Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | M&L Repair to ends of chajjas/ parapets by removing old concrete,loose material &cleaning of the reinforcement and finishing the surface with rich cement mortar 1:3 , finished fair & even and making good with existing finishes complete all as specified and as directed.Note: Rate quoted by the tenderer shall be deemed to inclusive of double steel scaffolding. |
| 2 | M&L for Dismantling/ taking down old existing unserviceable cement plaster, loose/ unsound weaken cement concrete of any description and in any position from existing external / internal surface of RCC roof/ slab/ beams/ columns/ RCC facias for an average depth of 25mm (Approx height 7.5m from natural ground level) with power driven pneumatic flat/pointed chisel and removing the honeycombed area including all the corners and making a neat profile of the cavities, roughen the smooth surface , scrapping out/removing corrosion all loose/scale/rust etc form the visible reinforcement by applying rust remover such as Rust Off 100 of make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s BOSTIk India pvt limited, M/s ThermaxLimited (as approved by GE) and cleaning the steel reinforcement properly all as manufactures and all as specified and directed by Engineer-in-Charge. |
| 3 | (a) Providing cement based angle fillet for 75mm X 75mm admixed with Sikacim, integralwaterproofing liquid M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s BOSTIk India pvt limited, M/s Thermex, (as approved by GE) @ 0.2% by weight of cement or as per manufacturer’sinstructions over a coat of acrylic emulsion bonding agent such as per as Sika Latex in 1:1:3 ratio of Make M/s Sika India Pvt Ltd, or equivalent in M/S Fosrox chemicals, M/s BOSTIkIndia pvt limited, M/s Thermex Ltd (as approved by GE) having specific gravity of 1.02 or as per manufacturer’s instructions with necessary surface preparation such as creating mechanical key like roughing the surface by scrabbing, grit blasting and cleaning the existing surface using high pressure water jet machine having pressure upto 500 barpressure to remove the dirt, dust, loose particles , wax, efforencene and other contaminations from the surface of RCC columns/ beams/ slabs/ facia/ any brick/ stone surfaces etc all as manufactures and all as specified and directed by Engineer-in-Charge. |
| 4 | (b) Providing and applying FRIAZINC R, corrosion inhabiliting Active Zinc rich primer of make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s BOSTIk India pvt limited, M/s Thermex Ltd (as approved by GE) along the exposed reinforcement surface property and allowed to dry. |
| 5 | (c)Providing and applying Hibond, Epoxy based Thixotropic bonding adhesive of Make of M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s BOSTIk India pvt limited ( as approved by GE) over the prepared concrete surface to get a good bonding between existing concrete surface and providing Sika Rep Microcrete 4 Fiber reinforced cementitious repair micro concrete of make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s BOSTIk India pvt limited, M/s Thermex Ltd ( as approved by GE) over Epoxy based bonding agent applied area before 6 Hrs etc including providing necessary proportions , bracing and runners to relieve the member from the load coming on it including scaffolding leak proof shuttering with working platform as required and as per design and pattern complete including preparing the surface to match with the existing surface all as specified and directed. |
| 6 | (d) Note : The work under (Item No. 2 to Item No. 5 of BOQ) shall be carried out through authorized and qualified applicators of the any following manufacturer only. MOU to be submitted before commencement of work.M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s BOSTIk India pvt limited, M/s ThermaxLimited |
| 7 | (i)A performance guarantee certificate for two years shall be submitted by the contractor to the GE on completion of work as specified. |
| 8 | (ii) The unit rate quoted for item No. 1 to 5 of BOQ is deemed to be included for Removing of accumulated earth of any width and depth upto 15 cm cleaning/cutting the grass with hand operated petrol/kerosene driven grass cutting machine and removing the grass waste around 3 m from plinth protectionto outside MD land Note: Periodicityof cutting of grass shall be before commencement of work and after completion of repairs. |
| 9 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided (reinforcement cut as required to facilitate demolition) complete all as specified and directed. |
| 10 | M&L RCC, type B0 1:2:4 (12.5mm graded stone aggregate) as in floor/roofSlab and roof projectionSlabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like similar work complete all as specified and directed. |
| 11 | M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, column, beam landings and similar work n exc 200mm thick complete all as specified and directed. |
| 12 | M & L mild steel TMT bar 10mm dia and over cut to length bent to shape as required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-S complete all as specified and as directed. |
| 13 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on planand getting out any type of soil complete all as specified and as directed. |
| 14 | Excavating in trenches, exc 1.5 m depth and n exc 3.0 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on planand getting out in any type of soil complete all as specified and as directed. |
| 15 | Removing excavated soil material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed. |
| 16 | Returning, filling including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed. |
| 17 | M&L forPCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation filing and mass concrete complete all as specified and directed. |
| 18 | M&L Reinforced cement concrete (Design Mix- M25) in (20mm graded aggregate) Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete |
| 19 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter |
| 20 | M & L mild steel TMT bar 8mm dia and over upto and including 10mm dia as in stirrups, spacers and binders, cut to length bent to shape as required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-S complete all as specified and as directed. |
| 21 | M & L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161 1979 grade St.-240 including all necessary nut, bolts, washers etc complete all as specified and as directed. |
| 22 | M&L Plates Fe 410 -W (Gde- E- 250) quality- A (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes,with riveted, bolted or welded attachment complete all as specified and as directed. |
| 23 | M&L for preparation of new surfaces of steel or iron surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat red oxide primer complete all as specified and as directed. |
| 24 | M&L mild steel Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290, Gde-E-165 complete all as specified and as directed. |
| 25 | M&L Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick (AZ-150) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws in curve manner or as per the truss design all as specified and directed |
| 26 | M&L Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick (AZ-150) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws in curve manner or as per the truss design all as specified and directed |
| 27 | S & F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/post, bore of pipe 200 mm with MS clamps and saddles complete all as specified and as directed |
| 28 | S & F PVC (SWR) bends of any radius with access door bore of pipe 200 mm complete all as specified and as directed. |
| 29 | Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 30 | M&L plain cement concrete 1:2:4,type B-1 using 20 mm graded stone aggregate 150mm thick, surface finished even and fair as in mass concrete for pavings, hardstandings and similar work etc complete all as specified and as directed. |
| 31 | M&L 15 mm thick cement plaster in CM 1:4 on external surfaces on brick or concrete surfaces using waterproofing compound as per manufacturer\"s instructions complete all as specified and directed. |
