| 1 | INTERIOR /CIVIL WORK |
| 2 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material within 50 meters lead as directed by Engineer-in-charge |
| 3 | Dismantling aluminium, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material within 50 meters lead as directed by Engineer-in-charge |
| 4 | Fixing of the removed toughen glass door, including creating the slot for the door spring at the bottom of the toughen door, and fixing of all fittings and accessories removed previously |
| 5 | Providing & Fixing in position Acoustical partition, partly laminated partly glaze (finished in laminate on both the sides for part area and toughened glass 12mm thk. as per design) Acoustical partition made from 12mm w p Plywood & 1mm laminate on both side, 50x50mm teak wood of 600x600c to c having teak wood supports from wall of required length, in front of 1000 Gsm synthetic wool 50mm thick including cost of required Cut-Outs, decorative mouldings/ finishing-items / pain & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects. including all materials labour, finishing etc complete. Laminate to be of Merino(Micro line) range. (Note : Fosted glass film matching with existing pattern has to be provided by vendor only) |
| 6 | Providing & Fixing in position, Acoustical partition made from 12mm w p Plywood & 1mm laminate on both side, 50x50 mm commercial-wood frame of 600x600 c to c having wooden supports from wall of required length, infront of 1000 Gsm synthetic wool 50 mm , including cost of required Cut-Outs, decorative mouldings / finishing-items/paint & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects. including all materials labour,finishing etc complete |
| 7 | Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum centre to centre distance of 600 millimetre perimeter channel and intermediate channels at maximum centre to centre distance 1200 millimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 millimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. |
| 8 | Providing and Fixing Mineral Fibre Acoustical Suspended Ceiling System with Fine Fissured (Bevelled Tegular) Edge Tiles of size 15mm Exposed Grid. The tiles should have Humidity Resistance (RH) of 99%,NRC 0.6, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 16mm , with Recycled content of 31 %. The tile shall be laid on pre-coated G.I channel height of 32 with 15 mm wide T - section flanges colour white having rotary stitching and XL2 CLIP on all T sections i.e. the Main Runner, 1200 mm and 600 mm Cross Tees with a web height of 32mm and a load carrying capacity of 7.57 Kilograms/M2 and pull out strength of minimum 100 Kilograms.. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system, etc. complete (Pattern to be matched with existing false ceiling pattern) |
| 9 | Providing and fixing 12mm toughened glass door with required fixtures and fittings like floor mounted spring, Handles and frosted films matching with existing pattern etc completed |
| 10 | FURNITURE ITEMS |
| 11 | Modular Linear Workstation of Size 1200(L) X 600(W): Supply and installation of above workstations with minimum 70mm thick 1200 mm high panels at partition (side panels shall be attached). With combination of two separate metal raceways for data and power at bottom, two intermediate fabric blocks, top tile-white board, fabric magnetic. The 35 mm thick Pre-laminated particle board support for top wiring at both sides of workstation shall be provided. The table should be complete with suitable keyboard holder tray. The cutouts for 6 Module for power (2no\"s)and 2 Module (1no\"s) for network point is to be there. The cable groomer/raceway is to be provided for data routing as well as data cables. The sample/drawing has to be approved by client before delivery. The OEM should be BIFMA Certified.(Refer drawing section) Notes: 1) Material of table top-Worktop should be made of 25mm thick Pre-laminated particle board. 2) Material for tiles for top: Fabric magnetic (over GI sheet) plus white board3) Material of bottom tile: Metallic (GISheet)4) Plain edge banded with 2mm PVCTape |
