| 1 | [10.100.2]Cement Concrete 1:8:16 Flooring 2. Cement Concrete 1:8:16 with stone aggregate 40 mm size in foundation and plinth. [Through Rate] |
| 2 | [10.30.4]Providing and laying of chequered precast cement concrete tiles 22 mm thick in footpath and courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). 4. Ordinary cement without any pigment [Through Rate] |
| 3 | [13.41]Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). [Through Rate] |
| 4 | [34.26]Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface Providing and laying of hot applied thermoplastic compound 2.5 mm thick including Reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes. [Through Rate] |
| 5 | [4.14.1]Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1. All kinds of soil. [Through Rate] |
| 6 | [6.1.1]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1. 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) [Through Rate] |
| 7 | [6.14.1]Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) [Through Rate] |
| 8 | [6.33.3]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 3. Cold twisted bars [Through Rate] |
| 9 | [6.39.1]Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. 1. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). [Through Rate] |
| 10 | P/F mefium grade MS Junction boxes in cast in situ fundation beam of 150x150 mm size |
| 11 | Providing and pasting at site high grade printed vinyl with bus shelter name logo, route number etc. on one sides of the front facia information board. The vinyl shall be minimum 85 micron thick, of LG or equivalent make complete in all respect and to the entire satisfaction of engineer-in-charge. |
| 12 | Supplying and fixing single sided aluminum frame signage made of 6063-T5 aluminum frame with section weight 3.80 to 4.00kg/m with minimum tensile strength 22000 psl as per drawing provided having 4mm clear solid compact polycarbonate in front and 3mm ACP sheet reinforced with internal support frame at rear completely sealed with the of silicon and EPDM to make it dust and water proof should have the inbuilt strong clipping and frame arrangement for holding the flex or digital imedia alongwith all necessary cleats and corner joinery required to build thus signage with sufficient strength. The aluminum frame should have strong locking arrangement which can resist theft. The aluminum frame should have polyester powder coating with minimum thickness of 60 micron. Signage should have inbullt arrangement of mounting it with the bus shelter structure. The enclosure should provide weather proof protection required for the signage to operate outdoors, having inbuilt ventilation systems. |
| 13 | Supplying and fixing of double sided aluminum frame signage made of 6063-T5 aluminum frame with section weight 5.3 to 5.5kg/m with minimum tensile strength 22000 psl as per drawing provided having 4mm clear solid compact polycarbonate on both side and reinforced with internal support frame, completely sealed with the help of silicon and EPDM to make it dust and water proof. Should have the inbuilt strong clipping and frame arrangement for holding the flex of digital media alongwith all necessary cleats and corner joinery required to build the signage with sufficient strength. The aluminum frame should have strong locking arrangement which can resist theft. The aluminum frame should have polyester powder coating with minimum thickness of 60 micron, signage should have inbuilt arrangement of mounting it with the bus shelter structure. The enclosure should provide weather proof protection required for the signage to operate outdoors, having inbuilt ventilation systems. (measurements for double sided signage to be taken for both sides during |
| 14 | Vandal resistant light source of polycarbonate body with compact fluorescent lamp of white NS colour of 55w of approved make with IP 67 approval, including cable fixing, switchgear etc. all complete. |
| 15 | Providing and fixing MS Electrical weather proof leader box approximately 600mm wide and 900mm high as required for installing MCB switch gear and meters as required for advertisement and other electrical gear, with provision for inserting cable conduits as per design. The access to feeder box shall be through a toll based (common for all locks. provided in each package) key. Tools should not be identical for different package shelters |
| 16 | Providing and fixing anodized aluminum 25 x 50mm channel frame with 40W standard manufactured tube light fittings with electronic choke starters and wiring all complete connection to electrical supply drom feeder box with minimum 4 tubelights x per square meter (of add panel size) or actual requirement decided by the engineer in charge. The tube light frame and fittings (including that in feeder pillar) should includeballast ELCB timer MCB mounting blocks etc. The tube light alignment should allow two way lighting (front and back) of add panel |
| 17 | Providing and fixing heavy duty SS prefabricated dust bins with canopy and two point support grouted in cement mortar and finished as per floor finish. |
| 18 | Providing and fixing 5-walled, 10mm thick polycarbonate multiwall sheet bronze colour having a light transmission of 37% with a U- value of 2.39 w/m2 K.Lexan thermoclear multiwall sheet LT2UV105R175 from SABIC innovative plastics or Equivalent. Fixing of the 10mm sheet to be done with profiles having EPDM / silicon. Aluminum profiles need to be used and front and rear of polycarbonate sheet has to be closed by aluminum profile. Please Enable Macros to View BoQ information |