| Sl. No. | Item Description |
| 1 | Dismantling / taking out insulator of any size / type from existing electric LT lines complete. |
| 2 | Unbinding/Broken from insulators ACSR conductor any size of LT/HT over head line for repairs. Re-stretchingof ACSR conductor to achieve proper sag and rebinding to the insulators using alumn/GI binding wire and making all existing cable connections all as required at site. |
| 3 | Dismantling / taking out existing ACSR conductor any size from existing over head lines incl disconnection complete all as directed. |
| 4 | Disconnecting of incoming / outgoing cables of any size and taking out existing unserviceable accessories such as MCCBs, MCBs, Capacitor, APFC controler,Volt meter,Ammeter,selector switch, CTsetc complete all as directed . |
| 5 | Dismantling cross-arms of M.S. channel or angle sections, clamps, nut bolts etc. complete all as specified and directed. |
| 6 | Refixing of serviceable cross arms, channel or angle sections obtained under above item No. 2 including painting of cross arms with two coats of synthetic enamel paint complete all as specified including necessary welding complete all as directed at site. |
| 7 | Material and labour for disconnecting serviceable LT cable of any size and core from LT poles and terminate it into LT panel using suitable aluminium lugs/Copper lugs, cable glands, Slevees and other accessories. The cable shall be laid underground and jointing of cable to be done if falls short to the LT panel complete all as specified and directed by Engr-in-charge.Note: Cost of aluminium lugs, cable glands and termination of cable into LT panel, Slevves shall be included in the quoted rate.(ii) Excavation, returning , refilling , crushed sand, brick cover and jointing kit will be measured and paid seperately. |
| 8 | M & L for disconnecting /Removing the under ground cable binded/Jointed with OH conductor removing carbon cutting of cable size 4 core 10 sqmm to 3.5 core 185 Sqmm and rebinding with the aluminium conductor of suitable size with OH conductor installation on 9/11 meters height pole Note :The scope includes T & P |
| 9 | Material and labour for relaying of existing LT cable of any size up to 50 Sqmm 3.5/4 core under the ground complete all as specified and directed.Note: Excavation, returning , refilling , crushed sand, brick cover will be measured and paid seperately. |
| 10 | Material and labour for relaying of existing LT cable of any size above 50 Sqmm 3.5/4 core to 300 Sqmm 3.5 core under the ground complete all as specified and directed.Note: Excavation, returning , refilling , crushed sand, brick cover will be measured and paid seperately. |
| 11 | Material and labour for relaying of existing LT cable of any size up to 70 Sqmm 3.5/4 core under the ground complete all as specified and directed.Note: Excavation, returning , refilling , crushed sand, brick cover will be measured and paid seperately. |
| 12 | Material and labour for relaying of existing LT cable of any size above 70 Sqmm 3.5/4 core to 300 Sqmm 3.5 core under the ground complete all as specified and directed.Note: Excavation, returning , refilling , crushed sand, brick cover will be measured and paid seperately. |
| 13 | Material and labour forservicing of LT panel duly isolated / de-energize the supply of LT panel of capacity ranging from 200 Amps to 1000 Amps and voltage 415/230 volts. The maintenence includes the following tasks:-(i) Cleaning of burnt Bus bar using CTC chemical.(ii) Taking out all incoming and ougoing cables from the LT panel and also taking out cable loop from ground.(iii) Removing old insulation and providing new heat shrink insulating sleeves, connecting and fixing in the same panel using new GI nut bolts washers of suitable size.(iv) Removing of old and broken cable connectors in the LT panel and providing new connectors of suitable capacity and fixing in the same panel using nut bolts and other accessories.(v) Removing of burnt and worn out lugs from the cables and replace it with new aluminium lugs of suitable size and capacity as per the size of the cable.(vi) Removing of worn out connecting wires inside the panel and replace it with new wires of suitbale capacity and size.Note:Cost of all material as mentioned above required for maintenance must be included in the quoted rate |
| 14 | Repair/ overhauling of LT Air Circuit breakers of any make and capacity 630 to 1000 amps, 3pole/ 4 pole and replacement of minor items like springs, washers, bolts, nuts and other insulating material including calibration and testing of control and protection devices of equipments in the following steps all as directed by Engineer-in-Charge:-(i) Disconnecting and taking out the breaker after taking shut down of the respective panel and check the defects.(ii) Overhauling the ACB by opening all parts and lubricating the moving parts as per requirement.(iii) Re-assembling the air circuit breaker complete, installing to its original position, testing and commissioning the breakers for both tripping and closing mechanism for proper fucntioing of the breaker all as specified and directed |
| 15 | Material and labour for painting to existing steel tubular poles 7/9/11 mtr long including cross arms,looping box,GI pipe bracket,clamps etc. with one coat of aluminium paint including preparation of surfaces and feeder name and pole number with zebra type painting upto 6 feet from bottom with alternate patch of size 1 foot of white and light blue colour paint complete all as directed. |
| 16 | Material & Labour forpainting to feeder pillar box / LT panel & duct coveretc, including angle iron frame with two coat of grey synthetic enamel paint includingwelding of door with proper size new hinges of suitable size and locking arrangementswhere required complete as specified. |
| 17 | Taking down and Supply & fix line separator suitable for LT OH line of 3 phase and neutral conductor complete as specified and directed by Engineer-in-Charge. |
| 18 | All as per item No.17 above but single phase and neutral conductor. |
| 19 | Trimming of trees not exc 30 cm girth including cutting of upper portion of branches and disposal ofsame at a distance not exc 50 mtr and clearing of site complete as directed.(Note:Tools/ladder required for cutting/trimming of trees will be provided by the contractor at no extra cost and cost of the same be deemed to be included in the quoted rate.)Note:Each Span will be measured from one pole to another pole |
| 20 | Provn ofservices for cable fault locationfor LT UG cable, XLPE insulated 1100 Volts, of any size with fault detector machine complete all as specified and as directed. |
| 21 | Material and labour for straight through jointing kits heat shrinkable type LT UG XLPE cable heavy duty armoured sheathed including excavation in any strata, taking out cable, and making disturbed surface after relaying the cable making joints suitable for aluminium conductor of size given below all as specified and directed. |
| 22 | (i) 6 to 16 sqmm 2.0 core |
| 23 | (ii) 6 to 16 sqmm 3.5 core |
| 24 | (iii) 25 to 50 sqmm 3.5 core |
| 25 | (iv) 70 to 120 sqmm 3.5 core |
| 26 | (v) 150- 185 sqmm 3.5 core |
| 27 | (vi) 240-300 sqmm 3.5 core |
| 28 | Supply and fix HDPE Pipe 100/110mm PE 100 Grade pipePN 8 (SDR 17)with all connected accessoriesof sizes100 mm completed as directed |
| 29 | Supply and fix HDPE Pipe 50 mm PE 100 Grade pipePN 8 (SDR 17)with all connected accessoriesof sizes100 mm completed as directed |
| 30 | Taking down and S&F shackle type insulator vitreous procelain white / brown / greenwith and including galvanised mild steel straps, washer insulator, bolts and nuts, insulator of size 100 mm height and 115 mm max dia with working pressure 1100 volt and galvanised steel straps 3 to 5 mm size and suitable size nut and bolts all as directed and as specified. |
| 31 | M&L for taking down old unsv insulator and supply and fix pin type procelain white / brown / green / insulator including galvanised mild steel spindle, two galvanised iron.Washer and one galvanised iron nut, 100mm height 65 mm dia for 1100 volts grade all as directed. |
| 32 | Supplying, spreading & leveling stone aggregate size of 20 mm grade to the existing sub station or all as specified and directed by Engineer-in-Charge. |
| 33 | Taking down and Supply and fix in repair / replacement of MCCB FP 630 Amps Adjustable type with breaking capacity50 KAincluding connections and testing for proper functioning complete all as specified and directed. |
| 34 | Taking down and Supply and fix in repair / replacement of MCCB FP 400 Amps Adjustable type with breaking capacity36 KAincluding connections and testing for proper functioning complete all as specified and directed. |
| 35 | Taking down and Supply and fix in repair / replacement of MCCB FP 250 AmpsAdjustable type with breaking capacity36 KAincluding connections and testing for proper functioning complete all as specified and directed. |
| 36 | Taking down and Supply and fix in repair / replacement of MCCB FP 200 AmpsAdjustable type with breaking capacity36 KAincluding connections and testing for proper functioning complete all as specified and directed. |
| 37 | Taking down and Supply and fix in repair / replacement of MCCB FP 160 AmpsAdjustable type with breaking capacity36 KA including connections and testing for proper functioning complete all as specified and directed. |
| 38 | Taking down and Supply and fix in repair / replacement of MCCB TP 200 Amps Adjustable type with breaking capacity25 KAincluding connections and testing for proper functioning complete all as specified and directed. |
| 39 | Taking down and Supply and fix in repair / replacement of MCCB TP 160 Amps Adjustable type with breaking capacity25 KAincluding connections and testing for proper functioning complete all as specified and directed. |
| 40 | Taking down and Supply and fix in repair / replacement of MCCB TP 100 Amps Fixed type with breaking capacity 16 KAincluding connections and testing for proper functioning complete all as specified and directed. |
| 41 | Supplying, Laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE(cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specifiedfor following size:- |
| 42 | (a)6 sqmm 4 core |
| 43 | (b)10 sqmm 4 core |
| 44 | (c)16 sqmm 4 core |
| 45 | (d)25 sqmm 4 core |
| 46 | (e)35 sqmm 3.5 core |
| 47 | (f)50 sqmm 3.5 core |
| 48 | (g)70 sqmm 3.5 core |
| 49 | (h)95 sqmm 3.5 core |
| 50 | (j)120 sqmm 3.5 core |
| 51 | (k)185 sqmm 3.5 core |
| 52 | (l)240 sqmm 3.5 core |
| 53 | (m)300 sqmm 3.5 core |
| 54 | Excavation in trenches not exc 1.5 m wide andnot exc 1.5 m in depth and getting it out for laying of cable / pole etc. |
| 55 | Soft/loose soil |
| 56 | Hard/dense soil |
| 57 | Soft/disintegrated rock |
| 58 | Returning/ Refilling of excavated soil including spreading levelling and well ramming in layers for any type of soil. |
| 59 | Removing the surplus spoil to a distance not exceeding 50 mtrs from the starting point and depositing at a height not exceeding 1.5 m above ground level. |
| 60 | Material and labour for stone dust sand cushioning to under ground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable all as specified and directed.[Note : Measuremenet will be done after punning] |
| 61 | M&L for brick protection covers laid over cables of sub class\"B\" bricks all as specified and directed. |
| 62 | Supply and fixing MCBDB TPN 4 wayIP 43-IK-09 with metal double door suitable forhousing of MCBs completeall as directed by Engineer-in- Charge. |
| 63 | S&F MCB TPN 63 Amp 10 kA 415 Volt, \"C\" Curve and electric connections with copper thimbles complete all as specified and directed by Engr-in-Charge. |
| 64 | S&F MCB DP 40-63 Amp 10 kA 240 Volt, \"C\" Curve and electric connections with copper thimbles complete all as specified and directed by Engr-in-Charge. |
| 65 | M&L for MCB SP 6-32 Amps C curve and electric connections with copper thimbles complete all as specified and directed by Engr-in-Charge. |
| 66 | Taking down and Supply and fix in repair / replacement of heavy duty resin filled capacitor 440 volt 3 ph of capacity 10 KVAR including connections and testing for proper functioning complete all as specified and directed. |
| 67 | Taking down and Supply and fix in repair / replacement of heavy duty resin filled capacitor 440 volt 3 ph of capacity 15 KVAR including connections and testing for proper functioning complete all as specified and directed. |
| 68 | Taking down and Supply and fix in repair / replacement of heavy duty resin filled capacitor 440 volt 3 ph of capacity 20 KVAR including connections and testing for proper functioning complete all as specified and directed. |
| 69 | Taking down and Supply and fix in repair / replacement of heavy duty resin filled capacitor 440 volt 3 ph of capacity 25 KVAR including connections and testing for proper functioning complete all as specified and directed. |
| 70 | Taking down and Supply and fix in repair / replacement of heavy duty resin filled capacitor 440 volt 3 ph of capacity 30 KVAR including connections and testing for proper functioning complete all as specified and directed. |
| 71 | Taking down and Supply and fix in repair / replacement of APFC Controller for contactor switching with 1 CT input4 Step including connections and testing for proper functioning complete all as specified and directed. |
| 72 | Taking down and Supply and fix in repair / replacement of APFC Controller for contactor switching with 1 CT input6 Step including connections and testing for proper functioning complete all as specified and directed. |
| 73 | Taking down and Supply and fix in repair / replacement of CT 200/5A CL1 5VA including connections and testing for proper functioning complete all as specified and directed. |
| 74 | Taking down and Supply and fix in repair / replacement of CT 100/5A CL1 5VA including connections and testing for proper functioning complete all as specified and directed. |
| 75 | Taking down and Supply and fix in repair / replacement of digital VAF & PF meter CL1including connections and testing for proper functioning complete all as specified and directed. |
| 76 | Taking down and Supply and fix in repair / replacement of Capacity duty contactors 440 V, 3Ph, 50 Hz suitable for 10 KVAr capacitor bankincluding connections and testing for proper functioning complete all as specified and directed. |
| 77 | Taking down and Supply and fix in repair / replacement of Capacity duty contactors 440 V, 3Ph, 50 Hz suitable for 15 K VAr capacitor bankincluding connections and testing for proper functioning complete all as specified and directed. |
| 78 | Taking down and Supply and fix in repair / replacement of Capacity duty contactors 440 V, 3Ph, 50 Hz suitable for 20 KVAr capacitor bankincluding connections and testing for proper functioning complete all as specified and directed. |
| 79 | Taking down and Supply and fix in repair / replacement of Capacity duty contactors 440 V, 3Ph, 50 Hz suitable for 25 KVAr capacitor bankincluding connections and testing for proper functioning complete all as specified and directed. |
| 80 | Taking down and Supply and fix in repair / replacement of Capacity duty contactors 440 V, 3Ph, 50 Hz suitable for 30 KVAr capacitor bankincluding connections and testing for proper functioning complete all as specified and directed. |
| 81 | Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 25 X 4 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plateNo. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab cover 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm),funnel with wire mesh, watering pipe of 20 mm bore medium grade, including galvanised iron strip 25X4 mm with GI protection pipe of 40 mm medium grade up to 7.5 meter length, etc complete all as specified. |
| 82 | M& L for testing of APFC panel for proper functioning in manual & auto mode, including re-wiring the burnt out wires, replacing the wiring ducts/casing capping, fuse units and cleaning and testing complete all as specified and directed by Engr-In-Charge. |
| 83 | Preventive Maintenance and Servicing of Servo Voltage Stabilizer, Oil Cooled & Indoor type of Capacity 10 to 75 KVA, 415 Volts, 50 Hz, AC Supply by disconnecting carefully its electric cable connection on primary & secondary side, Checking both side bushing, bus bar connections, opening top cover of the Voltage Stabilizer by unscrewing its nuts, bolts, washers etc, rectify the oil leakages issues, if noticed any, during servicing and re-fixing the top cover of voltage stabilizer according to previous system.Servicing of the Servo Voltage Stabilizer must be done through OEM or authorised personnel including maintaining and submitting the inspection and testing records of each Servo Voltage Stabilizer to the Engr-in-Charge. Note 1. :-Inspection of Servo Voltage Stabilizer shall involve :-(a) Checking of all clamps, nuts, bolts including core bolts & cover fixing bolts etc.(b)Checking all brazings, joints, tap heads, gaskets and connection joints etc.(c)Checking all terminations / connections inside Voltage Stabilizer.(d)Checking moving and fixed contacts for contact wear and connection to winding etc.(e)Conducting the test on dimmer/windings as per relavent IS like, short circuit, IR Value and Voltage regulation test etc. in presence of Engr-in-Charge.Note 2. :The rates quoted against the item is deemed to be included for cost of Labour for lifting/transporting to civil workshop and vice-versa, if required as per site requirement without any extra cost to the department. |
| 84 | All as per item No. 62 above but capacity 100 to 200 KVA, |
| 85 | All as per item No. 62 above but of capacity 400 to 630 KVA, |
| 86 | S & F in replacement Sensing Control Card, 240 Volts, 50 Hz, AC, suitable /compatible to existing Servo Voltage Stabilizer, Oil Cooled type,of capacity 10 to 75 KVA complete all as specified and directed. |
| 87 | All as per item No. 65 above but capacity 100 to 200 KVA. |
| 88 | All as per item No. 65 above but capacity 400 to 630 KVA. |
| 89 | S & F in replacement Servo Motor, 1-ph, 240 Volts, 50 Hz, AC, suitable /compatible to existing Servo Voltage Stabilizer, Oil Cooled type,of capacity 10 to 75 KVA complete all as specified and directed. |
| 90 | All as per item No. 68 above but capacity 100 to 200 KVA. |
| 91 | All as per item No. 68 above but capacity 630 KVA. |
| 92 | S & F in replacement Selector Switch, stepwise selection, 10 Amps, 240 Volts, 50 Hz, AC, suitable /compatible to existing Servo Voltage Stabilizer, Oil Cooled type, of capacity 10 to 75 KVA. |
| 93 | All as per item No. 71 above but capacity 100 to 200 KVA. |
| 94 | All as per item No. 71 above but capacity 400 to 630 KVA. |
| 95 | S & F in replacement Volt Meter, analog type, range from 0 to 260 Volts, suitable /compatible to existing Servo Voltage Stabilizer, Oil Cooled type, of capacity 10 to 75 KVA. |
| 96 | All as per item No. 74 above but capacity 100 to 200 KVA. |
| 97 | All as per item No. 74 above but capacity 400 to 630 KVA. |
| 98 | S & F in replacement Volt Meter, analog type, range from 0 to 660 Volts, suitable /compatible to existing Servo Voltage Stabilizer, Oil Cooled type of capacity 10 to 75 KVA.complete all as specified and directed |
| 99 | All as per item No. 77 above but capacity 100 to 200 KVA. |
| 100 | All as per item No. 77 above but capacity 630 KVA. |
| 101 | S & F in replacement control wiring of 1.5 Sqmm single core multi-stranded FRLS copper conductor insulated with heat shrinkable PVC sleeve taggedand secured for indicators / meters/Voltage Stabilizers etc including suitable size of copper lugs, PVC cable ducts, galvanised or cadmium plated high tensile nuts, bolts and washers etc complete all as specified and directed. |
| 102 | Supply and top up of voltage stabilizer/Isolation Transformeoil with di-electric strength not less than 50 KV in to the body tank of the voltage stabilizer at various locations complete all as directed by the Engineer-in-Charge and also submit the test result before and after the top up. |
| 103 | M & L for dehydration/filteration of voltage stabilizer/Isolation Transformeroil at site by taking proper shutdown of various capacity of Voltages Stabilizers located at various Sub Stations inside Air Force Stn Pune, desired di-electric strength of oil not less then 50 KV complete all as directed and specified and also submit the test result before and after the de-hydration of the stabilizer oil complete all as specified and directed. |
| 104 | S & F in replacement ampere meter including suitable size of CTs, ring type, 240 Volts, 50 Hz, AC,suitable /compatible to existing Servo Voltage Stabilizer, Oil Cooled type of capacity 10 to 75 KVA.complete all as specified and directed |
| 105 | All as per item No. 83 above but capacity 100 to 200 KVA. |
| 106 | All as per item No. 83 above but capacity 400 to 630 KVA. |
| 107 | Supply and re-winding Super enamelled Copper winding wire as per sample given or suitable / compatible to existing servo voltage stabilizer, Oil Cooled type of any capacity/ make and re-winding the defective coils/dimmer assembly with new copper wire as per relevant I.S. of same gauge and existing size together with new insulated materials/ bracings before placing in to the voltage stabilizer and assembling the coil with new insulation and fitting the coils in the chamber, testing and commissioning the voltage stabilizer and recording the test results complete all as specified and directed |
| 108 | M & L for replacement Super enamelled Iron core as per sample or suitable/compatible to existing Servo voltage stabilizer, Oil Cooled type of any capacity/make by re-assembling the defective iron core with new iron core as per relevant I.S. of same gauge and existing size together with new materials/ bracings before placing in to the voltage stabilizer and assembling the iron core with new insulation and fitting the coils in the chamber, testing and commissioning the voltage stabilizer and recording the test results complete all as specified and directed |
| 109 | M & L for re-insulation/re-varnishing of super enamelled copper winding wire of existing copper winding/dimmer stat assemblyor suitable/compatible to existing Servo voltage stabilizer, Oil Cooled type of any capacity/make by re-assembling the defective Copper winding with new copper winding as per relevant I.S. of same gauge and existing size together with new materials/ bracings before placing in to the voltage stabilizer and assembling the Copper winding/dimmer stat assembly with new insulation and fitting the coils in the chamber, testing and commissioning the voltage stabilizer and recording the test results complete all as specified and directed |
| 110 | Preventive Maintenance and servicing by opening the top cover of the Voltage stabilizer, air cooled type, capacity 10 to 75 KVA, 415 Volts, 50 Hz, AC andchecking the all control wiring and cleaning internally by applying air pressure through blower and ensure testing voltage, current, Earthing, \Minor patrsetc complete all as specified and directed.Note : Servicing must be done through OEM or authorised personnel. |
| 111 | All as per item No. 89 above but capacity 100 to 200 KVA. |
| 112 | All as per item No. 89 above but capacity 400 to 630 KVA. |
| 113 | M&L for PCC 1:4:8 for area around existing panelincluding necessary foam work, curing |
| 114 | Taking down, Supply install, test and commissioning of Powder coated LTpanel cubical out door type free standing type compartmentalized in construction fabricated from CPRI approved manufacturer specified in particular specification and made out of 3 mm thick CRCA sheet & suitable size to accomodate all accessories / fittings, to accommodate incoming MCCB and TPN Aluminium bus bars, incomer MCCB and outgoing feeder.The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. Thecubicle shallhavefree standing bottom frame/stand of height 600mm & dimension as required for panel & shall be made out of equal angle iron of size 50mm x 50mm x 6mm. A detachable predrilled gland plate of thickness not less than 3 mm thickpowder coated should be used at thebottom for entry of armoured cableof adequate size with glands.The above panel shall be front & back openable lockable /openable by key from both side. Copper extension link shall be provided at incomer & outgoing end of MCCB of rating 100 Amps & above. The panel shall be powder coated of approved thickness complete including CTs, control wiring by 1.5Sqmm Wire, including taking down of old unsv panel after disconnecting Existing cable & Reconnecting the cables to new panels including providing cable glands, lugs, nut bolts etc, grouting bolts, the panel shall comprise of following and including demolition of existing PCC foundation, complete all as specified & directed by Engineer in Charge. |
| 115 | a) TPNAluminumbusbar with colour code 600 APMSb) Incomer MCCB FP 400 Amps415 Volt 36 KA - 1 Nosc) Outgoing MCCB TP 200 Amps - 415 Volt 25 KA- 2 Nos d) Outgoing MCCB TP 100 Amps - 415 Volt 25 KA- 3 Nose) RYB Indicators - 1 Set |
| 116 | Taking down, Supply install, test and commissioning of Powder coated LTpanel cubical out door type free standing type compartmentalized in construction fabricated from CPRI approved manufacturer specified in particular specification and made out of 3 mm thick CRCA sheet & suitable size to accomodate all accessories / fittings, to accommodate incoming MCCB and TPN Copper bus bars, incomer MCCB and outgoing feeder.The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. Thecubicle shallhavefree standing bottom frame/stand of height 600 mm & dimension as required for panel & shall be made out of equal angle iron of size 50mm x 50mm x 6mm. A detachable predrilled gland plate of thickness not less than 3 mm thickpowder coated should be used at thebottom for entry of armoured cableof adequate size with glands.The above panel shall be front & back openable lockable /openable by key from both side. Copper extension link shall be provided at incomer & outgoing end of MCCB of rating 100 Amps & above. The panel shall be powder coated of approved thickness complete including CTs, control wiring by 1.5 Sqmm Wire, includingdisconnecting Existing cable & Reconnecting the cables to new panels including providing cable glands, lugs, nut bolts etc, grouting bolts, the panel shall comprise of following and including demolition of existing PCC foundation, complete all as specified & directed by Engineer in Charge. |
| 117 | a) TPNCopper busbar with colour code 400 APMSb) MCCB FP 63 Amps 415 Volt25 KA - 2 Nos (Incommer)c) 32 Amps Four pole contactor with NO + NC add on block- 4 setd) MCB FP 63 Amps 10 kA - 2 Nos e) MCB TPN 16 Amps 415 Volt16 kA - 3 Nosf) MCB DP 16 Amps 240 - 5 Nosg) MCB DP 25 Amps, - 1 Noh) MCB DP 6 Amps- 2 Nosj) 10 Amps AC coil control relay 2 NO + 2 NC type - 1 No k)Timer switch with auto/manual mode facility alongwith control wiring-01 set. l)Selector switch for slection of Input source with circuit - 01 Setm)RYB Indicators - 1 Setn) Surge rptection device 3 Phase type 2 - 01 No |
| 118 | All as per item no 95 but with the following acessoriesa) Copper busbar, 200 Amps - 01 Set(Busbar for phase & neutral shall be provided at outgoing side of Incommer for tapping supply to outgoing MCB) b) RCCB DP 6 Amps - 01 No (Incommer)c)RCCB DP 16 Amps - 01 No e)MCB DP 6 Amps - 04 Nos , f)MCB DP 10 Amps - 02 Nos g) MCB DP 16 Amps - 02 Nos h)Necessery copper wiring as required. j) Panel Indicators - 1 Set |
| 119 | All as per item no 95 but with the following acessoriesa) Copper busbar, 200 Amps - 01 Set(Busbar for phase & neutral shall be provided at outgoing side of Incommer for tapping supply to outgoing MCB)b) MCB SPN - 40 Amps- 01 No c)MCB SP 20 Amps - 03 Nos d) MCB SP 10 Amps - 06 Nose)Necessery copper wiring as required. f) Panel Indicators - 1 Set Note for item No 94, 95, & 96(i)The lay out drawing of the panel shall be got approved by the contractor before panel fabrication and shall be fabricated from CPRI approved manufacturer(ii)Fixing of MCCB/RCCB/MCB and Wiring shall be done as per existing Panel/DB at Gliderpath.Contractor shall collect ----from site and prepare wirimg diagram as per existing panel and shall submitted for approval. (iii)Panel/DB shall be covered with Bird Spikes at the top of the panel/DB. Rate deemed to be included in the quated rate |
| 120 | Supply and laying in trenches or fixing to wall/pole/ducts or passing through pipe PVC insulated heavy duty electric cable with Un armoured Copper conductor1100 volts grade cross sectional area 4 Sqmm 4 core. |
| 121 | Supply and laying in trenches or fixing to wall/pole/ducts or passing through pipe PVC insulated heavy duty electric cable with Un armoured Copper conductor1100 volts grade cross sectional area 6 Sqmm 4 core. |
| 122 | S&F in replacement 20 mm dia rigid non metallic PVC conduit heavy duty 2mm wall thickness exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock, nuts, saddles, pipe hooks etc complete. |
| 123 | S & F 0.63 mm thick Galvanised corrugated mild steel sheeting wth two corrugations side lap, fixed with coach screws washers in roofs walls etc with grade of zine coating 275 |
| 124 | M&L Hand rails, half round or other steel section or core for wooden hand-rail straight protion drilled and countersunk for balusters running bars for doors, balusters, nosing to steps includingembedingin concrete and screwing etc. wind ties for roof, Brackets for valley gutters, including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc) including all necessery drilling, bolting or riveting etc. and similar work conforming to Fe 410-0 or FE 310-0 |
| 125 | M&L for preparation of new steel surface over 10 cm width or girth and applying two coats of synthetic enemel paint over a coat of red oxide, zinc chrome primer all as directed and specified |
| 126 | M&L applying two coats of Camouflage pattern synthetic enamel painting to new surfaces steel/CGI sheet surface exc 10 cm width/grith over a coat of mordant solution including preparation of surfaces by removal of galvanisation if reqd, washing and cleaning, including filling with filler where reqd all as specified and directed. |
| 127 | M&L PCC 1:3:6 type C-2 (using 20 mm graded stone aggregate) 75 mm thick sub base |
| 128 | M&L pre-cast cement concrete (20 mm aggregate) 75 mm thick sub base |
| 129 | M&L cement concrete 1:2:4 type B2 (using 40 mm graded stone aggregate) 1:3:6 type C-1 as in block masonery with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6 all as specified and directed |
| 130 | Taking down the existing street light fitting and Supply & fix (inRepalcement)energy saving and environmental friendly long life LEDStreet light fitting35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete withimpact and corrosion resistant including thermalmanagement in multiple opticsIP 65/IP66 road way luminarieswith LEDs as light source and lensembedded, toughened glass coverand impact resistance of IK07 and electronic driver with surge protector fixed on pole on existing bracket including connection complete all as specified and directed. |
| 131 | -ditto- all as per item Ser No 107 above but 60 Watt complete all as specified and directed |
| 132 | -ditto- all as per item Ser No 107 above but 70 Watt complete all as specified and directed |
| 133 | -ditto- all as per item Ser No 107 above but 90 Watt complete all as specified and directed |
| 134 | Taking down the existingFlood lights fitting and Supply & fix (inRepalcement)energy saving and environmental frindly long life exclusive innovative flood light luminaries 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant with LEDs as light source and lensembedded on each LED, toughened glass cover and impact resistance of IK07 and electronic driver with surge protectorfixed on high mast poleor any any other place as requird on site incl making all nacessary arrangement for fixing complete with MS flat iron clamps (clamp shall be 40x5 mm MS flat), nuts and bolts and washers complete all as specified and directed. |
| 135 | -ditto- all as per item Ser No 111.00 above but 120 Watt complete all as specified and directed |
| 136 | -ditto- all as per item Ser No 111.00 above but 170/180 Watt complete all as specified and directed |
| 137 | -ditto- all as per item Ser No 111.00 above but 200/210 Watt complete all as specified and directed |
| 138 | Taking down old,rusted, unsv Junction boxof any size, type and supply & fix new junction box of size not less than 210 mm x180 mm x 90 mm, made out of Fibre material, shockproof and rustproof, cable entry from bottom. 100% wheather proof and fixing to pole etc using suitable GI clamps of size 25x3mm, nuts, bolts etc for accommodating and including the following complete all as specified and directed:-a)TPN Connector 32 A b) MCB SP 6A-01 Nos |
| 139 | S&F in replacement of PVC insulated 1.5 sqmm copperthree core conductor cable between cable loops box to fitting drawn through the pole complete all as specified and directed |
| 140 | S&F along pole PVC non metallic conduit of dia 20 mm medium grade including MS clamps and nut bolts etc for fixing along the pole complete all as specified and directed |
| 141 | M&L for scrapping of old aluminium paint of steel tubular pole 9/11 mtr by means of emery paper for preparation of smooth surfaces andpainting with two coats of aluminium paint on pole , brackets old junction boxes channels etc inclalternate 30 cm wide white andblue strip painting up to 1.5 Mtr height from ground level complete all as specified and directed. |
| 142 | Material and labour for Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out removing of grass and vegetation grown around the electrical installations like transformers, LT panels, 2 pole structure, HT panels area inside the fencing complete all as specified and directed. |
| 143 | Taking down the existinghighbay light fitting and Supply & fix (inRepalcement)energy saving and environmental friendly robost IP 65 protected LED midbay with PDC housing suitable for ceiling (Surface/Suspended)mount 120 Watt with system efficiencynot less than 120 lm/W incl electronicdriverfixed inceiling/ suspended incl making all nacessary arrangementfor fixing/hanging and ancheringas required on sitemaking electrical connections complete all as specified and directed. |
| 144 | Supply and fix in repair / replacement of MCCB TP 63 AmpsFixed type with breaking capacity16 KAincluding connections and testing for proper functioning complete all as specified and directed. |
| 145 | Supply and fix MCB SPN 40 Amp, 230 volt \"C\" series complete all as specified and directed. |
| 146 | S&F in replacement of old unserviceable contactor ML-3,40 Amps power operating voltage 415 V AC Capacity. complete all as specified and directed |
| 147 | M&L for cement concrete (1:2:4) type B1 in foundation filling and mass concrete and coping of poles or as per site reuirement at electical installations complete all as specified and directed incl necessary form work using 20 mm graded stone aggregate etc |
| 148 | M&L for fixing in repairs for 24 Hrs 240V FM1 Quartz type daily timer for controlling street lights contactor complete all as specified and directed by Engr-In- Charge. |
| 149 | Cleanig of solar street light PV panel mounted on pole of any height for better efficiency of solar light ON MONTHLY BASIScomplete all as directed. |
| 150 | Material and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm as earthing lead buried directly in ground vertically in a pit of depth not less than 2.25 metre below ground level with the top edge of earth plate at a depth not less than 1.5 m below normal ground level, connected to and including galvanised iron earth lead wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel, and connected to earthing test point, providing charcoal and common salt all as shown in electrical plate no. 3 of SSR part I, and testing on completion including excavation and earth work in any type of soil, PCC 1:3:6 type C1 earthing chamber, precast slab 50 mm thick in cement concrete 1:2:4 type B1 reinforced with welded steel wire fabric (XPM) weight not less than 4kg/sqm, funnel with wire mesh, watering pipe of 20 mm bore medium grade GI pipe and lugs, earthing wire protected by galvanised iron or steel pipe 15 mm dia medium grade 7.5 metre long complete all as specified and as directed. |
| 151 | Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 25 X 4 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plateNo. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab cover 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm),funnel with wire mesh, watering pipe of 20 mm bore medium grade, including galvanised iron strip 25X4 mm with GI protection pipe of 40 mm medium grade up to 7.5 meter length, etc complete all as specified. |
| 152 | M&L for servicing of DG set 62.5 KVA to 125 KVA by taking out U/S spares, Cleaning by brushing to remove dust including replacing of diesel filters,lub oil filters,checking of all nuts, bolts tightening wherever necessary,draining out old engine oil and coolant and filling new engine oil and coolant as required at site, adjustment and replacement of belt,tuning of engine, adjustment of speed, alternator voltage, frequency etc greasing oiling and checking for smooth functioning of DG Set complete all as specified and directed.Note:1. Spare & Materials such as engine oil, coolant, unserviceable spares required to be replaced during servicing shall be measured separately under respective items. 2. Minor spares like nuts, bolts etc cost upto 200 Rs shall be included in the rate quoted above. |
| 153 | M&L for servicing of DG set 160 KVA to 250 KVA by taking out U/S spares, Cleaning by brushing to remove dust including replacing of diesel filters,lub oil filters,checking of all nuts, bolts tightening wherever necessary,draining out old engine oil and coolant and filling new engine oil and coolant as required at site, adjustment and replacement of belt,tuning of engine, adjustment of speed, alternator voltage, frequency etcgreasing oiling and checking for smooth functioning of DG Set complete all as specified and directed.Note:1. Spare & Materials such as engine oil, coolant, unserviceable spares required to be replaced during servicing shall be measured separately under respective items. 2. Minor spares like nuts, bolts etc cost upto 200 Rs shall be included in the rate quoted above. |
| 154 | M&L for servicing of DG set 500 KVA to 750 KVA by taking out U/S spares, Cleaning by brushing to remove dust including replacing of diesel filters,lub oil filters,checking of all nuts, bolts tightening wherever necessary,draining out old engine oil and coolant and filling new engine oil and coolant as required at site, adjustment and replacement of belt,tuning of engine, adjustment of speed, alternator voltage, frequency etc greasing oiling and checking for smooth functioning of DG Set complete all as specified and directed. Note:1. Spare & Materials such as engine oil, coolant, unserviceable spares required to be replaced during servicing shall be measured separately under respective items. 2. Minor spares like nuts, bolts etc cost upto 200 Rs shall be included in the rate quoted above. |
| 155 | Material only for the following item of DG set62.5 KVA to 125 KVA DG set be incorporated in repairs for item No 23.00 and 99 complete all as specified and directed. |
| 156 | (a) Fuel Filter |
| 157 | (b)Oil Filter element with \"O\" ring |
| 158 | (c) Fan belt |
| 159 | (d) Alternator belt |
| 160 | (e) Radiator hose pipe inlet/outlet |
| 161 | (f) Solenoid switch 12 volts,DC |
| 162 | (g) Oil Pressure Pipe |
| 163 | (h) Fuel Pressure Pipe |
| 164 | Material only for the following item of DG set 160 KVAto 250 KVA to be incorporated in repairs for item No 24.00 and 100 complete all as specified and directed. |
| 165 | (a) Fuel Filter |
| 166 | (b) Oil Filter element with \"O\" ring |
| 167 | (c) Fan belt |
| 168 | (d) Alternator belt |
| 169 | (e) Radiator hose pipe inlet/outlet |
| 170 | (f) Solenoid switch 12/24 volts,DC |
| 171 | (g) Oil Pressure Pipe |
| 172 | (h) Fuel Pressure Pipe |
| 173 | Material only for the following item of DG set 500 KVA to 750 KVA to be incorporated in repairs for item No 25.00 and 101 complete all as specified and directed. |
| 174 | (a) Fuel Filter |
| 175 | (b)Oil Filter element with \"O\" ring |
| 176 | (c) Fan belt |
| 177 | (d) Alternator belt |
| 178 | (e) Radiator hose pipe inlet/outlet |
| 179 | (g) Oil Pressure Pipe |
| 180 | (h) Fuel Pressure Pipe |
| 181 | M &L for Removing the fuel injection pump (FIP) & injectors from DG set cap 62.5 KVA to 200 KVA and carry out servicing and calibration including replacement of injectors nozzles, etc. and refitting the same for smooth and efficient functioning complete all as specified and directed. Note :-Repairs will be carried out from authorised workshop. |
| 182 | Taking down defective self starter 12 Volt of DG set of cap from 62KVAand below160 KVA DG set installed at various installations and servicing/overhauling including replacing of worn out parts like solenoid, bearing, carbon brush, rewinding the starter motor winding, etc. and refitting the same after making serviceable for smooth functioning complete all as specified and directed.Note:-Spares required and rewinding will be measured and paid separately under relevant item of this Schedule here after. |
| 183 | (a) Rewinding the burnt field coil. |
| 184 | (b) Rewinding the burnt armature coil with commutator. |
| 185 | (c) Replacement of bush/ bearing. |
| 186 | (d) Replace the worm out carbon brush with brush holder. |
| 187 | (e) Replacement of clutch. |
| 188 | (f) Replacement of solenoid switch. |
| 189 | (g) Replacement of Bentex drive. |
| 190 | Taking down defective self starter 24 Volt of DG set of cap from 200 KVA to 750 KVA DG set installed at various installations and servicing/overhauling including replacing of worn out parts like solenoid, bearing, carbon brush, rewinding the starter motor winding, etc. and refitting the same after making serviceable for smooth functioning complete all as specified and directed.Note:-Spares required and rewinding will be measured and paid separately under relevant item of this Schedule here after. |
| 191 | (a) Rewinding the burnt field coil. |
| 192 | (b) Rewinding the burnt armature coil with commutator. |
| 193 | (c) Replacement of bush/ bearing. |
| 194 | (d) Replace the worm out carbon brush with brush holder. |
| 195 | (e) Replacement of clutch. |
| 196 | (f) Replacement of solenoid switch. |
| 197 | (g) Replacement of Bentex drive. |
| 198 | M&L for disconnecting the U/S alternator capacity of 62.5 KVA to 160 KVA, 3 phase any make & type from engine, transporting to workshop dismantling it for repairing and rewinding by taking out burnt armature winding aleaning the alternator coil with existing gauge/size of super enamelled copper winding wire, providing new insulation, sleeves, varnishing cotton taping etc reassembling the alternator complete including aligning with engine and testing in all aspects for smooth functioning complete all as specified and directed. |
| 199 | Taking down old US contactor and S&F new contactor for the following range complete all as specified and directed. |
| 200 | (i) MNX 40 contactor 40A, 415 volt, 3 pole |
| 201 | (ii) MNX80 contactor 80A, 415 volt, 3 pole 2NO+2NC |
| 202 | (iii) MNX225 contactor 225 A, 415 volt, 3 pole 2NO+2NC |
| 203 | Material and labour for replacement of battery charger 12 Volt,10 Amp and making all electrical connection testing complete all as specified and directed. |
| 204 | Material and labour for replacement of battery charger 24 Volt, 10 Amp and making all electrical connection testing complete all as specified and directed. |
| 205 | M & L for replacement ofbrass battery terminal suitablefor lead Acid Battery 12 V 40 AH to 12 V , 180 AH complete all as specified and directed. |
| 206 | M & L for maintenance servicing and complete checking of automatic main failure (AMF) panel of any capacity including replacement of worn out parts, copper cables, relay of suitable range, toggle switches, indicator & repair of Ammeter, Voltmeter complete and testing complete all as specified and directed.Note :- Spare parts required will be measured and paid separatelyunder relevant item of this Schedule here after. |
| 207 | (a)Toggle switch suitable for AMF panel. |
| 208 | (b)CT\"s of range 62.5 to 400 KVA |
| 209 | (c)Relay of range 62.5 KVA to 400 KVA. |
| 210 | (d)Ammeter digital type square flush type |
| 211 | (e)Voltmeter digital type square flush type |
| 212 | (f) Copper wire single core for internal connection. |
| 213 | (g) Voltage monitoring relay (digital type) |
| 214 | (h) DG set AMF digital deep sea Controller |
| 215 | M&L for taking out diesel from the fuel tank of DG set of capacity 20 KVA to 160 KVA and cleaning the fuel tank complete of any size complete all as specified and directed.. |
| 216 | M&L for De-scaling & cleaning , painting (except fins area) & welding / soldering / brazing of radiator of any capacity & any type ccomplete all as specified and directed. |
| 217 | Supply only coolant for radiators of DG sets of capacity 30 KVA to 750 KVA complete all as specified and directed. |
| 218 | Supply only battery distilled water for batteries of DG sets complete all as specified and directed. |
| 219 | M&L for draining out old engine oil and filling new engine oil of grade as recommended by manufacturer for DG set any make and capacity complete all as specified and directed. |
| 220 | S & F in replacement of fuel indication transparent plastic tube of any size as per existing complete all as specified and directed. |
| 221 | Supply and fix in replacement of broken acoustic enclosure door hinges with stainless steel hinges complete with nut bolts etc as per site requirement of any type, cap and make of DG set complete all as specified and directed. |
| 222 | Materials andlabour for scraping removing and cleaning old rusty paint from enclosure of DG set 62.5 KVA to 160KVA capacity any make by cleaning agents & painting the above DG set complete with Polyurethane (PU) paint complete all as specified and directed. |
| 223 | Silencer with exhaust pipe complete bends, coupling etc suitable for 100 to 400 KVA DG set including fixing arrangements and painting with silver colour over a coat of red oxide primer complete all as specified and directed. |
| 224 | Supply & Fix in replacement of automatic voltage regulator 62.5 to 400 KVA DG set complete all as specified and directed. |
| 225 | Supply and fixing ofPVC Insulated, PVC Round Sheathed Multi Core Industrial Flexible Cable conforming to IS 694:2010 with Flexible Bright Annealed Copper Conductor for Voltage Grade 1100 Volt 1.5 sqmm and 7 core from DG set to AMF Panelcomplete all as specified and directed. |
| 226 | Supply and fixing of 180 AH sealed lead acid battery 12 volt into DG set with all necessary connections complete all as specified and directed. |
| 227 | Labour only for comprehensive maintenance ofand attending day to day break down of DG Set including servicing including first hand repairs, consisting of normal repairs such as tightening of nut bolts, greasing, checking/replacing of battery terminals, levelling of distilled water, cleaning of main ,battery charging alternator where ever exists with vacuum cleaner including replacements of defective/ worn out spares such as diesel filters, oil filters, rubber hose pipe ,V-belt, fuel pipe and change of oils etc. and cleaning of Radiator with new at site complete all as specified and directed.Note:-(i) The maintenance cost of DG Set shall deemed to comprises of cost of labour employed for the purpose, T&P used and other petty items such as cotton waste, Kerosene oil, Grease, nuts, bolts and labour cost for fixing spares. (ii)All spares and oil replaced will be measured and paid under relevant items of schedule ‘A’.(iii) Servicing shall be carried out by authorised dealer of manufacturer i.e. OEM.(iv)Non attending the complaint with in 8 Hrs @ Rs. 2000.00/day shall be recovered by the contractor.(v)Keep the complaint pending after one day @ Rs.4000.00/day shall be recovered by the contractor.(vi) The complaint shall be generated by Telephonically/Verbally by concern JE E/M or Engr-Incharge.(g) Spares shall be measured and paid separately. (h) Comprehensive maintenance of DG sets is applicable for contract period per job and shall be measured and paid once as one job on completion of contract. |
| 228 | (a) 62.5 KVA to 125 KVA |
| 229 | (b) 160 KVA to 250 KVA |
| 230 | (c) 500 KVA to 750 KVA |
| 231 | Material and labour for taking shutdown and disconnecting cables from AMF panel and DG set of 62.5 KVAand dismantle the spare parts of any make and type and disconnect the engine from the alternator and transport it to the workshop and conduct engine overhauling of DG setand replace all the unserviceable spare parts such as all gasket, piston rings, valve guide etc with the new one and reassembling of complete DG set and testing commisioning complete all as specified and directed by OEM and Engr-In-charge.Note:- Cost of spare parts such as Gasket, piston rings, valve guide etc are included in quoted rates , other spare parts will be measured and paid seperately under relevant item of this Schedule. |
| 232 | M & L for comprhensiverepair/maintenaceof Fire alarm system installed at various Tech Bldgs of 9 BRD comprehensive maintenancethe following worksincludingNote:-(i) The maintenance cost offire alarm systemshall deemed to comprises of cost of labour employed for the purpose, T&P used and other petty items such as batteries for wire less system and other cleaning materials etc. (ii) Servicing shall be carried out authorised dealer.(iii)Non attending the complaint with in 2 days @ Rs. 1000.00/day shall be recoveredfor the fourth day by the contractor.(iv)Keep the complaint pending after 3 days @ Rs.2000.00/day shall be recovered by the contractor.(v) The complaint shall be generated by Telephonically/Verbally by concern JE E/M or Engr-In-charge.(vi) Cost of updating/ Reinstallation the software is included in quoted rates.(vi) Servicingof fire alarm system once in every two months installed in following Bldgs including first hand repairs, consisting of normal repairs andcleaning of all components such as smoke detectors/manual call point/sounder/translator/expendor / input/output module etc of any type installed in Bldgs using proper method and tools , replacement of unserviceable Battries, tightening of all connections as required including replacements of defectivespares andrequired calibration of control panel and connected items check and maintain the system for efficent functiong of entire system,incling troubleshooting and clearance of all faults from the panel.Testing of each Fire alarm system in Presence of User and MES Repandgiveservicibility reportcomplete all as specified & directed by Engineer-in-charge.vii) Testing shall be carried out once in every two months or required basis as directed by Engr-In-Charge.(vii) Programming and reprogramming of control panel is deemed to be included in quoted rate.Note :MajorItems except batteries ifrequired forRepairshall be measured &paid separately underrespective item (a) OTS Hall ( Hochiki Wireless)(b) DSBay ( Hochiki Wireless)(c) Terc Lab No 1 ( Hochiki Wireless)(d) Terc Lab 2 ( Hochiki Wireless)(e) NWIT (f)Fire Station ( Hochiki Wireless)(g) ABR Lab ( Hochiki Wireless)(h) ACMI Lab(j) CAFS Lab (Hochiki wired))(k)Site 2 & 4 ( Hochiki Wireless)(l) Clothing store( Hochiki Wireless)(m) LSW ( Hochiki Wireless)(n)Armoury( Hochiki Wired)(o) D Level ( Honywell Morley wired)(p) Tech HQ (Wired)(q) Satcom and AFNET (Wired) |
| 233 | Supply onlyof Analogue AddressableMulti- Sensorwhich is fully compatible with Analogue Addressable Protocol,having removable high performance chamber with Twin fire LED\"s allow 360 degree veiwing, User selectable sensitivity modes 1% to 4.5% obs/m, Incorporate Optical and dual Heat elements, lock mechanism ( sensor to base), Electronically addressed, Pulsing/non-pulsing controlled from panel. complete all as specified and directed by Engr-in-Charge. |
| 234 | Supply Only of Analogue Addressable Manual Call Point with Integral Short Circuit Isolator, Analogue Addressable Protocol having,Bi-coloured status LED (red for alarm, amber for (short-circuit), Non-frangible element fitted as standard (conforms to EN54), pulsing/non-pulsing can selectable via panel, Electronically addressed, complete all as specified and directed by Engr-in-Charge. |
| 235 | Supply only of Intelligent loop powered wall Sounder which provide a range of tones and volumes with a maximum output of up to 102dB(A) (±2dB(A)) with low current consumption, 51 user selectable tones (all tones EN54-3 compatible). complete all as specified and directed by Engr-in-Charge. |
| 236 | Supply only of Hybrid Wired Translator Module with Bi-directionalcommunication,Self optimisingamplitude and frequency, Loop Powered, allows the connection of up to 126* radio field devicesto an addressable fire detection loop, Incorporates a Loop Short Circuit Isolator and an OLEDdisplay, operating on 865 MHz with communication range up to 1000 m in open air, 95% RH (non condensing), RED compliant, LPCB Approved, Approved to EN54-17, 18 and 25 |
| 237 | Material and labour for supply and fix armored fire cable copper conductor of size 1.5 sqmm fourcore FRLS in Red colour fixed on wall / roof with GI saddle complete all as specifed and directed by Engineer-in-Charge at site |
| 238 | Supply only of Hybrid Wireless Optical smoke Sensor with Bi-directional wireless communication, Self optimising wireless amplitude and frequency in built magnet test operating on 865 MHz with communication range up to 1200 m in open air 95% RH (non condensing) Primary secondary Power supply Red complaint LPCB approved to EN54-7 & 25 |
| 239 | Supply of Hybird wireless Manual Call point with Bi-directional wireless communication self optimising wireless amplitude and frequency resettable element fully addressable and intelligent monitoring functionality operating on 865 MHz with communication range up to 1200 m in openair 95% RH (non condensing) Up to 10 year battery life Dependant on operational usage primary and secondary power supply LPCB approved Approved to EN54-11 & 25. |
| 240 | Supply of Hybrid Sounder with Bi directional wireless communication self optimising wireless amplitude and frequency 4 tone settings fully addressable and intelligent monitoring functionality operating on 865 MHz with communication range up to 1200 m in open air with Max. Sounder output 93 db(A) @ 1 metre 95% RH (non condensing) up to 10 year battery life dependent on operational usage primary & secondary power supply LPCB approved Approved to EN54-3 and 25 |
| 241 | Supply of Hybrid Wireless Translator Module with Bi - directional wireless communication self optimising wireless amplitude and frequency loop powered allows the connection of up to 126* radio field devices to an addressable fire detection loop incorporates a loop short circuit isolator and an OLED display operating on 865 MHz with communication range up to 1000 m in open air 95%RH (non condensing) RED complaint LPCB approved approved to EN 54-17, 18 and 25. |
| 242 | Supplyof Expander Module shall work on 865MHz and allows extended signal coverage for the wireless system by boosting signal strengths from Translators to cover larger buildingIP65 protection for exterior mounting requires external power suppy LPCB approved. complete all as specifiedand directed by Engineer-in-Charge. |
| 243 | Supply installation testing in replacement and re commissioning of 2 Loop expandale to 5 loop networkable analogue addressable fire alarm control panel compatibe with existing detectors anddevices installed in the premises.Two loop fire control panel 2 loop card in built 198 addreressable points (99 detectors + 99 devices ) 6*40 character blue crystal display with backlight illumination 2 sounder circits complete all as directed. |
| 244 | Supply and laying HDPE DWC pipe 32mm dia SN8 on wall/ along ground/ along channel/ in trench/under roof/ along pillar or as directed complete. |
| 245 | Excavation in trenches not exc 1.5 m wide andnot exc 1.5 m in depth and getting it out for laying of cable / poleSoft/loose soil complete all as specified and directed by Engr-in-Charge. |
| 246 | Excavation in trenches not exc 1.5 m wide andnot exc 1.5 m in depth and getting it out for laying of cable / pole in hard dense soil complete all as specified and directed by Engr-in-Charge. |
| 247 | Excavation in trenches not exc 1.5 m wide andnot exc 1.5 m in depth and getting it out for laying of cable / pole in soft disintegrated rock complete all as specified and directed by Engr-in-Charge. |
| 248 | Removing the surplus spoil to a distance not exceeding 50 mtrs from the starting point and depositing at a height not exceeding 1.5 m above ground level complete all as specified and directed by Engr-in-Charge. |
| 249 | Returning/ Refilling of excavated soil including spreading levelling and well ramming in layers for any type of soil complete all as specified and directed by Engr-in-Charge. |
| 250 | Supply only Industrial calling gong bellcomplete |
| 251 | Supply only IndustrialBell Push including all elecrical connection complete |
| 252 | Supply only maintenace free 12V 12 to15 AH battery suitable for fire alarm panel conplete |
| 253 | Repair of unserviceable control panel/ repeater panel installed at any location of 9BRD including replacement of its accessories as requiredincluding motherboard complete incl taking down the unsv panel and transporting to workshop and refixing and testing after complete all as specified and directed by Engr-In-Charge. Note: Cost of replacement of any part/ accessory of panel is included in quoted rates and nothing shall be paid extra on this account. |