| 1 | S&F of Circular shape architectural RGBW (W=4000K) LED flood light with integral driver & housing made of Die-cast aluminium alloy. The luminaire shall be no less than Ø 225 X 205 (±10%) with bracket. The luminaire shall have electrostatically applied polyester powder coating finish. The luminaire bracket shall be made of cold-rolled steel & shall be so designed that the luminaire can be tilted to ±90°. The bracket shall have locking mechanism to fix & secure the desired tilt angle. The product should be with discrete R,G,B,W LED\"s. 4 in 1 or 3 in 1 LED system are not allowed. The luminaire shall have silicon gasket between optical cover & LED chamber to ensure proper IP-66 protection. The luminaire must have a breather gland. The nominal weight of the luminaire shall not be more than 6KG. The luminaire shall be equipped with high-power Cree, osram, lumiled. The fixture shall have 10-15° beam angle & the lens shall be made of anti-aging & anti UV-PMMA material. The optical cover shall be made of IK06 rated clear tempered glass. The LEDs shall have minimum CRI ≥80 for white light & shall have SDCM≤4. The fixture shall come with power & DMX cable of minimum 100mm length. The fixtures shall be installed with have IP67 connectors. The luminaire shall have system wattage not exceeding 100W and system lumen output of not less than 4200 lumens. Fixture shall operating temperature range of -40°C to 50°C. The fixture shall have an integral driver with input voltage for 220-240 VAC, 50/60Hz. The luminaire shall have declared life of 50,000 burning hours at L70 @ 35deg. The luminaire shall have class I insulation.The luminaire shall be compatible with DMX512 controller. The luminaire shall automatically addressable using hand-held addressing device.The luminaire shall give feedback on luminaire address & status (ON & Off). The luminaire shall be capable of 8-bit control of RED, Green, Blue & White (W=4000K) to produce 16.7million colours. The successful bidder shall submit the following certifications/reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer & RoHS Compliance alone with CE certificate. The luminaire shall be supplied with necessary connectors for connecting lead/jump cables complete all as specified and directed.Make : Philips/Signify or equivalent in Endo/ Trilux/ SSK/ iGuzzini/ Linealite/ martin & We-e |
| 2 | S&F of Circular shape architectural LED flood light with integral driver & housing made of Die-cast aluminium alloy. The luminaire shall be no less than Ø135 x 141 mm (with bracket). The luminaire shall have electrostatically applied polyester powder coating finish. The luminaire bracket shall be made of cold-rolled steel & shall be so designed that the luminaire can be tilted to ±90°. The bracket shall have locking mechanism to fix & secure the desired tilt angle. The luminaire shall have silicon gasket between optical cover & LED chamber to ensure proper IP66 protection. The product should be with discrete R,G,B,W LED\"s. 4in1/3in1 LED system are not allowed. The luminaire must have a breather gland. The nominal weight of the luminaire shall not be more than 3KG. The luminaire shall be equipped with high-power Cree, osram, lumiled. The fixture shall have 10-15° beam angle & the lens shall be made of anti-aging & anti UV-PMMA material.The product should be with discrete R,G,B,W LED\"s. 4in1 or 3in1 LED system are not allowed. The optical cover shall be made of IK06 rated clear tempered glass. The LEDs shall have minimum CRI ≥80 for white light & shall have SDCM≤4. The fixture shall come with power & DMX cable of minimum 100mm length. The fixtures shall be installed with have IP67 connectors. The luminaire shall have minimum system wattage 24W and system lumen output of not less than 1140 lumens. Fixture shall operating temperature range of -40°C to 50°C. The fixture shall have an integral driver with input voltage for 220-240 VAC, 50/60Hz. The luminaire shall have declared life of 50,000 burning hours at L70 @ 35deg. The luminaire shall have class I insulation.The luminaire shall be compatible with DMX512 controller. The luminaire shall automatically addressable using hand-held addressing device.The luminaire shall give feedback on luminaire address & status (ON & Off). The luminaire shall be capable of 8-bit control of RED, Green, Blue & White (W=4000K) to produce 16.7million colours.The successful bidder shall submit the following certifications/reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer & RoHS Compliance alone with CE certificate. The luminaire shall be supplied with necessary connectors for connecting lead/jump cables complete all as specified and directed.Make : Philips/Signify or equivalent in Endo/ Trilux/ SSK/ iGuzzini/ Linealite/ martin & We-e |
| 3 | S&F of exterior IP68 LED RGB/RGBW Flexible light strip of 5 mtr standard length with 10-15 Watt per meter which can be compatible with the DMX / Ethernet controller. Minimum System lumens of minimum 450 lumens/meter and System Lumen Efficacy > 30lm/w. Luminaire light beam spread - 110°, The Strip should have IP 68 protection and is offered IP 67 rated connector to join the LED Strips incontinuity. The luminaire must be offered with Aluminum channel for mounting the strip lights. The product should be complete with all accessories.The successful bidder shall submit the following certifications/reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer & RoHS Compliance alone with CE certificate. The luminaire shall be supplied with necessary connectors for connecting lead/jump cables complete all as specified and directed.Make : Philips/Signify or equivalent in Endo/ Trilux/ SSK/ iGuzzini/ Linealite/ martin & We-e |
| 4 | Supply and fixing of IP65 150W 24V driver complete all as specified and directed. |
| 5 | Supply and fixing of DMX decoder complete all as specified and directed. |
| 6 | Supply and fixing of AL profile(1m) complete all as specified and directed. |
| 7 | Supply and fixing of IP connector (Bag should contain minimum of 10 pieces) complete all as specified and directed. |
| 8 | S&F 1000mm long rigid architectural RGBW (W=4000K) LED Linear light with non-integral driver & housing of Extruded aluminium alloy & die-cast aluminium end caps. The luminaire shall have electrostatically applied polyester powder coating finish. The luminaire width shall be 25.4mm & height of 35mm without brackets. The luminaire’s integrated brackets shall be made of extruded aluminium & the same shall be so designed that the luminaire can be tilted ±95°. The luminaire shall have silicon glue between optical cover & LED chamber to ensure proper IP66 protection. The nominal weight of the luminaire shall be 0.86KG (±10%). The luminaire shall be equipped with low-power led\"s, approved make: Cree, osram, lumiled only. The fixture shall have 20°X30° beam angle & the lens shall be made of anti-aging & anti UV-PMMA material. The optical cover shall be made of IK06 rated clear tempered glass. The LEDs shall have minimum CRI ≥80 & shall have SDCM≤4. The fixture shall come with power & DMX cable of minimum 100mm length. The fixtures shall be installed with have IP67 connectors. The luminaire shall have minimum system wattage 24W and system lumen output of not less than 960 lumens. Fixture shall operating temperature range of -40°C to 50°C. The fixture shall have a non-integral driver with input voltage of 24V DC. The luminaire shall have declared life of 50,000 burning hours at L70 @ 35deg. The luminaire shall have class I insulation.The luminaire shall be compatible with DMX512 controller. The luminaire shall automatically addressable using hand-held addressing device. The luminaire shall be capable of 8-bit control of RED, Green, Blue & White (W=4000K) to produce 16.7million colours complete all as specifed and directed.Make : Philips/Signify or equivalent in Endo/ Trilux/ SSK/ iGuzzini/ Linealite/ martin & We-e |
| 9 | Supply, installation, testing and commissioning of Compact master Content Program Controller (DMX controller) with capability to control minimum 8 DMX512 universes, playback scenes and animations stored in its SD card, and it can be used for offline scenes scheduling, setting brightness, white balance and playback speed adjustments. It should be able to amplify the DMX signal in cascaded connection & support automatic playback scheduling. It should support power-on startup and scheduled timing start along with capability of unattended operation and remote scene triggering if needed. The Content Program Controller shall have integrated LCD display & support IR remote control. The dimensions of the Content Program Controller shall be approximately 278X193X66 mm (±10%). It should be housed in aluminium casing. The Input voltage shall be 12VDC & shall have 2 RJ45 ports on Input side. The IEC classification shall be Class III. It should operate on DM512 protocol. The output shall have 8 X 3P lockable terminals.The power consumption shall be 8W (±10%). The Content Program Controller shall have one SD card slot for maximum 32GB card & the SD card being used shall be FAT32 format. The Content Program Controller shall come with 220-240V to 12V DC power supply.The IP rating of content program controller shall be IP20 & shall comply to CE, CB & CQC certifications. The DMX controller/content program controller shall be from the same make/brand/manufacturer as that of façade lighting luminaires.The working temperature range shall be -30°C to 50°C. The successful bidder shall submit the technical data sheet for approval before supply of material complete all as specified and directed.Make : Signify (Philips) or equivalent in Endo, Trilux, iGuzzini, Linealite, martin & We-ef |
