| 1 | Excavation in post holes (or similar holes) each not exceeding 0.5 cum, getting out in soft/loose soil incl returningfilling in ramming earth in layers not exceeding 25cm, and removing surplus excavated soil to a distance n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point and making good surface. |
| 2 | M&L Plain Cement Concrete Type C2 1:3:6 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed. |
| 3 | S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes confirming to IS 1161-1979 Complete all as specified & directed. |
| 4 | S&F steel work in Rooftrusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (hollow tube, angle, channel or flat sections) including distance pieces, cleats etc confirming to Fe-290 (Gde E165) Complete all as specified & directed. |
| 5 | S&F framed work as in gusset plate for framed truss, rafters, rails braces etc complete, drilling for fixing of steel sheeting or other covering, door etc to be prepared for hanging orsliding with and including either hook and hinges or steel hanging door fitting etc with welded, riveted or bolted of Fe-410 Gde 250A complete all as specified and as directed. |
| 6 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 MPA as in roof covering / cladding to wall, fixed with self-tapping screws as specified. |
| 7 | S&FPre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 MPA as in roof covering/cladding to wall, fixed with self-tapping screws as specified. |
| 8 | M&L preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over and including one coatof red oxide zinc chrome primer complete all as specified and directed. |
| 9 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out, complete all as specified and directed. |
| 10 | M&L Hard-core of broken stone and boulders gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 11 | M&L 100 mm thick Cement concrete type D- 2, 1:4:8 (40mm graded aggregate) as in sub base complete all as specified and directed. |
| 12 | M&L Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 13 | M&L machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment confirming to IS 15658-2006 of 80 mm thickness M-40 Grade all as specified |
| 14 | Demolition of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs of any thickness including cover fillets complete all as directed. |
| 15 | S&F Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed. |
| 16 | S&F 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed. |
| 17 | Taking down cement plaster including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed. |
| 18 | M&L rendering 15 mm thick in CM 1:6 on stone masonry surfaces or on other than fair faces of brick masonry finished even and smooth without using extra cement complete all as specified and directed. |
| 19 | M&L for preparing newly plastered surfaces and applying applying two coats of distemper with distemper oil emulsion white or tinted over and including one coat of 1mm thick wall care puttycomplete all as specified and directed. |
| 20 | M&L for brick work with sub class \"B\" bricks straight or curved on plan exc 6m mean radios built in CM (1:4 ) complete all as specified and as directed. |
| 21 | M&L 10 mm thick rendering in cement mortar 1:4 to stone masonry wall surfaces or on other than fair faces of brick wall surfaces finished fair & even without using extra cement for fixing tiles etc complete all as specified and directed. |
| 22 | M&L 25 mm thick PCC 1:2:4 type B-1, using 25 mm graded stone aggregate as in floors, surfaces finished fair and even complete all as specified and directed. |
| 23 | M&L screed bed or bedding layer of mortar, 15 mm thick, in cement mortar 1:6, for laying floor finishes/tiles complete all as specified and directed. |
| 24 | M&L Vitrified ceramic light shade coloured tiles 10mm thick area of each tiles not exc 0.36 Sqm , in floor etc. set & jointed in neat cement slurry & pointed in white or coloured cement to match the shade of the tile complete all as specified and directed. |
| 25 | Dismantling of old brick tiles or terracing tiles, single layer on roofs complete all as specified and directed by Engr-in-charge. |
| 26 | Demolition of existing mud in roofs of any thickness including plastering, old APP sheet and leaping, whether full thickness removed or only a part there of, and removingmud, all rubbish material outside of defence Land as directed by Engr-in-charge. |
| 27 | M&L for PCC (1:2:4) type B-0 using 10/12.5 mm graded stone aggregate laid over roof slab after applying cement slurry for filling undulation finished even and smooth without using extra cement complete all as spd and directed. |
| 28 | M&L for applying cement slurry over existing roof surface @ 3Kg/Sqm complete all as specified and directed. |
| 29 | M&L for 15mm thick rendering in cement mortar 1:4 (mixed with WPC @ 2% by weight of cement) to brick/concrete wall and roof surfaces finished even & smooth (without using extra cement) with water proofing compound at the rate of 3% by weight of cement or as per the manufacturer’s instructions complete all as specified and directed by Engr-in-charge.Note: WPC shall be measured and paid for separately |
| 30 | Supply only integral water proofing compound complete all as specified and directed by Engr-in-charge. |
| 31 | M&L for roof top surface for roof treatment using application of water proofing treatment by authorised applicator complete all as specified and comprising of the followings:-(a) Preparation of roof top surfaces and cleaning all the dust and loose material by brush/grinder including removing of vegetation/plantation from the surface and providing and applying single component elastic cold applied polyurethane modified acrylic roofing system, co-elastic technology (CET) based on modified polyurethane and fully fibre reinforced, having sun reflectivity index (SR) of 109 on top of concrete roof surfaces.(b) All cracks up to 3 mm at corner joints, channel and parapets shall be treated with crack seal. (c) Applying three coats including one coat of primer of polyurethane membrane having coverage @ min 0.75Kg/Sqm and dilution up to 10% and laying reinforced fibre net and applying two coats of polyurethane membrane @ total consumption 2 Kg/Sqm in two coats for maintaining minimum dry film thickness 1.5 mm and elongation at break of free film of approx. 350%. |
| 32 | (d) The materials shall be applied with brush or roller, complete in all respect as per the direction of Engineer -in-charge (Note : 6 Hrs interval between two coat shall be maintained). (e) All auxiliary and accessories involved during application should be supplied by single manufacturer as a part of system. Note : (i) The water proofing treatment shall br carried out by the manufacturer or their authorised applicators duly approved by GE in writing. (ii) Checking the roof slab by any method as per standard engineering practice till total elimination of leakage/ seepage/ dampness shall be removed by the method as per manufacturer’s instructions.(iii) Necessary scaffolding, props, support wherever required deemed to be included in quoted rates as the work shall be executed at height varying from 10-20 mtrs. |
| 33 | Dismantling loose concrete cover of RCC columns, beams, Roof projection, slabs, Chajjas and the like at different bldgs as directed, roughening and cleaning concrete surfaces with steel wire brushes, washed with water and allowed to dry, including dusting of steel reinforcement, providing fabric mild steel wire mesh 75 mm x 75 mm of 1 mm dia as reinforcement to concrete surfaces, applying adhesive/admixture over steel mesh and providing 25 mm thick (average thickness) guniting mix using 1 part of ordinary portland cement 53 grade and 2 parts of river sand mixed with adhesive/admixture at the rate as per manufactures instruction or 2% by wt of cement all as directed with a pressure of 2 to 2.5 kgs per sqm by guniting machine including necessary padding, steel scaffolding and shuttering for working platform/formwork etc including removing of loose cement concrete debris out side of defence land complete all as specified and directed. |
| 34 | S&F 15 mm dia steel water tubing, galvanized, medium grade, with all fittings, fixed to walls and ceiling or in floorincluding taking down GI pipe complete all as specified and directed. |
| 35 | S&F 20 mm dia steel water tubing, galvanized, medium grade, with all fittings,fixed to walls and ceiling or in floorincluding taking down GI pipe complete all as specified and directed. |
| 36 | S&F 500 litres, rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top), hoisted and fixed in position including dismantling water tank complete all as specified and directed by Engineer-in-Charge.(Note : PVC tanks shall be ISI marked and having three layers white colour) |
| 37 | S&F 1000 litres, rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top), hoisted and fixed in position including dismantling water tank complete all as specified and directed by Engineer-in-Charge.(Note : PVC tanks shall be ISI marked and having three layers white colour) |
| 38 | S&F 20mm bore ball brass valve high pressure with polythene float and fly nut complete, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge. |
| 39 | S&F in repair stop valve/Gate Valve 20 mm bore castcopper alloy screwed down high pressure with clutch or butterfly handle both ends complete all as specified and directed by Engr-in-charge. |
| 40 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided including removing debris outside defence land. |
| 41 | M&L for formworkto chullah hoods, chajjas, troughs and similar items including edges with fair finished surfaces of concrete complete all as specified and directed. |
| 42 | M&L for reinforced cement concrete type B0 (1:2:4) (nominal mix) using 12.50 mm graded stone aggregate as in Chajjas, lintel etc |
