| 1 | M&L for Hardcore of broken stone of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface all as specified and directed by Engineer-in-charge |
| 2 | M&L for Anti termite treatment by Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface |
| 3 | M&L for Cement concrete 100mm thick type C-2, 1:3:6 (40mm graded aggregate) as in subbase to flooring complete. |
| 4 | M&L for Cement concrete type A-1, M-20, 1:1.5:3 (using 20mm graded aggregate) as in flooring finished plain to receive Acrylic flooring complete all as specified and directed. |
| 5 | M&L for 5 layer Acrylic flooring system suitable for outdoor volley ball court comprising of 1 Layer primer, 2 layers of cushion, 2 layers of Resurfacers of designated colour including for levelling and line marking all as specified. Make: Durocryl or other as approved with similar or superior specifications. |
| 6 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out in soft / loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, |
| 7 | M&L for rolled mild steel Joist, channel, angle, tubular or tee sections in Fe-410-W (Gde-E-250) quality-B, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) including for making arrangements for tieng of Volley ball net all as required. |
| 8 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in Soft / loose soil |
| 9 | M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering |
| 10 | Supply and spreading of good quality agricultural soil free from stones, rubbish like lumps, roots, and other foreign materials to a uniform thickness of 15 cm including watering, spreading mixed with organic manure in the ratio 4:1 and levelling complete all as specified and directed. |
| 11 | Supply and laying of lawn with Bermuda grass carpet having adequate developed roots, after providing anti-termite treatment to the filled soil including watering and shaping etc complete all as specified and directed. |
| 12 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out hard/dense soil all specified and directed. |
| 13 | M&L forReturning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm all as specified. |
| 14 | Removing excavated material to a distance exc 250 m but n exc 500 m and depositing where directed outside MOD land. Note: It is responsibility of the contractor to get permission from Local Authorities for site of disposal of material. |
| 15 | M&L forCement concrete in foundations, filling and mass concrete type D2 (1:4:8) in foundations of bed of drains, filling and mass concreteall specified and directed. |
| 16 | M&L for Pre-cast cement concrete block masonry type C-1, 1:3:6 (20mm graded aggregate) set in cement mortar 1:4 with solid blocks, exc. 10 cm in width and setting in mortar, complete |
| 17 | M&L for Pre-cast cement concrete block masonry type C-1, 1:3:6 (20mm graded aggregate) set in cement mortar 1:4 with solid blocks, exc. 10 cm in width and setting in mortar, complete including demolition ofBrickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles |
| 18 | M&L for Providing, cement concrete type B-1, 1:2:4 (20mm graded aggregate) in copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed |
| 19 | M&L for Rendering 10mm thick in Cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth (without using extra lime or cement) |
| 20 | M&L for corase sand filling suitable for filling around pipes under floors or foundations including watering and consolidation, spread and levelled in layers n exc 25cm thick all as specified and directed. |
| 21 | M&L for 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors provided with slots for percolation of water and conveyance |
| 22 | S&F for 110mm dai PVC (SWR) bends |
| 23 | M&L for Providing factory made perforated precast cement concrete type B1 1:2:4 (20mm graded aggregate) set in cement mortar 1:4 in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces suitably provided with holes for catching surface runoff water. |
| 24 | M&L for TMT bars Fe 500 10mm dia and over cut to length bent to shape required including cranking hooking ends and binding with and including MS wire annealed not less than 0.9mm dia complete all as specified and directed. |
| 25 | S&F for 2000ltr capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part |
| 26 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out in soft / loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, |
| 27 | M&L for rolled mild steel sections Fe-410-W (Gde-E-250) quality-B as in framing for cladding, glazing, staging for water tanks and the like fixed with angle cleats and connecting plates, etc. |
| 28 | M&L for rolled mild steel Plates (plain or chequered) Fe-410-W (Gde-E-250) quality-B channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment |
| 29 | M&L for preparation of new Surfaces of any description, over 10cm in width or girth,not otherwise described and applying one coat of Zinc chrome red oxide primer and two coats of synthetic enamel paint all as specified. |
| 30 | S&F 15 mm dia bore medium grade galvanized steel tubing with all fittings flaid in trenches all as specified and directed. |
| 31 | S&F 20mm dia bore medium grade galvanised steel tubing with all fittings laid in trenches all as specified and directed. |
| 32 | S&F 40mm dia bore medium grade galvanised steel tubing with all fittings laid in trenches all as specified and directed including taking connection from the tapping point. |
| 33 | S&F 20mm for Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed |
| 34 | S&F 20mm for Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed |
| 35 | S&F 15mm Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed |
| 36 | M&L for Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete |
| 37 | M&L for Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20kg/ 10sqm) applied over 3mm external wall care putty including complete removal of existing treatment all as specified. |
| 38 | Supply and fix Prestressed concrete poles of 9 meter long having 102 mm x 172 mm at top and 102 mm x 279 mm at bottom, class 10, etc complete all as specified and directed. |
| 39 | Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including necessary fitting arrengment complete all as specified and directed. |
