| 1 | DESCRIPTION OF ITEMS |
| 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil as specified and as directed. |
| 3 | M&L PCC 1:4:8 type D-2 using (40 mm graded stone aggregate) as in foundation, sub base / mass concrete,etc complete all as specified and directed. |
| 4 | S & F for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed. |
| 5 | M & L for RCC M-25 (Design Mix) with 20 mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. |
| 6 | M&L brick work with sub class B brick straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 7 | M&L for 15 mm thick rendering in cement mortar (1:4) on fair faces ofbrick walls or concrete surfaces mixed with water proofing compound as per manufacturer instructions, finished fair andevenwithout using extra cement all complete as specified and as directed |
| 8 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 9 | M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed. |
| 10 | M&L for Mild steel bolts. purpose made. with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square n. exc 30cm long complete all as specified and directed. |
| 11 | S & F of Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed. |
| 12 | S & F for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe 410-W(Gde-E-250) quality-A complete all as specified and directed. |
| 13 | S & F for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed. |
| 14 | S & F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 15 | S & F for Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 16 | M & L preparation of new steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 17 | Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers n exc 25 cm thick in any type of soil all complete all as specified and directed. |
| 18 | M & L for Removing excavated material n exc. 100m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 19 | Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 20 | M & L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in roof kerbs, coping, benching etc including weathering slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 21 | M & L for providing and applying minimum 1mm thick wall care putty over prepared surface to achive the surface even and smooth for further application of finishes complete all as specified and directed. |
| 22 | Preparation ofplastered or unplastered surfaces on walls and applying two coats of 100% Premium arcylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance , dirt resistant exterior paint of required shade over and including priming coat of exterior primer applied complete all as specified and directed. |
| 23 | Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 24 | M & L for hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers not exc.15cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 25 | M & L for 75mm thick PCC 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed. |
| 26 | M & L for brickwork with old sized sub-class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM(1:4) complete all as specified and directed. |
| 27 | M & L for 10mm thick cement plaster in CM (1:6) on other than fair surfaces of brick walls and finishing the surfaces fair and even complete all as specified and directed. |
| 28 | M & L for 15mm thick cement plastering in CM (1:4) on fair surfaces of brick walls and finishing the surface fair and even complete all as specified and directed. |
| 29 | M & L for preparation of new wall surfaces and applying two coats of distemper oil emulsion over a layer of 1mm thick wall care putty complete all as specified and directed. |
| 30 | M & L for preparing new surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed. |
| 31 | M & L for RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 32 | M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), work in rough finished flat surfaces of concrete complete all as specified and as directed. |
| 33 | M & L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, work in rough finished surfaces of concrete complete all as specified and as directed. |
| 34 | M & L for 40mm thick damp proof course in cement concrete (1:2:4) type B-0 (using 12.5mm graded stone aggregate) to horizontal or vertical surfaces including necessary formwork and using water proofing compound as per manufacturer\"s instructions complete all as specified and directed Note :- WPC shall be measured and paid separately. |
| 35 | Supply only liquid water proofing compound. |
| 36 | S & F of 110mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to walls complete all as specified. |
| 37 | S & F of 110mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified. |
| 38 | S & F of 75mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified. |
| 39 | S & F of PVC (SWR) bends 110mm dia complete all as specified and directed. |
| 40 | S & F PVC (SWR) 110 mm junction (Single T) equal or unequal 110mm complete all as specified and directed. |
| 41 | S & F of PVC (SWR) bends 75mm dia complete all as specified and directed. |
| 42 | S & F PVC (SWR) vents cowl 110m dia complete all as specified and directed. |
| 43 | S & F PVC (SWR) 75mm floor trap, plain with gratting, including jointing with solvent cement complete all as specified and directed. |
| 44 | S & F of rolled mild steel sections as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Gde Fe-410 W (Gde- E- 250) quality-A complete all as specified and as directed. |