| 43 | M&L TMT bars 10 mm dia and over, as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spi-rally hooping for columns, hook-ing ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed. |
| 44 | M&L TMT mild steel bars 6 mm to 8 mm dia cut to length bent to shape required including cranking bending spirally for hoping for columns, hooking ends and binding with and including mild steel wire annealed 0.9 mm dia or securing with clips all as specified and directed. |
| 45 | M&L rendering 10mm thick in CM (1:3) on fair faces of ceiling surfaces finished even & smooth without using extra cement and raking out hacking for key scrubbing down with water to receive plaster complete all as specified and directed. |
| 46 | M&L 15mm thick rendering in cement mortar 1:4 to stone masonry wall surfaces or on other than fair faces of brick masonryfinishedeven and smooth without using extra cement complete all as specified and directed. |
| 47 | M&L for 75 mm thick cement concrete type C2 1:3:6 in plinth protection laid in alternate bay forming joints and filling with 1 part of bitumen and 3 part of sand complete all as specified. |
| 48 | M&L for preparation of newly plastered surfaces & applying threecoatsof white wash on ceilings complete as spd & directed |
| 49 | M&L for preparation of new/old surfaces of brick/concrete wall surface by brushing, washing and applying one coat of Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. |
| 50 | Demolition of brick work of any type built in cement mortar in foul condition etc complete all as specified and directed by Engr-in-Charge. |
| 51 | S&F Mild steel work of angle iron or flat iron etc for railings, balusters, nosing to steps including embedding in concrete and screwing etc, flat iron for posts & struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc & similar work conforming to Fe 290 complete all as specified and directed by Engr-in-Charge. |
| 52 | S&F Galvanized, 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia 10 barbs at 75 mm spacing and straining and fixing to any type of standard rail straining bolts, including securing or tying at crossings with and provision of galvanized mild steel wire, staples or steel pins, etc, as directed (each line wire to be measured) complete all as specified and directed by Engr-in-Charge. |
| 53 | M&L for concertina coil reinforced punched (chrome rajor or blade wire) with barbed tap of 0.5 mm thick galvanized steel sheet and core wire of dia 2.5mm high tensile steel wire (coil not less than 8 kg and stretched 5 to 6m) complete all as specified and directed by Engr-in-Charge. |
| 54 | M&L for preparing newly plastered walls surfaces and applying two coats of cement base paint over one coat of white wash complete all as specified and directed by Engr-in-Charge. |
| 55 | Taking down carefully aluminium/copper point wiring on batten or in PVC conduit or in MS conduit with GI earth wire etc (for light, fan, socket or power) complete, including fixture and fitting such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to storefor keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making goodthe disturbedsurfaces of walls, Floors, ceilings etc. complete all as specified and directed by Engr-in-Charge. |
| 56 | Taking down carefully existing sheet metal boxes, cut out, etc of any size any capacity from boards complete and making goodthe disturbed surfaces of walls complete all as specified and directed by Engr-in-charge. |
| 57 | Taking down carefully sub main wiring of size including batten and making good disturbed surface of wall complete all as specified and directed by Engr-in-charge. |
| 58 | M&L complete for wiring with cable of size 1.5 Sqmm single core copper multistrand conductor including continuous earth wire, using cable FRLSinsulated(unsheathed) 1100 volts grade conforming to IS-694 drawn in to and including concealed PVC rigid conduit medium duty with all fittings and fixing accessoriesISI certified IS 9537 part -3 and terminated in to pressed steel metal flushboxes suitable for modular accessories and including modular cover plates with framefor mounting switches, socket regulator, brackets etc andincluding necessary cement work complete all as directed by the Engr in charge including cutting chases pinning in making good to facing and pointing in cement mortar (1:3) to the ends or cutting chases for concealed conduit point wiring and making good disturbed surface complete all as specified and directed by Engr-in-charge. Note: Cutting not exc 4cm girth and 4cm width for one light point controlled by one, one way switch. |
| 59 | Ditto all as per item No. 58 but one fan point controlled by one, one way switch and regulator complete all as specified and directed by Engr-in-charge. |
| 60 | Ditto all as per item No. 58 but one 3 pin socket out let 5 amps independent complete all as specified and directed by Engr-in-charge. |
| 61 | Ditto all as per item No. 58 but one 5 pin 5 amps socket point in same board with other switches complete all as specified and directed by Engr-in-charge. |
| 62 | Ditto all as per item No. 58 but one 3 pin socket out let 16 amps independent but with cable of size 4.0 Sqmm in point wiring and 4.0 Sqmm in continuous earth wire complete all as specified and directed by Engr-in-charge. |
| 63 | M&L for modular switch one way 6 amps 1 module complete all as specified and directed by Engr-in-charge. |
| 64 | M&L for modular switch one way 16 amps1 module complete all as specified and directed by Engr-in-charge. |
| 65 | M&L for modular socket2 in 1, 5 pin 6 amps 2 module complete all as specified and directed by Engr-in-charge. |
| 66 | M&L for modular socket2 in 1, 6 pin 6A/ 16 amp 2 module complete all as specified and directed by Engr-in-charge. |
| 67 | M&L for modular fan regulator stepped type120 watt 2 module . |
| 68 | M&L for ceiling rose surface Bakelite 3 terminal complete all as specified and directed by Engr-in-charge. |
| 69 | S&F for modular metal flush box 3 module including cutting of chassis and making good disturbed surfaces and rate deemed to include in quoted rate complete all as specified and directed by Engr-in-charge. |
| 70 | S&F for modular metal flush box 4 module including cutting of chassis and making good disturbed surfaces and rate deemed to include in quoted rate complete all as specified and directed by Engr-in-charge. |
| 71 | S&F for modular metal flush box 6 module including cutting of chassis and making good disturbed surfaces and rate deemed to include in quoted rate complete all as specified and directed by Engr-in-charge. |
| 72 | S&F for modular white cover plate with frame 3 module complete all as specified and directed by Engr-in-charge. |
| 73 | S&F for modular white cover plate with frame 4 module complete all as specified and directed by Engr-in-charge. |
| 74 | S&F for modular white cover plate with frame 6 module complete all as specified and directed by Engr-in-charge. |
| 75 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engr-in-charge. |
| 76 | M & L complete for sub main wiring with single core copper multi strand conductor FRLS flexible insulated (unsheathed) cable of size 2 x 2.5 sq mm and 1 x 2.5 sq mm as in continuous earth wire drawn in to & including pvc conduit medium 25mm dia ISI marked complete with fittings and fixings accessories laid concealed complete and including necessary cement work complete all as directed by the Engr in charge including cutting chases pinning in making good to facing and pointing in cement moter 1:3 to the ends or cutting chases for concealed conduit sub main wiring and making good disturbed surface complete. Cutting not exc 4cm girth and 4cm width. |
| 77 | M & L complete for sub main wiring with single core copper multi strand conductor FRLS flexible insulated (unsheathed) cable of size 2 x 04 sq mm and 1 x 4 sq mm as in continuous earth wire drawn in to & including pvc conduit medium 25mm dia ISI marked complete with fittings and fixings accessories laid concealed complete and including necessary cement work complete all as directed by the Engr in charge including cutting chases pinning in making good to facing and pointing in cement moter 1:3 to the ends or cutting chases for concealed conduit sub main wiring and making good disturbed surface complete. Cutting not exc 4cm girth and 4cm width. |
| 78 | S&F for single pole with a two pin and earth plug and socket complete with one 20 Amp MCB including electric connection complete all as specified and directed by Engr-in-charge. |
| 79 | Dismantling carefully the indoor unit of existing split AC of 1.5 / 2.0 TR with stabilizers, connected copper pipes, cables, stand and re-installing the same after panelling on wall including repair/ servicing and top up of suitable gas filling etc complete all as specified and directed by Engr-in-charge. |
| 80 | M&Lfor MCB single pole and neutral 240 volts ,C curve-10 kA 32 Amp |
| 81 | M&Lfor MCB single pole 240 volts ,C curve-10 kA 6-32Amp |
| 82 | M&L for 1x 20 watts (4 feet) wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver including lamp complete all as specified and directed by Engr-in-charge. |
| 83 | S&F ceiling fans complete with blades, down rods electronic regulator and accessories 230 V 1200 mm sweep Min air delivery 210 CFM with service value 6.00 BEE 5 star rated with Brushless Direct Current Motor (BLDC) including necessary accessories complete all as specified and directed by Egr-in-Cahrge. |
| 84 | M&L for MCB distirbution board, sheet steel, phosphatised, powder printed with bus bar, neutral link, earth bar & din railSPN dist board 08 ways double door complete all as specified and directed by Egr-in-Cahrge. |
| 85 | M&L for MCB single pole & neutral 240 volts, C curve-10 kA40-60 Amp |
| 86 | M&L for MCB single pole 240 volts,C curve-10 kA16 Amp |