| 40 | Supply and fix FRPlooping box of size 230x170x105mm with three phase connector andcomprising of MCB SP 10 Amps, ISI marked,240V complete with and including providingGI clamps,nuts boltsetc suitable for fixing on PCC pole/ wall etccomplete all as specified and directed. Make:- National/Sintex |
| 41 | Supply and fixGI bracket pipe of size 32 mm dia medium grade of 1.2 mtr long bent to shape hot or cold suitable for street light fitting and making the one end of GI pipe bracket suitable for fixing of any type street light fitting and shall be fixed on wall surfaces. The bracket pipe shall be welded to the MS stripof size 32mmX 5mm thick at three placesfor purpose of giving strengthening to the bracket pipe and fixing with necessary suitablenuts,bolts & washers complete all as specified and directed.Make of GI pipe:- Jindal/Tata/BST |
| 42 | Supply and fix rigid non-metallic PVC conduit 25 mm dia medium grade including conduit accessories for encasing the cable from looping box to street light fittings on PCC poles/on wall surfaces as per site requirement with neccessary base saddles all as specified and directed. Make:-Finolex/Prince/Supreme/Precision/Dutron/Tirupati |
| 43 | Supplyand fix copper conductor cable, PVC insulated, sheathed,flexible, multistranded,ISI marked, 1100 volts grade, 3 core ;2.5 sqmm and including connectionand testing complete all as specified and directed. Make:-Havell/Finolex/Plaza/Polycab |
| 44 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core |
| 45 | Supply and fix in repair, factory made, TPN DB\"s,04 way 415 volts, AC,TPN, vertical distribution board, double door, painted with epoxy based powder coated suitable for mountingMCBFP, 16-36 KA and MCB SP /TP as outgoings and complete withand including 200 amps rated copper busbar, neutral bar,earth bar, connecting cable links with and including top and bottom removable gland plate, complete withIP 43 protection,all as specified and as directed. |
| 46 | Supply and fix in repairs MCB distribution board SPN 8 way 240 volts, double door withIP 42 protection duly painted with epoxy based powder coated painting suitable for mounting MCB DP/SPN as incomer and MCB SP/DP as outgoings complete with 200 Amps rated busbar, neutral bar, earth bar connecting cable links with top and bottom removable gland plate including removing old unserviceable item complete all as specified and as directed. |
| 47 | Supply and fix in repairs for MCB FP 63 Amp 10 KA \"c\" series complete all as specified and directed. |
| 48 | Supply & fixMCB SPN 40 Amps, 240 V, 50 Hz,10 KA,\"C\" seriescomplete all as specified and as directed. |
| 49 | Supply & fix for MCB SP 6-32 Amps 10 KA,\"C\" seriescomplete all as specified and directed. |
| 50 | M&L for point wiring complete using proper colour code 1.5 sqmm, PVC insulated, FRLSH type, single core, unsheathed, multistranded copper conductor cable, ISI marked, 1100 volts grade conforming to IS 694, Part-II with latest amendments up to date drawn through and including PVC conduit medium grade not less than 25 mm dia with all conduit accessories concealed in wall/ceiling/beams/column etc. and providing GI metal boxes 1.6 mm thick with flush mounting and modular cover plate with modular frame suitable for mounting modular switches, sockets, regulators etc. and fixing with necessary screws, washers including 1.5 Sqmm PVC insulated FRLSH type, single core, unsheathed, multistranded copper conductor cable, ISI marked, 1100 volts grade green in colour as continuous earth wire connected to common earth dolly complete all as specified and directed for following:- |
| 51 | (a) One light point / fan point controlled by one switch. |
| 52 | (b) One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board . |
| 53 | All as per item No.8 above, but point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm complete all as specified and directed for One 6 pin 16/6 amps socket outlet point controlled by one 16 amps switchon independent board. |
| 54 | Supply & fixing modular type switch 6 Amps ,1way,1 module. |
| 55 | Supply & fixing modular type switch 16 Amps ,1way,1 module . |
| 56 | Supply & fixing modular type socket 6 Amps, 2/3 Pin combined 2 module . |
| 57 | Supply & fixing modular type socket 16 Amps, 6 Pin combined 2 module. |
| 58 | Supply & fix ceiling rose, 3 terminal ,PVC/polycarbonate body |
| 59 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 60 | Supply and fixing LED lights fitting 1x 22W, 220V, 4\" long AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 61 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete with all accessories and necessaryfixing arrangementon wall at any height includingthree core 0.5 sqmm copper cable from connector to fitting and removing old unserviceable item complete all as specified and directed. |
| 62 | Excavation in trenches , not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in any type of soil complete all asspecified and directed. |
| 63 | Excavation in trenches , not exceeding 1.5 mtr wide and not exc 3 mtr depth for poles/stay etc and getting out in any type of soil complete all asspecified and directed. |
| 64 | Returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed |
| 65 | Removing excavated soil not exc50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed |
| 66 | Supply and lay new high density polyethylene DWC pipes of 63mm OD/ 50mm ID, 6 kgf/sqcm including all fittings (bends, Tees, Elbows, sockets, etc) as required on site, complete all as specified and directed.Note:Excavation, return filling and removal of any type of soil/ strata shall be measured and paid separatelyunder respective items of BOQ. |
| 67 | M&L Plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregates) as in foundation of pole etc all as specified and directed. |
| 68 | M&L Plain cement concrete 1:2:4 type C-2 (using 20 mm graded crushed stone aggregates) as in coping of pole including necessary form work etc complete all as specified and directed. |
| 69 | M&L Plain cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregates) as in foundation filling and mass concreteetc complete all as specified and directed. |
| 70 | Earthing complete with galvanisedsteel earth plate electrode60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |