| 1 | GENERAL SUMMARY |
| 2 | Lump sum price worked out by the contractor against Schedule ‘A’Part- I (BUILDING WORKS)for the following building works:- |
| 3 | (a) Lump sump amount worked out by the contractor for Design, development of structural drawings as per the architectural drawing Nos CWE/ARCH/32/2025 Sheet No. 1/2, CWE/ARCH/32/2025 Sheet No. 2/2 and Construction of Weapon training aid store for training battalion, Storage Accomodation forweapons (Armouries) and SAA Stores as per architectural drawings, structural drawing, TD drawings, schedule of finishes & given specifications, etc complete all as specified and as directed. NOTE:- The structural design and drawing shall be got vetted from any IITs/NITs before execution of work by the contractor. |
| 4 | Lump sum price worked out by the contractor for EXCAVATION ANDEARTH WORKas listed in Schedule ‘A’Part- II (Ref prepriced schedule attached seperately) |
| 5 | Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKSas listed in Schedule ‘A’Part-III (Ref prepriced schedule attached seperately) |
| 6 | Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKSas listed in Schedule ‘A’Part-IV (Ref prepriced schedule attached seperately) |
| 7 | Lump sum price worked out by the contractor for PATH WORKSas listed in Schedule ‘A’Part-V (Ref prepriced schedule attached seperately) |
| 8 | Lump sum price worked out by the contractor for AREA DRAINAGE WORKS as listed in Schedule ‘A’Part- VI (Ref prepriced schedule attached seperately) |
| 9 | Lump sum price worked out by the contractor for FENCING WORKS as listed in Schedule ‘A’Part- VII (Ref prepriced schedule attached seperately) |
| 10 | SCH \"A\" Pt - VIII (MISCELLANEOUS PARTS) |
| 11 | M&L for concealed point wiring with 1.5 Sqmm PVC-FRLSH insulated, sheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduit,includingmodular metal flush boxes & modular white cover plate with frame as per site requirement all fittings such as tees, bends, elbows,etc. of External diameter 20mmall as per site requirements PVC insulated & sheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and directed. |
| 12 | For one light, fanpoint controlled by one switch complete all as specified and directed |
| 13 | For one5 Amp independent socket point controlled by one switch complete all as specified and directed |
| 14 | For one 3 pin ,5 Amp socket point with other switch on the same board complete all as specified and directed |
| 15 | All as per item No 8.10 here in before but for power point wiring usingwith 2.5sqmm PVC-FR LSH insulated ,sheathed, copper conductor stranded 1100 volt grade cable and 2.5 sqmm PVC insulated ,sheathed, copper conductor stranded 1100 volt grade cable as continuous earth lead complete all as specified and directed. |
| 16 | S&F double door metallic sheet metal enclosureDBdouble door(DPX-125 ) VTPN suitable for housing 100MCCBas incomer 4 Way 415 Volts with 200 Amps rated bus bars complete all as specified and directed. |
| 17 | S&F LED bulb 10 wattsuitable for angle / batten holder fitting complete all as specified and directed. |