| 1 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 min depth for laying of CI / GI pipes laying in trenches and getting out in soft/loose soil, complete all as specified and directed by Engr-in-Charge. |
| 2 | Returning, filling in trenches including , leveling watering and well ramming in layers not exc 25 cm in soft / loose soil, complete all as specified and directed by Engr-in-Charge. |
| 3 | Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at level not exc 1.5 mtr above the starting point, complete all as specified and directed by Engr-in-Charge. |
| 4 | Material & Labour for Galvanised Iron Pipe 20mm dia medium grade galvanised with all fittings and fixed complete laid as in trenches / floor including taking down of existing pipes, complete all as specified and directed by Engr-in-Charge. |
| 5 | All as per ser item No. 4.00here in before but 25mm dia pipe, complete all as specified and directed by Engr-in-Charge. |
| 6 | All as per ser item No. 4.00here in before but 40mm dia pipe, complete all as specified and directed by Engr-in-Charge. |
| 7 | All as per ser item No. 4.00here in before but 50mm dia pipe, complete all as specified and directed by Engr-in-Charge. |
| 8 | All as per ser item No. 4.00here in before but 80mm dia pipe, complete all as specified and directed by Engr-in-Charge. |
| 9 | Supply & fixing centrifugally 100mm cast (spun) ductile ironpressurepipes with socket & spigot ends having ISI stamping marking with IS 8329/2000 classification K7, In standardlength of 5.5 - 6 mtr suitable for andincluding push on joint (gassket D jointing) with cement mortar liningin the pipes including taking out GI/DI pipe, complete all as specified anddirected. |
| 10 | All as per ser item No. 9.00here in before but 150mm dia pipe, complete all as specified and directed by Engr-in-Charge. |
| 11 | Supply & fixing in repairs DI fittings for flanged & spigot socketed pipe e.g. bends (any type, radius and angle), tapers any type, (straight, bend, increasing, decreasing or double socket etc) tee pieces, collars, caps and plugs conforming to IS of size upto 200/150/100 mm bore, complete all as specified and directed. |
| 12 | Supply and fix in repairs Gun Metal gate valve with Iron wheel head screwed both ends for GI steel tubing 20mm dia, complete all as specified and directed by Engr-in-Charge. |
| 13 | All as per ser item No. 12.00 here in before but 25mm dia, complete all as specified and directed by Engr-in-Charge. |
| 14 | All as per ser item No. 12.00 here in before but 40mm dia, complete all as specified and directed by Engr-in-Charge. |
| 15 | All as per ser item No. 12.00 here in before but 50mm dia, complete all as specified and directed by Engr-in-Charge. |
| 16 | Supply & fix cast iron sluice valve 100mm dia, flanged ends, stem (spindle) of SS (forged)and check nut of gun metal, PN rating 1.6, working parts conforming to IS :14846, and flanged ends having drilling as per IS:1538 including taking down old unserviceable sluice valve, complete all as specified and directed by Engr-in-Charge. |
| 17 | Painting ofCI/DI/GI pipes of size 100/150/200 mm, MS pit cover with two coats of synthetic enamel paint after scratching the existing paint properly and cleaning the surface properly. complete all as specified and directed by Engineer-in-charge. |
| 18 | Supply and fix in replacement of unserviceable Pressure gauge 100mm dia with ball valve of pressure 0-21 Kg/Sqcm with matching thread of specification, complete all as specified and directed by Engineer-in-charge. |
| 19 | M&L in repairs for fixing & jointing cast iron non return (reflux)/ valve ISI marked, flanged ends, class PN 1.6 with flanged and drilled ends suitable for 100mm nominal bore pipecomplete with all acessories & including joints and jointing material such as bolts, nuts, washers and rubber gaskets, complete all as specified and directed by Engineer-in-charge. |
| 20 | M&L in repairs for fixing & jointing Cast Iron Air release valve ISI marked, flanged ends, class PN 1.6 with flanged and drilled ends suitable for upto 200mm nominal bore pipecomplete with all acessories & including joints and jointing material such as bolts, nuts, washers and rubber gaskets, complete all as specified and directed by Engineer-in-charge. |
| 21 | Dismantling and taking up submersible pumps set of any capacity and any size from bore well with the help of chain pulley block including dismaintling the MS/GI column pipe up to 115 mtr and electrical mechanical connection transportation from site to authorised workshop at Ambala /Chandigarh for carrying out necessary repairs /replacement of defective / worn out parts and back to site, lowering the submercible pump set in to borewell after testing including connecting coulmn pipe and cable connection etc, after completion of the work testing of pump set on load to the entire satisfaction of Engr-in-Charge and reading the data complete. Note :- (i) T&P required for raising & lowering, the pumps and pipes will be arranged by contractorand the cost deemed to be included in the unit rate quoted by the contrator for this items.(ii) Small items such as nuts, bolts washers and rubber gasket required will be included in the item rate.(iii) Spare parts for repair will be measured and paid separately. |
