER BAY MODULE |
| 3 | 400KV, 2000A, 63KA FOR 3S, SF6 GIS REACTOR FEEDER BAY MODULE |
| 4 | 400KV, 2000A ,63KA FOR 3S, GIS LINE FEEDER BAY MODULE |
| 5 | 400KV, 2000A, 63KA FOR 3S, SF6 GIS BUS COUPLER BAY MODULE |
| 6 | 400KV, 63KA FOR 3S, SF6 BUS VT BAY MODULE INCLUDING DISCONNECTOR, EARTHSWDUC, INCLUDING MAIN BUS EARTHSWITCH |
| 7 | 400 KV, 2000 A, 63 KA, 3S, SINGLE PHASE, SF₆ GIS MAIN BUSBAR. (MODE OF MEASUREMENT SHALL BE THE STRAIGHT LENGTH OF THE MAIN BUSBAR ALONG THE GIS HALL) |
| 8 | 400KV, 2000A, 63KA FOR 3S, SINGLE PHASE, SF6 GAS INSULATED BUS DUCT (GIB) OUTSIDE GIS HALL |
| 9 | MAIN BUS BAR END PIECE (INTERFACE) MODULES SET OF 3 PAHSE |
| 10 | 400KV, 2000A, 63KA FOR 3S, SINGLE PHASE, SF6 TO CABLE CONNECTION MODULE |
| 11 | 400KV, 2000A, 63KA FOR 3S, SINGLE PHASE, SF6 TO OIL CONNECTION MODULE |
| 12 | CONTROLLED SWITCHING DEVICE FOR 3-PH CIRCUIT BREAKER |
| 13 | Bay Control Unit (BCU) |
| 14 | SUPPLY- GIS: SPECIAL TOOLS AND TESTING & MAINTENANCE INSTRUMENTS (SCOPE OF SUPPLY & SERVICES ARE SUBJECT TO CHANGE) (For item Sl. No. 2.01-2.10):ONLINE GAS MONITORING SYSTEM INCLUDINGLOCAL MONITORING DISPLAY UNIT, HUMAN MACHINE INTERFACE (HMI) PANEL FOR GIS: |
| 15 | PORTABLE PARTIAL DISCHARGE MEASUREMENT TEST KIT WITH ALL NECESSARY ACCESSORIES, INDUSTRIAL GRADE LAPTOP AND LICENSED SOFTWARE |
| 16 | SF6 GAS TREATMENT PLANT FOR 400KV GIS STATION |
| 17 | TWO-WHEEL SF6 GAS MAINTENANCE CART |
| 18 | SF6 GAS ANALYZER |
| 19 | SF6 GAS LEAKAGE DETECTOR |
| 20 | SUPPLY OF DEW POINT METER |
| 21 | Time Recorders For Breaker |
| 22 | Time Recorders For Isolators |
| 23 | Instrument For Automatic And Continuous Gas Monitoring In GIS Hall |
| 24 | MANDATORY SPARES - ITEM DESCRIPTION (For item Sl. No. 3.101-3.820):SF6 TO CABLE CONNECTION MODULE (GIS PORTION) Cable Connection Enclosure with the main Circuit - (Set of each type and rating) |
| 25 | SF6 TO OIL CONNECTION MODULE (GIS PORTION) for bushing of Transformer/Reactor as applicable of each rating with the main circuit (Set of each type and rating) |
| 26 | SF6 gas Pressure Relief Devices of each type along with O-rings (Set of each type and rating) |
| 27 | SF6 Pressure gauge cum switch OR Density monitors and pressure switch (as applicable) Percentage of Total population (max 5 min 1) |
| 28 | Coupling device of each type for pressure gauge cum switch for connecting Gas handling plant (Set of each type and rating) |
| 29 | Rubber Gaskets, O-Rings and Seals for SF6 gas of each type (Set of each type and rating) |
| 30 | Molecular filter for SF6 gas with filter bags, Percentage of Total weight |
| 31 | All types of Control Valves for SF6 gas of each type (Set of 1 number of each type and rating) |
| 32 | Spare SF6 Gas, Percentage of Total gas quantity by weight |
| 33 | Additional (10%) supply of SF6 Gas complete with containers and monitoring equipment for use during the warranty period. (gas quantity by weight) |
| 34 | Locking device to keep the Dis-connectors (Isolators) and Earthing switches in close or open position (Set of 1 number of each type and rating) |
| 35 | Spares for local control cabinet including MCB, Fuses, Timers, Aux. relays, Contactor, Push Buttons, Switches, Lamps, Annunciation Windows etc. (Set of each type and rating) |
| 36 | UHF PD Sensors of each type, Percentage of Total population (max 5 Nos and min. 1 No.) |
| 37 | Support Insulator/Gas Barrier of each type along with associated contacts and shields (Set of 1 number of each type and rating) |