| 32 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over & including 1.5mm thick external putty new/old surfaces complete all as specified and directed. |
| 33 | Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and as directed. |
| 34 | M&L for machine pressed pre polished precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness, M-40 Grade over sand cushion with grey cement and no pigment all as specified and directed. |
| 35 | M&L for Hardcore of broken stone/boulders gauge n exc. 63mm, deposited, spread & levelled in layers n exc. 15 cm thick, watered & rammed to a true surface complete all as specified and directed. |
| 36 | M&L75 mm thick, Cement concrete 1:3:6type C-2 using 40 mm graded stone aggregate as in pavings, hardstandings and similar work etc, surface finished even and fair without using extra cementall as specified and directed.. |
| 37 | Material and labour for sand filling under precast interlocking paver blocks and all other similar workscomplete all as specified and directed. |
| 38 | Material and labour for PCC1:2:4 type B1 (using 20mm graded stone aggregate) as in bed plates, including weathering, slightly rounded or chamfered angles and throating, coping,flooring etc including necessary form work completeall as specified and directed. |
| 39 | M&L Repairto door shutters for easy closing/opening(size upto 3 Sqm) including minor repair and easing, adjustment/alignmentto openable with assessories and including taking down and refixing, tightening of hinges or changing the position of hinges,welding of hinges door to frame adjustment of tower bolts, sliding bolts with new screws etc,complete all as specified and directed. |
| 40 | Taking down chowkats or frames (wooden/steel)including shutter (without taking off shutters from the frame) area n exc. 1.5 Sqm each all as specified and as directed. |
| 41 | Taking down chowkhat or frame (wooden/steel) exceeding 1.50 Sqm and not exceeding4.0 Sqm each with shutter (with out taking off shutters from the frame) all as specified and as directed. |
| 42 | Taking down shutters of any description exc 1.0 Sqm andn.exc 2.0 Sqm each complete all as specified and directed. |
| 43 | M&L Second class hard wood plain, solid, straight Chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at jointscomplete all as specified and directed. |
| 44 | S&F 2nd class hard wood 35mm thick Factory made plain framed panelled shutter any number of panelswith lock rail and panel of 9mm BWP commercial ply or 12mm veneered partical board with commercial veneering on both faces. The size of rail and stile as per IS 1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 45 | S&F Factory made 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters all as specified and directed. |
| 46 | S&F Aluminium, anodised, barrel tower bolts 200mm long of extruded section all as specified and directed. |
| 47 | S&F Aluminium alloy, anodised, sliding door bolt 300mm long with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections & fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed. |
| 48 | S&F Aluminium handles 150mm size, cast type, anodised all as specified and directed |
| 49 | S&F overall length of cover plate 150mm long Floor door stopper of aluminium alloy body & tongue, anodised, with hard drawn steel spring fixed in floor complete all as specified and directed. |
| 50 | S&F 100mm butt hinges stainless steel medium weight complete all as specified and directed. |
| 51 | M&L Preparation of new wooden surfaces over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 52 | S&F frosted glass4 mm thick ordinary quality and glazing complete in square n exc 0.50 Sqm in each pane complete all as specified and directed. |
| 53 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm complete one all as specified and directed. |
| 54 | M&L Hacking out old broken glass (any thickness, size, quality or description) from wooden frames/steel frames/UPVC frames glazed with putty or fixed with beads and material and labour for4mm thick plain sheet glass ordinary quality and glazed with oil putty or fixed with fillets 2nd class hard wood of sectional area not exc 3 Sqcm and glass not exc 0.5 sqm in each pane complete all as specified and directed. |
| 55 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm complete including taking down existing one from UPVC/wooden frame all as specified and directed. |
| 56 | M&L Repairto easing of wooden window, wooden ventilator, cupboard door, wardrobe door,PVC door, window shutters, kitchen cupboard shutters, show case shutter drawers including fixing of screws adjusting handles, knobs tightening piano hinges including misc small adjustments , (size upto 3 Sqm). minor repair and easying and adjustment/alignmentto openable with accessories and including taking down and refixing complete all as directed. |
| 57 | S&F 4 mm thick sheet glass ordinary quality and glazing complete in square n exc 0.50 Sqm in each pane complete all as specified and directed. |
| 58 | S&F 4 mm thick sheet glass ordinary quality and glazing complete in square exc 0.50 Sqm in each pane complete all as specified and directed. |
| 59 | M&L 20mm dia mild steel powder coated drapery rod cut to length required without joint in between and including mild steel powder coated fancy type brackets and fixed at openings including taking down existing one complete all as specified and directed. |
| 60 | S&F in repairs 250mm, ordinary mild steel rat tail rod pattern door springs including roller and roller plate complete all as specified and directed. |
| 61 | S&F Aluminium body door closer hydraulically regulated,designation No.3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed including taking existing one complete as directed. |
| 62 | S&F in repair looking mirror of size 600mm x 450mm on commerical ply wood 6mm thick with PVC/ wooden moulding beading fixed to wooden plugs with chromium plated brass, screws and cup, washers, aluminium frame and fixed complete all as specified and directed. |
| 63 | Complete removal of existing treatment ofold walls and washing, rubbing down, and applying plaster of paris putty of 1mm thickness over plastered surfaces to prepare the surface even and smooth painted surfaces and applying two coats of oil bond distemper over a coat of primer complete all as specified and directed. |
| 64 | M & L for preparation of old painted wooden surfaces of anydescription, not otherwise described, exceeding 10cm inwidth or girth and applying one finishing coat of synthetic enamelpaint on wooden surfaces, complete all as specified and directed. |
| 65 | M & L for preparation of old painted steel and iron surfaces of any description exceeding 10 cm in width or girth and applying one finishing coat of synthetic enamel paint on steel surfacescomplete all as specified and directed. |
| 66 | Material and labourfor Preparation of old decoratedplastered or unplastered surfaceof wall, chajja, balcony, facia etc., brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent, trading, oil, greasy spots and applyingone coat of whitewashcomplete all as specified and directed. |
| 67 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed. |
| 68 | Material and labourfor 25 mm thick PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in flooring surface as in level course etc complete all as specified and directed. |
| 69 | M&L Machine cut kota stone slab 20-25 mm thick as in flooring, laid over and incl 20 mm thick screed bed in CM 1:3 set and jointed in neat cement slurry and pointed with cement and pigment to match the shade of the slab including rubbing and polishingcomplete all as specified and as directed. |
| 70 | M&L Machine cut kota stone slab 20-25 mm thick as in n skirting / dado / vertical surface laid over cement screed and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete over backing coat 15mm thick in CM 1:3/ necessary addisive complete all as specified and as directed. |
| 71 | M&L Repair to leakage/seepage from the Nahani trap/ floor trap of kitchen/ bathroom/ washbasin of the upper Qtr, in any position at any height, complete including change of floor trap, PVC horinzontal pipe embeded in floor in bathroom or kitchen making good to the damaged portion of flooring, laying and matching of tiles in the existing flooring, complete all as specified and directed |