| 10 | S&F of RDM-6Wall Splitter, should be able to provide 6-output DMX/RDM splitter with DMX/RDM pass-through supporting bi-directional communications for discovery, addressing and DMX control of Ethernet/DMX products. This unit takes the incoming DMX/RDM signal and splits the signal into six separate output channels allowing for expanding the number of devices controlled from 32 to 6x32. The output terminals are electronically isolated from the input & RDM-through port and share a common ground reference. All six output ports have an independent output driver to boost the DMX/RDM signal. Surface or DIN-rail mountable, Isolated DMX/RDM Input/Outputs, Automatic switching between DMX and RDM mode for auto-discovery, Environment-IP20, Interior applications, Finish/Color-Polycarbonate, Certification : CE Certified complete all as specified and directed.Make : Philips/Signify or equivalent in Endo/ Trilux/ SSK/ iGuzzini/ Linealite/ martin & We-e |
| 11 | S&F of 5P/4P DMX leader cable for connecting luminaire with power supply having length min 2m length (min 10 nos in 1 packet) complete all as specified and directed.Make : Philips/Signify or equivalent in Endo/ Trilux/ SSK/ iGuzzini/ Linealite/ martin & We-e |
| 12 | S&F of 5P/4P DMX jumper cable for interconnecting the façade luminaires having length min 2m length (min 10 nos in 1 packet) complete all as specified and directed.Make : Philips/Signify or equivalent in Endo/ Trilux/ SSK/ iGuzzini/ Linealite/ martin & We-e |
| 13 | Supply and fixing of endcap male connector (20 pcs) complete all as specified and directed. |
| 14 | Supply and fixing of endcap female connector (20 pcs) complete all as specified and directed. |
| 15 | S&F of Programming for lighting management system includes addressing for all smart lighting fixture along with mapping on connected system. All fixture to be programmed as per the site requirement. Min 10 Scenes to be created & configure on smart keypad for ease of operation of smart light system complete all as specified and directed.Note: (a) The work has to be executed through OEM/OEM authorised agency only. (b) The contractor must sign bid specific MoU with the OEM for execution of work through OEM/OEM authorised agency.(c) The contractor must submit the copy of the MoU signed with OEM at the time of submission of Technical bid, failing which his technical bid shall be summarily rejected. Note For item Ser No 01 to 15:-(a) The quoted rates also include the cost of 2 run conduit of 25mm for power cable and Data cable.(b)The quoted rates also include the cost of required 2.5 and 1.5 sqmm wire for connections(03 run cable) for Phase,Neutral and earth wire as per OEM recommendation.(c) The quoted rates also include the cost of Cat6/control cable(beldon DMX cable) as per OEM recommendation.(d) The quoted rates also include the cost of necessary junction boxes with IP 66 protection, connectors drivers, shaddle, flexible conduit, assembly bracket, metal gauge, cable tray, point wiring, switch, socket etc as per OEM recommendations. |
| 16 | Supplying, fabrication, installation, testing and commissioning of LT panel not less than 3mm thick made out of modular polycarbonate thermoplastic enclosures outdoor type, factory made CPRI approved, floor mounting type, environment friendly, recyclable, UV resistant, halogen and silicon free, anti-acid and anti corrosive, IP-65 Protection in accordance with IEC 60529, 24 hrs astronomical time switch, auto/ manual selector switch, ON/OFF push buttons. The gasket material shall be plyurethane while the gas/ket shall be internally embedded including suitable working space suitable for 3 phase 4 wire system 415V, 50HZ, AC supplyand fixed on raised PCC base1:2:4, type B1 (20mm graded aggregate) raised base with cable glands, phase indicators, internal wiring, CT of suitable Ratio, digital voltmeter and ammeter, air passing holes with proper spacing to accommodate to all control switches and other accessories, cable connections with suitable size of lugs/thimble etc including suitable size canopy to cover the panel with proper fixing arrangementincluding excavation and earth work complete all as specified and directed and comprising the followings.Incoming :(a)MCB 32 Amps, 4 Pole - 01 No(b)Power contactor - 32 Amps(c)Surge protection device - 01 No(d)RYB Indicating lamp(e)Digital Voltmeter and ammeter of suitable rating(f)Start/stop Push Button -1 No(g) Over voltage/under voltage relay - 01 NoOutgoing:(a) MCB DP, 32 Amps, 2 pole - 02 Nos |
| 17 | Supply, installation, testing and commissioning of single phase voltager stabilizer of capacity 05 KVA, Minimum input voltage 90-130V, minimum output voltage130V, maximum output voltage 290-300 Volts including digital display, digital indicators, over volt protection and overload protection complete all as specified and directed by Engr- In- Charge. |
| 18 | S&F factory made concealed sheet steel distribution boards, double door, SPN, 12 way, 230 volts AC, IP 43 with suitable busbar, neutral link, earth link suitable for MCB, DP/SPN as incomer & MCB SP as outgoing complete all as specified and directed. |
| 19 | S&F MCB DP 32 Amps, 240 Volts, 10 KA, `B\" curve, all as per site requirement complete all as specified and directed by Engr-in-Charge. |
| 20 | S&F MCB SP 6 to 32 Amps, 240 Volts, 10 KA, `B\" curve, all as per site requirement complete all as specified and directed by Engr-in-Charge. |
| 21 | M&L for Earthing complete with galvanized steel earth plate 600x600x6mm thick, buried directly in ground(earth pit not less than 2.25 m deep below ground level) with top edge of the plate n.less than 1.5 m belownormal groundlevel, connected to galvanized iron wire 4 mm as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints as shown in drgs and including excavation and earth work, GI pipe light grade 25mm bore of protection of GI wirefrom earth electrode, supply and laying charcoaldust, common salt, PCC (1:2:4)type B-1 Chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4)type B-1using 20 mm graded stone aggregate Reinforced with 6 mm dia round bars@75 mm C/C both ways with MS handle 12 mm dia , PGI funnel and wire mesh , 20 mm dia GI Pipe light grade for wateringcomplete all as specified and directed by Engr-in-Charge. |
| 22 | S&F of IP67 suitable sizes Junction boxes with necessary accessories complete all as specified and directed.Make : Legrand/Precision/Sintex |
| 23 | Supply and fixing of 4 Core X 6 sqmm Type Ar. Aluminium cable complete all as specified and directed. |
| 24 | Supply and fixing of 3 Core X 2.5 sqmm FRLS Type fexible Copper cable complete all as specified and directed. |
| 25 | Supply and fixing of CAT6A Armoured cable complete all as specified and directed. |
| 26 | Supply and laying of 6 SWG GI Wire complete all as specified and directed. |
| 27 | Supply, installing, commissioning and testing complete of Manufacturer or OEM (Original Eqpt Manufacturer) manufactured and tested silent Diesel Engine driven generating set capable of delivering 250 KVA (200 KW), or nearest higher rating, 415 volts (AC 3 Phase, 4 wire system of supply), 50 Hz to operate at a powers factor of 0.8. The DG set shall consist of a diesel engine coupled through flexible coupling to a matching alternator and mounted on AVM pads (As per respective Mnufacturer Design ) on a common base frame all as specified complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe as per IS 10001/10002 and alternator as per IS 13364 complete with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms and including foundation and control cabling & power cabling with end terminal connections. The DG set shall comprise of the following: - |
| 28 | (a) Engine (Prime Mover) :Diesel engine 6 cylinders, inline, 4 stroke cycle, water cooled, gross engine power minimum of 300HP at 1500 RPM under NTP conditions of ISO 3046, or having suitable HP as recommended by manufacturer, Turbocharged, the engine shall be provided with electrical starging arrangement and give the electrical output of 250 KVA/200 KW at 0.8 power factor, 415 volts at the alternator terminal. 2 x 12 V DC 180 AH batteries,confirming to BS 5514,BS 649 and IS 10000 complete with fly wheel and all standard fittings/ fixtures as per manufacturing practice including suitable engine control panel with tachometer, lube oil temp & pressure gauges, water temp gauge, and frequency meter(digital type) (including safety shutdown contents) and also including self starter, dynamo, fuel tank etc.(b)Alternator : AC alternator, self excited, self regulated, self ventilated, brushless design, conforming to BS 2613 / 5000, 3 phase , 415 volts, 4 wire rated line current 347.8 amps for outputPF 0.8, 1500 RPM, insulation class ‘H’ Temprature Reise H @ 125 Deg C; Enclosure IP 23confirming to IS-4722 / BS-2613 complete with AVR with + 1 % voltage regulation,directly coupled to and match the above engine with unbalancing load capacity of 25% of rated Amps.(c) Anti-vibration pads for mounting engine – alternator assembly on the base frame/ plate. |
| 29 | (d) Base Frame : One no. MS Fabricated adequately machine Channel Common Base Frame with lifting facility, pre-drilled foundation holes suitable for permanent installation on concrete foundation for direct grouting or on anti-vibration mountings which will be suitable to receive the offered engine and alternator duly coupled through a flexible coupling. A suitable coupling guard shall also be provided.(e) Silencer: Critical Gradeand exhaust gas piping system of suitable dia MS pipe of \"B\" class of required legth as per CPCB norms with necessary bends, supports and clamps anti vibration mounting inulated with rockwool 50 mm thick with wire mesh and aluminium clading complete all as specified.(f) Fuel tank of capacity 385L or as specified by the manufacturer, made of 14 SWG CRCA MS sheet, duly powder coated and provided with float, gauge and fuel float switch.(g) Emission limit & smoke limit for DG set shall be as per CPCB norms applicable at the time of execution. |
| 30 | AMF Panel.Fabricating, Installing, Testing & Commissioning of automatic mains failure control including auto by-pass panel, suitable for 250 kVA silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyzer to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARHprovision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF panel to diesel engine and elsewhere if required all connection at site to make it fully functional, complete and inter locking including for following:AMF panel should have provision for 01 x 400 sqmm & 01 x 150 sqmm size cables as main incoming supply & outgoing supply & 02 x 240 sqmm cables as the incomers from DG Set. AMF panel will be outside the DG set fabricated & installed separately as directed by Engineer-in-Charge. directedOutgoing supply MCCB 400 Amps. 4 PoleAuto/ Manual/ Test/ Off selector switch(a) 2 Nos over voltage relay, 2 Nos reverse power relay and 2 Nos under voltage relay.(b) 3 Sets of current transformers 15P 10 accuracy for protection and 15 VA class-I for metering(c) Energy analyzer unit to indicate current voltage frequency power factor and KWH(d) Indicating lamps for load on mains and load on set |
| 31 | (e) Fuse for instruments(f) Battery charger, complete with transformer/ rectifier, D.C voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment(g) Main supply failure monitor(h) Supply failure timer(i) Restoration timer(j) Control unit with three impulse automatic engine start/ stop and failure to starty lockout(l) Impulse counter with locking and reset facility (i) Audio/ Video annunciation for (ii) High water temperature(iii) Low lubricating oil pressure (iv) Engine over speed(v) Engine fails to start(vI) Full load/ maximum load warming |
| 32 | M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 25X4 mm up to 7.50 RM bolted (with GI nuts, bolts & check nuts) and rivetedto earth (Plate) electrode at one end and connected to main switch board / test point at the other and watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0using 12 mmgraded crushed stone aggregate, RCC cover, funnel, wire mesh etc including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil complete all as specified and directed. |
| 33 | M&L for plate earthing complete with copper plate earth electrode of size 60 cm x 60 cm x 3.15 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including 20 x 3 mm copper strip as earth lead upto 7.5 RM bolted (with GI nuts, bolts & check nuts) and rivetedto earth (Plate) electrode at one end and connected to main switch board / test point at the other and watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0using 12 mmgraded crushed stone aggregate, RCC cover, funnel, wire mesh etc including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil complete all as specified and directed.Note: (a) Srl Item No 01.00 to 03.00, 06.00, 08.00, 09.00, 12.00, 15.00, 16.00, 24.00, 25.00 & 27.00 of BOQ are major items for the subject tender and material in respect of these items shall be procured within one month after placing of work order and produced before Engg in Charge alongwith original purchase vouchers as per direction of Garrison Engineer and shall obtain a certificate from Engg in charge that material in respect of above mentioned items have been submitted in the office of Engg in charge in their safe custody.(b) Materials in respect of Freakishly low declared items if any at the time of acceptance of contract shall be procured within one month after placing of work order and submit the same in the office of Engg in charge alongwith original purchase vouchers in their safe custody and shall obtain a certificate from Engg in charge. |