| 38 | SF6 Gas Filling Kit (Hose, valve adaptors, regulator) complete set |
| 39 | Gas Sampling Port Adapter and Gas Filters (Moisture/Particle) complete set |
| 40 | Partial Discharge Sensors (UHF/VHF) of Online condition monitoring complete set |
| 41 | GIS Alignment Tool Kit - OEM-specific torque tools, alignment jigs FULL KIT SET |
| 42 | Controlled Switching Device along with Transducers, Sensors, Contactors, Switches etc. (Set of each type and rating) |
| 43 | Complete Circuit Breaker (1 phase unit) of each type & rating (complete with interrupter, main circuit, enclosure and Marshalling Box) (Set of each type and rating) |
| 44 | Trip coil assembly with resistor as applicable (Set of each type and rating) |
| 45 | Closing coil assembly with resistor as applicable (Set of each type and rating) |
| 46 | CIRCUIT BREAKER: Grading Capacitor (Nos.) |
| 47 | CIRCUIT BREAKER: Rubber gaskets, O-rings and seals (Set of each type and rating) |
| 48 | CIRCUIT BREAKER: Molecular filter (Nos.) |
| 49 | CIRCUIT BREAKER: Density/Pressure monitoring systems (Nos.) |
| 50 | CIRCUIT BREAKER: SF6 Gas (for CB), Percentage of Total used quantity in substation |
| 51 | CIRCUIT BREAKER: Relays, Power contactors, push buttons, timers & MCBs etc. of each type and rating (Set of each type and rating) |
| 52 | CIRCUIT BREAKER: Auxiliary switch assembly (Set of each type and rating) |
| 53 | CIRCUIT BREAKER: Operation Counter (Set of each type and rating) |
| 54 | CIRCUIT BREAKER: Window scope / Observing window (Set of each type and rating) |
| 55 | CIRCUIT BREAKER: LOTO arrangement provision (Set of each type and rating) |
| 56 | Hydraulic operating mechanism with drive motor of each type (Set of each type and rating) |
| 57 | Ferrules, joints and couplings of each type (For Hydraulic Operated Mechanism, if applicable) (Set of each type and rating) |
| 58 | Hydraulic filter of each type (For Hydraulic Operated Mechanism, if applicable) (Set of each type and rating) |
| 59 | Hose pipe of each type (For Hydraulic Operated Mechanism, if applicable) (Set of each type and rating) |
| 60 | N2 Accumulator of each type (For Hydraulic Operated Mechanism, if applicable) (Set of each type and rating) |
| 61 | Valves of each type including Safety valve (For Hydraulic Operated Mechanism, if applicable) (Set of each type and rating) |
| 62 | Valves of each type (For Hydraulic Operated Mechanism, if applicable) (Set of each type and rating) |
| 63 | Pipe length (copper & steel) of each size & type (For Hydraulic Operated Mechanism, if applicable) (Set of each type and rating) |
| 64 | Pressure switches of each type (Set of each type and rating) |
| 65 | Pressure gauge with coupling device of each type (For Hydraulic Operated Mechanism, if applicable) (Set of each type and rating) |
| 66 | Hydraulic oil (For Hydraulic Operated Mechanism, if applicable), Percentage of total qty. used |
| 67 | Pressure Relief Device of each type (For Hydraulic Operated Mechanism, if applicable) (Set of each type and rating) |
| 68 | Spring Charging Motor with Limit switch (For Hydraulic Operated Mechanism, if applicable) (Set of 1 number of each type and rating) |
| 69 | Complete Spring Operating Mechanism including charging mechanism etc. of each type (Set of each type and rating) |
| 70 | Spring Charging Motor (Set of 1 number of each type and rating) |
| 71 | Complete set of 3 nos. of single phase / one 3-phase isolator of each type (Set of each type and rating) |