| 72 | M&L Repair to leakage/seepage from the wall/ door bend /door tee/\"Y\" junction/ \"T\" Junction of soil pipe / waste pipe/ vent pipe of kitchen/ bathroom/WC of the upper Qtr or at the ground floor Qtr including change of any damaged soil waste pipes or fittings of any shape, specification and size, making good to the damaged portion of wall with brick work in cement mortar 1:6 or cement concrete 1:2:4 and plastering to wall in CM 1:4 and finished the surfaces matching to existing wall to avoid the leakage/ seepage at the site of work complete all as specified and directed. |
| 73 | Note for item No 71 & 72:- (a)Find out main cause of leakage and take necessary steps to resolve / rectify.(b)Replace existing tiles in case leakage through NT/FT.(c)The rate also include provision of new NT/FT.(d)The unit rate is also deemed to be included for reqd bonding chemicals to arrest the leakage/seepage as directed by the manufacturer\"s specification. Make : M/s Sika Chemical, M/s Pidilite, M/s Dr Fixit |
| 74 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/trenchesbore of pipe 110 mm with PVC clamps and saddles including taking down old existing pipes and dismantling of cast iron/RCC/PVC drain pipes jointed in cement mortar and taking out from trenches or walls of any bore including fittings complete all as specified and as directed |
| 75 | S&F in repairs PVC (SWR) bends of any radius with access door bore of pipe 110 mm complete all as specified and as directed. |
| 76 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/trenchesbore of pipe 75 mm with PVC clamps and saddles including taking down old existing pipes and dismantling of cast iron/RCC/PVC drain pipes jointed in cement mortar and taking out from trenches or walls of any bore including fittings complete all as specified and as directed |
| 77 | S&F in repairs PVC (SWR) bends of any radius with access door bore of pipe 75 mm complete all as specified and as directed. |
| 78 | S&F in repairs PVC vent cowl 75 mm bore complete all as specified and as directed. |
| 79 | Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) and removing rubbish off from premises & M&L forceramic coloured tiles of size 350mmx250mm/ 300mm X 450mmx7 to 8 mm thick, on vertical surfaces, set and jointed in neat cement slurry and pointed in coloured / white cement to match the tiles inc rendering 10mm thick in CM 1:4 on fair faces of brick work or concrete surfaces as in backing coat to receive wall tiles etc complete all as specified and directed. |
| 80 | Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) and removing rubbish off from premises & M&L for joint free non skid coloured ceramic tiles 7 to 8 mm thick area of each tile not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointedin white or coloured cement to match incl 15 mm thick screed bed in cement mortar 1:4 for layingfloor finishes complete all as specified and directed. |
| 81 | Removing plant/Uprooting of vegetation growth including roots on wall/roof/parapet near pipes etc and applying acid treatment afterremoving roots for preventing regrowth and making good disturbed surfaces/area in superficial area exc 150sq.cm but n.exc 400 sq.cm and averaging depth not exceeding 10 cm by using PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) or 10mm thick plastering in cement mortar 1:3 as required and finishing the surfaces to match with the existing surface complete all as specified and directed. |
| 82 | Taking down cement plaster on brick or stone walls, or concreteetc., including raking out joints, hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises and leaving the work clear of any plastering Material and labour for Rendering 15 mm thick in two layers onbrick or stone or concrete surfaces,first coat 10mm thick in cement mortar1:4 and 2nd coat 5mm thick in cement mortar 1:4 using WPC as per manufacturer instructions finished even and smooth without using extra cement completeall as specified and directed.Note :-(a) The unit rate quotedis deemed to include for removal of accumulated earth of any width and depth upto 15 cm cleaning/cutting the grass with hand operated petrol/kerosene driven grass cutting machine and removing the grass waste around 3 m from plinth protectionto outside MD land. |
| 83 | Taking down cement plaster on brick or stone walls, or concrete walls including raking out joints, hacking for key, scrubbing down with water, etc.,including removal of rubbish off the premises and leaving the work clear of any plastering and material and labour for 10mm thick cement plaster in CM (1:6) on brick work or concrete surfaces rendering is to be even & smooth without using extra cement complete all as specified and directed. |
| 84 | Taking down cement plaster on brick or stone walls / ceiling , or concrete walls/ceiling including raking out joints, hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises and leaving the work clear of any plastering and material and labour for 5mm thick cement plaster in CM (1:3) on brick work or concrete ceiling surfaces incuding finishing even & smooth without using extra cement complete all as specified and directed. |
| 85 | Supply only Integral liquid waterproofing compound of approved make (ISI marked) complete all as specified and directed. |
| 86 | Material & Labour for applying Two or more coats of exterior emulsion weather proof paintincluding priming coat of exterior primer applied over new surfaces complete all as specified and as directed. |
| 87 | M & L for preparation of new plastered surfaces of walls applying 1mm thick wall care putty over plastered surface to prepare the surface even and smooth and applying two finishing coat of oil bound distemper over a coat of primer complete all as specified and directed. |
| 88 | M&L applying two coat of cement based paint over a coat of primer, including preparation of newly plastered wall surfaces of any description, complete all as specified and as directed. |
| 89 | M&L preparation of newly plastered surfaces of ceiling and applying three coats of white washing on ceiling surfaces complete all as specified and directed. |
| 90 | M&Lin repairs Pre-cast PCC 1:3:6 type C1 (using 20 mm graded stone agg) cement concrete block masonry with solid blocks exc. 10cm in width and set in cement mortar 1:6 including demolition of old brick work / stone masonry/PCC block built in cement mortar of any description complete all as specified and as directed. |
| 91 | M&L for rendering 15mm thick in cement mortar (1:4) on brick or concrete surfaces of wall and finishing the surface even and smooth without using extra cement complete all specified and directed. |
| 92 | M&L preparation of newly plastered surfaces of wall and applying three coats of white washing on wall surfaces complete all as specified and directed. |
| 93 | M&L in repairs Providing precast cement concrete louvres and jallies, 35mm thick (measured solid) set in CM 1:4, type B0 1:2:4, faces are finished smooth including demolition of old mouldings complete all as specified and directed. |
| 94 | Supply and fixing 15mm bore galvanized steel water tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down old steel tubing complete all as specified and directed. |
| 95 | Supply and fixing 20 mm bore galvanized steel water tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down old steel tubing complete all as specified and directed. |
| 96 | S & F in repairs viterous china wash down water closet (Pedestral pattern) EWC white incl plastic water closet seat cover and mild steel chromium plated or aluminium hinging device and connecting to \"P\" or \"S\" trap incl connecting flush pipe with flushing rim complete all as specified and as directed. |
| 97 | Supply and fixing in repairs plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device all as specified and directed. |
| 98 | S & F in repairs Bib taps cast copper alloy chromium plated fancy type screwed down screwed foriron pipe or for brass ferrule and fixed for 15 mm bore complete all as specified and as directed. |
