| 1 | Supply and errection of 6.00 meter long GI Octagonal pole of approved make (top dia 70mmm bottom dia 130mm and base plate 12mm thick) having 3mm thickness with single arm barcket 1mtr. length in 1:2:4 RCC foundation bolt including ther cost of foundation, excavation back filling etc. rates includes all materials, labour, T&P ketc required for proper completion of the work as per E/I SI 647/2018 |
| 2 | Supply and fixing of Column light made of mild steel with fine laser cut design closed by diffuser and have ingress protection for optical compartment. Fitting height 3mtr above ground level with mid light illumination of 40W. The column section shall be of 300mm x 300mm x 100 mm with top part predesigned with street light of 50W for illuminating the side areas. Mid-section gives the homogeneous light output. All pole section Shall be welded by certified welders using high MIG welding process. The Service door shall be provided at bottom part of the pole which equipped with a C clamp with sliding nuts to accommodate a built in connection box. The control gear tray is prewired with MCB, terminal connectors for loop in loop out arrangement. The base plate of the pole is design with elongated foundation holes for fine alignment of the pole during installation. Fitting is made of mild steel with fine laser cut design and signage closed by PMMA diffuser tailored with lighting to suit your specific needs as per detail drawing. Color tolerance ,3 SCDM to avoid color deviation. All exterior parts are made of stainless steel. Column light fixture is complete in all aspects with all accessories except foundation bolt. The work includes all miscellaneous parts and equipmets as required. The work will executed as per direction of E/I complete in all respect. (MR) |
| 3 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 110 to 130 Watt. Confirming to IP 66 Protection complete in all respect. E/I S.I 1424(2018) CAT-AAA (halonix,phillips,jaguar) |
| 4 | S/L of aluminum conductor PVC insulated armored served sheathed cable 1100 volts grade devider on top surface etc. comp. ((PWD SOR Item NO 501/ 2018)- 25 Sq.mm. x 3-1/2 core 501(J)/2018 |
| 5 | S/L of aluminum conductor PVC insulated armored served sheathed cable 1100 volts grade devider on top surface etc. comp. ((PWD SOR Item NO 501/ 2018)- 70 Sq.mm. x 3-1/2 core 501(i)/2018 |
| 6 | S/F of palm or pin type copper tin planted cable socket (lug) to the cable leads etc. comp. (504/2018)- 35 Sq.mm. 504(m)/2018 |
| 7 | S/F of palm or pin type copper tin planted cable socket (lug) to the cable leads etc. comp. (504/2018)- 70 Sq.mm. 504(h)/2018 |
| 8 | S & F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve S.I.no. 1002(CAT A)/2018 |
| 9 | S/E of Double walled corrugated HDPE pipe size 90/63 mm at a depth of 1.20 mtr. Below ground level complete excavation and back filling (Rate includes manual trunch less if required) complete work as per direction of E/I. |
| 10 | S/W of submain with two number 4 sq.mm. PVC insulated 1100 V grade single core copper conductor cable in 20 mm dia. heavy guage rigid steel conduit on surface, with one number 8 SWG GI earth continuity wire etc, complete in all respects {289(A) SOR-2018} |
| 11 | Road cutting and repair for laying of cable work through 63/90 mm HDP Pipe. |
| 12 | Supplying & Laying of 25mm x 3 mm G.I. Strip for earth Electrode 300.00 directly in the ground as required complete in all respects. P.W.D.S.O.R. 2018 S.I. No.716 |
| 13 | Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable enteies Electrical control panel with TPN MCCB\"s (Four pole 36 KA with thermal maganatic release) Switches complete and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA, P.F., KW etc.) in each phase with touch type selector switches for different reading, instrument fuses, current transfomer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB\"s shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2mm. Cubicle type switch board shall be of cat A & B only.Incoming100 Amp. MCCB-1 NoOutgoing(a) 63 Amp. MCCB-2 Nos.(ii) Cat. B. Pannel Cubicle Type each 811(PWD)SOR-2018 |
| 14 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. 807(PWD)SOR-2018(F)(ii) 40 A TPN |
| 15 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I. strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. complete work as per direction of E/I. 725(a)(PWD)SOR-2018 Please Enable Macros to View BoQ information |