| 72 | 3 No. of single phase / one no of 3-phase Maintenance Earthing switch of each type (Set of each type and rating) |
| 73 | 3 No. of single phase / one no of 3-phase Fast Earthing switch of each type (if applicable) (Set of each type and rating) |
| 74 | Copper contact fingers for isolator male & female contact along with corona shield – for one complete (3 phase) isolator (Set of each type and rating) |
| 75 | Copper contact fingers for Maintenance Earthing switch male & female contacts along with corona shield (Set of each type and rating) |
| 76 | Isolator Arms with finger contacts and current carrying assembly complete set |
| 77 | Copper contact fingers for Fast Earthing switch male & female contacts along with corona shield (if applicable) (Set of each type and rating) |
| 78 | Open / Close contactor assembly, timers, key interlock, interlocking coils, relays, push buttons, indicating lamps Power contactors, resistors, fuses, MCBs & drive control cards etc. - for one complete MOM box (3 – phase gang operated or 1 – phase unit) dis-connector |
| 79 | Open / Close contactor assembly, timers, key interlock, interlocking coils, relays, push buttons, indicating lamps Power contactors, resistors, fuses, MCBs & drive control cards etc. - for one complete MOM box (3 – phase gang operated or 1 – phase unit) Maintenance Earth switch |
| 80 | Open / Close contactor assembly, timers, key interlock, interlocking coils, relays, push buttons, indicating lamps Power contactors, resistors, fuses, MCBs & drive control cards etc. - for one complete MOM box (3 – phase gang operated or 1 – phase unit) Fast Acting Earth switch |
| 81 | Limit switch and Aux. Switches for complete 3 phase equipment - For Isolator |
| 82 | Limit switch and Aux. Switches for complete 3 phase equipment - For Maintenance Earth switch |
| 83 | Limit switch and Aux. Switches for complete 3 phase equipment - For Fast Earthing Switch (if applicable) |
| 84 | Drive Mechanism - For Isolator (Set of each type and rating) |
| 85 | Drive Mechanism - For Maintenance Earth switch (Set of each type and rating) |
| 86 | Drive Mechanism - For Fast Earthing Switch (if applicable) (Set of each type and rating) |
| 87 | Motor for Drive Mechanism - For Isolator (Set of 1 number of each type and rating) |
| 88 | Motor for Drive Mechanism - For Maintenance Earth switch (Set of 1 number of each type and rating) |
| 89 | Motor for Drive Mechanism - For Fast Earthing Switch (if applicable) (Set of 1 number of each type and rating) |
| 90 | Mechanical Interlock Devices interlock for earth switch and isolator (Set of each type and rating) |
| 91 | LOTO arrangement provision for Isolator (Set of each type and rating) |
| 92 | Complete CT with Terminal connector & structure of each type and rating with enclosure to enable replacement of any type/ rating of CT by spare |
| 93 | Primary Terminal Bushing of CURRENT TRANSFORMER complete set |
| 94 | Complete VT with Terminal connector & structure of each type and rating with enclosure to enable replacement of any type/rating of VT by spare (if applicable) |
| 95 | Gas insulated SA for of each type and ratings enclosure & surge monitor counter to enable replacement of any type/rating of GasInsulated SA by spare (if applicable) |
| 96 | Surge counter/ monitor of each rating and type for SURGE ARRESTOR (Set of each type and rating) |
| 97 | Tool For Lamp In Local Panel |
| 98 | Special Gas Mask For GIS Maintenance No 2 No |
| 99 | Display Unit (of HMI panel for GIS) |