| 45 | S & F of rolled mild steel works as in bands, straps, supports or stays for rainwater, hook and pintle hinges, clamps, hold fasts, wall ties, hooks for hanging fans, gusset plates, plain angle cleats for securing purlins to wood trusses or rafters and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 46 | M & L for joint free non-skid ceramic coloured floor tiles exc 0.11sqm but not exc. 0.18sqm as in floors set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade over and including 15mm thick screed bed in CM(1:6) complete all as specified and directed. |
| 47 | M & L for glazed ceramic coloured wall tiles 450X300mm and 7mm thick including bedded and jointed in neat cement slurry and pointed with white cement with pigment to match the shade of tile over 10 mm thick rendering in CM(1:4) complete all as specified and directed. |
| 48 | S & F of vitreous china wash hand basin white flat back of size 550mm x 400mm including cutting for and pinning ends of brackets including 32mm bore PTMT waste coupling (half or full threaded) and PVC waste pipe 32mm dia and 15mm bore PVC connection 450mm long with brass union and jam nuts on both sides and fixed on a pair of MS cantilever bracket of appropriate size complete all as specified and directed. |
| 49 | S & F of 15mm bore fancy type pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed. |
| 50 | S & F of 600x450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed by Engineer-in- Charge. |
| 51 | S & F of towel rail 600mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms) complete all as specified and directed. |
| 52 | S & F of vitreous china squatting pan of Orissa pattern, size 580x440 mm size white with integral foot rest with Cast Iron `P\" or `S\" trap, front or back inlet andincluding connection to trap and to flushing pipe, anti-syphonage pipe etc., including trap set in and including cement concrete bedding including providing new flush pipe complete all as specified and directed. |
| 53 | S & F of vitreous china wash down water closet pan (EWC pedastal pattern) white,with Cast Iron `P\" or `S\" trap, front or back inlet andincluding connection to trap and to flushing pipe, anti-syphonage pipe etc., including trap set in and including cement concrete bedding and including mild steel chromium plated or aluminised hinging device seat cover (white) complete all as specified and directed. |
| 54 | S & F of health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect complete all as specified and directed. |
| 55 | S & F of PVC low level flushing cistern 10 Litres capacity with all internal accessories and fixed to wall including 450mm long PVC connection pipe 15mm bore with brass union and jam nuts on both sides, PVC flush pipe 32mm dia fixed properly to inlet of WC complete all as specified and directed. |
| 56 | S & F of 15mm bore bib taps fancy type, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe all as specified or as directed. |
| 57 | S & F of 15mm bore angular stop cock fancy type, cast copper alloy chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed for iron pipe or for unions and fixed complete all as specified and directed. |
| 58 | S & F of 15mm bore concealed stop cock fancy type, cast copper alloy chromium plated long shank and cup, screwed down, screwed for iron pipe of 15mm bore all as specified or as directed. |
| 59 | S & F of brass chromium plated shower rose of 125mm size with or without swivel joints including fixing to steel pipe or union all as specified and directed. |
| 60 | S & F GI tubing medium grade, galvanised with all fittings and fixed complete to wall and ceiling or laid in floors bore of tube 15mm all as specified and directed. |
| 61 | S & F GI tubing medium grade, galvanised with all fittings and fixed complete to wall and ceiling or laid in floors bore of tube 20mm all as specified and directed. |
| 62 | Supplying, hoisting and fixing of rotational moulded PVC water storage tank, 1000 litres capacity conforming to IS-12701 (1996) cylindrical vertical type triple-layered with closed top including 20mm bore PVC float valve and necessary fittings for inlet, outlet and wash out holes complete all as specified and as directed. |
| 63 | S & F Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with mild steel square tube 47x47mm (19 gauge) all as specified and directed. |
| 64 | S & F factory made solid panel PVC door shutters 30 mm thick (style)consisting of frame made out of MS tube for top and bottom rails.MS frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for style and plain colour PVC sheets for top rail, lock rail and bottom rail on either sides & as gap insert for top- rail and bottom rails.Paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement supplying and fixing in the frame at site as per specification and drawing. |
| 65 | S & F of aluminium butt hinges medium weight 100mm type C-21 complete all as specified. |
| 66 | S & F aluminium handle, cast type anodisedsize of handle 125mm ISI marked complete all as specified and directed. |
| 67 | S & F aluminium anodised, barrel tower bolts of extruded section length of bolt 150 mm ISI marked complete all as specified and directed. |
| 68 | S & F of powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified complete all as specified and directed by Engineer-in-Charge. |
| 69 | S & F of Stainless Steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 70 | S & F of sheet glass (frosted on one side) of 4.80mm thick ordinary quality glass and glazing with oil putty in square n exc 0.5 Sqm in each pane complete all as specified and directed. |