| 12 | Supply and installation of Top supporting pedestal with flat metal front of total Size 390W x 585D x 725H (Including leveller) 3dr. of std. size, central locking. The OEM should be BIFMA Certified. (Refer drawing section) Note: 1) The top supporting pedestal should be from the same OEM of modular workstation. 2) The material of pedestal shall be CRCA sheet of minimum 0.8 mm (Bottom & body shell thickness), stiffener -1.2 mm, Drawer front - 0.8mm in powder coated finish (seven tank processes) per approved colour. |
| 13 | Providing Godrej Finness table 5026 in size of 1500x750 with ERU 3616 and 3 door steel pedestal. (GODREJ INTERIO Executive Table of three layer pre-laminated particle board(Godrej Product) of IS 12823/Laminate 1500 millimetre 750 millimetre 750 millimetre(GODREJ INTERIO FINNESSE S026 PLAIN TABLE + ERU 3616) 1)Table top: 3 layer 40 mm thick pre-laminated particle board (Wood Product) of IS 12823/1st test. 2)Leg Material-NO LEGS 3)Thickness of table top 25 millimetre 4)Length of table 1500 millimetre 5)Depth of table 750 millimetre 6)Height of table 750 millimetre 7)Warranty period in number of years1 8) Product shall be ISO 9001:2015, ISO 14001:2015, ISO 18001:2007 certified |
| 14 | Dismantling of existing installed Godrej modular workstations (Penta Model) and refixing at the position at desired location inside HR department as per the approved layout/ drawing as instructed by Engineer in Charge) |
| 15 | Dismantling of existing installed Godrej modular workstations and refixing at the desired location inside building as per the approved layout/ drawing as instructed by Engineer in Charge). |
| 16 | ELECTRICAL AND ALLIED WORKS |
| 17 | Supply & Installation of concealed / reassessed RAW/UPS point wiring using 600V 3R (P+N+E) x 1.5 Sq.mm copper conductor PVC insulated wires (with proper R,Y,B color code) pulled through PVC raceway on walls and through table partitionincluding 3R (P+N+E) x 2.5 Sq.mm circuit wires from the relevant DB and also including 2.5 sqmm green color copper earth wire and approved make modular type switch plate, switches, MS concealed back box, etc. as required & as approved by the consultant.(The item rate shall include Lighting / Raw / UPS Power Circuit wiring from relevent DB to the switch board with 3Rx2.5 Sq.mmwires & from switch board to next switch board OR to the first light point / primary point / full point)NOTE :- 1. OnlyPVC insulatedwire shall be used; 2. Conduit carrying circuit wiring should not carry point wiring and Conduit carrying point wiring should not carry submain/circuit wiring; 3. Flexible conduits & Elbows are not allowed; 4. The wires from ceiling junction to light points / light fixture shall be drawn in flexible PVC conduit/Cassing caping with adptor & cover for junction box & crimp type lugs at both the ends alongwith necessary hardware & accessories, etc. as required; 5. Proper ferrules, lugs, must be used in all cabling and wiring on both load / source end; 6. Each switch board must be provided with respective ferrules representing the respective DB, Phase & Circuit numbers; 7. Looping of Neutral / Earth wire between two separate Primary / Full Points is strictly not allowed; 8. Looping of Neutral / Earth wire between two separate circuits on similar or other phase is strictly not allowed; 9. Feruling / numbering / tagging to wires with circuit number & db name for all lighting & raw / ups power shall be strictly followed at both DB & switch board / switch socket boards ends. |
| 18 | Supply & Installation of primary point wiring for UPS or stabilized power plug points on workstations / table for computers using 3C X 2.5 Sqmm copper conductor PVC sheathed white color flexible cable pulled through already laid Surface PVC Box raceway andtable/workstation partition raceways and taken upto table top using PVC rigid or flexible conduits run within wooden/metal partitions. Each point consisting of 2 nos of 5A , 3 pin sockets above table top/bottom & 2 No of10ACONTROLLING Switch , wired together forming one point. The earth wire of 3 core flexible cable to be of yellow-green colour only. |
| 19 | Supply & Installation of Secondary point wiring for UPS or stabilized power plug points on workstations / table for computers using 3C X 2.5 Sqmm copper conductor PVC sheathed white color flexible cable pulled through already laid Surface PVC Box raceway andtable/workstation partition raceways and taken upto table top using PVC rigid or flexible conduits run within wooden/metal partitions. Each point consisting of 2 nos of 5A , 3 pin sockets above table top/bottom & 2 No 10ACONTROLLING Switch , wired together forming one point. The earth wire of 3 core flexible cable to be of yellow-green colour only. ( Maximum 2 no.spointto be looped from each primary UPS point ) |
| 20 | Supply & Installation of primary point wiring for RAW power plug points on workstations / table for computers using 3C X 2.5 Sq.mm. copper conductor PVC sheathed white colour flexible cable pulled through new Surface PVC Box raceway andtable/workstation partition raceways and taken upto table top using PVC rigid or flexible conduits run within wooden/metal partitions. Each point consisting of 2 nos of 5A , 3 pin sockets above table top/bottom & 2 No of15ACONTROLLING Switch , wired together forming one point. The earth wire of 3 core flexible cable to be of yellow-green colour only. |
| 21 | Supply & Installation of Secondary point wiring for RAW power plug points on workstations / table for computers using 3C X 2.5 Sqmm copper conductor PVC sheathed white color flexible cable pulled through already laid Surface PVC Box raceway andtable/workstation partition raceways and taken upto table top using PVC rigid or flexible conduits run within wooden/metal partitions. Each point consisting of 2 nos of 5A , 3 pin sockets above table top/bottom & 2 No of15ACONTROLLING Switch , wired together forming one point. The earth wire of 3 core flexible cable to be of yellow-green color only. ( Maximum 2 no.spointto be looped from each primary UPS point ) |
| 22 | DATA NETWORKING |
| 23 | Supply & Installation of Modular Data point including approved make Cat - 6 UTP cable through already laid trenches, and new flexible conduit in table partition ,RJ45 information outlet face plate, etc. with Termination, Testing and Documentation of UTP Points complete as required.(D-Link or equivalent) |
| 24 | Supply of mounting patch cord (3 feet\") |
| 25 | Supply of mounting patch cord (7 feet\") |
| 26 | Supply & Installation of Fully Populated 24 Port Cat 6 Jack panel (D-Link or equivalent) |
| 27 | VOICE/TELEPHONE NETWORKING |
| 28 | Supply & Installation of Telephone /Voice point including approved make Cat - 6 UTP cable through already laid trenches / conduits, RJ11 information outlet, in single face plate, in workstation partition wall etc. with Termination, Testing and Documentation of UTP Points complete as required. |
| 29 | Supply & installation of PVC trucking (2 compartment) of 100 x 50 mm size |
| 30 | Supply & Installation of concealed / reassessed 5/15A RAW point : 5/15A MODULAR switch socket using 3 x 2.5 Sq.mm copper Flexible conductor PVC insulated wires in PVC conduits pipe of 25/20mm dia. concealed in wall (including Chiselling in wall) and or through partitions with necessary boxes, Ceiling rose, 5/15A modular type switch, and socket mounting plate and concealed Metal Box and proper clamping complete.(DB TO POINTS) |
| 31 | Supply&Installationof(26-32W)(2\"X2\")fulllitpaneltypeLED Light fixture, CRI >80,The fitting shall be suitable for grid / plain ceiling type & surface mounted / to be hanged from the ceiling at the height approved by architect. (CGL , PHILIPS WIPRO , GE or equivalent category & model as approved by client / architect / consultant.) |
| 32 | HVAC WORK |
| 33 | Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Note- 1)The ducting connection is to taken by preparation of cut-out in the existing ducting. All necessary cutting, duct joint gasket, nut bolt etc shall in vendor scope2)The neck size of the SA diffuser selection & Floor/AHU CFM balancing is in vendor scope (Thickness 0.63 mm sheet ) |
| 34 | Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. |
| 35 | Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core. |
| 36 | Supplying and fixing of 19 mm thickness duly laminated aluminium foil of mat finish closed cell Nitrile rubber (Class \"O\") insulation on duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. |