| 100 | SPARES- GIS: OPTIONAL ITEM / REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS (Unit Prices of Individual Equipment included here or in manadatory spares are required for any Addition/Deletion of Equipment and replacement of damaged items/ additional requirements =. Bidder to ensure that the unit prices have a logical relationship with prices of assemblies in main items. Quoting for unit prices is mandatory and shall be considered for evaluation) (For item sl. No. 4.01-4.02):SUPPLY- GIS: SPARES: 400KV, EXPANSION JOINT - 3 PHASE (ANY OF MAIN BUS / GIB) |
| 101 | SUPPLY- GIS: SPARES: 400KV, L-BEND ( 1 PHASE) |
| 102 | SPARE FOR SF6 GAS TREATMENT PLANT- Vacuum Pump |
| 103 | SPARE FOR SF6 GAS TREATMENT PLANT- Nozzles, Hoses |
| 104 | SPARE FOR SF6 GAS TREATMENT PLANT-Compressors With Gauges, Valves, Filters, Driers & Controls With Necessary Spares |
| 105 | SPARE FOR TWO-WHEEL SF6 GAS MAINTENANCE CART- Vacuum Pump |
| 106 | SPARE FOR TWO-WHEEL SF6 GAS MAINTENANCE CART- Nozzles, Hoses |
| 107 | SPARE FOR TWO-WHEEL SF6 GAS MAINTENANCE CART -Compressors With Gauges, Valves, Filters, Driers & Controls With Necessary Spares |
| 108 | SERVICES- GIS : 400KV, 63KA FOR 3S FOR IS, GAS INSULATED SWITCHGEAR (GIS) AS PER TS (For item sl. No. 5.01-5.12):SERVICES- 400KV GIS: SUPERVISION OF ERECTION OF GIS |
| 109 | SERVICES- 400KV GIS: SUPERVISION OF ERECTION OF GAS INSULATED BUS DUCT 1 PHASE(OUTSIDE GIS HALL) |
| 110 | SERVICES- 400KV GIS: SUPERVISION OF ERECTION OF SINGLE PHASE, SF6 TO CABLE CONNECTION MODULE |
| 111 | SERVICES- 400KV GIS: SUPERVISION OF ERECTION-400KV, SINGLE PHASE, SF6 TO OIL CONNECTION MODULE |
| 112 | SERVICES- 400KV GIS: TESTING & COMMISSIONING OF GIS |
| 113 | SERVICES- 400KV GIS : TESTING & COMMISSIONING OF OF GAS INSULATED BUS DUCT 1 PHASE |
| 114 | SERVICES- 400KV, SINGLE PHASE, SF6 TO CABLE CONNECTION MODULE, TESTING & COMMISSIONINGOF |
| 115 | SERVICES- 400KV, SINGLE PHASE, SF6 TO OIL BUSHING:TESTING & COMMISSIONING |
| 116 | SERVICES- 400KV GIS : FINAL SUCCESSFUL HV/ POWER FREQUENCY TESTING OF GIS INCLUDING ARRANGING OF HV TEST KIT ALONG WITH OPERATOR |
| 117 | SERVICES- ONLINE GAS MONITORING SYSTEM INCLUDING LOCAL MONITORING DISPLAY UNIT, HMI PANEL FOR GIS: SUPERVISION OF INSTALLATION, TESTING & COMMISSIONING |
| 118 | SERVICES- 400KV GIS : INSULATION CO-ORDINATION STUDIES FOR GIS SYSTEM |
| 119 | SERVICES- 400KV GIS : TRAINING FOR GIS AT MANUFACTURER WORKS & DESIGN OFFICE |
| 120 | SERVICES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SERVICES: (UNIT PRICES OF INDIVIDUAL SERVICES INCLUDED HERE ARE REQUIRED FOR ANY ADDITION/DELETION OF EQUIPMENT AND REPLACEMENT OF DAMAGED ITEMS. VENDOR TO ENSURE THAT THE UNIT PRICES HAVE A LOGICAL RELATIONSHIP WITH PRICES OF ASSEMBLIES IN MAIN ITEMS. QUOTING FOR UNIT PRICES IS MANDATORY AND SHALL BE CONSIDERED FOR EVALUATION) (For item sl. nO. 6.01-6.05):SERVICES- 400KV GIS: REF. UNIT PRICE OF GIS INDIVIDUAL ITEM/ EQUIPMENT - SERVICES FOR SUPERVISION OF ERECTION OF GIS |
| 121 | SERVICES- 400KV GIS: REF. UNIT PRICE OF GIS INDIVIDUAL ITEM/ EQUIPMENT - SERVICES FOR TESTING & COMMISSIONING OF GIS |
| 122 | DEMOBILIZATION AND REMOBILIZATION CHARGES |
| 123 | SERVICES- 400KV GIS: DEMOBILIZATION AND REMOBILIZATION CHARGES FOR GIS ERECTION SUPERVISION TEAM |
| 124 | SERVICES- 400KV GIS: DEMOBILIZATION AND REMOBILIZATION CHARGES FOR GIS TESTING & COMMISSIONING TEAM |
| 125 | SERVICES- 400KV GIS: DEMOBILIZATION & REMOBILIZATION CHARGES OF HV TEST KIT ALONG WITH OPERATOR |