| 71 | M & L for 75mm thick cement concrete type-C1 (1:3:6) using 20mm graded aggregate as in path, plinth protection finished surface even and smooth with out using extra cement all as specified and directed. |
| 72 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel 1/2 round or 3/4 pipe section in cement concrete (1:2:4) type B1, smooth finished and reforming benching as required for 100 mm bore pipe complete all as specified and directed. |
| 73 | M & L for cement concrete (1:2:4)type B1 (using 20 mm graded stone aggregate) as in cills, copings, steps, sesmic and other similar bands, coving, bed, plate and the like including weathering, sightly rounded or chamfered angles and throating complete all as specified and directed. |
| 74 | M & L for mild steel TMT bars 8mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 75 | M & L for concrete bed to drain pipes 100mm bore including packing under, and haunching against the sides of pipes after they are laid and tested, in cement concrete (1:4:8) type D-2 complete all as specified and directed. |
| 76 | E&M |
| 77 | M&L for point wiring with 1.5 Sq mmsingle corePVC insulated unsheathedcopper FRLSH multi stranded conductor cable in andincludingConcealed PVC conduitof size 20/25mm ISImarked inclusive oftees ,bend ,elbows etc upto and including sunk in anodized pressed steel box for housing switch socket etc withwhite laminated 3 mm thick hylam sheet cover ISI marked of suitable size complete including PVC insulated multi strandedcopper conductor 1.5Sq mm FRLSH cable as earth wire to common earth dolly for connection to ceiling rose to earth terminalincludingcutting, chasses and makinggooddisturbed surface to match with existing finish with plaster complete all as specified and directed by Engr-in-charge for following :- |
| 78 | (a) One light point controlled by one, one way switch 5 Amps |
| 79 | (b) One fan/exhaust fan point controlled by one, one way switch 5 Amps |
| 80 | (c)One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 81 | (d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. |
| 82 | Description all as per item No 75 here in before butusing 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. |
| 83 | S & F for Switch Piano type single pole 5 amp, 230 Volts complete all as specified and directed at site. |
| 84 | S & F for Switch Piano type single pole 15 amp, 230 Volts complete all as specified and directed at site. |
| 85 | S & F forsocket outlet 2 in 1 , 5 pin, 5 amp, 230 Volts complete all as specified and directed at site. |
| 86 | S & F forsocket outlet 2 in 1 , 5 pin, 15 amp, 230 Volts complete all as specified and directed at site. |
| 87 | S & F for Ceiling rose, surface Bakelite with 3 terminals, ISImarked for batten fitting complete all as specified |
| 88 | S & F for stepped type electronic fan regulator flushType complete all as specified and directed at site. |
| 89 | S & Ffor lamp holder , PVC / Polycarbonate type with back plate suitabl for batten/ slanting fittings complete all as specified and directed. |
| 90 | S & F for sheet metal enclosure MCBDBSPN8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 91 | S & F for MCB Single pole and neutral rated capacity 40 Amps, 240 Volts breaking capacity 10 KA, \"C\" curve complete all as specified and as directed. |
| 92 | S & Ffor MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, \"C\" curve complete all as specified and as directed. |
| 93 | S & F for Highly efficient LED Bulbs, 10 W, used as a ready replacement for existing GLS/CFL direct fit lamp,in B-22 cap of make Bajaj, Havells, HPL complete all as specified and directed |
| 94 | Supply and fixing LED Bldg sec light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 95 | S&F LED integrated batten box type surface mouted, 1x20 Watt prewired including electric electrical connection with PVC insulated twin twistedcopper wire of suitable size from ceiling rose to tube light fitting all as specified and directed. |
| 96 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed. |
| 97 | Supply and fix electric water heater,storage type steel body with copperinner tank and eating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all ccessories such as safety valve, thermostate,NRV, connection piece etc complete all as specified and directed. |
| 98 | Submain wiring 2x6.00 sqmm alongwith 1x4.00 sqmm earth wire of FR is PVC insulated copper conductor, single core cable in surface/ recessed as required complete all as specified and directed. |
| 99 | S&F for ceiling fans complete with blades, down rods,electronic fan regulator and accessories, 230 V, 1200 mm sweep. Min air dilivery 210 CFM with service value 6.00,BEE. Five star rated with brushless direct current motor (BLDC) including connecting up with three core flexible copper conductor cable suitable sizefrom ceiling rose to fan terminal with necessary accessoriescomplete all as specified and directed. |
| 100 | M&L earthing complete with galvanized steel earth plate electrode 60cm x 60cm x6.0 mm thick, burrieddirectly in ground (earth pit not less than 2.25 metres deep belowground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanized earth lead wire 4.0mm dia Protedcted by light GI Pipe 20 mm dia and 15 dia med grade for watering pipe and connected by means of bolts, nuts, check nuts and washers of galvanized iron or steel, iron funnel,Iron pit cover and chamberall as shown in electrical plate No. 3 connected to earthing test point including testing on completion complete all as specified and directed. |