| 99 | S & F in repairs pillar tap with capstan heads chromium plated fancy type screwed down high pressure with or withoutletter \"Hot\" or \"Cold\" with long screwed shanks and flynuts screwed for galvanised iron pipe and fixed complete for 15 mm bore complete all as specified and as directed. |
| 100 | S & F in repairs 15 mm dia stop valve/angle valve of cast copper alloy fancy type chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and as directed. |
| 101 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 meter long flexible tube and ABS wall hook including taking down existing one complete all as specified and as directed. |
| 102 | S&F in repairs 40mm bore unplasticised PVC pipe of pressure rating 10 kg/Sqcm fixed complete to walls, ceiling or laid in floors complete all as specified and directed. |
| 103 | Taking down & re fixing high or low level flushing cistren 10 ltrs capacity & connections to pipes & fixing of chain & pull or lever after cleaning inside of all dirt, scale formation, replacement and including rubber washers, syphon set, float valve, handle,fixing to wall clamp/bracket, stopping of leakage etc wherever required complete all as specified and as directed |
| 104 | S&F in repairs, 10 litre capacity PVC flushing cistern, syphonic action type, low level, white, with inlet, ball valve,pvc flush pipe, float and handle incl brackets and waste pipe complete all as specified and directed. |
| 105 | S&F 300mm arc size, 5mm thick corner glass shelf with stainless steel brackets, stainless steel railing in bathroom and fixed to wall with brackets including removing the existing fitting as required at site complete all as specified and as directed |
| 106 | S&F Towel Ring round including taking down existing one complete all as specified and as directed. |
| 107 | S&F in repair Chromium platedsoap dishincluding fixing arrangement complete all as specified and directed . |
| 108 | S&F in repair PVC gully/floor trap 125/110 mm dia, with stainlesss steel grating including jointing to waste pipe fixed in solvent cementall asspecified and directed. |
| 109 | S&F in repairs Wash basin vitreous china (flat back or angle back type) size 580x400mm including taps wastechain and plug and porceline stopper but brackets including cutting for and pinning inends of brackets or erecting stand with waste pipe, complete all as specified and directed. |
| 110 | Supply and fixing 25 mm bore galvanized steel water tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down old steel tubing complete all as specified and directed. |
| 111 | Supply and fixing 40 mm bore galvanized steel water tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down old steel tubing complete all as specified and directed. |
| 112 | Cutting chases pinning in making good to facing where required for concealed water tubing any size and making good with CM 1:3 cutting not exc 10cm girth in brick/stonewalls complete all as specified and directed. |
| 113 | Petty repair to wall mixer,basin mixer,sink mixer etc including replacement of spindle brass, Jumper brass, rubber washer, head incl taking down and refixing etc completeall as specified and directed |
| 114 | Supply and fixing in repairs 20mm dia gun metal gate valve with iron wheel screwed both ends for iron pipe all as specified and directed. |
| 115 | S&F CP Concealed stop cock, Regular body with adjustable wall flange screwed down screwedfor iron pipe15mm bore.including taking down existing one complete all as specified and as directed. |
| 116 | S&F in repairs Overhead Shower rose 125mm size (Brass Chrome Plated)complete all as specified and as directed. |
| 117 | S & F in repairToilet paper holder box type of vitreous china fixed to walls with chromium plated (CP) brass screwsand complete all as specified and as directed. |
| 118 | S & F in repair PVC waste pipe 32 to40mm for WHB/Sink up to floor trap and fixed complete all as specified |
| 119 | S&F in repairs CP 2 way bib cock with wall flange fancy type screwed down screwedfor iron pipe in repairs 15mm bore complete all as specified and as directed. |
| 120 | S&F in repair Brass Chromium plated wall mixer for mixing hot & cold water screwed down for 15mm bore iron pipecomplete all as specified and directed. |
| 121 | S&F in repairs 32mm bore unplasticised PVC pipe of pressure rating 10 kg/Sqcm fixed complete to walls, ceilingor laid in floors complete all as specified and directed. |
| 122 | S &Fin repairs PVC connection pipe 15 mm dia, 600 mm long with check nut and bolt with washer complete all as specified and as directed. |
| 123 | S & F in repair tubular towel rail brass chromium plated 20 mm dia \"D\" type 60 cm long between flangescomplete all as specified and as directed. |
| 124 | M&L Repairto refixing the existing Wash hand basin and Sinks made of stainless steel 1mm thick kitchen flat back with including fixing cantilever CI/Angle iron brackets embedded in concrete block including connecting waste coupling 32mm bore, including bedding, waste fitting, waste pipe in cement mortar on to dwarf wall and connecting union to pipe, filling gap in white cement and all neccessary fittings to fixed in repair(including taking down and refixing the same in position) complete all as specified and directed. |
| 125 | Material and labourfor Preparation of old decoratedplastered or unplastered surfaceof wall, brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , trading, oil, greasy spots and applying one coat of cement based paint complete all as specified and as directed. |
| 126 | M&L for preparation of old plastered surfaces by complete removal of existing treatment ofold walls by using pressure washer and removal all dirt and dust and applying two coat of exterior emulsion weather proof paintover a coat of exterior primer complete all as specified and as directed. |
| 127 | Material and labourfor Preparation of old plastered or unplastered surfaceof ceiling brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , trading, oil, greasy spots and applyingone coat of white wash complete all as specified and directed. |
| 128 | M & L preparation old surfaces ofexterior wall decorating and water proofing treatment to wall surface by wire brushing in order to remove dust, dirt, loose particles, laitance. Thereafter wash the surface with clean water & allow to dry. Fill visible cracks/ joints by smart care crack sealer caulking compound & allow to dry for 24 hours. Apply a primer coat of (apex ultima protek base coat) and allow to dry for 6 hours. Thereafter apply 02 coats of Weather coat (apex ultima protek top coat or equivalent) & shade by brush at the interval of 08 hours between the coat and allow to dry to match the existing shade including necessary scaffolding for any height, covering etc complete all as per specified and directed. |
| 129 | M&L Repairto renewing/matching glazed or ceramic coloured tilesin floors/walls in patches area not exceeding 1.00 Sqm including dismantling, removing and cleaning old tiles preparing beds and laying screed bed in CM 1:4 setting, jointing and pointing new or old tiles and joints filling and apply white cement complete all as specified and directed |
| 130 | M&L Vitrified Ceramic tiles 10 mm thick, (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over andincluding screed bed or bedding layer, 15 mm thick in Cement Mortar (1:6)complete including dismantling of existing old tiles and disposal to outside MD land all as specified and as directed. |
| 131 | M&L Vitrified Ceramic tiles 10 mm thick, (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in vertcal surfaces such as skirting/ dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over andincluding screed bed or bedding layer ,15 mm thick in Cement Mortar (1:4)complete including dismantling of existing old tiles and disposal to outside MD land all as specified and as directed. |
| 132 | M & L for 75 mm thick PCC type C1, 1:3:6 (20 mm graded stone aggregate) as in plinth protectionfinishing the surface even and smooth with using extra cement, including necessary demolition of old concrete all as speecified and as directed. |