| 22 | Strip opening of pump set complete of capacity 30/40 HP Make KSB and removing scales, cleaning serviceable parts and re-assembling after carrying out repairs / replacement of worn out parts including seals, \"o\"rings, washers, nuts and bolts as required and making the pump set fully serviceable and testing to the entire satisfaction of Engr-in-charge complete all as specified and directed. Note :- (i) Spares for replacement will be measured & paid separately under respective items herein after supply only.(ii) Replacement of all other items such as seals, \"o\"ring , washers, nuts and bolts will be deemed to be included in rate quoted against this item. |
| 23 | Supply only of the following new items suitable for pump set of capacity 40/41 HP in lieu of unserviceable parts. |
| 24 | Impeller of existing specification. |
| 25 | Stage sleeve of existing specification and make. |
| 26 | Stage bush of existing specification and make. |
| 27 | Gasket of existing specification and make. |
| 28 | Bushing sleeve of existing specification and make. |
| 29 | Bearing Bush of existing specification and make. |
| 30 | Pump shaft of existing specification and make. |
| 31 | Pump key of existing specification and make. |
| 32 | Space sleeve of existing specification and make. |
| 33 | Suction stainer of existing specification and make. |
| 34 | Shaft sleeve for motor of existing specification and make. |
| 35 | Cable packing pipe of existing specification and make. |
| 36 | Cable gland ring of existing specification and make. |
| 37 | Bearing Bush for motor of existing specification and make. |
| 38 | Bearing sleeve for motor of existing specification and make. |
| 39 | Bowl assembly complete with accessories of existing specification and make. |
| 40 | Sleeve coupling of existing specification and make. |
| 41 | Material and labour strip for opening of submersible motor for 30/40 HP pumping set and taking out burnt copper conductor and cleaning of stator and rotor surfaces and carrying out new re-winding with existing size, and weight gauge / suitable size and weight of copper conductor and providing newinsulating material of \"F\" class insulation, heating varnishing, drying through electric furnance and testing on specified load, complete all as specified & directed by Engr-in-Charge. |
| 42 | Supply, lowering, jointing, testing and commissioning GI pipe heavy duty 100mm internal dia (3 mtr long with both ends threaded and fitted with heavy duty MS flanges 14mm thick, two Nos groves for submersible cable continuous welded and drilled 4 Nos hole, completeas column pipeincluding jointing material such as bolts, nuts, washers and rubber gasket etc, complete all as specified & directed by Engr-in-Charge. |
| 43 | Material and labour for attending complaint as and when required , taking out old unserviceable GI pipe of 20 mm dia pipe cutting at location/ site to remove rusted/ damaged pipe including S&F for connecting new pipe in replacement of length 0.5 RM with the existing pipe line, including testing of pipe line so repaired for complete satisfaction of Engr-in- Charge.Note:- (i) Excavation, removal & returning filling of soil (soft/hard) is deemed to be inclusive in the quoted rate.(ii) Cost of GI fittings like socket, union, tees, long screw, nipple, hexa nipple, reducer etc is deemed to be included in the quoted rate.(iii)Length of pipes required to be replaced if is more than 0.5 RM the same will be measured in the relevant items of this schedule. |
| 44 | All as per ser item No. 26.00here in before but GI pipe line of25mm dia, complete all as specified and directed by Engr-in-Charge. |
| 45 | All as per ser item No. 26.00here in before but GI pipe line of40/50mm dia, complete all as specified and directed by Engr-in-Charge. |
| 46 | All as per ser item No. 26.00here in before but GI pipe line of80mm dia, complete all as specified and directed by Engr-in-Charge. |
| 47 | Cutting DI/CI pipes and reducingto required length in position for inserting of new tees branches, collors, bends etc for 100/150/200 mm dia pipes, complete all as specified and directed by Engr-in-Charge. Note:- Both sides cutting shall be measured as one unit. |
| 48 | Material and labourconstruction of brick masonary valve pit of size 1200 mm x 1200mm x 1200 mm (Internal size) thickness of walls shall be 23cm in brick work in cm 1:6 internally plastered in cm (1:6) and externally plastered in cm (1:4) over 15cm thick PCC 1:4:8 type D-2 having 15m offset around, including 4 cm thick coping in PCC 1:2:4 type B-1 as the top of the brick wall and3mm thick mild steel sheet cover and angle iron frame of size 40mm x 40mm x 6mm including provn of suitable hold fasts to hold the frame, locking arrangement and lifting handle, duly painted with two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified and directed by Engr-in-Charge . |
| 49 | Material and labourconstruction of brick masonary valve pit of size 900mm x 900mm x 900mm (Internal size) thickness of walls shall be 23cm in brick work in cm 1:6 internally plastered in cm (1:6) and externally plastered in cm (1:4) over 15cm thick PCC 1:4:8 type D-2 having 15m offset around, including 4 cm thick coping in PCC 1:2:4 type B-1 as the top of the brick wall and3mm thick mild steel sheet cover and angle iron frame of size 40mm x 40mm x 6mm including provn of suitable hold fasts to hold the frame, locking arrangement and lifting handle, duly painted with two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified and directed by Engr-in-Charge. |
| 50 | Supply and fix D-Joint of upto 100 mm dia in CI/DI pipe line to stop leakage with all necessary items which is required for to stop leakage including necessary excavation and refilling, complete all as specified and directed by Engr-in-Charge. |
| 51 | Demolition of stoneorbrick masonry built in cement mortar including all quoins, arches etc. but excluding ashlar facing, dressed stone work etc, complete all as specified and directed. |
| 52 | Material and labour for brick work with sub class \"B\" bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 completeall as specified and directed by Engr-in-Charge. |
| 53 | All as per ser item No. 35.00here in before but except brick complete all as specified and directed by Engr-in-Charge.Note:- Serviceble Old bricks obtain from ser item No 34.00 shall be reused after cleaning. |
| 54 | Material and labour 15mm thick cement plaster in cement mortar 1:4 on fair faces of brick walls or concrete external surfacesfinished even & fair without using extra cement, completeincluding white wash, complete all as specified and directed by Engr-in-Charge. |
| 55 | Demolition of reinforced cement concrete of any description in any position not otherwise specifically provided for (Reinforcement cut as required to facilitate demolition), complete all as specified and directed. |
| 56 | Material and labourfor PCC 1:2:4 type B1 using 20mm graded mechanically crushed stone aggregate as in coping and foundations for DG etc, complete all as specified and directed by Engr-in-Charge. |
| 57 | Supply and Fixvalve pit coverwith angle iron frame size 40mm x 40mm x 6mm , MS sheet cover 3.15mm thickness , MS sliding bollt and pad locking arrangementalongwith painting of pit cover etc including taking out old or damagedvalve pit cover, complete all as specified and directed by Engr-in-Charge. |
| 58 | Material and lobour replacement of worn out flat submersible PVC insulated 3 core copper conductor size of 25 Sqm 1100V grade, 50 Hz for submersible, complete all as specified and directed by Engr-in-Charge. |
| 59 | Dismantling and taking out submersible pumps set of10/ 20/30/ 40/41HP capacity and any size from bore well with the help of chain pulley block including dismantling the MS/GI column pipe, and change nuts bolts washers, good quailty ISI marked rubber gasket,lowering the submersible pump set in to borewell after testing including connecting coulmn pipes and cable connections etc, after completion of the work testing of pump set on load to the entire satisfaction of Engr-in-Charge and reading the data complete. For development of bore well, complete all as specified and directed by Engr-in-Charge.Note :- (i) T&P required for raising & lowering, the pumps and pipes will be arranged by contractorand the cost deemed to be included in the unit rate quoted by the contrator for there items.(ii) Small items such as nuts, bolts washers and rubber gasket required will be included in the unit rate for these items. |
| 60 | Development of tube well by air compressor of capacity not less than 500 CFM at 150 to 200 PSIG approximate capacity as required on ground till to get clear water complete including all T&P , Diesel and other materiel required at site and carrying out yield test, complete all as specified and directed by Engr-in-Charge. |
| 61 | Taking out water sample in containers and getting the water testedfrom the department of water test examination from govt approved NABL Lab aur NIIRT- Centre for Calibtation, analysis and Testing for chemical & Bacteriological test complete all as directed by Engr-in-Charge for following locations:-(a) PH No 8 (b) PH No GP 2 (c) PH No 2A (d) PH No 7(e) PH No 6 (f) PH No 9 Parameter (Test Periodicity:- Quaterly Once all in Five Pump House)a. (i) Colour, (ii) Turbidity, (iii) Residual Chlorine, (iv) Total Chlorineb. (i) PH, (ii) Chloride, (iii) Flouride, (iv) Iron, (v) Hardness, (vi) Total Plate Count ,(vii) Electrici Conductivity, (viii) Sulfate, (ix) Nitrate , (x) TDSc. (i) Colifrom, (ii) E coilNote :- (i) The Rate quoted by the contractor deemed to be inclusive ofthe cost of transportation, cost of sample bottles as prescribed by the lab, cost of collection of samples from all the locations and submission of report.(ii) The samples shall be collected during the distribution time, which shall be coordinated with the concerned JE.(iii) The entire report should be submitted in the prescribed format indicating standard permissible values and test results. (iv) Testing of samples (a) to (f) for allthe test will be measured as one job ) |
| 62 | Supply only of Calcium Hypochlorite(Calcium based granular disinfectant for water treatment, more stale than chlorine gas and stronger than bleaching powder and sodium hypo chlorite) packing in 45 Kgs plastic drums and All make approved by CMPT, complete all as specified and directed by Engr-in-Charge. |
| 63 | Supply only water testing kit for the estimation of residual chlorine, complete all as specified and directed by Engr-in-Charge. |
| 64 | Supply and fixing high quality chlorine pipe of 4-6 mm dia high pressure pipe for chlorine supply, complete all as specified and directed by Engr-in-Charge. |
| 65 | Supply and fix in repairs NRV valve of 15-20mm dia of chlorine dozing pump outgoing to main line, complete all as specified and directed by Engr-in-Charge. |
| 66 | Taking out existing , supply and fixing of Injector Dosing Pump: Adjustable High Pressure 0-7 Kg/cm2 power input 220 V, 50 Hz 40 SPM 1/30 fractional horse power, Max ouput 0-10 Ltr/hr. Pump with PP Head with mandatory accessories (Antisyphone Valve Assy,Foot Valve Assy, Tubing (LDPE) 3 Mtrs.) or as per site conditions including taking out existing injector dosing pump, complete all as specified and directed by Engr-in-Charge. |
| 67 | Supply and fixing of Service Dosing Tank Capacity 100 Ltr. (FRP dosing tank of 100 Ltr. Top dia 540 mm x Bottom dia 480 mm x Height 575 mm Consisting of water inlet line, Drain, Overflow Level gauge inspection port). including taking out existing dosing tank capacity 100 Ltr, complete all as specified and directed by Engr-in-Charge. |
| 68 | Supply and fixing of Service Dosing Tank Capacity 200 Ltr. (FRP dosing tank of 200 Ltr. Dia 750 mm, Height 495mm Consisting of Water inlet and outlet line, Drain, Overflow, Pot hole with cover)or as per site conditions. or as per site conditions including taking out existing dosing tank capacity 200 Ltr, complete all as specified and directed by Engr-in-Charge. |
| 69 | Supply and fixing of Agitator Motor - 200V, 120 Watt 900 RPM single phase, copper wound, flange mounted motor (With plastic shaft and impeller for make liquid solution).or as per site conditions including taking out existing Agitator Motor - 200V, complete all as specified and directed by Engr-in-Charge. |
| 70 | Material and labour for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for crossing of water pipe line GI/DI size upto 200mm dia, complete all as specified and directed by Engr-in-Charge. |
| 71 | Material and labourfor preparing old surfaces plastered andwhite wash 1st coat undecoratede surface and 2nd coat of old decorateed surface ofany size of valve chamber incl rubbing of internal surface by wire brush/scrubber,desilting of vale pitmanually cleaning the internal area with brush, removing loose/deposited dirt etc, cleaning with water thorough, complete all as specified and directed by Engr-in-Charge. |
| 72 | Supply and fix in replacement for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meter deep below normal ground level connected to galvanized earth strip of size 25 x 6 mm, 7.5m long means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR part I connecting to earthing test point and testing on completion with and including PCC pit in mix 1:3:6 type c1 with RCC 1:2:4 type B-1, 40mm thick cover reinforced with 6mm dia MS bars 3 Nos both ways with lifting book made out of 6mm dia bar, watering arrangement with funnel and wire mesh and 20mm bore light grade GI watering pipe, common salt and charcoal filling, necessary excavation and earth work, complete all as specified and directed by Engr-in-Charge. |
| 73 | Maintenance and servicing ofVFD Panel installed at siteincluding all connected items and carrying out routine \"A\" check of thewiring , setting etc complete for smooth functioning all as per manufacturer\"s instructions and as directed.NOTES :- (i) Control switches such as MCCB, Main switch, contactors, multi display meter and all enternal items shall be out of scope of the item of work and the rate quoted shall exclusive of servicing/ maintenance of the above said fittings.(ii) Spare parts required for replacement during the maintenance period shall be deemed to beincluded in quoted rate of this item. |