| 133 | M&L PCC (1:4:8) type D2 using 40mm graded aggregate 75mm thick as in sub base of floor finished even and rough to receive top layer and including Demolition of old cement Concrete (un reinforced) of any description and in anypositionnot otherwise specifically provided complete all as specified and directed.. |
| 134 | Surface dressing n exc 15 cm deep and getting out in any type of soil complete all as specified and as directed. |
| 135 | Excavation over areas not exceeding 1.5m deep and getting out in any type of soil complete all as specified and as directed. |
| 136 | Excavation over areas exceeding 1.50m deep and not exc 3.00m deep and getting out in any type of soil complete all as specified and as directed. |
| 137 | M&L PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete of any description, complete all as specified and directed. |
| 138 | M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in bed to 150mm dia drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in, all as specified and directed. |
| 139 | M&L Pre-cast PCC 1:3:6 type C1 (using 20 mm graded stone agg) cement concrete block masonry with solid blocks exc. 10cm in width and set in cement mortar 1:6complete all as specified and directed. |
| 140 | M&L 15 mm thick cement plaster in CM 1:6 on fair faces of brick work/concrete etc finished even and smooth without using extra cement complete all as specified and directed. |
| 141 | M & L for Pre-cast reinforced cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate set in cement mortar 1:4 as in cover slab including all necessary form work. Exposed surfaces of concrete shall be finished even and smooth without using extra cement complete all as specified and as directed. |
| 142 | M&L for Broken stone aggregate for loose filling of gauge 40mm size for filling in pits all as specified and directed. |
| 143 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/trenchesbore of pipe 110 mm with PVC clamps and saddles all as specififed and directed |
| 144 | S & F PVC (SWR) bends of any radius with access door bore of pipe 110 mm complete all as specified and as directed. |
| 145 | S & F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/trenchesbore of pipe 150 mm with PVC clamps and saddles complete all as specified and as directed |
| 146 | S & F PVC (SWR) bends of any radius with access door bore of pipe 150 mm complete all as specified and as directed. |
| 147 | M&L mild steel framed work such as grills,gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 all as specified and as directed |
| 148 | M&L 75mm thick PCC type D-2 (1:4:8) using 40mm graded stone aggregate as in sub base to floor surface finished even and fair complete all as specified and directed |
| 149 | M&L100 mm thick, Cement concrete 1:2:4,type B2 using 40 mm graded stone aggregate as in pavings, hardstandings and similar work surface finished even and fair without using extra cement complete all as specified and directed.. |
| 150 | M&L 75mm thick PCC 1:3:6 type C-2 (using 40mm graded stone agg) as in plinth protection finished even and fair without using extra cement, floor shall be laid in alternate panels inluding necessary form work complete all as specified and directed. |
| 151 | Taking down aluminium/copper point wiring & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete and making good the disturbed plaster surfaces of wall, floor, ceilingand painting 2 coat of white wash/distamber to match the existing surface, complete all as specified and directed. |
| 152 | M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn into and including rigid non mettalic PVC conduit/casing caping medium grade not less than 19/20 mm ( ISI marked ) with all fitting and fixing accessories including sunk in pressed steel chromium plated terminal boxes, concealed/surface in wall/roofs/floor/ceiling etc as per site requirement and making & matching the existing surface) white bakelite sheet cover for mounting switches, Sockets, Fan regulators etc or modular cover plate with frame including sunken boxes suitableto fix modular cover plate with frame , concealed in wall and 1.5 sq mm multi stranded copper conductor cable as continuous earth wire drawn with wiring and connected to common earth dolly complete all as specified and directed for the following :- Make of wire: Polycab/Plaza/HavellsNote:Blanking plate,Modular cover plate ,Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely). |
| 153 | All as per item No. 152 here in before but for one light point/fan/bell point controlled by one wayswitch. |
| 154 | All as per item No. 152here in before but for one light point controlled by twowayswitch. |
| 155 | All as per item No. 152 here in before but for one 3 pin socket out 5 Ampon the same board |
| 156 | All as per item No. 152 here in before but for one switch socket outlet 3 pin 5 Amps on independent board |
| 157 | All as per Sl No. 152 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently complete all as specified and directed. |
| 158 | Supply and Fixmodular switch1 way 6 Amp.1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 159 | Supply and Fixmodular switch2 way 6 Amp.1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor /Indoasian |
| 160 | Supply and Fixmodular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 161 | Supply and Fixmodular switch1 way 16 Amp.1 module, complete all as specified and directed. Make :Legrand/ Crabtree/ Anchor /Indoasian |
| 162 | Supply and Fix modular Socket, 16A - 3/5 pin combined 2 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian |
| 163 | Supply & Fix Modular fan regulator 120W, 2 Module for ceiling fan complete all as specified and directedMake : Legrand/ Crabtree/ Anchor/Indoasian |
| 164 | S & F ceiling rose 3 phase/PVC/polycarbonate, isolated body complete all as specified and directedMake : Anchor/Havells/L&T/Indoasian |
| 165 | Supply and fix White cover plate with frame,2/3 module |
| 166 | Supply and fix White cover plate with frame,4 module |
| 167 | Supply and fix White cover plate with frame,8 module |
| 168 | Supply and fix White cover plate with frame,6 module |
| 169 | Supply and Fixing in repairs of 4 feet surface mounted batten type luminaire , lumen output of 2000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability .The luminaire and driver shall be BIS approved, complete all as specified and directed.Make : Philips/ Bajaj / CG/Havells. |
| 170 | M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 Sqmm drawn through in and incl suitable size surface PVC casing caping/PVC Conduit and all accessories fixed to wall/floors along with 6 Sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and directed.Note: (a)2 runs of 6 Sqmm cable along with one run of 6 Sqmm cable for earth conductor shall be measured as one lengthMake:- Havells/ Polycab/ Plaza. |
| 171 | S&F in replacementfactory madepowder coated distribution board VTPN, 8 way double doorMCCB DB includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBcomplete all as directedMake : Indoasian/ Havells/ Legrand. |
| 172 | S&F in replacement distribution board MCCB four pole, 160Amp ultimate breaking capacity 25 KAconforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 173 | S&F in replacementfactory madepowder coated distribution board TPN, 4 way double doorMCBDB includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DBcomplete all as directedMake : Indoasian/ Havells/ Legrand. |
| 174 | S & F in repair and replacement TPN, MCB 40 to 63 Amp, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacitycomplete conforming to IS 8828 of 1996, all as specified Make : Legrand/ L&T/ Indo Asian |
| 175 | Taking down old unserviceable ceiling fan of any size keeping in safe custody complete all as specified and directed. |
| 176 | Refixingexisting serviceable ceiling fans 1200/1400 mm sweep servicing, painting. of ceiling fan with one coat of synthetic enamel paint by spraying including greasing/oiling, fillingcavities with filler after cleaning all dust etc. completeall as specified and as directed. Note : The unit quoted rateincludes replacement of rubber bush ,hanging hook with new cotter pins etc complete. |
| 177 | Supply and fixing in replacement of unserviceableceiling fan 1200mm sweep, energy efficient(ISI mark) withstar rating 230 Volts AC 50 Hz, single phase including provision of fixing arrangement, nut and bolt andflexible copper cable 3 core of size 1.5 sqmm not less than 0.5 m long complete, writing MES No. with synthetic enamel paint all as specified and as directed. Make : Havells/Bajaj/ Orient.Note:-(a)Old Unserviceable ceiling fan shall be deposited to MES store yard. |
| 178 | Supply and Fixing in repairs of 2 feet surface mounted batten type luminaire , lumen output of 1000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability .The luminaire and driver shall be BIS approved, complete all as specified and directed.Make : Philips/ Bajaj / CG/Havells. |
| 179 | Supply and fixing in repair building security/ LED street light fitting 35/36 Watt, 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal, management in multiple optics complete, with IP 65/66 protection complete all as specified and directed. Make: Philips/Bajaj/CG |
| 180 | S&F in replacement factory madepowder coated distribution board SPN 8 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 181 | S & F MCB in repair SPN 240 volts 32-40 Amps suitable for \"C\" curve, 10 KA complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian. |
| 182 | Supply and Fix in repair of switch piano flush type one way 5 Amps, 240 V complete all as specifed and as directed. |
| 183 | Supply and Fix Switch piano flush type one way 15 Amps, 240 V complete all as specifed and as directed. |
| 184 | Supply and Fix in repair of Socket outlet 3 pin 5 Amps, 240 Vflush type complete all as specifed and as directed. . |
| 185 | Supply and Fix in repair Bell push, flush type, 5 Amps complete all as specifed and as directed. |
| 186 | Supply and Fix in repair switch socket combinationoutlet flush type multi purpose 2 in 1, 5 pin 5 and 15 Amp, 230 Volts complete all as specifed and as directed.. |
| 187 | Supply and Fix in repair switch socket combinationoutlet flush type multi purpose 2 in 1, 3 pin 5 Amp, 230 Volts complete all as specifed and as directed. . |
| 188 | Supply and Fix in repair Ding Dong Bell AC, 240 Volts single pole complete all as specified and as directed. |
| 189 | Supply and Fix in repair ceiling rose surface bakelight two to three terminalcomplete all as specifed and as directed. |
| 190 | Supply and Fix in repair Lamp Holder, insulated body, with back plate for batten fittingcomplete all as specifed and as directed. |
| 191 | Supply and Fix in repair Electronic step type Fan Regulator/Mini switch type dimmer 120/280 Watt capacity complete all as specified and as directed. |
| 192 | Supply & fix metal clad switch socket single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A concealed in walls complete all as specified and as directed.Make : Havells/ Indo asian/ Legrand |
| 193 | S & F in repair MCB single pole 240 volts 6 to 32 Amps suitable for \"C\" curve, 10 KA complete including taking down unserviceable fitting complete all as specified and as directed.Make : Legrand/ L&T/ Indo Asian. |
| 194 | Taking down old unserviceable exhaust fan of any size and keeping in safe custody complete all as specified and directed. |
| 195 | Refixingexisting serviceable Exhaust fans 300/225 mm sweep servicing, paintingExhaust fan with one coat of synthetic enamel paint by spraying including greasing/oiling, fillingcavities with filler after cleaning all dust etc. completeall as specified and as directed. |
| 196 | Supply and fixingExhaust Fan 300 mm sweep, 230/240 volt AC single phase, steel body1400 RPM, corrosion less mild steel body of motor, suitable hold fast with necessary nut, bolts / screws with louver, writing MES No. with synthetic enamel paint all specified and directed. Make- Havells /Bajaj/ Almonard.Note:-Old Unserviceable domestic exhaust fan shall be deposited to MES store yard. |
| 197 | M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 Sqmm drawn through in and incl suitable size surface PVC casing caping/PVC Conduit and all accessories fixed to wall/floors along with 4 Sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and directed.Note: (a)2 runs of 4 Sqmm cable along with one run of 4 Sqmm cable for earth conductor shall be measured as one length complete all as specified and directed.Make:- Havells/ Polycab/ Plaza. |
| 198 | M&Lpoint wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 4 sqmm drawing through in and including PVC conduit size of not less than 20mm on surface including provn of metal flush box duly sunken with modular white cover plate with frame of suitable size for mounting modular switch, socket and regulator along with earth wire of PVC insulated, unseathed,1100 V grade cable multi stranded copper conductor of size 4 sqmm all asspecified and directed forOne 3 pin switch socket outlet combination, 15 Amps, independent, with cables 4 sq mm complete all as specified and directed.(Note :Cost for cutting chasing, sunken in the wall for box and making good to disturbed surface all as to match with existing surface are deemed to be included in quoted rate.) |
| 199 | Supply and fixing 20 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc,complete all as specified and as directed. |
| 200 | Supply and fixing 15 mm dia Stop valves, fancy type, chromium plated with long shank and cup(concealed type),screwed down,high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed completeall as specified and as directed. |
| 201 | Supply, install and testing of water heater storage type (Geyser) vertical of capacity 25 Ltr, suitable for high pressure up to 8 barpowder coated metal body, temperature indicating dial , glass line coated tank, magnesium anode,efficient long life copper heating element, wattage 2 KW electrically operated, AC 230 Volt, BEE5 Star Rated with complete fittings/partsand accessories for fixing on wall/surfaceall as per site requirement complete all as specified anddirected Make:- Bajaj / Racold / Havells |
| 202 | S & F of bib tap cast copper alloy chromium plated, fancy type screwed down with screwed both ends for iron pipe 15 mm borecompleteall as specified and as directed. |
| 203 | M & L for Heat resistant PVC baraided connection pipe 15 mm bore with brass copler as in connecting pipe of geyser, Length 300 mm completeall as specified and as directed. |
| 204 | M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 Sqmm drawn through in and incl suitable size surface PVC casing caping/PVC Conduit and all accessories fixed to wall/floors along with 4 Sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and directed.Note: (a)2 runs of 4 Sqmm cable along with one run of 4 Sqmm cable for earth conductor shall be measured as one lengthMake:- Havells/ Polycab/ Plaza. |
| 205 | S&F factory madepowder coated distribution board VTPN, 4 way double doorMCCB DB includingbus bar, Neutral bar, standard DIN rail, earth barcomplete all as specified and directedMake : Indoasian/ Havells/ Legrand. |
| 206 | S&Fdistribution board MCCB four pole, 125 Amp ultimate breaking capacity 16 KAconforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 207 | S&F factory madepowder coated distribution board SPN 8 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 208 | S & F MCBSPN 240 volts 40 to 63 Amps\"C\" series 10 KA breakingcapacity complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian. |
| 209 | M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 Sqmm drawn through in and incl suitable size surface PVC casing caping/PVC Conduit and all accessories fixed to wall/floors along with 6 Sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and directed.Note: (a)2 runs of 6 Sqmm cable along with one run of 6 Sqmm cable for earth conductor shall be measured as one lengthMake:- Havells/ Polycab/ Plaza. |
| 210 | S&F distribution board MCCB four pole, 100 Amp ultimate breaking capacity 16 KAconforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 211 | S&Ffactory madepowder coated distribution board SPN 4 way double door,includingbus bar, Neutral bar, standard DIN rail, earth barconforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian |
| 212 | S & F MCB SPN 240 volts 32 Amps \"C\" series 10 KA breakingcapacitycomplete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian. |
| 213 | Supply and fixing of MCB TP 415 Volts, \"C\" series, breaking capacity 10 KA of rating 40-63 Amps complete all as pecified and directed. Make : Legrand /Schiender/Indo Asian |
| 214 | Supply and fix White cover plate with frame,12 module |
| 215 | M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 2.5 Sqmm drawn through in and incl suitable size surface PVC casing caping/PVC Conduit and all accessories fixed to wall/floors along with 2.5 Sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and as directed.Note: (a)2 runs of 2.5 Sqmm cable along with one run of 2.5 Sqmm cable for earth conductor shall be measured as one length.Make:- Havells/ Polycab/ Plaza. |
| 216 | Supply and fixing LED high baylight 100 watt 230 V AC outdoor type including necessary bracket with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as directed. Make : Halonix/Philips/CG/Bajaj |
| 217 | S & F MCB single pole 240 volts 6 to 32 Amps \"C\" series 10 KA breakingcapacitycomplete all as specified and as directed.Make : Legrand/ L&T/ Indo Asian. |
| 218 | S & FMCB single pole 240 volts 40 to 63 Amps \"C\" series 10 KA breakingcapacity complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian |
| 219 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable, foundation etc, and getting out in soft /loose soil complete all as pecified and directed. |
| 220 | Material and Labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983and as directed. Note :- (i)Excavated approved soil shall be ribbed by using sieve to separate composite particles etc as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable(ii) For the purpose of measurement only punned thickness shall be considered for payment. |
| 221 | Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earthwork, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :-The tenderer shall take into consideration for following points while quoting rate for this item andthe unit rate is deemed to be inclusive for :-(i) Earth work and excavation in any type of soil(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick ,complete all as specified and as directed.(iii) Removing excavated material to out side MD land.(iv)Laying of any type/any bore of pipe in trenches including taking down. Supply of pipe shall be measured and paid separately(v)150 mm thickPCC 1:2:4 type B1 using 20mm graded stone aggregate as inroad to make good existing disturbed surfaces. |
| 222 | Material and Labour for well burnt subclass ‘B’ bricks as mechanicalprotection forunder ground LT electric cables laidalong with length of the bricks equal to the width of the trench complete all as speified and directed . |
| 223 | Supply and Fixing GI tubing light grade 50 mm dia fixed on walls/pole/ laid in trenches as protection pipe for under ground cable including provisioning of specials and clamps etc complete all as speified and directed. |
| 224 | Material and labour forBoring of holes under road, pavement, hard standings by trenchless technology using ultra sound technique and necessary machine including HDPE pipes upto 100 mm dia suitable for 0.4 Mpa working pressure, complete all as specified and directed. |
| 225 | Material and labour for 4 core 6 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole etc, complete all as specified and directed. Make : Havells, Polycab, RPG Asian |
| 226 | Material and labour for 3.5 core 35 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed.Make : Havells/ Polycab/ RPG Asian |
| 227 | Material and labour for 3 ½ core 50 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make:- Havells/ Polycab/ RPG Asian |
| 228 | Supply & fixing of Anti suicide safe clamp made of CRCA electro cable device with newsmart fan down rod with buzzer made up of MS size300mm (12\"\")long white colour, new MS clamp& complete accesories re-usable safehalo clamp with buzzer, nut-bolt, rubber & nylock nuts with washer, cut off wire switch, spring of extended length of 1524mm,cable tie etc) , re-usable type device , buzzer (can be refixed) installed between the top down rod and the ceiling hook fan clamp. MSME tested for performance test and opening at impact loadof 20/22 kg the fan should come down seperating from the top of the ceiling , etc complete including taking down old ceiling fan from its position, refixing the same in its original position after fixing with the anti suicide device, clampandrod andelectric connection with newtwin core twisted wire 1.50sqmmcomplete all as specified and directed.Make : safe Halo/Gold life of safe solution or equivalent as approved by GE. Note:- (i) Trial test for proper functioning of anti suicide rod shall be carried out infront of User Rep and Engr-in-Charge.(ii) Test result certificateshall be produced by the contractor.(iii) The unit rate quoted to be inclusive for the provn of 1.5 sqmmnew cable/wire for electric connectionall as per site requirement and directed . |
| 229 | Material and labourfor shifting of Air Conditioner, Split type capacity of 1/ 2 TR from existing location to new location as per user requirement and installing, toping up of gas, replacement of copper tubing connecting up, commissioning and testing complete all as specified and as directed.Note :- The rate for following works deemed to be included in quoted rate :-(a)Transportation of air conditioner any type any capacity from one to other location. (b) Fixing only base plate with necessary fixing material on stone / brick walls and as directed (c) Fixing only outdoor and indoor units as required and directed (d) Connecting indoor / outdoors units of split ACs with copper tubes, flairs nuts, warping suction and discharge lines with inclucating materials with necessary fixing arrangements such as bolts, nuts washers and clamps etc. on walls (e) fixing PVC pipes 50mm dia for outlet of outdoor units to drain out dew water with necessary clamps. (f) Fixing of wall mounting voltage stabilizer of 3 KVA to 5 KVA capacity on the wall with necessary fixing arrangements such as bolts, nuts washers and clamps etc on wall. (g) Fixing PVC hose/ PVC pipes of 15mm sizes as reqd at site with necessary junction boxes, PVC bends etc. including two length of PVC copper cables of 4 sqmm size for electrical connection of ACs. (h) No additional payment shall be made for leakage of gas occurring during shifting of Air Conditioner and topping up of required gas.(j)Fixing of existing copper tubing of qty of required size. |
| 230 | Supply and fixing ofCopper tubing of size 1/4\" flare size conforming to relevant IS complete all as specified and directed. |
| 231 | Supply and fixing of Copper tubing of size 5/8\" flare size conforming to relevant IS complete all as specified and directed. |
| 232 | Supply and fixing offlexible PVC pipe of suitable size for indoor unit drain water of split AC suitable for any type and any capacity complete all as specified and directed. |
| 233 | Supply and fix MS wall bracketsuitable for fixing of out door unit of split type Air Conditioner with necessary nuts, bolts & washers and removing old unserviceable items and making good disturbed surfaces to match with the existing complete all as specified and directed. |
| 234 | Supply and fix polyurethane form insulation indoor to outdoor unit suitable for 1.5 Ton to 2 Ton split type A/C any type complete all as specified and directed. |
| 235 | Material and labourfor makingSQURE circular opening by cutting wall45cmx45cm thickness 38cmcomplete with inserting hume pipe collar of internal dia 300mm of lengthand length 38 cm and filling all around (between wall and outer dia of hume pipe collar) with PCC (1:2:4) B0 12.5mm graded crushed stone aggregate and grouting 04 Nos bolts of size not less than 10mm dia and 100mm long with nut & washer and making good to disturbed surface, complete all as specified and directed. |
| 236 | Supply, installation, testing & commissioning air cooled, split unit (indoor and outdoor) air conditioner electric driven AC 230 V, 50 Hz single phase of capacity 1.5 TR, BEE 3 Star rated with cooling and intelligent heating facility and Digital Inverter twin rotary including its fixing accessories with following specification :-(a) Rated cooling capacity - 18000 Btu/Hr.(b) Rated current cooling - 7.8 Amp.(c) Rated heating capacity - 18000 Btu/Hr.(d) Compressor type - Highr EER twin Rotary.(e) Anti dust/anti-bacterial Filter.(f)Dehumidifier.(g) Refrigerant gas - R32.(h) Operation : LCD Remote with self dignosis facility all as specified and directed.Make : Voltas/ Blue Star/ HitachiNote :- The quoted rate shall deemed to be include for powder coated stand (Bracket) for fixing outdoor unit and cutting, chasing of wall/ surface and making good as per existing. |
| 237 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA all as specified and as directed. Make :V-guard/Microtech/AE |
| 238 | S&F of factory madepowder coated distribution board TPN, 4 way double doorMCBDB includingbus bar, Neutral bar, standard DIN rail, earth bar complete all as directed.Make : Indoasian/ Havells/ Legrand. |
| 239 | S & F of TPN, MCB 63 Amp, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacitycomplete conforming to IS 8828 , all as specified Make : Legrand/ L&T/ Indo Asian |
| 240 | S&F ofSingle pole and neutral enclosure with a two pin and earth plug and socket complete with single poleMCB 25 Amps . Make: L&T/Legrand/Indoasian |
| 241 | M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 Sqmm drawn through in and incl suitable sizeERWrigid metallic Conduit and all accessories fixed to wall/floors along with 4 Sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and directed.Note: (a)2 runs of 4 Sqmm cable along with one run of 4 Sqmm cable for earth conductor and ERW rigid metallic conduit shall be measured as one lengthMake: Havells/ Polycab/ Plaza. |
| 242 | S&F flame proof junction box with spigotted cover in LM-6, three way/terminal block 4 way strip type cable entry, 20 mm dia hole aluminium constructed, internal dimension 80 mm dia and 40 mm depth, complete all as specified and directed. Make: Shyaam Switchgears Product Cat No SSPL/JB/105 or equivalent in Baliga / Flexpro |
| 243 | S&F flame proof rotary switch in LM-6, 10/16 Amps with termination box, single pole, 250 volts and enclosed cast aluminium body with threaded cover with switch operated by a sigle pole knob with double entries suitable for 20 mm dia ERW threaded steel conduit as per manufacturers intructions complete all as specified and directed.Make: Shyaam Switchgear/ Baliga / Flexpro |
| 244 | Supply and fixingflame proof, heavy duty metallic Exhaust fan of 300 mm, single phase, 230 V, 50 Hz with all accessories,prewired includingnecessary electric connection, louvers and making of holes of suitable sizes in wall of any description and finishing surfaces complete all as specified and as directed. Make : Sudhir/Baliga/Shyam Switchgear |
| 245 | Supply and Fixing of 4 feet surface mounted batten type luminaire , lumen output of 2000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability. The luminaire and driver shall be BIS approved, complete all as specified and directed. Make : Philips/ Bajaj / CG/Havells. |
| 246 | S&F of flame proof cast iron enclosure distribution board 415 volts, 6 way, SPN and MCB suitable for explosive atmosphere with explosive including necessary panel board for required connection from busbar to different outgoingand including making good to the disturbed surfaces of walls, floors etc, complete with following incoming and outgoing controls all as specified and directed:- (i)Incoming:- MCB, 2 Pole 32 Amp -01 Nos.(ii) Outgoing:- MCB Single Pole 6-32 Amp - 04 Nos. with complete internal bus bar & wiring up to terminals Make:- Shyaam Switch Gear Product Cat No SSPL/MCDB/186 or equivalent in Baliga / Flexpro |
| 247 | Supply and fixing of aluminium strip 25x3mm fixed with epoxy based insulator for down conductor air terminal network including drilling two Nos holes at each joint, one set of lead washers between strips, two sets GI nut andbolt, gutties, screws etc,.on wall /roof including necessary fixing arrangement up to height 20mtrcomplete all as specified and directed.Note:- (i) All safety measures shall be the responsibility of the contractor |
| 248 | Supply and fixingtest point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal. head screw, complete all as specified and directed. |
| 249 | S & FAir termination, single pointed, copper rod 12mm dia and 300mm long with mounting base with fixing arrangements and mounting nut, bolt and washers complete all as specified and directed |
| 250 | Supply, installation, testing & commissioning of maintenance free chemicalearthing system comprising of 17mm dia copper bondedrod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducingliquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installationcomplete all as specified and directed..Make : Model HTSP 317 of safeTrode or equivalent in Snaga/ Cubes 6 Global |
| 251 | The quoted rate shall also deemed to be included the following :- (i)Prior toinstallation of maintenance free chemicalearthing, soil resistivity test to be carried out at the location where earthingwork to be donein presence of Engr-in- Charge/JE (E/M),user and the report has tosubmitto Garrison Engineer with recommendation of manufacturer, if required additional interconnection ofearthing (not more than 08 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testingandsubmission of report with recommendationdeemed to be included in the quoted rate. |
| 252 | (ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors. |
| 253 | (iii) Rateofearth energizer compound of 25 Kg of 02 bags and earthresistance reducingliquid 10 litre per cane for each pit deemed to be included in the quoted rate. |
| 254 | (iv)Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor along with the sample approval |
| 255 | (v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete. |
| 256 | (vi) Copper strip of size 20 x 3 mm shallbe fixed on proper post insulator at the instrument end (copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately). |
| 257 | (vii)Testing of earth shall be carriedout in presence ofdepartmental and user representativeand report shall be submitted to Garrison Engineer duly signed by all concerned. |
| 258 | (viii)Earth resistance tester will be provided by the contractor.Tester should be calibrated from authorised company/ lab. |
| 259 | (ix)Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned.After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained. |
| 260 | (x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion. |
| 261 | (xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock. |
| 262 | (xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained. |
| 263 | (xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period. |
| 264 | (xiv) The electrode shallcarry manufacturer\"s name . |
| 265 | (xv) The connection clamp shall be permanentlly welded to the copper boundedrodto avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination. |
| 266 | (xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm. |
| 267 | (xvii)Earth work such as auguring andmaking good the surrounding area shall carried out in any type of soil. |
| 268 | (xviii)The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material. |
| 269 | (xix) Sign boardof mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxideZinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge. |
| 270 | Material and labour for Earth pit cover madeof heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mmfor each electrode pit completepit cover all as specified and directed. Make : Model SEPC 250 of SAFE TRODE/ Electrogrip Model/ EGTEK3LC of ISG Global or equivalent in Snaga.Note :- The contractor shall submit load bearing capacity certificate from the manufacturer. |
| 271 | M&L Copper strip 20 x 3.00mm thick as earthing lead fixed to wall/roofs etccomplete all as specified anddirected. Note : - All Joints should be joined by Exothermic Welding or Brazing. |
| 272 | Note :- An amount of Rs 50,998.00 on account of credit schedule for schedule \"A\" part II shall be deducted from the total amount of BOQ to arrive at the contract sum. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail